Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Scintillator Library: A database of inorganic and organic scintillator properties

The Scintillator Library (scintillator.lbl.gov) is a database of scintillator properties hosted by Lawrence Berkeley National Laboratory in a web-accessible format. It contains a variety of measured inorganic and organic scintillator properties extracted from peer-reviewed literature and manufacturer specifications. Data housed within the Scintillator Library supply an important resource for developers of scintillator-based detection systems and an aid for scientists seeking to establish connections between fundamental material and chemical properties and the associated scintillation performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the scintillation response of water-based liquid scintillator to alpha particles, and implications for particle identification

Next-generation large-scale neutrino detectors, from EOS, at the 1 t scale, to THEIA, at the 10 s-of-kt scale, will utilize differences in both the scintillation and Cherenkov light emission for different particle species to perform background rejection. This manuscript presents measurements of the scintillation light yield and emission time profile of water-based liquid scintillator samples in response to α radiation. These measurements are used as input to simulation models used to make predictions for future detectors. In particular, we present the timing-based particle identification achievable in generic water-based scintillator detectors at the 4 t, 1 kt, and 100 kt scales. We find that α/β discrimination improves with increasing scintillation concentration and we identify better than 80% α rejection for 90% β acceptance in 10% water-based liquid scintillator, at the 4 t scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Crystal growth and scintillation properties of new ytterbium-activated scintillators Cs 4 CaI 6 :Yb and Cs 4 SrI 6 :Yb

Yb 2+ was investigated as a potential alternative activator for Cs 4 SrI 6 and Cs 4 CaI 6 scintillators for the first time, as opposed to the previously studied Eu2+ activator. Single crystals with nominal Yb 2+ concentrations of 0.5 mol%, 1 mol%, and 3 mol% were grown in Ø7 mm ampoules using the vertical Bridgman method. Luminescence and scintillation properties were evaluated as a function of Yb 2+ concentration and host compound. Here, the 5d → 4f electronic transition of Yb 2+ was observed for both the Sr- and Ca-containing compositions. X-ray induced radioluminescence emission was centered between 449 nm and 463 nm depending on Yb 2+ concentration and host compound. Both the spin-allowed and spin-forbidden transitions were observed in photoluminescence emission spectra and were centered at 446 nm and 476 nm, respectively, for both compounds. The best scintillation performance was achieved with Cs 4 CaI 6 :Yb 1 mol%, which had a 3.5% energy resolution at 662 keV and 43,000 ph/MeV light yield. To our knowledge this is the best energy resolution ever reported for a Yb 2+ -doped scintillator. Additional Cs 4 CaI 6 :Yb 1% crystals were grown in Ø12 mm ampoules to investigate the size dependence of scintillation properties, as well as crystal homogeneity.

36 MATERIALS SCIENCE↗

Improved growth and scintillation properties of intrinsic, non-hygroscopic scintillator Cs 2 HfCl 6

This paper focuses on recent successful and improved growth runs of single phase Cs 2 HfCl 6 (CHC) as well as improvement to its radiometric and scintillation performance. Two single crystal CHC boules of 15 mm in diameter are grown using the vertical Bridgman method. Samples retrieved from each boule are characterized for their optical and scintillation properties. Energy resolution of 2.8% (FWHM) at 662 keV has been obtained. Gamma-ray non-proportionality of CHC is compared to those of NaI:Tl and BGO. Decay times are measured to be at least 246 ns (13%) and 3.3 μs (87%) for CHC, an improvement to previously reported values. In this paper we also present growth and scintillation performance of Cs 2 Hf(Cl 1-x Br x ) 6 with Cl/Br = 2/1 relation (CHC/B), as well as its scintillation decay times.

