Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ross filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

ARM West Antarctic Radiation Experiment (AWARE) Fourier Transform Infrared Filter Sampling Systems Field Campaign Report

West Antarctica is one of the most rapidly warming regions in the world (Bromwich et al. 2013; Steig et al. 2009) and the warming can directly cause sea level rise (King et al. 2012). In situ measurements are needed to examine and quantify the meteorological conditions in order to precisely understand the effect of warm air and clouds on the West Antarctic Ice Shelf (WAIS). The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment (AWARE) is designed to collect measurements with advanced cloud and aerosol instrumentation at West Antarctica. The Fourier Transform Infrared (FTIR) filter sampling systems were deployed as part of the ARM West Antarctic Radiation Experiment (AWARE) campaign to measure organic aerosol characteristics at McMurdo Station. As a coastal station at the southern end of Ross Island, McMurdo Station has a meteorological relationship with the WAIS via circulation patterns in the Ross and Amundsen Seas. Thirteen months of continuous observations of aerosol particle composition extended from December 2016 to January 2017. Filter samples were collected at McMurdo on pre-scanned Teflon filters (Teflon, Pall Inc., 37mm diameter) behind PM1 sharp-cut cyclones (SCC2.229 PM1, BGI Inc). Samples were collected each week with approximately 50-90 m3 air filtered per sample. Samples were frozen and transported below 0°C to the Scripps laboratory for FTIR spectroscopy analysis. A Bruker Tensor 27 FTIR spectrometer with a deuterated triglycine sulfate (DTGS) detector (Bruker, Waltham, MA) was used to scan the filters both before and after sampling. An automated algorithm (Takahama et al. 2013) was applied to quantify the mass of the organic functional groups. Four groups (alkane, amine, alcohol, and carboxylic acid) had absorption peaks above the limits of quantification, and the sum of the mass of the four functional groups is the quantified organic mass (OM). Absorption peaks for other groups (organosulfate, organonitrate, aromatic, and alkene group) were identified and fit but they were below the limit of quantification for more than 90% of the samples and are excluded. Similar FTIR measurements has been conducted in dozens of field campaigns around the world, including arctic regions (Russell et al. 2011). Local particle emissions from airports, diesel generators, and local transportation affected all aerosol measurements at various times during this project. The ARM Aerosol Measurement Science Group is aware of the issue and is working to develop algorithms to flag the data. This influence is evident in the FTIR measurements as it is associated with specific chemical signatures. DOE and the National Science Foundation, which manages the U.S. Antarctic Program, supported this collaboration for AWARE.

ARM West Antarctic Radiation Experiment, Fourier T↗

A Strategy for Forced Oscillation Suppression

Wide-area time-synchronized measurements have recently revealed troublesome forced oscillations (FOs) within modern synchronized power grids. In some cases, these FOs represent a dangerous hazard to the system. Recent research has focused on locating the source of FOs to provide operators with knowledge for mitigating their impact locally. This paper presents a complementary mitigation strategy, which is to purposely induce a second oscillation into the grid which cancels the impact of the FO. Such a strategy is complementary in that it may provide valuable time to operators attempting to locate the FOs source and to determine how to rectify it. This paper presents a suppression control strategy which modulates controllable devices to automatically cancel the impact of the FO without the need for locating the source of the original FO. The strategy is based upon tuned feedback control. In this study, the approach is demonstrated on a simulation system via modulation of inverter-based generation.

42 ENGINEERING↗

Ceramic High Efficiency Particulate Air (HEPA) Filter Research and Development at Lawrence Livermore National Laboratory

Ceramic high efficiency particulate air (HEPA) filter development program began at Lawrence Livermore National Laboratory (LLNL) over 20 years ago. Historical incidents motivated current safety systems at nuclear facilities. A ceramic filter that can survive a fire can provide robust, passive safety protection. Research has been conducted to improve the safety of nuclear facilities and to reduce operational and lifecycle costs, through ceramic filter technology that can survive fire conditions. Here, the research focused on applications in both new facilities as well as meeting operational requirements necessary to retrofit filters into existing DOE facilities. The research has developed multiple filter technologies spanning traditional HEPA filter materials to advanced manufacturing technologies (e.g., electrospinning, additive manufacturing, etc.). This communication will present highlights of selected development efforts for ceramic HEPA filter research, current state-of-the-art for ceramic filters, and future needs including technical, regulatory, and commercial efforts.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-energy x-ray backlighter spectrum measurements using calibrated image plates

