Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE HOLDERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Extending accurate spectral induced polarization measurements into the kHz range: modelling and removal of errors from interactions between the parasitic capacitive coupling and the sample holder

SUMMARY Spectral induced polarization (SIP), describing the measurement of the frequency domain electrical impedance magnitude and phase of porous materials, has been widely used to characterize subsurface hydrological/biogeochemical properties and processes. SIP data collected at frequencies higher than 100 Hz are expected to describe the polarization of small particles providing insights into the physicochemical properties of clays, nanoparticles and microorganisms. However, the phase measurements at these high frequencies are often contaminated by errors due to the parasitic capacitive coupling of the SIP instrument, especially for lower conductivity samples. We developed a model showing the measured phase is the sum of the true sample phase and an error term ωCinZx, where ω is the angular frequency; Cin is the instrument input capacitance and Zx is a measurable impedance function related to the sample holder properties and the reference resistor. Based on this model, a new phase correction method is proposed that results in highly accurate SIP data up to 20 kHz as well as the determination of Cin. We tested the correction method using electric circuits, NaCl fluids and three unconsolidated samples (sand, sand-clay and sand-pyrite mixtures). The corrected phase for the circuit and NaCl fluid experiments showed excellent agreement with the theoretical phase response across the studied frequency range (errors <1 mrad). For unconsolidated samples, removal of errors results in phase spectra more consistent with expected polarization mechanisms, as based on phase peaks recorded for small pyrite and clay particles at high frequencies. These phase peaks could not be identified in the uncorrected data. Our approach can substantially enhance the value of the SIP method for the characterization of fine-grained sediments and rocks.

58 GEOSCIENCES↗

Sample Holder for Cryogenic Adhesive Shear Test

Five samples tested in one cooldown. Holder mounted in testing machine. Submerged in cryogenic liquid held in cryostat. Movable crosshead of testing machine moves gradually downward. Samples placed under tension, one after another, starting with top one; each sample fails in turn before next is stressed.

Ledbetter, F. E.↗

An evaluation of adhesive sample holders for advanced crystallographic experiments

Commercially available adhesives have been evaluated for crystal mounting when undertaking complex macromolecular crystallography experiments. Here, their use as tools for advanced sample mounting and cryoprotection is assessed and their suitability for room-temperature data-collection and humidity-controlled studies is investigated. The hydration state of macromolecular crystals often affects their overall order and, ultimately, the quality of the X-ray diffraction pattern that they produce. Post-crystallization techniques that alter the solvent content of a crystal may induce rearrangement within the three-dimensional array making up the crystal, possibly resulting in more ordered packing. The hydration state of a crystal can be manipulated by exposing it to a stream of air at controlled relative humidity in which the crystal can equilibrate. This approach provides a way of exploring crystal hydration space to assess the diffraction capabilities of existing crystals. A key requirement of these experiments is to expose the crystal directly to the dehydrating environment by having the minimum amount of residual mother liquor around it. This is usually achieved by placing the crystal on a flat porous support (Kapton mesh) and removing excess liquid by wicking. Here, an alternative approach is considered whereby crystals are harvested using adhesives that capture naked crystals directly from their crystallization drop, reducing the process to a one-step procedure. The impact of using adhesives to ease the harvesting of different types of crystals is presented together with their contribution to background scattering and their usefulness in dehydration experiments. It is concluded that adhesive supports represent a valuable tool for mounting macromolecular crystals to be used in humidity-controlled experiments and to improve signal-to-noise ratios in diffraction experiments, and how they can protect crystals from modifications in the sample environment is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic pulser and sample holder for time- and spin-resolved photoemission spectroscopy on magnetic materials

A compact coil setup, in conjunction with a high power current pulser, is presented; developed especially for time- and spin-resolved photoemission spectroscopy measuring the sample in magnetic remanence at room temperature. A novel approach is presented where the sample is switched in the stray field of a coil pair. This enables the electrical biasing of the sample without altering the electron trajectories due to field gradients introduced by the coils. The pulser driving the coils reaches a peak power of 1 MW at 1 kA with a switching frequency up to 10 kHz suitable for experiments, for example, with state of the art repetition rates of femtosecond laser systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fully contained sample holder capable of electron-yield detection at soft X-ray energies

A holder has been developed that enables electron yield-detected soft X-ray spectroscopy of fully contained samples at low temperature. Crucially, this design uses elements of the sample containment to collect ejected electrons, removing the need to expose samples directly to the vacuum environment of the spectrometer. The design is modular and should be adaptable to a number of different endstation configurations, enabling spectroscopy of air-sensitive, radioactive and vacuum-sensitive (biological) samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The effect of sample holder material on ion mobility spectrometry reproducibility

When a positive detection of a narcotic occurs during the search of a vessel, a decision has to be made whether further intensive search is warranted. This decision is based in part on the results of a second sample collected from the same area. Therefore, the reproducibility of both sampling and instrumental analysis is critical in terms of justifying an in depth search. As reported at the 2nd Annual IMS Conference in Quebec City, the U.S. Coast Guard has determined that when paper is utilized as the sample desorption medium for the Barringer IONSCAN, the analytical results using standard reference samples are reproducible. A study was conducted utilizing papers of varying pore sizes and comparing their performance as a desorption material relative to the standard Barringer 50 micron Teflon. Nominal pore sizes ranged from 30 microns down to 2 microns. Results indicate that there is some peak instability in the first two to three windows during the analysis. The severity of the instability was observed to increase as the pore size of the paper is decreased. However, the observed peak instability does not create a situation that results in a decreased reliability or reproducibility in the analytical result.

Jadamec, J. Richard↗

A Tear-Drop Bifilar Sample Holder for Full Excitation and Stability Studies of HTS Cables at 4.2 K Using a Superconducting Transformer

HTS cables proposed for next-generation main, hybrid, and insert magnets will have very high I c (>10 kA) at 14 T and above. Determining the quench, current-sharing, and other properties of these cables will require measurement systems, which will likely incorporate a superconducting transformer. The utilization of high-field persistent mode solenoids will make size and cost less prohibitive, allowing a higher frequency of measurements within a larger number of research facilities. Additionally, a system designed for use with solenoids will allow for experiments at higher maximum fields than those achievable using dipoles and split coils. Proposed in this document is a bifilar sample probe, which fits within a 77-mm bore solenoid capable of measuring up to a 6-mm outer diameter conductor-on-round-core REBCO cables or wires up to 20 kA in transverse fields at 12 T and 4.2 K. Further, splices and mechanical considerations will be discussed.

43 PARTICLE ACCELERATORS↗

Multiple-sample holder for IC testing

Carrousel tray speeds up testing process by feeding mass spectrometer up to 12 sealed integrated circuit packages in rapid succession for analysis of contaminants and total gas composition.

Haack, R. F.↗