Engineering PapersSearch

SEARCH · Engineering Papers

Results for “SCaN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Characterization of the image plate multi-scan response to mono-energetic x-rays

Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.

Instruments & Instrumentation

Identifying Potential Sub-Synchronous Oscillations Using Impedance Scan Approach: Preprint

This paper presents an impedance scan study on the real-world power system in Australia that has observed 17 to 20 Hz intermittent subsynchronous oscillations. Through the impedance scan of each of the IBRs, both individually and collectively, potential resonance modes are identified. The impedance scans were carried out using electromagnetic transient PSCAD models of the network. The network comprises of site-specific, black-boxed models of IBRs supplied by the generators. The impedance scan approach was divided in three major steps: (1) the first step is to identify IBRs where impedance analysis needs to be performed based on the magnitude of oscillations observed at their points of interconnection (POIs); (2) the second step focuses on performing impedance scans at selected IBRs in single-machine infinite-bus (SMIB) configuration to identify internal resonance modes of an IBR and to evaluate if any of these modes become unstable under certain grid conditions; (3) the third step performs impedance scans at a few selected IBRs while connected to the wider network model to obtain the impedance response of both the IBR and the grid - this step evaluates control interactions among IBRs. The impedance scan study found that a few IBRs have an underdamped resonance mode at around 17 Hz, which becomes unstable under a certain operating condition. Another interesting finding was that certain IBRs increase the effective grid impedance seen by another IBR in proximity for a particular operating condition. Under this operating condition, the resulting subsynchronous oscillation mode is more pronounced due to a combination of control interactions among IBRs through the transmission network under study and a resonance mode inside the IBRs.

control interactions

Scanning Electrochemical Microscopy: An Evolving Toolbox for Revealing the Chemistry within Electrochemical Processes

The parallel development of ultramicroelectrodes (UMEs) and groundbreaking scanning probe microscopy techniques in the late 1980s led to the development of the scanning electrochemical microscope. Scanning electrochemical microscopy (SECM) was born from the idea of using a tiny electrode to measure the local electrochemical behavior at operating electrodes. From its foundations, the technique displayed an inherent versatility in measuring sample properties beyond topography. It allowed experimenters to measure and map chemical reactions occurring at diverse interfaces, from inspecting the reversibility of redox mediators at metal electrodes, to detecting the hallmarks of cellular respiration on living plant leaves. Related but distinct electrochemical scanning probe techniques, such as electrochemical atomic force microscopy (EC-AFM), scanning ion conductance microscopy (SICM), and scanning electrochemical cell microscopy (SECCM) have developed in parallel. These techniques have demonstrated exquisite spatial resolution down to the nanoscale regime. However, it is the proposition of this review that SECM remains unmatched at revealing the chemical aspects of electrochemistry. Furthermore, it is our intention to review and demonstrate that the versatile architecture of SECM continues to evolve and address fundamental and emerging challenges in the fields of energy storage and conversion, chemical biology, materials science, and environmental chemistry, among others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

A Cloud-Tracking Data Set for the CSAPR2 Adaptive Scanning during TRACER

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility (Mather and Voyles 2013) deployed the first ARM Mobile Facility (AMF1; Miller et al. 2016) near LaPorte, Texas to support the Tracking Aerosol Convection Interactions Experiment (TRACER) (Jensen et al. 2025) near Houston, Texas. From October 2021 to September 2022, AMF1 was deployed to 29.67° N, 95.06° W near LaPorte, Texas and the 2nd Generation C-band Scanning ARM Precipitation Radar (CSAPR2) was deployed to a supplementary site at 29.53° N, 95.28° W (Figure 1). During an intensive operational period (IOP) from 1 June to 30 September 2022, the CSAPR2 sampled precipitation echoes in an adaptive scanning mode following the Multisensor Agile Adaptive Scanning (MAAS) framework (Kollias et al. 2020). MAAS helped optimize the CSAPR2 scan strategy to perform frequent plan position indicator (PPI) and range height indicator (RHI) scans (Lamer et al. 2023). Details of the CSAPR2 scanning, data processing, and calibration procedures used by the principal investigator (PI), and the PI data files are described by Oue et al. (2023). Details of the CSAPR2 operational performance, ARM data processing and correction procedures, and data quality masks are described by Feng et al. (2024a).