The x-ray spectrum between 18 and 88 keV generated by a petawatt laser driven x-ray backlighter target was measured using a 12-channel differential filter pair spectrometer. The spectrometer consists of a series of filter pairs on a Ta mask coupled with an x-ray sensitive image plate. A calibration of Fuji{trademark} MS and SR image plates was conducted using a tungsten anode x-ray source and the resulting calibration applied to the design of the Ross pair spectrometer. Additionally, the fade rate and resolution of the image plate system were measured for quantitative radiographic applications. The conversion efficiency of laser energy into silver K{alpha} x rays from a petawatt laser target was measured using the differential filter pair spectrometer and compared to measurements using a single photon counting charge coupled device.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EGS Collab Experiment 2: Continuous Broadband Seismic Waveform Data

Two broadband seismometers were installed on the 4100 level and recorded for the duration of EGS Collab Experiment #2. Inspired by published data from similar instruments installed in the Aspo Hard Rock Lab, these long-period instruments aimed to measure the tilting of the drift in response to the injection of fluid into the testbed. One instrument was installed underneath the wellheads in Site A (aka the "battery" alcove) and the other was installed along the east wall of the drift, south of Site B. Due to the feet of gravel (ballast) laid along the floor of the drift, we were unable to anchor the sensors directly to the rock. As a result, the coupling of the sensors to the experiment rock volume is likely poor. In addition, there are a number of noise sources that complicate the interpretation of the data. For example, sensor BBB is installed adjacent (within 3 ft) to the rail line that runs towards the Ross shaft. Trains (motors) run along this line almost daily and produce a large signal in these data. Careful extraction of periods of interest, as well as filtering for specific signals, is necessary. The sensors are Nanometrics Trillium Compact Posthole seismometers, sensitive down to 120 seconds period. They were installed as close to the drift wall and as deep as we could manually excavate (only about 1 ft or so). The holes were leveled with sand and the sensors were placed on a paver before backfilling with sand. The hole was then covered by a bucket filled with insulation to improve the sensor's isolation from daily temperature variations, which are minor but present due to drift ventilation from the surface. Data were recorded on Nanometrics Centaur digitizers at 100 Hz. The full response information is available in the StationXML file provided here, or by querying the sensors through the IRIS DMC (see links below). These instruments were provided free of charge through the IRIS PASSCAL instrument center. The network code is XP and the station codes are BBA and BBB. The waveform data can be queried through the IRIS FDSN server using any method the user likes. One convenient option is to use the Obspy python package: https://docs.obspy.org/packages/obspy.clients.fdsn.html

15 GEOTHERMAL ENERGY↗

SETI OBSERVATIONS OF EXOPLANETS WITH THE ALLEN TELESCOPE ARRAY

We report radio SETI observations on a large number of known exoplanets and other nearby star systems using the Allen Telescope Array (ATA). Observations were made over about 19000 hr from 2009 May to 2015 December. This search focused on narrowband radio signals from a set totaling 9293 stars, including 2015 exoplanet stars and Kepler objects of interest and an additional 65 whose planets may be close to their habitable zones. The ATA observations were made using multiple synthesized beams and an anticoincidence filter to help identify terrestrial radio interference. Stars were observed over frequencies from 1 to 9 GHz in multiple bands that avoid strong terrestrial communication frequencies. Data were processed in near-real time for narrowband (0.7–100 Hz) continuous and pulsed signals with transmitter/receiver relative accelerations from −0.3 to 0.3 m s{sup −2}. A total of 1.9 × 10{sup 8} unique signals requiring immediate follow-up were detected in observations covering more than 8 × 10{sup 6} star-MHz. We detected no persistent signals from extraterrestrial technology exceeding our frequency-dependent sensitivity threshold of 180–310 × 10{sup −26} W m{sup −2}.

79 ASTRONOMY AND ASTROPHYSICS↗

Intitialization, Conceptualization, and Application in the Generalized Fractional Calculus

This paper provides a formalized basis for initialization in the fractional calculus. The intent is to make the fractional calculus readily accessible to engineering and the sciences. A modified set of definitions for the fractional calculus is provided which formally include the effects of initialization. Conceptualizations of fractional derivatives and integrals are shown. Physical examples of the basic elements from electronics are presented along with examples from dynamics, material science, viscoelasticity, filtering, instrumentation, and electrochemistry to indicate the broad application of the theory and to demonstrate the use of the mathematics. The fundamental criteria for a generalized calculus established by Ross (1974) are shown to hold for the generalized fractional calculus under appropriate conditions. A new generalized form for the Laplace transform of the generalized differintegral is derived. The concept of a variable structure (order) differintegral is presented along with initial efforts toward meaningful definitions.

