Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relative accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Quality control and crop characterization framework for multi-temporal UAV LiDAR data over mechanized agricultural fields

Recent developments in remote sensing are enabling automatic, high resolution, and non-destructive survey of agriculture fields, providing the key basis for advancing plant breeding. Among the used remote sensing modalities, LiDAR has attracted wide attention for its ability to directly provide accurate 3D information. Despite the increasing utilization of LiDAR technology in phenotyping, there is still a lack of effective quality control strategies, in particular, quality control of LiDAR data collected on a multi-temporal basis. This study proposes a targetless framework for multi-temporal LiDAR data quality control and crop characterization in mechanized agricultural fields. Features extracted from the fields – terrain patches and row/alley locations – are utilized for evaluating the vertical and planimetric relative accuracy of the point clouds. Row/alley locations in the field are automatically identified from the point clouds based on the assumption that higher point density and/or higher elevation correspond to plant locations. The performance of the proposed quality control strategies is evaluated using multi-temporal datasets collected in agricultural fields of different sizes, orientation, crops, and growth stages. The result shows that the net vertical and planimetric discrepancies between multi-temporal point clouds are ±3 cm and ±8 cm, respectively. While the former reflects the actual accuracy of the point clouds, the latter is a combined effect of the LiDAR point cloud accuracy, rasterization artifacts, crop type, growth pattern, and wind condition during data acquisition. In terms of row and alley detection, the result shows that the proposed strategy achieves high performance and can deal with different planting orientation, crop types, growth stages, canopy cover, and planting density. In conclusion, this study presents a quality control framework for multi-temporal LiDAR data. Finally, the row and alley detection leads to automated extraction of plots, and hence facilitates the use of remotely sensed data for automated phenotyping.

54 ENVIRONMENTAL SCIENCES↗

Comparative Analysis of TCR and TCR-pMHC Complex Structure Prediction Tools

The rapid development of computational approaches for predicting the structures of T cell receptors (TCRs) and TCR-peptide-major histocompatibility (TCR-pMHC) complexes, accelerated by AI breakthroughs such as AlphaFold, has made it feasible to calculate these structures with increasing accuracy. Although these tools show great potential, their relative accuracy and limitations remain unclear due to the lack of standardized benchmarks. Here, we systematically evaluate seven tools for predicting isolated TCR structures together with six tools for predicting TCR-pMHC complex structures. The methods include homology-based approaches, general prediction tools using AlphaFold, TCR-specific tools derived from AlphaFold2, and the newly developed tFold-TCR model. The evaluation uses a post-training data set comprising 40 αβ TCRs and 27 TCR-pMHC complexes (21 Class I and 6 Class II). Model accuracy is assessed at global, local, and interface levels using a variety of metrics. We find that each tool offers distinct advantages in various aspects of its predictions. AlphaFold2, AlphaFold3, and tFold-TCR excel in overall accuracy of TCR structure prediction, and TCRmodel2 and AlphaFold2 perform well in overall accuracy of TCR-pMHC structure prediction. However, TCR-specific tools derived from AlphaFold2 show lower accuracy in the framework region than both homology-based methods and general-purpose tools such as AlphaFold, and challenges remain for all in modeling CDR3 loops, docking orientations, TCR-peptide interfaces, and Class II MHC-peptide interfaces. Furthermore, these findings will guide researchers in selecting appropriate tools, emphasize the importance of using multiple evaluation metrics to assess model performance, and offer suggestions for improving TCR and TCR-pMHC structure prediction tools.