54 ENVIRONMENTAL SCIENCES

Scan‐Path‐ and Initial‐State‐Dependent Superdomain Switching in (111)‐Oriented PZT

Polarization switching in ferroelectric materials arises from the collective evolution of complex domain hierarchies, yet deterministic control over these processes remains challenging. Here, we investigate scan-path- and initial-state-dependent switching in epitaxial (111)-oriented PbZr 0.2 Ti 0.8 O 3 thin films using automated AFM-based writing combined with quantitative 3D piezoresponse force microscopy. We show that the scan trajectory acts as an experimentally accessible control parameter for superdomain formation. Box-in-box raster scans reproducibly stabilize ordered stripe superdomains with a reduced subset of symmetry-allowed variants, whereas spiral trajectories generate frustrated mixed-variant states with a broader distribution of final microstructures. Automated pulsing experiments further show that the local superdomain configuration at the nucleation site strongly influences the final written morphology. Phase-field modeling qualitatively reproduces the contrast between representative initial-state geometries and supports the role of compatibility constraints among competing ferroelastic pathways. These findings establish scan-path and initial-state engineering as practical handles to program ferroic order in hierarchical ferroelectric domain structures.

Vasudevan, Rama K. [Oak Ridge National Laboratory

A machine learning decision criterion for reducing scan time for hyperspectral neutron computed tomography systems

We present the first machine learning-based autonomous hyperspectral neutron computed tomography experiment performed at the Spallation Neutron Source. Hyperspectral neutron computed tomography allows the characterization of samples by enabling the reconstruction of crystallographic information and elemental/isotopic composition of objects relevant to materials science. High quality reconstructions using traditional algorithms such as the filtered back projection require a high signal-to-noise ratio across a wide wavelength range combined with a large number of projections. This results in scan times of several days to acquire hundreds of hyperspectral projections, during which end users have minimal feedback. To address these challenges, a golden ratio scanning protocol combined with model-based image reconstruction algorithms have been proposed. This novel approach enables high quality real-time reconstructions from streaming experimental data, thus providing feedback to users, while requiring fewer yet a fixed number of projections compared to the filtered back projection method. In this paper, we propose a novel machine learning criterion that can terminate a streaming neutron tomography scan once sufficient information is obtained based on the current set of measurements. Our decision criterion uses a quality score which combines a reference-free image quality metric computed using a pre-trained deep neural network with a metric that measures differences between consecutive reconstructions. The results show that our method can reduce the measurement time by approximately a factor of five compared to a baseline method based on filtered back projection for the samples we studied while automatically terminating the scans.

97 MATHEMATICS AND COMPUTING

Scanning electrochemical probe microscopy investigation of two-dimensional materials

Research interests in two-dimensional (2D) materials have seen exponential growth owing to their unique and fascinating properties. The highly exposed lattice planes coupled with tunable electronic states of 2D materials have created manifold opportunities in the design of new platforms for energy conversion and sensing applications. Still, challenges in understanding the electrochemical (EC) characteristics of these materials arise from the complexity of both intrinsic and extrinsic heterogeneities that can obscure structure–activity correlations. Scanning EC probe microscopic investigations offer unique benefits in disclosing local EC reactivities at the nanoscale level that are otherwise inaccessible with macroscale methods. This review summarizes recent progress in applying techniques of scanning EC microscopy (SECM) and scanning EC cell microscopy (SECCM) to obtain distinctive insights into the fundamentals of 2D electrodes. We showcase the capabilities of EC microscopies in addressing the roles of defects, thickness, environments, strain, phase, stacking, and many other aspects in the heterogeneous electron transfer, ion transport, electrocatalysis, and photoelectrochemistry of representative 2D materials and their derivatives. Perspectives for the advantages, challenges, and future opportunities of scanning EC probe microscopy investigation of 2D structures are discussed.

36 MATERIALS SCIENCE

Hard X-ray imaging with sub-10 nm resolution by scanning bonded 2D multilayer Laue lenses

Multilayer Laue lenses (MLLs) offer significant advantages over traditional diffractive focusing optics, such as zone plates (ZPs), in terms of efficiency and durability when focusing hard X-rays to 10 nm and below. Typically, a pair of 1D MLLs is aligned independently to achieve point focusing. This approach only permits scanning microscopy by moving the sample stage, which presents a limitation when it comes to scanning large or bulky objects at high speed. In this study, we present an experimental demonstration of scanning monolithically bonded 2D MLLs while keeping the sample stationary, effectively addressing the limitation of the sample’s size and weight. We characterized the system’s positional and angular stabilities during scanning, which are critical parameters to the nanofocusing performance of MLLs. In addition, we provided the X-ray measurement results and corresponding image resolution analysis.