Lorenzo, Carl F.↗

The effect of flattening filter free delivery on endothelial dose enhancement with gold nanoparticles

Purpose: The aim of this study is to quantify and to compare the dose enhancement factor from gold nanoparticles (AuNP) to tumor endothelial cells for different concentrations of AuNP, and clinical MV beam configurations. Methods: Tumor endothelial cells are modeled as slabs measuring 10 Multiplication-Sign 10 Multiplication-Sign 2 {mu}m. A spherical AuNP is simulated on the surface of the endothelial cell, within the blood vessel. 6 MV photon beams with and without the flattening filter are investigated for different field sizes, depths in material and beam modulation. The incident photon energy spectra for each configuration is generated using EGSnrc. The dose enhancement in the tumor endothelial cell is found using an analytical calculation. The endothelial dose enhancement factor is defined to be the ratio of the dose deposited with and without AuNPs. Results: It is found that clinical beam parameters may be chosen to maximize the effect of gold nanoparticles during radiotherapy. This effect is further amplified {approx}20% by the removal of the flattening filter. Modulation of the clinical beam with the multileaf collimator tends to decrease the proportion of low energy photons, therefore providing less enhancement than the corresponding open field. Conclusions: The results of this work predict a dose enhancement to tumor blood vessel endothelial cells using conventional therapeutic (MV) x-rays and quantify the relative change in enhancement with treatment depth and field size.

60 APPLIED LIFE SCIENCES↗

Development of the GeoNEX Level 2G Products: Exploiting the Diurnal Variability of TOA Reflectance in Atmospheric Correction

This study develops a new atmospheric correction algorithm to generate the Level 2G products, in particular the gap-filled Surface Reflectance at 10-minute time steps, for the Geostationary-NASA Earth Exchange (GeoNEX) project. The algorithm is based on the MODIS MAIAC (Multi-Angle Implementation of Atmospheric Correction) framework but with significant modifications to exploit angular/temporal information from the diurnal variability of the GeoNEX L1G TOA (Top-of-Atmosphere) reflectance. The algorithm starts by evaluating the roughness/smoothness of the diurnal time series of the TOA reflectance. Because rapid changes in TOA reflectance are generally caused by passing clouds or shadows, rough segments of the time series are automatically filtered out while the smooth segments are further tested for brightness and temperature to identify clear-sky and snow-free observations. Next the algorithm runs the MAIAC RTM (Radiative Transfer Model) to retrieve the Ross-Thick-Li-Sparse (RTLS) BRDF model parameters and the daily-mean atmospheric optical depth (AOD) that allow the RTM to optimally simulate the observed diurnal variability of clear-sky TOA reflectance. Once the initial RTLS parameters are retrieved after the algorithm’s burn-in period, they are used as the prior information to predict the AOD level for the next days, while the subsequent clear-sky observations are used to make necessary adjustments to the RTLS parameters in an continuous fashion. This “prediction-analysis” cycle is then iterated to process the full time series of the L1G data, skipping only total-cloudy days or when surface snow is detected. We tested the algorithm over a list of selected AERONET sites. The retrieved results (the daily mean AOD and the RTLS parameters) reasonably agree with the ground-based measurements. Importantly, the results indicate that the diurnal cycles of surface reflectance are continuous functions of the illumination-view geometry. Thus we can use the retrieved RTLS model to accurately fill in data gaps on partial cloudy days. Also, our algorithm is totally independent from the traditional approaches based on the use of spectral band ratios between the shortwave infrared (e.g., 2.2µm) and the visible (e.g., 0.47µm and 0.64µm) bands. Our results thus demonstrate that the high-frequent diurnal geostationary observations contain unique information that helps us improve atmospheric correction of remote sensing data.

