Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Rh”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Accuracy Assessment and Correction of Vaisala RS92 Radiosonde Water Vapor Measurements

Relative humidity (RH) measurements from Vaisala RS92 radiosondes are widely used in both research and operational applications, although the measurement accuracy is not well characterized as a function of its known dependences on height, RH, and time of day (or solar altitude angle). This study characterizes RS92 mean bias error as a function of its dependences by comparing simultaneous measurements from RS92 radiosondes and from three reference instruments of known accuracy. The cryogenic frostpoint hygrometer (CFH) gives the RS92 accuracy above the 700 mb level; the ARM microwave radiometer gives the RS92 accuracy in the lower troposphere; and the ARM SurTHref system gives the RS92 accuracy at the surface using 6 RH probes with NIST-traceable calibrations. These RS92 assessments are combined using the principle of Consensus Referencing to yield a detailed estimate of RS92 accuracy from the surface to the lowermost stratosphere. An empirical bias correction is derived to remove the mean bias error, yielding corrected RS92 measurements whose mean accuracy is estimated to be +/-3% of the measured RH value for nighttime soundings and +/-4% for daytime soundings, plus an RH offset uncertainty of +/-0.5%RH that is significant for dry conditions. The accuracy of individual RS92 soundings is further characterized by the 1-sigma "production variability," estimated to be +/-1.5% of the measured RH value. The daytime bias correction should not be applied to cloudy daytime soundings, because clouds affect the solar radiation error in a complicated and uncharacterized way.

Whiteman, David N.↗

Beyond 3 Au from the Sun: the Hypervolatiles CH4, C2H6, and CO in the Distant Comet C2006 W3 (Christensen)

Comet C/2006 W3 (Christensen) remained outside a heliocentric distance (Rh) of 3.1 au throughout its apparition, but it presented an exceptional opportunity to directly sense a suite of molecules released from its nucleus. The Cryogenic Infrared Echelle Spectrograph at ESO-VLT detected infrared emissions from the three hypervolatiles (CO, CH4, and C2H6) that have the lowest sublimation temperatures among species that are commonly studied in comets by remote sensing. Even at Rh 3.25 au, the production rate of each molecule exceeded those measured for the same species in a number of other comets, although these comets were observed much closer to the Sun. Detections of CO at Rh = 3.25, 4.03, and 4.73 au constrained its post-perihelion decrease in production rate, which most likely dominated the outgassing. At 3.25 au, our measured abundances scaled as CO/CH4/C2H6 approx. = 100/4.4/2.1. The C2H6/CH4 ratio falls within the range of previously studied comets at Rh < 2 au, while CO/CH4 is comparatively high and similar to in situ measurements from Rosetta at approx.10 km from the nucleus of 67P/Churyumov-Gerasimenko conducted at a very similar Rh (3.15 au). The independent detections of H2O (Herschel Space Observatory) and CO (this work) imply a coma abundance H2O/CO approx. = 20% in C/2006 W3 near Rh = 5 au. All these measurements are of high value for constraining models of nucleus sublimation (plausibly CO-driven) beyond Rh = 3au, where molecular detections in comets are still especially sparse.

Bonev, Boncho P.↗

Dependence of Aerosol Light Absorption and Single-Scattering Albedo On Ambient Relative Humidity for Sulfate Aerosols with Black Carbon Cores

Atmospheric aerosols frequently contain hygroscopic sulfate species and black carbon (soot) inclusions. In this paper we report results of a modeling study to determine the change in aerosol absorption due to increases in ambient relative humidity (RH), for three common sulfate species, assuming that the soot mass fraction is present as a single concentric core within each particle. Because of the lack of detailed knowledge about various input parameters to models describing internally mixed aerosol particle optics, we focus on results that were aimed at determining the maximum effect that particle humidification may have on aerosol light absorption. In the wavelength range from 450 to 750 nm, maximum absorption humidification factors (ratio of wet to 'dry=30% RH' absorption) for single aerosol particles are found to be as large as 1.75 when the RH changes from 30 to 99.5%. Upon lesser humidification from 30 to 80% RH, absorption humidification for single particles is only as much as 1.2, even for the most favorable combination of initial ('dry') soot mass fraction and particle size. Integrated over monomodal lognormal particle size distributions, maximum absorption humidification factors range between 1.07 and 1.15 for humidification from 30 to 80% and between 1.1 and 1.35 for humidification from 30 to 95% RH for all species considered. The largest humidification factors at a wavelength of 450 nm are obtained for 'dry' particle size distributions that peak at a radius of 0.05 microns, while the absorption humidification factors at 700 nm are largest for 'dry' size distributions that are dominated by particles in the radius range of 0.06 to 0.08 microns. Single-scattering albedo estimates at ambient conditions are often based on absorption measurements at low RH (approx. 30%) and the assumption that aerosol absorption does not change upon humidification (i.e., absorption humidification equal to unity). Our modeling study suggests that this assumption alone can introduce absolute errors in estimates of the midvisible single-scattering albedo of up to 0.05 for realistic dry particle size distributions. Our study also indicates that this error increases with increasing wavelength. The potential errors in aerosol single-scattering albedo derived here are comparable in magnitude and in addition to uncertainties in single-scattering albedo estimates that are based on measurements of aerosol light absorption and scattering.