Chemical structure↗

Predictive performance of multi-model ensemble forecasts of COVID-19 across European nations

Background: Short-term forecasts of infectious disease burden can contribute to situational awareness and aid capacity planning. Based on best practice in other fields and recent insights in infectious disease epidemiology, one can maximise the predictive performance of such forecasts if multiple models are combined into an ensemble. Here, we report on the performance of ensembles in predicting COVID-19 cases and deaths across Europe between 08 March 2021 and 07 March 2022. Methods: We used open-source tools to develop a public European COVID-19 Forecast Hub. We invited groups globally to contribute weekly forecasts for COVID-19 cases and deaths reported by a standardised source for 32 countries over the next 1–4 weeks. Teams submitted forecasts from March 2021 using standardised quantiles of the predictive distribution. Each week we created an ensemble forecast, where each predictive quantile was calculated as the equally-weighted average (initially the mean and then from 26th July the median) of all individual models’ predictive quantiles. We measured the performance of each model using the relative Weighted Interval Score (WIS), comparing models’ forecast accuracy relative to all other models. We retrospectively explored alternative methods for ensemble forecasts, including weighted averages based on models’ past predictive performance. Results: Over 52 weeks, we collected forecasts from 48 unique models. We evaluated 29 models’ forecast scores in comparison to the ensemble model. We found a weekly ensemble had a consistently strong performance across countries over time. Across all horizons and locations, the ensemble performed better on relative WIS than 83% of participating models’ forecasts of incident cases (with a total N=886 predictions from 23 unique models), and 91% of participating models’ forecasts of deaths (N=763 predictions from 20 models). Across a 1–4 week time horizon, ensemble performance declined with longer forecast periods when forecasting cases, but remained stable over 4 weeks for incident death forecasts. In every forecast across 32 countries, the ensemble outperformed most contributing models when forecasting either cases or deaths, frequently outperforming all of its individual component models. Among several choices of ensemble methods we found that the most influential and best choice was to use a median average of models instead of using the mean, regardless of methods of weighting component forecast models. Conclusions: Our results support the use of combining forecasts from individual models into an ensemble in order to improve predictive performance across epidemiological targets and populations during infectious disease epidemics. Our findings further suggest that median ensemble methods yield better predictive performance more than ones based on means. Our findings also highlight that forecast consumers should place more weight on incident death forecasts than incident case forecasts at forecast horizons greater than 2 weeks. Funding: AA, BH, BL, LWa, MMa, PP, SV funded by National Institutes of Health (NIH) Grant 1R01GM109718, NSF BIG DATA Grant IIS-1633028, NSF Grant No.: OAC-1916805, NSF Expeditions in Computing Grant CCF-1918656, CCF-1917819, NSF RAPID CNS-2028004, NSF RAPID OAC-2027541, US Centers for Disease Control and Prevention 75D30119C05935, a grant from Google, University of Virginia Strategic Investment Fund award number SIF160, Defense Threat Reduction Agency (DTRA) under Contract No. HDTRA1-19-D-0007, and respectively Virginia Dept of Health Grant VDH-21-501-0141, VDH-21-501-0143, VDH-21-501-0147, VDH-21-501-0145, VDH-21-501-0146, VDH-21-501-0142, VDH-21-501-0148. AF, AMa, GL funded by SMIGE - Modelli statistici inferenziali per governare l'epidemia, FISR 2020-Covid-19 I Fase, FISR2020IP-00156, Codice Progetto: PRJ-0695. AM, BK, FD, FR, JK, JN, JZ, KN, MG, MR, MS, RB funded by Ministry of Science and Higher Education of Poland with grant 28/WFSN/2021 to the University of Warsaw. BRe, CPe, JLAz funded by Ministerio de Sanidad/ISCIII. BT, PG funded by PERISCOPE European H2020 project, contract number 101016233. CP, DL, EA, MC, SA funded by European Commission - Directorate-General for Communications Networks, Content and Technology through the contract LC-01485746, and Ministerio de Ciencia, Innovacion y Universidades and FEDER, with the project PGC2018-095456-B-I00. DE., MGu funded by Spanish Ministry of Health / REACT-UE (FEDER). DO, GF, IMi, LC funded by Laboratory Directed Research and Development program of Los Alamos National Laboratory (LANL) under project number 20200700ER. DS, ELR, GG, NGR, NW, YW funded by National Institutes of General Medical Sciences (R35GM119582; the content is solely the responsibility of the authors and does not necessarily represent the official views of NIGMS or the National Institutes of Health). FB, FP funded by InPresa, Lombardy Region, Italy. HG, KS funded by European Centre for Disease Prevention and Control. IV funded by Agencia de Qualitat i Avaluacio Sanitaries de Catalunya (AQuAS) through contract 2021-021OE. JDe, SMo, VP funded by Netzwerk Universitatsmedizin (NUM) project egePan (01KX2021). JPB, SH, TH funded by Federal Ministry of Education and Research (BMBF; grant 05M18SIA). KH, MSc, YKh funded by Project SaxoCOV, funded by the German Free State of Saxony. Presentation of data, model results and simulations also funded by the NFDI4Health Task Force COVID-19 ( https://www.nfdi4health.de/task-force-covid-19-2 ) within the framework of a DFG-project (LO-342/17-1). LP, VE funded by Mathematical and Statistical modelling project (MUNI/A/1615/2020), Online platform for real-time monitoring, analysis and management of epidemic situations (MUNI/11/02202001/2020); VE also supported by RECETOX research infrastructure (Ministry of Education, Youth and Sports of the Czech Republic: LM2018121), the CETOCOEN EXCELLENCE (CZ.02.1.01/0.0/0.0/17-043/0009632), RECETOX RI project (CZ.02.1.01/0.0/0.0/16-013/0001761). NIB funded by Health Protection Research Unit (grant code NIHR200908). SAb, SF funded by Wellcome Trust (210758/Z/18/Z).

60 APPLIED LIFE SCIENCES↗

Application of Improved Radiation Modeling to General Circulation Models

This research has accomplished its primary objectives of developing accurate and efficient radiation codes, validating them with measurements and higher resolution models, and providing these advancements to the global modeling community to enhance the treatment of cloud and radiative processes in weather and climate prediction models. A critical component of this research has been the development of the longwave and shortwave broadband radiative transfer code for general circulation model (GCM) applications, RRTMG, which is based on the single-column reference code, RRTM, also developed at AER. RRTMG is a rigorously tested radiation model that retains a considerable level of accuracy relative to higher resolution models and measurements despite the performance enhancements that have made it possible to apply this radiation code successfully to global dynamical models. This model includes the radiative effects of all significant atmospheric gases, and it treats the absorption and scattering from liquid and ice clouds and aerosols. RRTMG also includes a statistical technique for representing small-scale cloud variability, such as cloud fraction and the vertical overlap of clouds, which has been shown to improve cloud radiative forcing in global models. This development approach has provided a direct link from observations to the enhanced radiative transfer provided by RRTMG for application to GCMs. Recent comparison of existing climate model radiation codes with high resolution models has documented the improved radiative forcing capability provided by RRTMG, especially at the surface, relative to other GCM radiation models. Due to its high accuracy, its connection to observations, and its computational efficiency, RRTMG has been implemented operationally in many national and international dynamical models to provide validated radiative transfer for improving weather forecasts and enhancing the prediction of global climate change.

54 ENVIRONMENTAL SCIENCES↗

Hierarchical-embedding autoencoder with a predictor as efficient architecture for learning time-evolution in multi-scale turbulent flows

We introduce a scale-aware, data-driven deep learning modeling framework for accurately predicting the time evolution of multi-scale turbulent plasma and liquid flows. The approach is motivated by the idea of scale separation. Structures of vastly different length scales emerge in these systems, and interactions between these structures occur only locally. To exploit this structure, the flow state is transformed by a hierarchical, fully convolutional autoencoder, not into a single embedding layer as in conventional convolutional surrogate models, but into a series of embedding layers. A stepwise training strategy ensures that fine-scale features are encoded on a high-resolution grid, while larger structures are represented on progressively coarser layers. The time evolution predictor advances all embedding layers in sync, capturing local interactions between features at the same scale as well as between all scales. This approach enables efficient modeling of multi-scale systems since negligible interactions between distant, small-scale structures do not need to be directly modeled. Our hierarchical-embedding autoencoder with a predictor framework is evaluated on canonical examples of multi-scale turbulence: two-dimensional Kolmogorov flow and Hasegawa–Wakatani plasma turbulence. In both cases, the proposed framework significantly improves predictive accuracy relative to conventional convolutional network architectures. A significant improvement in prediction accuracy was observed for crucial statistical characteristics of the Hasegawa–Wakatani plasma as well as for individual trajectories of the Kolmogorov flow turbulence. Importantly, the model's rollout for the Hasegawa–Wakatani problem demonstrates a four-order-of-magnitude speedup compared to traditional numerical solvers.

Khrabry, Alexander I. [Princeton Univ., NJ (United↗

Classifying Cancer Pathology Reports with Hierarchical Self-Attention Networks

We introduce a deep learning architecture, hierarchical self-attention networks (HiSANs), designed for classifying pathology reports and show how its unique architecture leads to a new state-of-the-art in accuracy, faster training, and clear interpretability. We evaluate performance on a corpus of 374,899 pathology reports obtained from the National Cancer Institute's (NCI) Surveillance, Epidemiology, and End Results (SEER) program. Each pathology report is associated with five clinical classification tasks – site, laterality, behavior, histology, and grade. We compare the performance of the HiSAN against other machine learning and deep learning approaches commonly used on medical text data – Naive Bayes, logistic regression, convolutional neural networks, and hierarchical attention networks (the previous state-of-the-art). We show that HiSANs are superior to other machine learning and deep learning text classifiers in both accuracy and macro F-score across all five classification tasks. Compared to the previous state-of-the-art, hierarchical attention networks, HiSANs not only are an order of magnitude faster to train, but also achieve about 1% better relative accuracy and 5% better relative macro F-score.

60 APPLIED LIFE SCIENCES↗

SU-E-T-438: Frameless Cranial Stereotactic Radiosurgery Immobilization Effectiveness Evaluation

Purpose: To evaluate immobilization effectiveness of Brainlab frameless mask in cranial stereotactic radiosurgery (SRS). Methods: Two sets of setup images were collected pre-and post-treatment for 24 frameless SRS cases. The pre-treatment images were obtained after applying 2D-2D kV image-guided shifts with patients in treatment position and approved by physicians; the post-treatment images were taken immediately after treatment completion. All cases were treated on a Novalis linac with ExacTrac positioning system and Exact Couch. The two image sets were compared with the correctional shifts measured by ExacTrac 6D auto-fusion. The shift differences were considered patient motion within the frameless mask and were used to evaluate its effectiveness for immobilization. Two-tailed paired t-test was applied for significance comparison. Results: The correctional shifts (mean±STD, median) of pre-and post-treatment images were 0.33±0.27mm, 0.26mm and 0.34±0.27mm, 0.23mm (p=0.740) in lateral direction; 0.32±0.29mm, 0.22mm and 0.48±0.30mm, 0.50mm (p=0.012) in longitudinal direction; 0.31±0.22mm, 0.24mm and 0.33±0.21mm, 0.36mm (p=0.623) in vertical direction. The radial correctional shifts (mean±STD, median) of pre -and post-treatment images were 0.60±0.38mm, 0.45mm and 0.75±0.31mm, 0.66mm (p=0.033). The shift differences (mean±STD, median, maximum) were 0.35±0.28mm, 0.3mm, 1.05mm, 0.34±0.28mm, 0.3mm, 1.00mm, 0.24±0.15mm, 0.21mm, 0.60mm and 0.61±0.32mm, 0.57mm, 1.40mm in lateral, longitudinal, vertical and radial direction, respectively. Two shifts greater than 1 mm (1.06mm and 1.02mm) were acquired from post-treatment images. However, the shift differences were only 0.09 and 0.19mm for these two shifts. Two patients with shift differences greater than 1mm (1.05 and 1.04mm) were observed and didn’t coincide with those two who had post-correctional shifts greater than 1mm. Conclusion: Image-guided SRS allowed us to set up patients with sub-millimeter accuracy relative to simulation position. However, patient motion during treatment could affect treatment accuracy. Our Result shows that Brainlab frameless mask provides reasonable patient immobilization and maintains the mean post-treatment position within sub-millimeter accuracy with some borderline results observed.

60 APPLIED LIFE SCIENCES↗

Machine learning enables reconstruction of past fire regimes from charcoal-derived fire intensity and fuel composition

Background Fire is a foundational ecological process that shapes ecosystem structure, diversity, and resilience. Quantifying paleofire regime attributes such as frequency, severity, and intensity is essential for understanding the historical range of variability in fire behavior and its ecological effects. While frequency and severity are often reconstructed in paleofire studies, quantitative reconstructions of fire intensity remain limited. Recent work has shown that maximum pyrolysis temperature—a proxy for fire intensity—and plant species type can be inferred from charcoal using transmission Fourier-transform infrared (FTIR) spectroscopy. However, the sample preparation for transmission FTIR is destructive and time-consuming, limiting application and reuse of materials for other analyses. We evaluated reflectance FTIR spectroscopy as a non-destructive alternative for reconstructing combustion temperature and plant species from laboratory-generated charcoal. We also examined the influence of contrasting airflow environments (ambient air versus nitrogen-rich) on pyrolysis temperature and plant species reconstruction prediction accuracies and compared predictive performance between a novel, neural network–based deep learning model with the traditional modern analogue technique (MAT) using k-nearest neighbor functions. As proof of concept, we apply our enhanced methodology to ancient charcoal to demonstrate applicability at improving long-term fire regime reconstructions and the ability to link paleofire records with contemporary fire ecology. Results Our analysis shows that transmission and reflectance FTIR spectra yield comparable spectral profiles. However, sample preparation for reflectance FTIR is minimal and non-destructive, unlike transmission FTIR which is destructive. We demonstrate that oxygen environments improved reconstruction accuracy relative to nitrogen-rich conditions. Finally, our deep learning neural network (DL) achieved testing accuracies of 98.7% for temperature and 96.2% for species identification, outperforming MAT’s k-NN approach (89.8% and 65.9%, respectively). A Shapley importance analysis identified 5 key spectral regions that greatly influenced the model’s temperature or species categorization. When applied to ancient charcoal, our results show historic fires from the most recent past primarily burned at low intensities (400–500 °C), reflective of natural fire regimes in ponderosa pine forests. Our results corroborate charcoal morphology data that suggests all ancient charcoal originated from burned woody plant types. Conclusions By combining reflectance FTIR spectroscopy with a deep learning approach, we provide the first accuracies high enough to confidently identify both species and temperature from laboratory-produced charcoal, improving quantitative reconstructions of fire intensity and fuel composition from paleofire records. This opens a wide range of research into the link between fire and larger drivers (i.e., climate or human) and greater ecological understanding of fire regimes beyond that of burn scars or recent observations. These methodological improvements have direct relevance for fire management by improving interpretation of historical fire behavior, informing fuel–fire relationships, and providing a scalable analytical framework applicable to both long-term ecological studies and contemporary fire science.

