Engineering PapersSearch

SEARCH · Engineering Papers

Results for “SCANNING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Topography and transport properties of oligo(phenylene ethynylene) molecular wires studied by scanning tunneling microscopy

Conjugated phenylene(ethynylene) molecular wires are of interest as potential candidates for molecular electronic devices. Scanning tunneling microscopic study of the topography and current-voltage (I-V) characteristics of self-assembled monolayers of two types of molecular wires are presented here. The study shows that the topography and I-Vs, for small scan voltages, of the two wires are quite similar and that the electronic and structural changes introduced by the substitution of an electronegative N atom in the central phenyl ring of these wires does not significantly alter the self-assembly or the transport properties.

Polymers/chemistry

Development of the Double Etalon Fabry-Perot Interferometer for Determining Total and Tropospheric Ozone Concentrations

Measuring and understanding the distribution of ozone through the lower levels of Earth's atmosphere are high priorities in global change and climate research. Of particular interest now is the global distribution of ozone in the upper troposphere and lower stratosphere. Global coverage of the stratospheric ozone is feasible only via remote sensing instruments on a space-based platform. And though extensive monitoring tropospheric ozone is possible using instruments flown aboard conventional aircraft, a space-based system would be significantly less costly and provide information over a much broader area and produce more uniform coverage. Here we describe the prototype of an instrument being developed to monitor, from an orbiting spacecraft, the ozone found in Earth's upper troposphere and lower stratosphere. Our new spectrometer is an infrared Fabry-Perot interferometer which uses two synchrounously tuned etalons: a high resolution narrow band device and a lower resolution broader band filtering etalon. The prototype is a scanning device making use of nearly collimated input radiation and a single element detector. As presently configured, it is capable of providing a resolution better than 0.07/cm with a spectral band width approximately 5/cm wide and centered at 1054.7/cm. For the future space-based emission device a modification of the the prototype was to be made to employ innovative circle-to-line detector optics, those developed or in development at UM/SPRL, and a focal plane array detector. These enhancements would enable a simultaneous recording of the entire spectral range of interest, but with simple detection electronics and a significant gain in signal-to-noise over that of the scanning version.

Cook, William

Nm-scale electrical resistance imaging on CdTe by scanning spreading resistance microscopy

Local resistance imaging can provide information on nm-scale carrier distribution in semiconductor devices. Scanning spreading resistance microscopy (SSRM), an atomic force microscopy-based nm-scale resistance mapping technique, has been developed for carrier delineation in Si microdevices. We report on the development and validation of SSRM on CdTe materials, by testing on molecular beam epitaxy (MBE) grown CdTe films. The probe/CdTe contact resistance was suppressed sufficiently below sample's spreading resistance by pressing the probe into the sample with ∼mN contact force and applying a large sample/probe forward bias voltage (V s ), which was understood by analyzing current-voltage (I-V) involving a serially connected insulating top layer with underlying spreading resistance. The carrier concentration as deduced from the resistance measurement, using a single mobility value, is consistent with Hall measurement with a standard deviation of 14% based on a set of MBE films with carrier concentrations in the range of 10 15 –10 16 /cm 3 . The doping polarity was readily identified by flipping V s polarity, where the resistance with reverse V s is orders of magnitude larger than forward V s . While focusing on the SSRM technique validation, we also show an example on an As-doped Cd(Se,Te) polycrystalline thin film of a high-performance CdTe solar cell, which illustrates the local resistance nonuniformity with up to two orders of magnitude differences, indicating if local mobility is roughly constant, local carrier concentration can have significant nonuniformity.

14 SOLAR ENERGY

Effective use of remote sensing products in litigation

A boiled-down version of major legal principles affecting the admissibility of data and products from remote sensing devices is presented. It is suggested that enhancements or classifications of digital data (from scanning devices or from digitized aerial photography) be proffered as evidence in a fashion similar to the manner in which maps from photogrammetric techniques are introduced as evidence. Every effort should be made to illucidate the processes by which digital data are analytically treated or manipulated. Remote sensing expert witnesses should be practiced in providing concise and clear explanations of both data and methods. Special emphasis should be placed on being prepared to provide a detailed accounting of steps taken to calibrate and verify spectral characteristics with ground truth.

Jaynes, R. A.

Mechanical planetary compensating drive system

Drive enables two concentric output shafts to be controlled independently or rotated as a unit. Possible uses are pointing and tracking devices, rotary camera shutters with variable light control, gimbal systems with yaw and pitch movement, spectrometer mirror scanning devices, etc.

Zeiger, R. J.

Auditory display for the blind

A system for providing an auditory display of two-dimensional patterns as an aid to the blind is described. It includes a scanning device for producing first and second voltages respectively indicative of the vertical and horizontal positions of the scan and a further voltage indicative of the intensity at each point of the scan and hence of the presence or absence of the pattern at that point. The voltage related to scan intensity controls transmission of the sounds to the subject so that the subject knows that a portion of the pattern is being encountered by the scan when a tone is heard, the subject determining the position of this portion of the pattern in space by the frequency and interaural difference information contained in the tone.

Fish, R. M.

Surface reconstruction from scattered data through pruning of unstructured grids

This paper describes an algorithm for reconstructing a surface from a randomly digitized object. Scan data (treated as a cloud of points) is first tesselated out to its convex hull using Delaunay triangulation. The line-of-sight between each surface point and the scanning device is traversed, and any tetrahedra which are pierced by it are removed. The remaining tetrahedra form an approximate solid model of the scanned object. Due to the inherently limited resolution of any scan, this algorithm requires two additional procedures to produce a smooth, polyhedral surface: one process removes long, narrow tetrahedra which span indentations in the surface between digitized points; the other smooths sharp edges. The results for a moderately resolved sample body and a highly resolved aircraft are displayed.

Maksymiuk, C. M.

Computer enhancement of radiographs

Examination of three relevant noise processes and the image degradation associated with Marshall Space Flight Center's (MSFC) X-ray/scanning system was conducted for application to computer enhancement of radiographs using MSFC's digital filtering techniques. Graininess of type M, R single coat and R double coat X-ray films was quantified as a function of density level using root-mean-square (RMS) granularity. Quantum mottle (including film grain) was quantified as a function of the above film types, exposure level, specimen material and thickness, and film density using RMS granularity and power spectral density (PSD). For various neutral-density levels the scanning device used in digital conversion of radiographs was examined for noise characteristics which were quantified by RMS granularity and PSD. Image degradation of the entire pre-enhancement system (MG-150 X-ray device; film; and optronics scanner) was measured using edge targets to generate modulation transfer functions (MTF). The four parameters were examined as a function of scanning aperture sizes of approximately 12.5 25 and 50 microns.

Dekaney, A.

Soft X-ray and XUV imaging with a charge-coupled device /CCD/-based detector

A soft X-ray/XUV imaging camera which uses a thinned, back-illuminated, all-buried channel RCA CCD for radiation sensing has been built and tested. The camera is a slow-scan device which makes possible frame integration if necessary. The detection characteristics of the device have been tested over the 15-1500 eV range. The response was linear with exposure up to 0.2-0.4 erg/sq cm; saturation occurred at greater exposures. Attention is given to attempts to resolve single photons with energies of 1.5 keV.

Loter, N. G.

Infrared Images

Earth objects emit natural radiation invisible to the unaided human eye, but visible to infrared scanning devices such as the device developed by Inframetrics, Inc. Such devices serve a number of purposes ranging from detection of heat loss in buildings for energy conservation measures, to examining heat output of industrial machinery for trouble shooting and preventive maintenance. Representative of system is Model 525, a small, lightweight field instrument that scans infrared radiation and translates its findings to a TV picture of the temperature pattern in the scene being viewed. An accessory device permits viewing the thermal radiation in color.

Source record

The facsimile camera - Its potential as a planetary lander imaging system

The facsimile camera is an optical-mechanical scanning device which is an attractive candidate for planetary lander imaging systems and has been selected for the Viking/Mars mission because of its light weight, small size, and low power requirement. Other advantages are that it can provide good radiometric and photogrammetric accuracy because the complete field of view is scanned with a single photodetector located on or near the optical axis of the objective lens. In addition, this device has the potential capability of multispectral imaging and spectrometric measurements.

Huck, F. O.