Redemann, Jens↗

Ecology and thermal inactivation of microbes in and on interplanetary space vehicle components

The heat resistance of Bacillus subtilis var. niger was measured from 85 to 125 C using moisture levels of % RH or = 0.001 to 100. Curves are presented which characterize thermal destruction using thermal death times defined as F values at a given combination of three moisture and temperature conditions. The times required at 100 C for reductions of 99.99% of the initial population were estimated for the three moisture conditions. The linear model (from which estimates of D are obtained) was satisfactory for estimating thermal death times (% RH or = 0.07) in the plate count range. Estimates based on observed thermal death times and D values for % RH = 100 diverged so that D values generally gave a more conservative estimate over the temperature range 90 to 125 C. Estimates of Z sub F and Z sub L ranged from 32.1 to 58.3 C for % RH of or = 0.07 and 100. A Z sub D = 30.0 was obtained for data observed at % RH or = 0.07.

Reyes, A. L.↗

Moisture interaction and stability of ZOT (Zinc Orthotitanate) thermal control spacecraft coating

Two of the many performance requirements of the zinc orthotitanate (ZOT) ceramic thermal control paint covering parts of the Jupiter-bound Galileo spacecraft are that it be sufficiently electrically conductive so as to prevent electrostatic discharge (ESD) damage to onboard electronics and that it adhere to and protect the substrate from corrosion in terrestrial environments. The bulk electrical resistivity of ZOT on an aluminum substrate was measured over the ranges 22 C to 90 C and 0 percent RH to 100 percent RH, and also in soft (10 (minus 2) Torr) and hard (10 (minus 7) Torr) vacuums. No significant temperature dependence was evident, but measured resistivity values ranged over 9 orders of magnitude: 10 to the 5th power ohm-cm at 100 percent RH greater than 10 to the 12th power ohm-cm in a hard vacuum. The latter value violates the ESD criterion for a typical 0.019 cm thick coating. The corrosion study involved exposing typical ZOT substrate combinations to two moisture environments - 30 C/85 percent RH and 85 C/85 percent RH - for 2000 hours, during which time the samples were periodically removed for front-to-back electrical resistance and scratch/peel test measurements. It was determined that the ZOT/Al and ZOT/Mg systems are stable (no ZOT delamination), although some corrosion (oxide formation) and resistivity increases observed among the ZOT/Mg samples warrant that exposure of some parts to humid environments be minimized.

Mon, Gordon R.↗

Radiation hardened microprocessor for small payloads

The RH-3000 program is developing a rad-hard space qualified 32-bit MIPS R-3000 RISC processor under the Naval Research Lab sponsorship. In addition, under IR&D Harris is developing RHC-3000 for embedded control applications where low cost and radiation tolerance are primary concerns. The development program leverages heavily from commercial development of the MIPS R-3000. The commercial R-3000 has a large installed user base and several foundry partners are currently producing a wide variety of R-3000 derivative products. One of the MIPS derivative products, the LR33000 from LSI Logic, was used as the basis for the design of the RH-3000 chipset. The RH-3000 chipset consists of three core chips and two support chips. The core chips include the CPU, which is the R-3000 integer unit and the FPA/MD chip pair, which performs the R-3010 floating point functions. The two support whips contain all the support functions required for fault tolerance support, real-time support, memory management, timers, and other functions. The Harris development effort had first passed silicon success in June, 1992 with the first rad-hard 32-bit RH-3000 CPU chip. The CPU device is 30 kgates, has a 508 mil by 503 mil die size and is fabricated at Harris Semiconductor on the rad-hard CMOS Silicon on Sapphire (SOS) process. The CPU device successfully passed tesing against 600,000 test vectors derived directly on the LSI/MIPS test suite and has been operational as a single board computer running C code for the past year. In addition, the RH-3000 program has developed the methodology for converting commercially developed designs utilizing logic synthesis techniques based on a combination of VHDK and schematic data bases.

Shah, Ravi↗

Influence of Humidity on the Aerosol Scattering Coefficient and Its Effect on the Upwelling Radiance During ACE-2

Aerosol scattering coefficients (sigma(sub sp)) have been measured over the ocean at different relative humidities (RH) as a function of attitude in the region surrounding the Canary Islands during the Second Aerosol Characterization Experiment (ACE-2) in June and July 1997. The data were collected by the University of Washington passive humidigraph (UWPH) mounted on the Pelican research aircraft. Concurrently, particle size distributions absorption coefficients and aerosol optical depth were measured throughout 17 flights. A parameterization of sigma(sub sp) as a function of RH was utilized to assess the impact of aerosol hydration on the upwelling radiance (normalized to the solar constant and cosine of zenith angle). The top of the atmosphere radiance signal was simulated at wavelengths corresponding to visible and near-infrared bands or the EOS-AM ("Terra") detectors, MODIS and MISR. The UWPH measured (sigma(sub sp)) at 2 RHs, one below and the other above ambient conditions. Ambient (sigma(sub sp)) was obtained by interpolation of these 2 measurements. The data were stratified in terms of 3 types of aerosols: Saharan dust, clean marine (marine boundary layer background) and polluted marine aerosols (i.e., 2- or 1-day old polluted aerosols advected from Europe). An empirical relation for the dependence of (sigma(sub sp)) on RH, defined by (sigma(sub sp))(RH) = k. ((1 - RH/100)(exp -gamma), was used with the hygroscopic exponent gamma derived from the data. The following gamma values were obtained for the 3 aerosol types: gamma(dust) = 0.23 +/- 0.05, gamma(clean marine) = 0.69 +/- 0.06 and gamma(polluted marine) = 0.57 + 0.06. Based on the measured (gamma)(s), the above equation was utilized to derive aerosol models with different hygroscopicities. The satellite simulation signal code 6S was used to compute the upwelling radiance corresponding to each of those aerosol models at several ambient humidities. For the pre-launch estimated precision of the sensors and the assumed viewing geometry of the instrument, the simulations suggest that the spectral and angular dependence of the reflectance measured by MISR is not sufficient to distinguish aerosol models with various different combinations of values ror dry composition. y and ambient RH. A similar behavior is observed for MODIS at visible wavelengths. However, the 2100 nm band of MODIS appears to be able to differentiate between at least some aerosol models with different aerosol hygroscopicity given the MODIS calibration error requirements. This result suggests the possibility of retrieval of aerosol hygroscopicity by MODIS.

Gasso, B. S.↗

Effects of Humidity On the Flow Characteristics of PS304 Plasma Spray Feedstock Powder Blend

The effects of environmental humidity on the flow characteristics of PS304 feedstock have been investigated. Angular and spherical BaF2-CaF2 powder was fabricated by comminution and by atomization, respectively. The fluorides were added incrementally to the nichrome, chromia, and silver powders to produce PS304 feedstock. The powders were dried in a vacuum oven and cooled to a Tom temperature under dry nitrogen. The flow of the powder was studied from 2 to 100 percent relative humidity (RH) The results suggest that the feedstock flow is slightly degraded with increasing humidity below 66 percent RH and is more affected above 66 percent RH. There was no flow above 88 percent RH. Narrower particle size distributions of the angular fluorides allowed flow up to 95 percent RH. These results offer guidance that enhances the commercial potential for this material system.

Stanford, Malcolm K.↗

Influence of Humidity On the Aerosol Scattering Coefficient and Its Effect on the Upwelling Radiance During ACE-2

Aerosol scattering coefficients (sigma(sub sp)) have been measured over the ocean at different relative humidities (RH) as a function of altitude in the region surrounding the Canary Islands during the Second Aerosol Characterization Experiment (ACE-2) in June and July 1997. The data were collected by the University of Washington passive humidigraph (UWPH) mounted on the Pelican research aircraft. Concurrently, particle size distributions, absorption coefficients and aerosol optical depth were measured throughout 17 flights. A parameterization of sigma(sub sp) as a function of RH was utilized to assess the impact of aerosol hydration on the upwelling radiance (normalized to the solar constant and cosine of zenith angle). The top of the atmosphere radiance signal was simulated at wavelengths corresponding to visible and near-infrared bands of the EOS (Earth Observing System) AM-1 (Terra) detectors, MODIS (Moderate Resolution Imaging Spectroradiometer) and MISR (Multi-angle Imaging Spectroradiometer). The UWPH measured sigma(sub sp) at two RHs, one below and the other above ambient conditions. Ambient sigma(sub sp) was obtained by interpolation of these two measurements. The data were stratified in terms of three types of aerosols: Saharan dust, clean marine (marine boundary layer background) and polluted marine aerosols (i.e., two- or one-day old polluted aerosols advected from Europe). An empirical relation for the dependence of sigma(sub sp) on RH, defined by sigma(sub sp)(RH) = k.(1 - RH/100)(sup gamma), was used with the hygroscopic exponent gamma derived from the data. The following gamma values were obtained for the 3 aerosol types: gamma(dust) = 0.23 +/- 0.05, gamma(clean marine) = 0.69 +/- 0.06 and gamma(polluted marine) = 0.57 +/- 0.06. Based on the measured gammas, the above equation was utilized to derive aerosol models with different hygroscopicities. The satellite simulation signal code 6S was used to compute the upwelling radiance corresponding to each of those aerosol models at several ambient humidities. For the prelaunch estimated precision of the sensors and the assumed viewing geometry of the instrument, the simulations suggest that the spectral and angular dependence of the reflectance measured by MISR is not sufficient to distinguish aerosol models with various different combinations of values for dry composition, gamma and ambient RH. A similar behavior is observed for MODIS at visible wavelengths. However, the 2100 nm band of MODIS appears to be able to differentiate between at least same aerosol models with different aerosol hygroscopicity given the MODIS calibration error requirements. This result suggests the possibility of retrieval of aerosol hygroscopicity by MODIS.

Gasso, S.↗

High relative humidity increases yield, harvest index, flowering, and gynophore growth of hydroponically grown peanut plants

Growth chamber experiments were conducted to study the physiological and growth response of peanut (Arachis hypogaea L.) to 50% and 85% relative humidity (RH). The objective was to determine the effects of RH on pod and seed yield, harvest index, and flowering of peanut grown by the nutrient film technique (NFT). 'Georgia Red' peanut plants (14 days old) were planted into growth channels (0.15 x 0.15 x 1.2 m). Plants were spaced 25 cm apart with 15 cm between channels. A modified half-Hoagland solution with an additional 2 mM Ca was used. Solution pH was maintained between 6.4 and 6.7, and electrical conductivity (EC) ranged between 1100 and 1200 microS cm-1. Temperature regimes of 28/22 degrees C were maintained during the light/dark periods (12 hours each) with photosynthetic photon flux (PPF) at canopy level of 500 micromoles-m-2s-1. Foliage and pod fresh and dry weights, total seed yield, harvest index (HI), and seed maturity were greater at high than at low RH. Plants grown at 85% RH had greater total and individual leaflet area and stomatal conductance, flowered 3 days earlier and had a greater number of flowers reaching anthesis. Gynophores grew more rapidly at 85% than at 50% RH.

NASA Discipline Life Support Systems↗

Effects of Humidity on Aerosols in Southern Africa during the Biomass Burning Season

Measurements of the aerosol total light scattering coefficient, asp, and the aerosol hemispheric backscatter ratio, p(1), as functions of relative humidity (RH in %) (so-called humidographs) at three wavelengths (450,550, and 700 nm) were obtained in the dry season in southern Africa (1) in ambient air in South Africa, Botswana, Mozambique and Zambia, (2) at various distances downwind in identifiable smoke plumes from biomass fires, and (3) along the southwest coast of Africa. The ratio of sigma(sub sp) at an RH of 80% to that at 30% provides a measure of the effects of RH on sigma(sub sp), and similarly for Beta(1). For the three broad sampling categories given above, and at a wavelength of 550 nm, these ratios varied from 1.42 +/- 0.05 to 2.07 +/- 0.03 for sigma(sub sp), and from 0.69 +/- 0.05 to 0.99 +/- 0.14 for Beta(1). In general, humidographs for the ambient air samples showed a greater dependence on RH than those for smoke from identifiable biomass fires. During a period when dense, aged smoke was transported to the region from the north, the humidographs for sigma(sub sp) for ambient air samples were similar to those for identifiable smoke plume samples just approximately 10- to 50-min old. This suggests that as far as the effects of RH on sigma(sub sp) are concerned the effects of aging of smoke and its mixing with ambient air are realized within less than about an hour.

