Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Rogowski coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

23 records · Page 2

Explosion dynamics of thin flat foils at high current density

This paper presents characteristic features of the explosion of thin flat foils for currents and pulse risetimes ranging from 8 kA at 350 ns to 1000 kA at ~100 ns. Foils made of aluminum, copper, nickel, and titanium with thicknesses of 1–100 µm are tested. Various diagnostics in the optical, UV, and x-ray spectral ranges are used to image the exploding foils from initial breakdown to complete destruction or pinching. It is shown that foil explosion is a complex process that depends on many factors, but features common to all foils are found that do not depend on the parameters of the generators or, accordingly, on the energy deposited in the foil: for example, the breakdown of flat foils under different conditions occurs at the edges of the foil. For the first time, the formation of a precursor over the central part of the foil is shown, which significantly changes the dynamics of the foil explosion.

36 MATERIALS SCIENCE↗

Achieving stationary high performance plasmas at Wendelstein 7-X

This work reports on recent results on the search for high performance plasma scenarios at the magnetically confined stellarator fusion device Wendelstein 7-X. In four new designed scenarios, the development from transient toward stationary plasmas of improved performance has been realized. In particular, a high performance duration of up to 5 s, an energy confinement time of 0.3 s, a diamagnetic energy of 1.1 MJ, a central ion temperature of 2.2 keV, and a fusion triple product of 3.4 x 10 19 m -3 ∙ keV ∙ s have been achieved, and previously observed limitations of the machine have been overcome, regarding both the performance and its duration. The two main experimental techniques for stationary high performance are neutral beam injection core fueling on the one hand and the use of a magnetic field configuration with internal islands on the other hand. Two of the developed scenarios are expected to be extendable straightforward toward a duration of several tens of seconds, making use of the long pulse operation capabilities of W7-X.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanosecond Breakdown Characteristics of C 4 F 7 N and Various Mixtures at Pressures Above 1 Atmosphere in Comparison with SF 6

This report evaluates the pulsed breakdown performance of C 4 F 7 N under a 6.8 kV/ns voltage excitation. The pulsed dielectric strength of C 4 F 7 N is compared to SF 6 in the same experimental setup, and it is found that C 4 F 7 N concentrations of 50% or greater are required to achieve a dielectric strength greater than or equal to SF 6 . Pure C 4 F 7 N demonstrated higher electric field hold-off for longer time periods and less statistical variance under pulsed conditions when compared to SF 6 . Mixtures of 50%C 4 F 7 N with N 2 or CO 2 as buffer gases showed no appreciable difference in pulsed dielectric strength.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characteristics of Winter Lightning Currents Struck an Isolated Tower

To make clear the characteristics of winter lightning flashes, the current waveforms of winter lightning flashes were measured by two resistive shunts which were connected to two lighting rods since the winter of 1981, and another measurement has started using a set of five Rogowsky type coils since the winter of 1982. They were recorded by computer controlled digital recording systems. Up to date, 145 current waveforms of the winter lightning flashes, which have the current amplitude over 1 kA, were obtained by the shunt systems and/or the coils system. They show that winter lightning flashes often have a very long duration or continuing current and sometimes have a very large amplitude over 200 kA in positive flashes. For example, the current parameters that were measured on 9 Jan. 1987 were the maximum current amplitude, +280 kA, maximum current derivative 1.0 x 10(exp 10) A/s, total charge +400 C, and action integral 1.5 x 10(exp 7)(sq. A)(s). The statistical evaluation shows that medium peak values of winter lightning flashes (50 percent values) were about 5 kA for negative and 10 kA for positive, and 5 percent values were about 30 kA for negative and 170 kA for positive. The winter lightning current waveforms are classified into three types: single stroke flashes, monopolar multistroke flashes, and bipolar flashes. Moreover, each flash is subdivided into positive or negative, single peak or multipeak, and with or without continuing current.

Yukihiro Goto↗