36 MATERIALS SCIENCE

Designing Track for Electrospinning Unit and Cost-Effective Laser Scanning System

Nanofibers are produced in the Targeted Systems Department (TSD) by applying a large voltage to the nanofiber fluid and the collection apparatus known as the electrospinner. The fiber is then shot out of nozzles and collected onto the electrospinner into a nanofiber mat. The problem is that since the nozzle heads are stationary, there is non-uniform deposition of nanofiber on the collection drum leading to variation in thickness of the produced nanofiber mat. To mitigate this issue, a reciprocating mechanism is designed to move the nozzle along the drum collector along with the ability to vary its stroke length. This design was realized using Siemens NX and several parts were printed using a 3D printer, but is, as of writing, untested. Second project involved providing an alternative method to scan a large sample that had undergone certain surface deformation by beam interaction and detect out of plane deformation such as micro-scale swelling and surface roughness. Systems to carry out this scanning already exist; however, they are expensive and produce many files that need to be stitched together and are cumbersome to deal with. The solution is to create a scanning system using an already purchased scanning laser and linear stage motor. The laser and stage motor were combined to produce length results that aligned with a digital microscope but differing height results.

Ruffolo, Leopoldo

Designing a track for an electrospinning unit and cost-effective laser scanning system

Nanofibers are produced in the Targeted Systems Department (TSD) by applying a large voltage to the nanofiber fluid and the collection apparatus known as the electrospinner. The fiber is then shot out of nozzles and collected onto the electrospinner into a nanofiber mat. The problem is that since the nozzle heads are stationary, there is non-uniform deposition of nanofiber on the collection drum leading to variation in thickness of the produced nanofiber mat. To mitigate this issue, a reciprocating mechanism is designed to move the nozzle along the drum collector along with the ability to vary its stroke length. This design was realized using Siemens NX and several parts were printed using a 3D printer, but is, as of writing, untested. Second project involved providing an alternative method to scan a large sample that had undergone certain surface deformation by beam interaction and detect out of plane deformation such as micro-scale swelling and surface roughness. Systems to carry out this scanning already exist; however, they are expensive and produce many files that need to be stitched together and are cumbersome to deal with. The solution is to create a scanning system using an already purchased scanning laser and linear stage motor. The laser and stage motor were combined to produce length results that aligned with a digital microscope but differing height results.

Ruffolo, Leopoldo

Controlling mechanical properties of laser powder bed fused AlSi10Mg through manipulation of laser scan rotation

The microstructure and mechanical properties of laser powder bed fused (LPBF) AlSi10Mg alloys can be controlled by many processing parameters. This study focuses on the scan rotation angle, α, between adjacent layers, and establishes the relationship between α and tensile behavior of the as-built LPBF-processed AlSi10Mg alloy. Near-full density cubic coupons were manufactured using the same processing parameters but with systematic variation of α from 0° to 90°. Microscopic observations and X-ray diffraction analysis showed that differences among various coupons mainly include orientations of the melt pools with respect to the build direction and development of the crystallographic texture. The α=0° coupon and α=30° coupon showed the highest and lowest texture index, although the overall crystallographic texture was mild. Tensile specimens were manufactured horizontally and vertically using either α=0° or α=30°, but with various first layer laser direction with respect to the build plate. Notably, the α=0° specimen that was tested along the laser scan direction showed the largest yield strength (283 MPa) and highest tensile ductility (10.1 %). Quantitative image analysis and fractography were performed on all specimens. Results showed that the melt pool orientation with respect to the tensile direction affected the tensile behavior across the different specimens. This was closely related to the localized strain distribution within the melt pool and along the melt pool boundary for the different melt pool orientations observed. Further, these results demonstrate that the laser scan rotation angle between layers can be used to fine tune the mechanical properties of LPBF AlSi10Mg alloy.

36 MATERIALS SCIENCE

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION

Speedup of UEDGE Parameter Scans Using Machine-Learning Optimized OpenMP Parallelization and a Continuation Solver

This article presents the OpenMP parallelization of the preconditioning Jacobian assembly and right‐hand side residual evaluation in UEDGE. A continuation algorithm, utilizing the internal NKSOL implicit Jacobian‐Free Newton‐Krylov solver to efficiently scan physical parameters, is also presented. The implemented parallelization reduces the computational time for a benchmark scan run on 32 threads by compared to the serial version when using trained random forest regression models to identify the optimal decomposition of the system of equations. Random forest regression models applied to the UEDGE time‐dependent and continuation solver algorithms did not yield meaningful improvement in computational performance. A benchmark DIII‐D gas injection rate scan in the 0.35–0.75 kA interval, performed on a test cluster using the parallelized code and continuation solver, produced 1066 steady‐state solutions with a 22 s average wall‐clock computational time per steady‐state solution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Ab Initio Modeling of Aqueous Methanol Mixtures at DFT-SCAN Level Using Machine Learning Interatomic Potentials