GeoNEX↗

A novel method to recover DD fusion proton CR-39 data corrupted by fast ablator ions at OMEGA and the National Ignition Facility

CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE UV LUMINOSITY FUNCTION OF STAR-FORMING GALAXIES VIA DROPOUT SELECTION AT REDSHIFTS z {approx} 7 AND 8 FROM THE 2012 ULTRA DEEP FIELD CAMPAIGN

We present a catalog of high-redshift star-forming galaxies selected to lie within the redshift range z {approx_equal} 7-8 using the Ultra Deep Field 2012 (UDF12), the deepest near-infrared (near-IR) exposures yet taken with the Hubble Space Telescope (HST). As a result of the increased near-IR exposure time compared to previous HST imaging in this field, we probe {approx}0.65 (0.25) mag fainter in absolute UV magnitude, at z {approx} 7 (8), which increases confidence in a measurement of the faint end slope of the galaxy luminosity function. Through a 0.7 mag deeper limit in the key F105W filter that encompasses or lies just longward of the Lyman break, we also achieve a much-refined color-color selection that balances high redshift completeness and a low expected contamination fraction. We improve the number of dropout-selected UDF sources to 47 at z {approx} 7 and 27 at z {approx} 8. Incorporating brighter archival and ground-based samples, we measure the z {approx_equal} 7 UV luminosity function to an absolute magnitude limit of M{sub UV} = -17 and find a faint end Schechter slope of {alpha}=-1.87{sup +0.18}{sub -0.17}. Using a similar color-color selection at z {approx_equal} 8 that takes our newly added imaging in the F140W filter into account, and incorporating archival data from the HIPPIES and BoRG campaigns, we provide a robust estimate of the faint end slope at z {approx_equal} 8, {alpha}=-1.94{sup +0.21}{sub -0.24}. We briefly discuss our results in the context of earlier work and that derived using the same UDF12 data but with an independent photometric redshift technique.

79 ASTRONOMY AND ASTROPHYSICS↗

British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry

Purpose: The British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry was produced to provide an audit of current United Kingdom (UK) practice regarding placement and retrieval of IVC filters to address concerns regarding their safety. Methods: The IVC filter registry is a web-based registry, launched by the BSIR on behalf of its membership in October 2007. This report is based on prospectively collected data from October 2007 to March 2011. This report contains analysis of data on 1,434 IVC filter placements and 400 attempted retrievals performed at 68 UK centers. Data collected included patient demographics, insertion and retrieval data, and patient follow-up. Results: IVC filter use in the majority of patients in the UK follows accepted CIRSE guidelines. Filter placement is usually a low-risk procedure, with a low major complication rate (<0.5 %). Cook Gunther Tulip (560 filters: 39 %) and Celect (359 filters: 25 %) filters constituted the majority of IVC filters inserted, with Bard G2, Recovery filters, Cordis Trapease, and OptEase constituting most of the remainder (445 filters: 31 %). More than 96 % of IVC filters deployed as intended. Operator inexperience (<25 procedure) was significantly associated with complications (p < 0.001). Of the IVC filters initially intended for temporary placement, retrieval was attempted in 78 %. Of these retrieval was technically successful in 83 %. Successful retrieval was significantly reduced for implants left in situ for >9 weeks versus those with a shorter dwell time. New lower limb deep vein thrombosis (DVT) and/or IVC thrombosis was reported in 88 patients following filter placement, there was no significant difference of incidence between filter types. Conclusions: This registry report provides interventional radiologists and clinicians with an improved understanding of the technical aspects of IVC filter placement to help improve practice, and the potential consequences of IVC filter placement so that we are better able to advise patients. There is a significant learning curve associated with IVC filter insertion, and when a filter is placed with the intention of removal, procedures should be in place to avoid the patient being lost to follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray analysis methods for sources from self-modulated laser wakefield acceleration driven by picosecond lasers

A versatile set of methods for analyzing x-ray energy spectra and photon flux has been developed for laser plasma accelerator experiments driven by picosecond lasers. Forward fit provides extrapolated broad energy spectrum measurements, while Ross pair and differential average transmission analysis provide directly measured data points using a particular diagnostic. Combining these methods allows the measurement of x-ray energy spectra with improved confidence. We apply here the methods to three diagnostics (filter wheel, stacked image plate spectrometer, and step wedge), each sensitive to a different region of x-ray energies (<40 keV, 35–100 keV, and 60–1000 keV, respectively), to characterize the analysis methods using laser-driven bremsstrahlung x-rays. We then apply the methods to measure three x-ray mechanisms, betatron, inverse Compton scattering, and bremsstrahlung, driven by a laser plasma accelerator. The analysis results in the measurement of x-ray energy spectra ranging from 10 keV to 1 MeV with peak flux greater than 10 10 photons/keV/Sr. The combined analysis methods provide a robust tool to accurately measure broadband x-ray sources (keV to MeV) driven by laser plasma acceleration with picosecond, kilojoule-class lasers.

