Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCRUBBERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Progress of Four Bed Carbon Dioxide Scrubber

The Four Bed Carbon Dioxide Scrubber flight demonstration is presently operating onboard the International Space Station. After being launched in August of 2021 and installed in October, the system has been removing metabolic CO2 from the cabin as a supplement and replacement for other CO2 systems, specifically the two Carbon Dioxide Removal Assemblies. This work describes the conclusion of the ground integration and testing campaign and the start of on orbit operations. Additionally, performance, reliability, and forward works will be summarized. Interactions of the software with off-nominal events will be discussed and how the system will be reconfigured to sustain operations.

4BCO2↗

Polycyclic aromatic hydrocarbon emission profiles and removal efficiency by electrostatic precipitator and wetfine scrubber in an iron ore sintering plant

A monitoring campaign of polychlorinated dibenzo-p-dioxins and dibenzofurans, polyaromatic hydrocarbons (PAHs), and polychlorinated biphenyl was carried out in an Italian iron ore sintering plant by sampling the combustion gases at the electrostatic precipitator (ESP) outlet, at the Wetfine scrubber (WS) outlet, and by collecting the ESP dust. Few data are available on these micropollutants produced in iron ore sintering plants, particularly from Italian plants. This study investigates the PAH emission profiles and the removal efficiency of ESPs and WS. PAHs were determined at the stack, ESP outlet flue gases, and in ESP dust to characterize the emission profiles and the performance of the ESP and the WS for reducing PAH emission. The 11 PAHs monitored are listed in the Italian legislative decree 152/2006. The mean total PAH sum concentration in the stack flue gases is 3.96 {mu}g/N m{sup 3}, in ESP outlet flue gases is 9.73 {mu}g/N m{sup 3}, and in ESP dust is 0.53 {mu}g/g. Regarding the emission profiles, the most abundant compound is benzo(b)fluoranthene, which has a relative low BaP toxic equivalency factors (TEF) value, followed by dibenzo(a,l)pyrene, which has a very high BaP(TEF) value. The emission profiles in ESP dust and in the flue gases after the ESP show some changes, whereas the fingerprint in ESP and stack flue gases is very similar. The removal efficiency of the ESP and of WS on the total PAH concentration is 5.2 and 59.5%, respectively. 2 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Update: what's that scrubber going to cost?

Power published a summary of the flue gas desulfurization system scrubber cost survey conducted by the EUCG's Fossil Productivity Committee in the July 2007 issue. Although the detailed results of the latest survey are proprietary to EUCG members that participated in it, the paper presents the newest summary data. The bottom line is costs continue to rise but appear to be more predictable. 7 figs.

01 COAL, LIGNITE, AND PEAT↗

Waste Treatment and Immobilization Plant U. S. Department of Energy Office of River Protection Submerged Bed Scrubber Condensate Disposition Project - 13460

The Hanford Waste Treatment and Immobilization Plant (WTP) will generate an off-gas treatment system secondary liquid waste stream [submerged bed scrubber (SBS) condensate], which is currently planned for recycle back to the WTP Low Activity Waste (LAW) melter. This SBS condensate waste stream is high in Tc-99, which is not efficiently captured in the vitrified glass matrix [1]. A pre-conceptual engineering study was prepared in fiscal year 2012 to evaluate alternate flow paths for melter off-gas secondary liquid waste generated by the WTP LAW facility [2]. This study evaluated alternatives for direct off-site disposal of this SBS without pre-treatment, which mitigates potential issues associated with recycling. This study [2] concluded that SBS direct disposal is a viable option to the WTP baseline. The results show: - Off-site transportation and disposal of the SBS condensate is achievable and cost effective. - Reduction of approximately 4,325 vitrified WTP Low Activity Waste canisters could be realized. - Positive WTP operational impacts; minimal WTP construction impacts are realized. - Reduction of mass flow from the LAW Facility to the Pretreatment Facility by 66%. - Improved Double Shell Tank (DST) space management is a benefit. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Review of Submerged Bed Scrubber Assumptions in the Hanford Waste Treatment and Immobilization Plant Bases and Requirements Document

A review was performed of the assumptions in the Hanford Waste Treatment and Immobilization Plant Bases and Requirements Document (BARD) for the Low Activity Waste (LAW) Submerged Bed Scrubber (SBS). This review was performed to evaluate how the assumptions impact the TOPSim process models that utilize the assumptions for system modeling. The RPP Integrated Flowsheet uses TOPSim to model the entire waste retrieval and treatment process for the Hanford tank waste. This model relies on a number of inputs, including the BARD. The BARD represents the basis for the WTP process models; as such, it contains some assumptions that are valid for the models that will not accurately reflect actual operation. For example, the amount of LAW condensate generated is overstated in the BARD to allow for conservatism in the design of the condensate handling unit operations. The assumptions in the BARD for the LAW SBS were reviewed to evaluate how actual operation could differ from the design basis assumptions. It should be noted that this review did not evaluate nor is it intended to address issues related to design of the WTP facility such that the information in this report is should not be viewed as issues with the design of the WTP facility nor should the information be used without additional evaluation to generate design concerns.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultimate disposal of scrubber wastes