Magi, Brian I.↗

En Route to Destruction: the Evolution in Composition of Ices in Comet D 2012 S1 (ISON) Between 1.2 and 0.34 Au from the Sun as Revealed at Infrared Wavelengths

We report production rates for H2O and eight trace molecules (CO, C2H6, CH4, CH3OH, NH3, H2CO, HCN, C2H2) in the dynamically new, Sun-grazing Comet C2012 S1 (ISON), using high-resolution spectroscopy at Keck II and the NASA IRTF on 10pre-perihelion dates encompassing heliocentric distances Rh1.210.34 AU. Measured water production rates spanned two orders of magnitude, consistent with a long-term heliocentric power law Q(H2O) Rh-3.10.1). Abundance ratios for CO, C2H6, and CH4 with respect to H2O remained constant with Rh and below their corresponding mean values measured among a dominant sample of Oort Cloud comets. CH3OH was also depleted for Rh 0.5 AU, but was closer to its mean value for Rh0.5 AU. The remaining four molecules exhibited higher abundance ratios within 0.5 AU: for Rh 0.8 AU, NH3 and C2H2 were consistent with their mean values while H2CO and HCN were depleted. For Rh 0.5 AU, all four were enriched, with NH3, H2CO, and HCN increasing most. Spatial profiles of gas emission in ISON consistently peaked sunward of the dust continuum, which was asymmetric antisunward and remained singly peaked for all observations. NH3 within 0.5 AU showed a broad spatial distribution, possibly indicating its release in the coma provided that optical depth effects were unimportant. The column abundance ratio NH2H2O at 0.83 AU was close to the typical NHOH from optical wavelengths, but was higher within 0.5 AU. Establishing its production rate and testing its parentage (e.g., NH3) require modeling of coma outflow.

Disanti, M. A.↗

Influence of Cloud, Fog, and High Relative Humidity during Pollution Transport Events in South Korea: Aerosol Properties and PM2.5 Variability

This investigation examines aerosol dynamics during major fine mode aerosol transboundary pollution events in South Korea primarily during the KORUS-AQ campaign from May 1 – June 10, 2016, particularly when cloud fraction was high and/or fog was present to quantify the change in aerosol characteristics due to near-cloud or fog interaction. We analyze the new AERONET Version 3 data that have significant changes to cloud screening algorithms, allowing many more fine-mode observations in the near vicinity of clouds or fog. Case studies for detailed investigation include May 25–26, 2016 when cloud fraction was high over much of the peninsula, associated with a weak frontal passage and advection of pollution from China. These cloud-influenced Chinese transport dates also had the highest aerosol optical depth (AOD), surface PM2.5 concentrations and fine mode particle sizes of the entire campaign. Another likewise cloud/high relative humidity (RH) case is June 9 and 10, 2016 when fog was present over the Yellow Sea that appears to have affected aerosol properties well downwind over the Korean peninsula. In comparison we also investigated aerosol properties on air stagnation days with very low cloud cover and relatively low RH (May 17 & 18, 2016), when local Korean emissions dominated. Aerosol volume size distributions show marked differences between the transport days (with high RH and cloud influences) and the local pollution stagnation days, with total column-integrated particle fine mode volume being an order of magnitude greater on the pollution transport dates. The PM2.5 over central Seoul were significantly greater than for coastal sites on the transboundary transport days yet not on stagnation days, suggesting addi-tional particle formation from gaseous urban emissions in cloud/fog droplets and/or in the high RH humidified aerosol environment. Many days had KORUS-AQ research aircraft flights that provided observations of aerosol absorption, particle chemistry and vertical profiles of extinction. AERONET retrievals and aircraft in situ mea-surements both showed high single scattering albedo (weak absorption) on the cloudy or cloud influenced days, plus aircraft profile in situ measurements showed large AOD enhancements (versus dried aerosol) at ambient relative humidity (RH) on the pollution transport days, consistent with the significantly larger fine mode particle radii and weak absorption.

Aerosol↗

Ecology and thermal inactivation of microbes in and on interplanetary space vehicle components

The thermal inactivation curve for Bacillus subtilis var. niger spores on the Viking lander is examined. Tests were conducted at 113 C and 25% RH, and over a wide range of temperatures using .001% RH and additions of P2O5 to dry the environment. Results show the 25% RH environment did not significantly reduce the survival curve, while the survival curves for spores treated under the drier .001% RH environment was reduced by a factor of 3.

Campbell, J. E.↗

Development of low cost, high reliability sealing techniques for hybrid microcircuit packages. Phase 2, supplement 1: Moisture permeation of adhesive-sealed hybrid microcircuit packages

The susceptibility of adhesive-sealed ceramic packages to moisture permeation was investigated. The two adhesives, Ablebond 789-1 and Epo-Tek H77, were evaluated as package sealants. These adhesives were previously selected as the most promising candidates for this application from a group of ten adhesives. Ceramic packages sealed with these adhesives were exposed to temperature-humidity conditions of 25 C/98 percent RH, 50 C/60 percent RH, 50 C/98 percent RH, and 85 C/85 percent RH and their moisture contents using were monitored solid state moisture sensors sealed inside them. Five packages were tested at each of these exposures - two ceramic packages sealed with each of the two adhesives and one seam-sealed gold-plated Kovar package. This latter package was included to serve as a control. The results showed that the adhesive-sealed packages were not hermetic to moisture. The rates at which moisture entered the packages increased with the severity of the exposure environments (i.e., higher temperatures and higher moisture vapor pressures) with greater dependence on temperature than on moisture vapor pressure.

Perkins, K. L.↗

Photochemistry of monodentate and bidentate carbonato complexes of rhodium (3)

A scheme for the photochemical fixation of water is proposed which involves a five-step reaction sequence; the first step involves the 2 electron reduction of a metal by a coordinated carbonate ligand, with corresponding oxidation of the carbonate to CO2 and O2. Ligand field photolysis of trans- (RH(en)2 H2O CO3) ClO4, and (Rh(en)2 CO3) CLO4 have been studied in the solid state and in aqueous solution at various pH values. Both salts are photoinert in the solid phase, but are quite photoreactive in aqueous solution. In solution, the monodentate ion undergoes efficient isomerization to a mixture of cis and trans - (Rh(en)2 H2O CO3)+, presumably with water exchange. A minor pH increase upon photolysis is evidence of inefficient carbonate (CO3 =) release, with formation of (Rh(en)2 (H2O)2)3+. In contrast, aqueous solutions of the bidentate carbonato complex undergo efficient pH decrease upon ligand field photolysis. Changes in the electronic spectrum (200-500 nm) and pH changes indicate that the desired redox is occurring. The pH increase is due to the aqueous behavior of CO2.

Sheridan, P. S.↗

Experimental determination of the effects of moisture on composite-to-composite adhesive joints

The primary mode of moisture ingress into bonded composite joints is determined using a nuclear probe for deuterium (NPD) to measure the localized D2O content along the length of the adhesive (FM-300 and EA-9601) and through the thickness of bonded composite speciments. Calculated diffusivities and NPD measured equilibrium moisture contents are used to predict the moisture profiles along the length of the adhesives as a function of exposure time, temperature, and relative humidity. These results are compared with the observed moisture profiles to evaluate the extent of enhanced edge diffusion. The FM-300 adhesive exhibits good agreement between measured and predicted profiles at 49 C, 70% and 90% RH, and 77 C, 70% RH. At 77 C, 90% RH, the measured moisture content near the adhesive edge is substantially larger than the predicted level. The EA-9601 adhesive also shows good agreement at 49 C, 70% and 90% RH, but at 77 C, the concentration of D20 near the edges is enhanced at each humidity level. The effect of moisture content on the bond shear strength at room temperature and at elevated temperature is evaluated.

Deiasi, R. J.↗

The complete polarization state of a storm of millisecond bursts from Jupiter

Normal bursts with right-hand (RH) elliptical polarization, millisec S-bursts with RH elliptical polarization, and S-bursts with left-hand (LH) elliptical polarization, are presently observed in an extended storm of decametric radiation from Jupiter's Io-related source, 'Io-B'. This radiation was 100 percent elliptically polarized at all frequencies in the 14-31 MHz range measured. For an 80-min period, there was a mixture of RH and LH elliptically polarized S bursts in the 14-20 MHz range. An examination of the origin of a Faraday-rotation difference between RH and LH elliptical bursts suggests that some Faraday rotation occurs in the Io torus; this was traversed more centrally by the LH bursts from the southern auroral zone than the HH bursts from the northern auroral zone.

Dulk, G. A.↗