Spinoff 2012

Topics covered include: Water Treatment Technologies Inspire Healthy Beverages; Dietary Formulas Fortify Antioxidant Supplements; Rovers Pave the Way for Hospital Robots; Dry Electrodes Facilitate Remote Health Monitoring; Telescope Innovations Improve Speed, Accuracy of Eye Surgery; Superconductors Enable Lower Cost MRI Systems; Anti-Icing Formulas Prevent Train Delays; Shuttle Repair Tools Automate Vehicle Maintenance; Pressure-Sensitive Paints Advance Rotorcraft Design Testing; Speech Recognition Interfaces Improve Flight Safety; Polymers Advance Heat Management Materials for Vehicles; Wireless Sensors Pinpoint Rotorcraft Troubles; Ultrasonic Detectors Safely Identify Dangerous, Costly Leaks; Detectors Ensure Function, Safety of Aircraft Wiring; Emergency Systems Save Tens of Thousands of Lives; Oxygen Assessments Ensure Safer Medical Devices; Collaborative Platforms Aid Emergency Decision Making; Space-Inspired Trailers Encourage Exploration on Earth; Ultra-Thin Coatings Beautify Art; Spacesuit Materials Add Comfort to Undergarments; Gigapixel Images Connect Sports Teams with Fans; Satellite Maps Deliver More Realistic Gaming; Elemental Scanning Devices Authenticate Works of Art; Microradiometers Reveal Ocean Health, Climate Change; Sensors Enable Plants to Text Message Farmers; Efficient Cells Cut the Cost of Solar Power; Shuttle Topography Data Inform Solar Power Analysis; Photocatalytic Solutions Create Self-Cleaning Surfaces; Concentrators Enhance Solar Power Systems; Innovative Coatings Potentially Lower Facility Maintenance Costs; Simulation Packages Expand Aircraft Design Options; Web Solutions Inspire Cloud Computing Software; Behavior Prediction Tools Strengthen Nanoelectronics; Power Converters Secure Electronics in Harsh Environments; Diagnostics Tools Identify Faults Prior to Failure; Archiving Innovations Preserve Essential Historical Records; Meter Designs Reduce Operation Costs for Industry; Commercial Platforms Allow Affordable Space Research; Fiber Optics Deliver Real-Time Structural Monitoring; Camera Systems Rapidly Scan Large Structures; Terahertz Lasers Reveal Information for 3D Images; Thin Films Protect Electronics from Heat and Radiation; Interferometers Sharpen Measurements for Better Telescopes; and Vision Systems Illuminate Industrial Processes.

Source record

The diffraction grating - An opinionated appraisal.

As a dispersing device for spectroscopy, the prism was by 1950 being supplanted by the diffraction grating, which provided broader spectrum coverage, gave higher intrinsic dispersion, and was more flexible to use. Today most gratings are three-dimensional and blazed, being embossed with thousands of identical mirrors. The relative merits of gratings in comparison with new interferometric scanning devices are examined, taking into account Fourier spectroscopy. Problems of grating ruling are discussed together with the status of ruling engines, and questions of ruling with mechanical engines.

Harrison, G. R.

Conically scanned holographic lidar telescope

An optical scanning device utilizing a source of optical energy such as laser light backscattered from the earth's atmosphere or transmitted outward as in a lidar, a rotating holographic optical element having an axis of rotation perpendicular to the plane of its substrate, and having a stationary focus which may or may not be located on its axis of rotation, with the holographic optical element diffracting the source of optical energy at an angle to its rotation axis enabling a conical scanning area and a motor for supporting and rotating the rotating holographic optical element, is described.

Schwemmer, Geary

Trial of a slant visual range measuring device

Each year, fog at airports renders some landing operations either difficult or impossible. The visibility that a pilot of a landing aircraft can expect is in that case the most important information. It could happen that the visibility versus the altitude is constantly decreasing or increasing. However, it is not possible to distinguish this with the existing sensors at an airport. If the visibility is decreasing with the altitude, one has the worst case - ground fog. The standard visibility sensor, the transmissometer, determines only the horizontal visual range, which will be underestimated in comparison with the real visibility a pilot has on his landing approach. Described here is a new technique to measure the slant visual range, making use of a slant scanning device - an eye-safe laser radar. A comparison with commercial visibility sensors shows that it is possible to measure visibilities with the slant looking laser radar in the range from 50 meters up to 2000 meters and even distinguish inhomogenities like ground fog.

Streicher, J.