47 OTHER INSTRUMENTATION↗

Compartment modeling of dynamic brain PET—The impact of scatter corrections on parameter errors

Purpose: The aim of this study was to investigate the effect of scatter and its correction on kinetic parameters in dynamic brain positron emission tomography (PET) tumor imaging. The 2-tissue compartment model was used, and two different reconstruction methods and two scatter correction (SC) schemes were investigated. Methods: The GATE Monte Carlo (MC) software was used to perform 2 × 15 full PET scan simulations of a voxelized head phantom with inserted tumor regions. The two sets of kinetic parameters of all tissues were chosen to represent the 2-tissue compartment model for the tracer 3′-deoxy-3′-({sup 18}F)fluorothymidine (FLT), and were denoted FLT{sub 1} and FLT{sub 2}. PET data were reconstructed with both 3D filtered back-projection with reprojection (3DRP) and 3D ordered-subset expectation maximization (OSEM). Images including true coincidences with attenuation correction (AC) and true+scattered coincidences with AC and with and without one of two applied SC schemes were reconstructed. Kinetic parameters were estimated by weighted nonlinear least squares fitting of image derived time–activity curves. Calculated parameters were compared to the true input to the MC simulations. Results: The relative parameter biases for scatter-eliminated data were 15%, 16%, 4%, 30%, 9%, and 7% (FLT{sub 1}) and 13%, 6%, 1%, 46%, 12%, and 8% (FLT{sub 2}) for K{sub 1}, k{sub 2}, k{sub 3}, k{sub 4}, V{sub a}, and K{sub i}, respectively. As expected, SC was essential for most parameters since omitting it increased biases by 10 percentage points on average. SC was not found necessary for the estimation of K{sub i} and k{sub 3}, however. There was no significant difference in parameter biases between the two investigated SC schemes or from parameter biases from scatter-eliminated PET data. Furthermore, neither 3DRP nor OSEM yielded the smallest parameter biases consistently although there was a slight favor for 3DRP which produced less biased k{sub 3} and K{sub i} estimates while OSEM resulted in a less biased V{sub a}. The uncertainty in OSEM parameters was about 26% (FLT{sub 1}) and 12% (FLT{sub 2}) larger than for 3DRP although identical postfilters were applied. Conclusions: SC was important for good parameter estimations. Both investigated SC schemes performed equally well on average and properly corrected for the scattered radiation, without introducing further bias. Furthermore, 3DRP was slightly favorable over OSEM in terms of kinetic parameter biases and SDs.

60 APPLIED LIFE SCIENCES↗

Micromachined Tunable Fabry-Perot Filters for Infrared Astronomy

Micromachined Fabry-Perot tunable filters with a large clear aperture (12.5 to 40 mm) are being developed as an optical component for wide-field imaging 1:1 spectroscopy. This program applies silicon micromachining fabrication techniques to miniaturize Fabry-Perot filters for astronomical science instruments. The filter assembly consists of a stationary etalon plate mated to a plate in which the etalon is free to move along the optical axis on silicon springs attached to a stiff silicon support ring. The moving etalon is actuated electrostatically by electrode pairs on the fixed and moving etalons. To reduce mass, both etalons are fabricated by applying optical coatings to a thin freestanding silicon nitride film held flat in drumhead tension rather than to a thick optical substrate. The design, electro-mechanical modeling, fabrication, and initial results will be discussed. The potential application of the miniature Fabry-Perot filters will be briefly discussed with emphasis on the detection of extra-solar planets.

Barclay, Richard↗

Chain of Custody Item Monitor Message Viewer v.1.0 Beta

The CoCIM Message Viewer software allows users to connect to and download messages from a Chain of Custody Item Monitor (CoCIM) connected to a serial port on the user’s computer. The downloaded messages are authenticated and displayed in a Graphical User Interface that allows the user a limited degree of sorting and filtering of the downloaded messages as well as the ability to save downloaded files or to open previously downloaded message history files.

Schwartz, Steven Robert↗