Abstract Methanol–water mixtures find use in many applications, particularly catalytic energy conversion processes. Their importance has motivated numerous computational studies, most of which employed molecular dynamics based on classical force fields. These enable simulations of large systems on long time scales but do not reliably describe reactive dynamics involving bond breaking and bond formation. In contrast, ab initio molecular dynamics (AIMD) based on density functional theory (DFT) is generally more reliable for such applications but has a high computational cost, which discourages systematic studies of alcohol-water mixtures. To remedy this, we trained a machine learning interatomic potential capable of probing the properties of aqueous methanol mixtures at the DFT level using the SCAN functional. Our results show that SCAN qualitatively reproduces multiple key experimental features arising from the amphiphilic nature of methanol, including density, diffusion coefficients, X-ray structure factors, and Kirkwood–Buff integrals. We also find that structural correlations between water molecules are somewhat overestimated, leading to a stronger preferential association than that predicted by experiments. However, increasing the temperature by 30 K mitigates this effect and also recovers the correct mobilities of both methanol and water. These results indicate that SCAN provides an accurate description of methanol–water mixtures, making it a reliable choice for investigating the reactive dynamics in such systems.

Park, Sanghyun J. [Princeton University , , , ,]

Nanophotonic waveguide chip-to-world beam scanning

A seamless chip-to-world photonic interface enables broad advancements in optical ranging, display, communication, computation and quantum information science. The ideal solution enables two-dimensional scanning of a diffraction-limited beam from anywhere on a photonic integrated circuit to a large number of resolvable spots. Current beam-scanning technologies are limited by a fundamental trade-off: photonic-integrated-circuits with diffractive optics offer scalability but have poor mode quality, whereas inertially limited micromechanical scanners provide high-quality beams but lack scalable integration. Here we report a photonic ski-jump—a nanoscale waveguide monolithically integrated on a piezoelectric cantilever—to overcome these limitations. It passively curls ~90° out-of-plane within a less-than-0.1 mm 2 footprint, emits a submicrometre, broadband diffraction-limited beam, and exhibits kilohertz-rate mechanical resonances with quality factors of over 10,000. Fabricated in a volume complementary metal–oxide–semiconductor (CMOS) foundry, our device enables scalable two-dimensional beam scanning. Driven on-resonance at CMOS-level voltages, it achieves a footprint-adjusted spot rate of 68.6 mega spots s –1 mm–², exceeding state-of-the-art micro-electro-mechanical systems mirrors by more than 50-fold, which is sufficient for one million pixels at 100 Hz from an approximately 1.5 mm diameter footprint. We demonstrate full-colour image and video projection, and single-photon initialization and readout from silicon vacancy centres in diamond. Finally, by demonstrating uniformity across a 64 ski-jump array, we establish a pathway to achieving greater than one gigaspot resolution at kilohertz rates within a sub-5-cm-diameter footprint, creating a seamless optical pipeline between integrated photonic processors and the free-space world.

Displays

Tilted lidar profiling: Development and testing of a novel scanning strategy for inhomogeneous flows

The most common profiling techniques for the atmospheric boundary layer based on a monostatic Doppler wind lidar rely on the assumption of horizontal homogeneity of the flow. This assumption breaks down in the presence of either natural or human-made obstructions that can generate significant flow distortions. The need to deploy ground-based lidars near operating wind turbines for the American WAKE experimeNt (AWAKEN) spurred a search for novel profiling techniques that could avoid the influence of the flow modifications caused by the wind farms. With this goal in mind, two well-established profiling scanning strategies have been retrofitted to scan in a tilted fashion and steer the beams away from the more severely inhomogeneous region of the flow. Results from a field test at the National Renewable Energy Laboratory's 135-m meteorological tower show that the accuracy of the horizontal mean flow reconstruction is insensitive to the tilt of the scan, although higher-order wind statistics are severely deteriorated at extreme tilts mainly due to geometrical error amplification. A numerical study of the AWAKEN domain based on the Weather Research and Forecasting Model and large-eddy simulation are also conducted to test the effectiveness of tilted profiling. It is shown that a threefold reduction of the error on inflow mean wind speed can be achieved for a lidar placed at the base of the turbine using tilted profiling.

17 WIND ENERGY

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION