Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relative accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Accuracy of surface registration compared to conventional volumetric registration in patient positioning for head-and-neck radiotherapy: A simulation study using patient data

Purpose: 3D optical surface imaging has been applied to patient positioning in radiation therapy (RT). The optical patient positioning system is advantageous over conventional method using cone-beam computed tomography (CBCT) in that it is radiation free, frameless, and is capable of real-time monitoring. While the conventional radiographic method uses volumetric registration, the optical system uses surface matching for patient alignment. The relative accuracy of these two methods has not yet been sufficiently investigated. This study aims to investigate the theoretical accuracy of the surface registration based on a simulation study using patient data. Methods: This study compares the relative accuracy of surface and volumetric registration in head-and-neck RT. The authors examined 26 patient data sets, each consisting of planning CT data acquired before treatment and patient setup CBCT data acquired at the time of treatment. As input data of surface registration, patient’s skin surfaces were created by contouring patient skin from planning CT and treatment CBCT. Surface registration was performed using the iterative closest points algorithm by point–plane closest, which minimizes the normal distance between source points and target surfaces. Six degrees of freedom (three translations and three rotations) were used in both surface and volumetric registrations and the results were compared. The accuracy of each method was estimated by digital phantom tests. Results: Based on the results of 26 patients, the authors found that the average and maximum root-mean-square translation deviation between the surface and volumetric registrations were 2.7 and 5.2 mm, respectively. The residual error of the surface registration was calculated to have an average of 0.9 mm and a maximum of 1.7 mm. Conclusions: Surface registration may lead to results different from those of the conventional volumetric registration. Only limited accuracy can be achieved for patient positioning with an approach based solely on surface information.

60 APPLIED LIFE SCIENCES↗

Experiences in long-term evaluation of mercury emission monitoring systems

Six mercury continuous emission monitoring (CEM) systems provided by two leading mercury (Hg) CEM system manufacturers were tested at five coal combustion utilities. The linearity, response time, day-to-day stability, efficiency of the Hg speciation modules, and ease of use were evaluated by following procedures specified in the Code of Federal Regulation Title 40 Part 75 (40 CFR Part 75). Mercury monitoring results from Hg CEM systems were compared to an EPA-recognized reference method. A sorbent trap sampling system was also evaluated in this study to compare the relative accuracy to the reference method as well as to Hg CEM systems. A conceptual protocol proposed by U.S. EPA (Method 30A) for using an Hg CEM system as the reference method for the Hg relative accuracy (RA) test was also followed to evaluate the workability of the protocol. This paper discusses the operational experience obtained from these field studies and the remaining challenges to overcome while using Hg CEM systems and the sorbent trap method for continuous Hg emission monitoring. 3 refs., 5 figs., 11 tabs.

01 COAL, LIGNITE, AND PEAT↗

Precision time distribution within a deep space communications complex

The Precision Time Distribution System (PTDS) at the Golstone Deep Space Communications Complex is a practical application of existing technology to the solution of a local problem. The problem was to synchronize four station timing systems to a master source with a relative accuracy consistently and significantly better than 10 microseconds. The solution involved combining a precision timing source, an automatic error detection assembly and a microwave distribution network into an operational system. Upon activation of the completed PTDS two years ago, synchronization accuracy at Goldstone (two station relative) was improved by an order of magnitude. It is felt that the validation of the PTDS mechanization is now completed. Other facilities which have site dispersion and synchronization accuracy requirements similar to Goldstone may find the PTDS mechanization useful in solving their problem. At present, the two station relative synchronization accuracy at Goldstone is better than one microsecond.

Curtright, J. B.↗

Ultraprecise Studies of the Thermal Expansion Coefficient of Diamond using Backscattering X-ray Diffraction

The linear thermal expansion coefficient of diamond crystals of type IIa and type Ia was measured in the temperature range from 10 to 295 K. Neither negative thermal expansion nor any substantial difference in the thermal expansion coefficient in crystals of the different types were observed. An empirical expression was obtained that approximates the temperature dependence of the thermal expansion coefficient of diamond. The T{sup 3} temperature dependence of a Debye solid holds below {approx}100 K with an accuracy of {approx}10{sup -8} K{sup -1}. A slight increase in the value of the lattice parameter was found for the Ia-type crystal, which suggests lattice dilatation by nitrogen impurity. The measurements were performed using Bragg diffraction in backscattering from diamond crystals of highly monochromatic 23.7 keV x rays with the recently demonstrated high relative accuracy of 1.2 x 10{sup -8} in the determination of the lattice parameter [S. Stoupin and Yu. Shvyd'ko Phys. Rev. Lett. 104 085901 (2010)].

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A simple formulation of the delta-four-stream approximation for radiative transfer parameterizations

A systematic development of the delta-four-stream approximation for calculations of radiative fluxes in planetary atmosphere is presented. It is shown that an analytic solution for this approximation can be derived explicitly, with minimum computational effort for flux calculations. Relative accuracy checks for reflection, transmission, and absorption for numerous asymmetry factors, single-scattering albedos, optical depths, and solar zenith angles have been performed with respect to the 'exact' results computed from the adding method for radiative transfer. Overall, results from the delta-four-stream approximation yield relative accuracies within about 5 percent. This approximation is well suited to radiative transfer parameterizations involving flux and heating calculations in aerosol and cloudy atmospheres.

Liou, Kuo-Nan↗

The Beauty and Complexity of the Brunt Ice Shelf from MOA and ICESat

Beginning in February 2003, NASA's Ice, Cloud, and land Elevation Satellite (ICESat) has determined surface elevations from approx. 86degN to 86degS latitude. To date, altimetry data have been acquired in a series of observation periods in repeated track patterns using all three Geoscience Laser Altimeter System (GLAS) lasers. This paper will focus on ice shelf elevation data that were obtained in 2003 across the Brunt Ice Shelf and the Stancomb-Wills Ice Tongue. Integrating the altimetry with the recently available MODIS Mosaic of Antarctica (MOA), quantifies the relative accuracy and precision of the resulting ice shelf elevations. Furthermore, the elevation data was processed onto an elevation grid, by regional interpolation across the area s complex glacial features only. Ice thickness estimation from the altimetry of the floating ice is discussed. ICESat operates at 40Hz and its elevation data is obtained every 172m along track. These elevations have a relative accuracy of about 14cm based on the standard deviation of low-slope crossover differences and a precision of close to 2cm for the Laser 2a, Release 21, GLA12 data used here.

Humbert, Angelika↗

Hybrid Metrology and 3D-AFM Enhancement for CD Metrology Dedicated to 28 nm Node and Below Requirements

The measurement accuracy is becoming one of the major components that have to be controlled in order to guarantee sufficient production yield. Already at the R and D level, we have to come up with the accurate measurements of sub-40 nm dense trenches and contact holes coming from 193 immersion lithography or E-Beam lithography. Current production CD (Critical Dimension) metrology techniques such as CD-SEM (CD-Scanning Electron Microscope) and OCD (Optical Critical Dimension) are limited in relative accuracy for various reasons (i.e electron proximity effect, outputs parameters correlation, stack influence, electron interaction with materials...). Therefore, time for R and D is increasing, process windows degrade and finally production yield can decrease because you cannot manufactured correctly if you are unable to measure correctly. A new high volume manufacturing (HVM) CD metrology solution has to be found in order to improve the relative accuracy of production environment otherwise current CD Metrology solution will very soon get out of steam.In this paper, we will present a potential Hybrid CD metrology solution that smartly tuned 3D-AFM (3D-Atomic Force Microscope) and CD-SEM data in order to add accuracy both in R and D and production. The final goal for 'chip makers' is to improve yield and save R and D and production costs through real-time feedback loop implement on CD metrology routines. Such solution can be implemented and extended to any kind of CD metrology solution. In a 2{sup nd} part we will discuss and present results regarding a new AFM3D probes breakthrough with the introduction of full carbon tips made will E-Beam Deposition process. The goal is to overcome the current limitations of conventional flared silicon tips which are definitely not suitable for sub-32 nm nodes production.

36 MATERIALS SCIENCE↗

Study of the one-way speed of light anisotropy with particle beams

Concepts of high precision studies of the one-way speed of light anisotropy are discussed. The high energy particle beam allows measurement of a one-way speed of light anisotropy (SOLA) via analysis of the beam momentum variation with sidereal phase without the use of synchronized clocks. High precision beam position monitors could provide accurate monitoring of the beam orbit and determination of the particle beam momentum with relative accuracy on the level of 10^-10, which corresponds to a limit on SOLA of 10^-18 with existing storage rings. A few additional versions of the experiment are also presented.

Wojtsekhowski, Bogdan B.↗

On-Road Validation of a Simplified Model for Estimating Real-World Fuel Economy

On-road fuel economy is known to vary significantly between individual trips in real-world driving conditions. This work introduces a methodology for rapidly simulating a specific vehicle's fuel economy over the wide range of real-world conditions experienced across the country. On-road test data collected using a highly instrumented vehicle is used to refine and validate this modeling approach. Here, model accuracy relative to on-road data collection is relevant to the estimation of 'off-cycle credits' that compensate for real-world fuel economy benefits that are not observed during certification testing on a chassis dynamometer.

33 ADVANCED PROPULSION SYSTEMS↗

The Aemulus Project. II. Emulating the Halo Mass Function

Existing models for the dependence of the halo mass function on cosmological parameters will become a limiting source of systematic uncertainty for cluster cosmology in the near future. We present a halo mass function emulator and demonstrate improved accuracy relative to state-of-the-art analytic models. In this work, mass is defined using an overdensity criteria of 200 relative to the mean background density. Our emulator is constructed from the AEMULUS simulations, a suite of 40 N-body simulations with snapshots from z = 3 to z = 0. These simulations cover the flat wCDM parameter space allowed by recent cosmic microwave background, baryon acoustic oscillation and SNe Ia results, varying the parameters w, Omega(m), Omega(b), sigma(8), N-eff, n(s), and H-0. We validate our emulator using five realizations of seven different cosmologies, for a total of 35 test simulations. These test simulations were not used in constructing the emulator, and were run with fully independent initial conditions. We use our test simulations to characterize the modeling uncertainty of the emulator, and introduce a novel way of marginalizing over the associated systematic uncertainty. We confirm nonuniversality in our halo mass function emulator as a function of both cosmological parameters and redshift. Our emulator achieves better than 1% precision over much of the relevant parameter space, and we demonstrate that the systematic uncertainty in our emulator will remain a negligible source of error for cluster abundance studies through at least the LSST Year 1 data set.

large-scale structure of universe↗

Venus Atmospheric Probe and Flyby Relay Spacecraft Cross-Link Tracking Impact on Relative Pointing Accuracy

Scientific exploration of Venus using an atmospheric probe requires relaying telemetry to Earth as the probe descends through the atmosphere to the surface of Venus. Using the flyby spacecraft to relay the probe telemetry to Earth will require precise carrier-to-probe pointing accuracy of the relay spacecraft’s antenna. NASA’s Deep Atmosphere Venus Investigation of Noble gases, Chemistry, and Imaging (DAVINCI) mission uses this carrier-to-probe relay technique. Although DAVINCI includes a coherent cross-link for science, this is not baselined for navigation tracking. This paper explores the potential effectiveness of cross-link tracking for reducing trajectory uncertainty and improving spacecraft-to-probe pointing.

DAVINCI↗

VERSION 1 OF THE HUBBLE SOURCE CATALOG

The Hubble Source Catalog is designed to help optimize science from the Hubble Space Telescope (HST) by combining the tens of thousands of visit-based source lists in the Hubble Legacy Archive (HLA) into a single master catalog. Version 1 of the Hubble Source Catalog includes WFPC2, ACS/WFC, WFC3/UVIS, and WFC3/IR photometric data generated using SExtractor software to produce the individual source lists. The catalog includes roughly 80 million detections of 30 million objects involving 112 different detector/filter combinations, and about 160,000 HST exposures. Source lists from Data Release 8 of the HLA are matched using an algorithm developed by Budavári and Lubow. The mean photometric accuracy for the catalog as a whole is better than 0.10 mag, with relative accuracy as good as 0.02 mag in certain circumstances (e.g., bright isolated stars). The relative astrometric residuals are typically within 10 mas, with a value for the mode (i.e., most common value) of 2.3 mas. The absolute astrometric accuracy is better than 0{sup ″} .1 for most sources, but can be much larger for a fraction of fields that could not be matched to the PanSTARRS, SDSS, or 2MASS reference systems. In this paper we describe the database design with emphasis on those aspects that enable the users to fully exploit the catalog while avoiding common misunderstandings and potential pitfalls. We provide usage examples to illustrate some of the science capabilities and data quality characteristics, and briefly discuss plans for future improvements to the Hubble Source Catalog.

79 ASTRONOMY AND ASTROPHYSICS↗

On the application of multifrequency polarimetric radar observations for sea-ice classification

The use of multifrequency polarimetric radar imagery to enhance the ability to separate different sea-ice types using single-frequency, single-polarization synthetic aperture radar (SAR) data is investigated. Backscatter characteristics of six radiometrically and polarimetrically distinct sea-ice types are selected in an unsupervised range-dependent analysis of multifrequency polarimetric SAR data using the maximum a posteriori (MAP) polarimetric classifier. Maximum ice discrimination is achieved with combined C- and L-band full polarimetry, and collocated passive microwave imagery suggests greater than 90 percent classification accuracy. C-band VV-pol alone achieves only 68 percent relative accuracy because it confuses multiyear and rough compressed first year ice. L-band, relative classification accuracy is 75 percent, 83 percent, and 85 percent, using HH-pol, HH- and VV-combined, or the full polarimetry, respectively. P-band is less accurate. Combinations of two frequencies at a single polarization show the greatest improvement over a single channel.

Rignot, Eric↗

SOLAR VARIABILITY FROM 240 TO 1750 nm IN TERMS OF FACULAE BRIGHTENING AND SUNSPOT DARKENING FROM SCIAMACHY

The change of spectral decomposition of the total radiative output on various timescales of solar magnetic activity is of large interest to terrestrial and solar-stellar atmosphere studies. Starting in 2002, SCIAMACHY was the first satellite instrument to observe daily solar spectral irradiance (SSI) continuously from 230 nm (UV) to 1750 nm (near-infrared; near-IR). In order to address the question of how much UV, visible (vis), and IR spectral regions change on 27 day and 11 year timescales, we parameterize short-term SSI variations in terms of faculae brightening (Mg II index) and sunspot darkening (photometric sunspot index) proxies. Although spectral variations above 300 nm are below 1% and, therefore, well below the accuracy of absolute radiometric calibration, relative accuracy for short-term changes is shown to be in the per mill range. This enables us to derive short-term spectral irradiance variations from the UV to the near-IR. During Halloween solar storm in 2003 with a record high sunspot area, we observe a reduction of 0.3% in the near-IR to 0.5% in the vis and near-UV. This is consistent with a 0.4% reduction in total solar irradiance (TSI). Over an entire 11 year solar cycle, SSI variability covering simultaneously the UV, vis, and IR spectral regions have not been directly observed so far. Using variations of solar proxies over solar cycle 23, solar cycle spectral variations have been estimated using scaling factors that best matched short-term variations of SCIAMACHY. In the 300-400 nm region, which strongly contributes to TSI solar cycle change, a contribution of 34% is derived from SCIAMACHY observations, which is lower than the reported values from SUSIM satellite data and the empirical SATIRE model. The total UV contribution (below 400 nm) to TSI solar cycle variations is estimated to be 55%.

99 GENERAL AND MISCELLANEOUS↗

Prelaunch Instrument Calibration in the Real World: The GOES Example

The pre-launch ground infrared calibration of the Geostationary Operational Environmental Satellite (GOES) N-Q Imager and Sounder is presented. Ground calibration provides information necessary to the accurate on-orbit calibration of these radiometers. Infrared channels are calibrated in a thermal vacuum environment, under minimum and maximum mission operation temperatures, using a variable-temperature warm target to simulate the Earth scene and a cold target to simulate the space scene. Brightness temperatures derived from observation of the instrument internal calibration target, used for on-orbit calibration, are compared to brightness temperatures of the external calibration target as a check of relative accuracy using these two sources. Changes to the GOES N-Q specification from GOES I-M are highlighted, as well as results of noise, relative calibration accuracy, and spectral response performance to date. For completeness, results of spatial and pointing performance will be presented. Enhancements to test methodology and data processing techniques are highlighted throughout.

Murphy-Morris, J.↗