36 MATERIALS SCIENCE↗

Measurement of Scintillation and Ionization Yield and Scintillation Pulse Shape from Nuclear Recoils in Liquid Argon

We have measured the scintillation and ionization yield of recoiling nuclei in liquid argon as a function of applied electric field by exposing a dual-phase liquid argon time projection chamber (LAr-TPC) to a low energy pulsed narrow band neutron beam produced at the Notre Dame Institute for Structure and Nuclear Astrophysics. Liquid scintillation counters were arranged to detect and identify neutrons scattered in the TPC and to select the energy of the recoiling nuclei. We also report measurements of the scintillation yields for nuclear recoils with energies from 10.3 to 57.3 keV and for median applied electric fields from 0 to 970 V/cm. For the ionization yields, we report measurements from 16.9 to 57.3 keV and for electric fields from 96.4 to 486 V/cm. Furthermore, we report the observation of an anticorrelation between scintillation and ionization from nuclear recoils, which is similar to the anticorrelation between scintillation and ionization from electron recoils. Assuming that the energy loss partitions into excitons and ion pairs from 83m Kr internal conversion electrons is comparable to that from 207 Bi conversion electrons, we obtained the numbers of excitons (N ex ) and ion pairs (N i ) and their ratio (N ex /N i ) produced by nuclear recoils from 16.9 to 57.3 keV. Motivated by arguments suggesting direction sensitivity in LAr-TPC signals due to columnar recombination, a comparison of the light and charge yield of recoils parallel and perpendicular to the applied electric field is presented for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Codoping method for modifying the scintillation and optical properties of garnet-type scintillators

A method of tailoring the properties of garnet-type scintillators to meet the particular needs of different applications is described. More particularly, codoping scintillators, such as Gd 3 Ga 3 Al 2 O 12 , Gd 3 Ga 2 Al 3 O 12 , or other rare earth gallium aluminum garnets, with different ions can modify the scintillation light yield, decay time, rise time, energy resolution, proportionality, and/or sensitivity to light exposure. Also provided are the codoped garnet-type scintillators themselves, radiation detectors and related devices comprising the codoped garnet-type scintillators, and methods of using the radiation detectors to detect gamma rays, X-rays, cosmic rays, and particles having an energy of 1 keV or greater.

Tyagi, Mohit↗

Lanthanum halide nanoparticle scintillators for nuclear radiation detection

Nanoparticles with sizes <10 nm were fabricated and characterized for their nanocomposite radiation detector properties. This work investigated the properties of several nanostructured radiation scintillators, in order to determine the viability of using scintillators employing nanostructured lanthanum trifluoride. Preliminary results of this investigation are consistent with the idea that these materials have an intrinsic response to nuclear radiation that may be correlated to the energy of the incident radiation.

36 MATERIALS SCIENCE↗

Radiopure metal-loaded liquid scintillator

Metal-loaded liquid scintillator plays a key role in particle and nuclear physics experiments. The applications of metal ions in various neutrino experiments and the purification methods for different scintillator components are discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Relationship Between Scintillation Anisotropy and Crystal Structure in Pure Crystalline Organic Scintillator Materials

We report the scintillation anisotropy effect for proton recoil events has been investigated in five pure organic crystalline materials: anthracene, trans-stilbene, p-terphenyl, bibenzyl, and diphenylacetylene. These measurements include characterization of the scintillation response for one hemisphere of proton recoil directions in each crystal. In addition to standard measurements of the total light output and pulse shape at each angle, the prompt and delayed light anisotropies are analyzed, allowing for investigation of the singlet and triplet molecular excitation behaviors independently. This work provides new quantitative and qualitative observations that make progress toward understanding the physical mechanisms behind the scintillation anisotropy. These measurements show that the relationship between the prompt and delayed light anisotropies is correlated with crystal structure, as it changes between the pi-stacked crystal structure materials (anthracene and p-terphenyl) and the herringbone crystal structure materials (stilbene, bibenzyl, and diphenylacetylene). The observations are consistent with a model in which there are preferred directions of kinetic processes for the molecular excitations. Finally, these processes and the impact of their directional dependencies on the scintillation anisotropy are discussed.

36 MATERIALS SCIENCE↗

Intrinsic scintillation performance & europium concentration effects in RbSr 2 I 5 and RbSr 2 Br 5 scintillators

Scintillators play crucial roles in homeland security applications like gamma ray spectroscopy and high energy X-ray radiography. For promising new scintillators, fine-tuning the luminescent dopant concentration is one avenue to further improve their performance and tailor their properties. In this work, the effects of europium dopant concentrations on the crystal growth, luminescence and scintillation properties of RbSr 2 Br 5 and RbSr 2 I 5 crystals was investigated. Nine transparent 7 mm diameter single crystals were grown via the Vertical Bridgman method. Here, the optical band gap of RbSr 2 Br 5 was 5.9 eV and that of RbSr 2 I 5 was 4.7 eV. High scintillation performance was achieved with a relatively low europium concentration of 1 mol%. For both RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu crystals, light yield of 60–90,000 ph/MeV, energy resolution 2.8–4.0 % at 662 keV, and X-ray afterglow 0.79–1.5 % at 2 ms were obtained.

36 MATERIALS SCIENCE↗

Developments of scintillator-based soft x-ray diagnostic in LHD with CsI:Tl and P47 scintillators

Multi-channel soft x-ray (SX) diagnostic has been used in the large helical device (LHD) to research magnetohydrodynamic equilibria and activities. However, in the coming deuterium plasma experiments of LHD, it will be difficult to use semiconductor systems near LHD. Therefore, a new type of SX diagnostic, a scintillator-based type diagnostic, has been investigated in order to avoid damage from the radiation. A fiber optic plate coated by P47 scintillator will be used to detect SX emission. Scintillation light will be transferred by pure silica core optical fibers and detected by photomultiplier tubes. A vertically elongated section of LHD will be covered by a 13 ch. array. Effects from the Deuterium Deuterium neutrons can be negligible when the scintillator is covered by a Pb plate 4 cm in thickness to avoid gamma-rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

History and current status of strontium iodide scintillators

Eu-doped strontium iodide single crystal growth has reached maturity and prototype SrI 2 (Eu)-based gamma ray spectrometers provide detection performance advantages over standard detectors. SrI 2 (Eu) offers a high, proportional light yield of >80,000 photons/MeV. Energy resolution of <3% at 662 keV with 1.5” x 1.5” SrI2(Eu) crystals is routinely achieved, by employing either a small taper at the top of the crystal or a digital readout technique. These methods overcome light-trapping, in which scintillation light is re-absorbed and re-emitted in Eu 2+ -doped crystals. As a result, its excellent energy resolution, lack of intrinsic radioactivity or toxicity, and commercial availability make SrI 2 (Eu) the ideal scintillator for use in handheld radioisotope identification devices. A 6-lb SrI 2 (Eu) radioisotope identifier is described.

36 MATERIALS SCIENCE↗

Investigation of the competition between Tl + and Ce 3+ scintillation in Tl2LiYCl6:Ce, an elpasolite scintillator

Li-containing elpasolite scintillators are currently investigated for their ability to detect both thermal neutrons and gamma photons with a single inorganic crystal. The scintillation is typically triggered by using an activator such as Ce. However, when Tl, also a luminescent ion, is present in the matrix, competition between the two centers Tl and Ce can occur. In this study, we are using Ce doped Tl 2 LiYCl 6 to investigate this competition. To this end, the Ce (which substitutes Y) concentration is varied from 0 to 1 in the Tl 2 LiY 1-x CexCl 6 composition. In the low concentration range in which Ce remains a dopant, the photo- and radioluminescence spectra show that the scintillation of Tl 2 LiYCl 6 :Ce is mostly dominated by recombination on intrinsic luminescent centers. For cerium concentrations higher than x = 0.02, very different emissions can be easily distinguished from the photo- and radioluminescence of undoped and low Ce doped Tl 2 LiYCl 6 crystals. These emissions are attributed to the formation of a second phase Tl 2 CeCl 5 , identified by X-ray diffraction. We conclude that the intrinsic luminescence related to Tl dominates the scintillation in the range of concentration for which Ce does substitute on the Y-site.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of cosmic ray scintillations from 5-minute data of the scintillations telescope Izmran and world-wide network stations