54 ENVIRONMENTAL SCIENCES↗

Uncertainty Analysis for Photovoltaic Degradation Rates (Poster)

Dependable and predictable energy production is the key to the long-term success of the PV industry. PV systems show over the lifetime of their exposure a gradual decline that depends on many different factors such as module technology, module type, mounting configuration, climate etc. When degradation rates are determined from continuous data the statistical uncertainty is easily calculated from the regression coefficients. However, total uncertainty that includes measurement uncertainty and instrumentation drift is far more difficult to determine. A Monte Carlo simulation approach was chosen to investigate a comprehensive uncertainty analysis. The most important effect for degradation rates is to avoid instrumentation that changes over time in the field. For instance, a drifting irradiance sensor, which can be achieved through regular calibration, can lead to a substantially erroneous degradation rates. However, the accuracy of the irradiance sensor has negligible impact on degradation rate uncertainty emphasizing that precision (relative accuracy) is more important than absolute accuracy.

14 SOLAR ENERGY↗

A stochastic sampling approach to zircon eruption age interpretation

The accessory mineral zircon is widely used to constrain the timing of igneous processes such as magma crystallisation or eruption. However, zircon U-Pb ages record zircon crystallisation, which is not an instantaneous process. Zircon saturation calculations link zircon crystallisation, temperature, and melt fraction, allowing for the estimation of zircon crystallisation distributions as a function of time or temperature. Such distributions provide valuable prior information, enabling Bayesian estimates of magma eruption time and allowing for comparison of the relative accuracy of common weighted-mean and youngest-zircon age interpretations with synthetic datasets. We find that both traditional interpretations carry a risk of underestimating the uncertainty in eruption age; a low mean square of weighted deviates (MSWD) does not guarantee the accuracy of weighted-mean interpretations. In the absence of independent confirmation that crystallisation timescale is short relative to analytical uncertainties, a Bayesian approach frequently provides the most accurate results and is least likely to underestimate uncertainty. Finally, since U-Pb zircon studies now routinely resolve geological age dispersion due to increasing analytical precision, such considerations are increasingly critical to future progress in resolving rates and dates of Earth processes.

58 GEOSCIENCES↗

Leading order nonadiabatic corrections to rovibrational levels of H{sub 2}, D{sub 2}, and T{sub 2}

An efficient computational approach to nonadiabatic effects in the hydrogen molecule (H{sub 2}, D{sub 2}, and T{sub 2}) is presented. The electronic wave function is expanded in the James-Coolidge basis set, which enables obtaining a very high accuracy of nonadiabatic potentials. A single point convergence of the potentials with growing size of the basis set reveals a relative accuracy ranging from 10{sup −8} to 10{sup −13}. An estimated accuracy of the leading nonadiabatic correction to the rovibrational energy levels is of the order of 10{sup −7} cm{sup −1}. After a significant increase in the accuracy of the Born-Oppenheimer and adiabatic calculations, the nonadiabatic results presented in this report constitute another step towards highly accurate theoretical description of the hydrogen molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deformable image registration of heterogeneous human lung incorporating the bronchial tree

Purpose: To investigate the effect of the bronchial tree on the accuracy of biomechanical-based deformable image registration of human lungs. Methods: Three dimensional finite element models have been developed using four dimensional computed tomography image data of ten lung cancer patients. Each model is built of a body, left and right lungs, tumor, and bronchial trees. Triangular shell elements are used for the bronchial trees while tetrahedral elements are used for other components. Hyperelastic material properties based on experimental investigation on human lungs are used for the lung parenchyma. Different material properties are assigned for the bronchial tree using five values for the modulus of elasticity of 0.01, 0.12, 0.5, 10, and 18 MPa. Lungs are modeled to slide inside chest cavities by applying frictionless contact surfaces between each lung and corresponding chest cavity. The accuracy of the models is examined using an average of 40 bronchial bifurcation points identified on inhale and exhale images. Relative accuracy is evaluated by comparing the displacement of all nodes within the lungs as well as the dosimetric difference at the exhale position predicted by the model. Results: There is no significant effect of bronchial tree on the model accuracy based on the bifurcation points analysis. However, on the local level, using an average of 38 000 nodes, there is a maximum difference of 8.5 mm in the deformation of the bronchial trees, as the modulus of elasticity of the bronchial trees increases from 0.01 to 18 MPa; however, more than 96% of nodes are within a 2.5 mm difference in each direction. The average dose difference at the predicted exhale position is less than 35 cGy between the models. Conclusions: The bronchial tree has little effect on the global deformation and the accuracy of deformable image registration of lungs. Hence, the homogenous model is a reasonable assumption. Since there are some local deformation differences between nodes as the material properties of the bronchial tree change that may affect the accuracy of dosimetric results, heterogeneity may be required for a smaller scale modeling of lungs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Volumetric Image Guidance Using Carina vs Spine as Registration Landmarks for Conventionally Fractionated Lung Radiotherapy