Part of the initial concern with using the wet scrubbers on the hypergolic propellants was the subsequential disposal of the liquid wastes. To do this, consideration was given to all possible methods to reduce the volume of the wastes and stay within the guidelines established by the state and federal environmental protection agencies. One method that was proposed was the use of water hyacinths in disposal ponds to reduce the waste concentration in the effluent to less than EPA tolerable levels. This method was under consideration and even in use by private industry, municipal governments, and NASA for upgrading existing wastewater treatment facilities to a tertiary system. The use of water hyacinths in disposal ponds appears to be a very cost-effective method for reduction and disposal of hypergolic propellants.

Cohenour, B. C.↗

Spacelab scrubber analysis and test support

Contaminants to be used in qualification and development tests of the add-on charcoal bed scrubber were established, along with rates and methods for their introduction. The contaminant levels to be achieved were predicted and test results were analyzed.

Source record↗

Improved aqueous scrubber for collection of soluble atmospheric trace gases

A new concentration technique for the extraction and enrichment of water-soluble atmospheric trace gases has been developed. The gas scrubbing technique efficiently extracts soluble gases from a large volume flow rate of air sample into a small volume of refluxed trapping solution. The gas scrubber utilizes a small nebulizing nozzle that mixes the incoming air with an aqueous extracting solution to form an air/droplet mist. The mist provides excellent interfacial surface areas for mass transfer. The resulting mist sprays upward through the reaction chamber until it impinges upon a hydrophobic membrane that virtually blocks the passage of droplets but offers little resistance to the existing gas flow. Droplets containing the scrubbed gases coalesce on the membrane and drip back into the reservoir for further refluxing. After a suitable concentration period, the extracting solution containing the analyte can be withdrawn for analysis. The nebulization-reflex concentration technique is more efficient (maximum flow of gas through the minimum volume of extractant) than conventional bubbler/impinger gas extraction techniques and is offered as an alternative method.

Cofer, W. R., III↗

Investigation of new hypergol scrubber technology

The ultimate goal of this work is to minimize the liquid waste generated from the scrubbing of hypergolic vent gases. In particular, nitrogen tetroxide, a strong oxidizer used in hypergolic propellant systems, is currently scrubbed with a sodium hydroxide solution resulting in a hazardous liquid waste. This study investigated the use of a solution of potassium hydroxide and hydrogen peroxide for the nitrogen textroxide vent scrubber system. The potassium nitrate formed would be potentially usable as a fertilizer. The hydrogen peroxide is added to convert the potassium nitrite that is formed into more potassium nitrate. Smallscale laboratory tests were conducted to establish the stability of hydrogen peroxide in the proposed scrubbing solution and to evaluate the effectiveness of hydrogen peroxide in converting nitrite to nitrate.

Glasscock, Barbara H.↗

High Temperature Life Testing of 80Ni-20Cr Wire in a Simulated Mars Atmosphere for the Sample Analysis at Mars (SAM) Instrument Suite Gas Processing System (GPS) Carbon Dioxide Scrubber

In support of the GPS for the SAM instrument suite built by NASA/GSFC, a life test facility was developed to test the suitability of 80Ni-20Cr alloy wire, 0.0142 cm diameter, for use as a heater element for the carbon dioxide scrubber. The element would be required to operate at 1000 C in order to attain the 800 C required for regeneration of the getter. The element also would need to operate in the Mars atmosphere, which consists mostly of CO2 at pressures between 4 and 12 torr. Data on the high temperature degradation mechanism of 80Ni- 20Cr in low pressure CO2, coupled with the effects of thermal cycling, were unknown. In addition, the influence of work hardening of the wire during assembly and the potential for catastrophic grain growth also were unknown. Verification of the element reliability as defined by the mission goals required the construction of a test facility that would accurately simulate the duty cycles in a simulated Mars atmosphere. The experimental set-up, along with the test protocol and results will be described.

Hoffman, Christopher↗

High Temperature Life Testing of 80Ni-20Cr Wire in a Simulated Mars Atmosphere for the Sample Analysis at Mars (SAM) Instrument Suit Gas Processing System (GPS) Carbon Dioxide Scrubber

In support of the GPS for the SAM instrument suite built by GSFC, a life test facility was developed to test the suitability of 80Ni-20Cr wire, 0.0056 inches in diameter, for use as a heater element for the carbon dioxide scrubber. The wire would be required to operate at 1000 C in order to attain the 800 C required for regeneration of the getter. The wire also would need to operate in the Mars atmosphere, which consists mostly of CO2 at pressures between 4 and 12 torr. Data on the high temperature degradation mechanism of 80Ni-20Cr in low pressure CO2, together with the effects of thermal cycling, were unknown. In addition, the influence of work hardening of the wire during assembly and the potential for catastrophic grain growth also were unknown. Verification of the wire reliability as defined by the mission goals required the construction of a test facility that would accurately simulate the duty cycles in a simulated Mars atmosphere. The experimental set-up, along with the test protocol and results will be described.

Gundersen, Cynthia↗

Swing Bed Scrubber Design and Test Integration Results for Carbon Dioxide Removal in the Ventilation Test Loop 2.0

NASA is developing an advanced portable life support system (PLSS) to meet the needs of a new NASA advanced space suit. The PLSS provides the necessary oxygen, ventilation, and thermal protection for an astronaut performing a spacewalk. The PLSS ventilation subsystem is responsible for providing adequate carbon dioxide (CO2) and water vapor removal. To experimentally validate the performance of CO2 removal and advanced CO2 sensing systems, NASA Johnson Space Center developed the Ventilation Test Loop 2.0 (VTL2) and tested the Oceaneering Swing Bed Scrubber (SBS) that was fabricated and delivered under the Constellation Space Suit System Contract in 2015. The SBS was designed to continuously remove CO2 and water vapor from a space suit ventilation loop with a pair of thermally integrated amine beds that alternately adsorb and desorb water vapor and CO2. The SBS hardware was recently resurrected and reassembled to support a full battery of performance testing in the VTL2. This paper describes the design and development of the SBS and the VTL2 along with the performance test results of the SBS.

Ventilation Test Loop↗

4-Bed CO2 Scrubber – From Design to Build

Four-bed technology is an International Space Station (ISS) mainstay for metabolic Carbon Dioxide (CO2) removal and crew life support. The current generation is known as the Carbon Dioxide Removal Assembly (CDRA) and has a long history of unplanned maintenance as well as obsolete core components. The 4-bed CO2 Scrubber was commissioned to operate with no unplanned maintenance for 3 years while removing 4 crew-equivalents of CO2 at a target inlet concentration of 2 torr CO2. This work goes into detail of the various design aspects that have been undertaken to ensure a successful project design and successful build leading to an upcoming flight. This work will discuss the compromises caught both early and late in the design cycle and the adaptations in response. Finally, the expected performance of the system once launched will be discussed based on summaries of data from the testbed.

Carbon Dioxide↗

Thermal Design Challenges Posed by the Four Bed CO2 Scrubber COTS Air-Save Pump

The Four Bed Carbon Dioxide (4BCO2) scrubber Air-Save Pump (ASP) operates as part of the adsorbent bed regeneration cycle. The ASP removes residual air from the bed for return to the cabin prior to heat and vacuum exposure which drives out the CO2 regenerating the bed. 4BCO2 employs a Commercial Off-the-Shelf (COTS) scroll type air pump, repackaged in an acoustically insulated enclosure to reduce noise and mounted to a cold plate. The International Space Station (ISS) Low Temperature Loop (LTL) flow (operating between 38°F and 50°F) first cools the process air, and then flows through the cold plate, cooling the pump. This results in competing ASP thermal design goals: (1) to keep the pump and motor sufficiently cool and (2) to avoid forming condensation due to over-cooling. Surfaces below 60°F typically warrant careful consideration of condensation. A test-calibrated thermal model demonstrates such a balanced design is feasible with temperatures above 60°F. A separate, coupled fluid model predicts the potential for condensation formation, allowing risk assessment of flying with the unmodified design.

Daniel P Popok↗

Performance of the Four Bed Carbon Dioxide Scrubber ISS Technology Demonstration

The Four Bed Carbon Dioxide Scrubber technology demonstration is presently operating onboard the International Space Station after being launched in August of 2021and activated in October. This work describes the ground and flight performance of the 4BCO2 and the methods used to determine performance on the ISS where limited sensor data is available.

Life Support↗

Status of the Four Bed Carbon Dioxide Scrubber ISS Technology Demonstration

The Four Bed Carbon Dioxide Scrubber flight demonstration is presently operating onboard the International Space Station. After being launched in August and activated in September 2021, the system has been removing metabolic CO2 from the cabin as a supplement and replacement for other CO2 removal systems, specifically the two Carbon Dioxide Removal Assemblies. This paper describes on-orbit operations and changes (including installation of the Calnetix blower) during 2022 and early 2023. Performance of the system especially as affected by changes in the on-orbit configuration will be described. System reliability, software changes, and ongoing efforts will be summarized.

Life Support↗