During cosmic ray propagation in interplanetary space there appear characteristic cosmic-ray intensity scintillations which are due to charged particle scattering on random inhomogeneities of the interplanetary magnetic field. The power spectra of cosmic ray scintillations on the Earth during some intervals from 1977 to 1982 (for quiet periods, for solar flares and Forbush decreases due to power shock waves) have been calculated from five-minute, one and two-hour values of the cosmic-ray intensity measured by the scintillator supertelescope IZMIRAN. The spectra were estimated by the methods of spectral analysis and by autoregressive methods which mutually control each other and make it possible not only to analyze scintillation powers at distinguished frequencies, but also to determine the behavior of spectrum slopes in some frequency ranges.

Gulinsky, O. V.↗

Energy migration and scintillation kinetics in compositionally complex (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce single crystal scintillator

It is well-established that compositional tuning through binary admixture can improve scintillation performance in several materials systems, including Ce-activated garnets. Although recent work on ternary or quaternary cation admixture shows promise, the impact of this increased compositional complexity on thermal stability and carrier-defect dynamics has not been addressed. Here, we investigate a compositionally complex garnet, (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce (GYTLAG), grown by the Czochralski method using temperature-dependent photoluminescence (PL), PL decay, and thermoluminescence (TL). PL and PL decay measurements support a thermally activated Tb 3+ -Ce 3+ energy transfer, where Tb 3+ emission dominates below 60 K, but Ce 3+ emission increases from 20-300 K. Thermal quenching of Ce 3+ emission occurs around T 50 = 508 K, with an activation energy of 0.6 eV. TL and wavelength-resolved TL spectra from 20–500 K show that GYTLAG contains similar trap groups to LuAG but with a broader distribution of glow peaks below room temperature, possibly caused by quaternary cation mixing. A combination of dose dependence, partial cleaning and initial rise, and glow curve fitting to a first order continuous Gaussian distribution model are used to understand the contribution of electronic point defects to scintillation decay and afterglow at room temperature. Furthermore, these results inform how increased compositional complexity influences recombination dynamics in garnet scintillators.

Compositionally complex↗

A liquid scintillation detector for radioassay of gadolinium-loaded liquid scintillator for the LZ Outer Detector

© 2019 Elsevier B.V. We report on the design and performance of the LUX-ZEPLIN (LZ) “Screener”, a small liquid scintillator detector consisting of ≈23 kg of LAB-based gadolinium-loaded liquid scintillator (GdLS) to be used in the LZ Outer Detector. The Outer Detector will be filled with 17.3 tonnes of GdLS and will surround the central liquid xenon time projection chamber of LZ. Its primary function will be to tag neutron events in the liquid xenon which could mimic a WIMP dark matter signal. To meet the deadtime requirements for the Outer Detector, the radioimpurity levels in the GdLS must be kept below ≲0.07 mBq/kg. This background level corresponds to a rate of ≈50Hz above an energy threshold of 100 keV. The Screener was operated in the ultra-low-background environment of the former LUX water shield in the Davis Laboratory at the Sanford Underground Research Facility for radioassay of the GdLS. Careful selection of detector materials and use of ultra-low-background PMTs allows the measurement of a variety of radioimpurities. The 14C/12C ratio in the scintillator is measured to be (2.83±0.06(stat.)±0.01(sys.))×10 -17 . Use of pulse shape discrimination allows the concentration of isotopes throughout the 238U, 235U, and 232Th chains to be measured by fitting the collected spectra from α and β events. We find that equilibrium is broken in the 238U and 232Th chains and that a significant portion of the contamination in the GdLS results from decays in the 227Ac subchain of the 235U series. Predictions for the singles rate in the Outer Detector are presented. The rate from radioimpurities above 100 keV in the GdLS is estimated to be 97.9±6.4Hz, with 65.5±1.9Hz resulting from α-decays.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