Purpose: To compare the relative accuracy of 2 image guided radiation therapy methods using carina vs spine as landmarks and then to identify which landmark is superior relative to tumor coverage. Methods and Materials: For 98 lung patients, 2596 daily image-guidance cone-beam computed tomography scans were analyzed. Tattoos were used for initial patient alignment; then, spine and carina registrations were performed independently. A separate analysis assessed the adequacy of gross tumor volume, internal target volume, and planning target volume coverage on cone-beam computed tomography using the initial, middle, and final fractions of radiation therapy. Coverage was recorded for primary tumor (T), nodes (N), and combined target (T+N). Three scenarios were compared: tattoos alignment, spine registration, and carina registration. Results: Spine and carina registrations identified setup errors {>=}5 mm in 35% and 46% of fractions, respectively. The mean vector difference between spine and carina matching had a magnitude of 3.3 mm. Spine and carina improved combined target coverage, compared with tattoos, in 50% and 34% (spine) to 54% and 46% (carina) of the first and final fractions, respectively. Carina matching showed greater combined target coverage in 17% and 23% of fractions for the first and final fractions, respectively; with spine matching, this was only observed in 4% (first) and 6% (final) of fractions. Carina matching provided superior nodes coverage at the end of radiation compared with spine matching (P=.0006), without compromising primary tumor coverage. Conclusion: Frequent patient setup errors occur in locally advanced lung cancer patients. Spine and carina registrations improved combined target coverage throughout the treatment course, but carina matching provided superior combined target coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination and correction of distortions and systematic errors in low-energy electron diffraction

We developed and implemented an algorithm to determine and correct systematic distortions in low-energy electron diffraction (LEED) images. The procedure is in principle independent of the design of the apparatus (spherical or planar phosphorescent screen vs. channeltron detector) and is therefore applicable to all device variants, known as conventional LEED, micro-channel plate LEED, and spot profile analysis LEED. The essential prerequisite is a calibration image of a sample with a well-known structure and a suitably high number of diffraction spots, e.g., a Si(111)-7×7 reconstructed surface. The algorithm provides a formalism which can be used to rectify all further measurements generated with the same device. In detail, one needs to distinguish between radial and asymmetric distortion. Additionally, it is necessary to know the primary energy of the electrons precisely to derive accurate lattice constants. Often, there will be a deviation between the true kinetic energy and the value set in the LEED control. Here, we introduce a method to determine this energy error more accurately than in previous studies. Following the correction of the systematic errors, a relative accuracy of better than 1% can be achieved for the determination of the lattice parameters of unknown samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of Spatial Uncertainties in the Radiotherapy Process With the Novalis System

Purpose: The purpose of this study was to evaluate the accuracy of a new version of the ExacTrac X-ray (ETX) system with statistical analysis retrospectively in order to determine the tolerance of systematic components of spatial uncertainties with the Novalis system. Methods and Materials: Three factors of geometrical accuracy related to the ETX system were evaluated by phantom studies. First, location dependency of the detection ability of the infrared system was evaluated. Second, accuracy of the automated calculation by the image fusion algorithm in the patient registration software was evaluated. Third, deviation of the coordinate scale between the ETX isocenter and the mechanical isocenter was evaluated. From the values of these examinations and clinical experiences, the total spatial uncertainty with the Novalis system was evaluated. Results: As to the location dependency of the detection ability of the infrared system, the detection errors between the actual position and the detected position were 1% in translation shift and 0.1{sup o} in rotational angle, respectively. As to the accuracy of patient verification software, the repeatability and the coincidence of the calculation value by image fusion were good when the contrast of the X-ray image was high. The deviation of coordinates between the ETX isocenter and the mechanical isocenter was 0.313 {+-} 0.024 mm, in a suitable procedure. Conclusions: The spatial uncertainty will be less than 2 mm when suitable treatment planning, optimal patient setup, and daily quality assurance for the Novalis system are achieved in the routine workload.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linear source approximation in CASMO5

A Linear Source (LS) approximation has been implemented in the two-dimensional Method of Characteristics (MOC) transport solver in a prototype version of CASMO5. The LS approximation, which relies on the computation of trajectory-based spatial moments over source regions to obtain the linear source expansion coefficients, improves the solution accuracy relative to the 'flat' or constant source approximation. In addition, the LS formulation is capable of treating arbitrarily-shaped source regions and is compatible with standard Coarse-Mesh Finite Difference (CMFD) acceleration. Numerical tests presented in this paper for the C5G7 MOX benchmark show that, for comparable accuracy with respect to the reference solution, the LS approximation can reduce the run time by a factor of four and the memory requirements by a factor often relative to the FS scheme. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Accurate spectroscopic characterization of oxirane: A valuable route to its identification in Titan's atmosphere and the assignment of unidentified infrared bands

In an effort to provide an accurate spectroscopic characterization of oxirane, state-of-the-art computational methods and approaches have been employed to determine highly accurate fundamental vibrational frequencies and rotational parameters. Available experimental data were used to assess the reliability of our computations, and an accuracy on average of 10 cm{sup –1} for fundamental transitions as well as overtones and combination bands has been pointed out. Moving to rotational spectroscopy, relative discrepancies of 0.1%, 2%-3%, and 3%-4% were observed for rotational, quartic, and sextic centrifugal-distortion constants, respectively. We are therefore confident that the highly accurate spectroscopic data provided herein can be useful for identification of oxirane in Titan's atmosphere and the assignment of unidentified infrared bands. Since oxirane was already observed in the interstellar medium and some astronomical objects are characterized by very high D/H ratios, we also considered the accurate determination of the spectroscopic parameters for the mono-deuterated species, oxirane-d1. For the latter, an empirical scaling procedure allowed us to improve our computed data and to provide predictions for rotational transitions with a relative accuracy of about 0.02% (i.e., an uncertainty of about 40 MHz for a transition lying at 200 GHz).

74 ATOMIC AND MOLECULAR PHYSICS↗

Accuracy considerations for Chebyshev rational approximation method (CRAM) in Burnup calculations

The burnup equations can in principle be solved by computing the exponential of the burnup matrix. However, due to the difficult numerical characteristics of burnup matrices, the problem is extremely stiff and the matrix exponential solution has previously been considered infeasible for an entire burnup system containing over a thousand nuclides. It was recently discovered by the author that the eigenvalues of burnup matrices are generally located near the negative real axis, which prompted introducing the Chebyshev rational approximation method (CRAM) for solving the burnup equations. CRAM can be characterized as the best rational approximation on the negative real axis and it has been shown to be capable of simultaneously solving an entire burnup system both accurately and efficiently. In this paper, the accuracy of CRAM is further studied in the context of burnup equations. The approximation error is analyzed based on the eigenvalue decomposition of the burnup matrix. It is deduced that the relative accuracy of CRAM may be compromised if a nuclide concentration diminishes significantly during the considered time step. Numerical results are presented for two test cases, the first one representing a small burnup system with 36 nuclides and the second one a full a decay system with 1531 nuclides. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