Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A linear, separable two-parameter model for dual energy CT imaging of proton stopping power computation

Purpose: To evaluate the accuracy and robustness of a simple, linear, separable, two-parameter model (basis vector model, BVM) in mapping proton stopping powers via dual energy computed tomography (DECT) imaging. Methods: The BVM assumes that photon cross sections (attenuation coefficients) of unknown materials are linear combinations of the corresponding radiological quantities of dissimilar basis substances (i.e., polystyrene, CaCl{sub 2} aqueous solution, and water). The authors have extended this approach to the estimation of electron density and mean excitation energy, which are required parameters for computing proton stopping powers via the Bethe–Bloch equation. The authors compared the stopping power estimation accuracy of the BVM with that of a nonlinear, nonseparable photon cross section Torikoshi parametric fit model (VCU tPFM) as implemented by the authors and by Yang et al. [“Theoretical variance analysis of single- and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissues,” Phys. Med. Biol. 55, 1343–1362 (2010)]. Using an idealized monoenergetic DECT imaging model, proton ranges estimated by the BVM, VCU tPFM, and Yang tPFM were compared to International Commission on Radiation Units and Measurements (ICRU) published reference values. The robustness of the stopping power prediction accuracy of tissue composition variations was assessed for both of the BVM and VCU tPFM. The sensitivity of accuracy to CT image uncertainty was also evaluated. Results: Based on the authors’ idealized, error-free DECT imaging model, the root-mean-square error of BVM proton stopping power estimation for 175 MeV protons relative to ICRU reference values for 34 ICRU standard tissues is 0.20%, compared to 0.23% and 0.68% for the Yang and VCU tPFM models, respectively. The range estimation errors were less than 1 mm for the BVM and Yang tPFM models, respectively. The BVM estimation accuracy is not dependent on tissue type and proton energy range. The BVM is slightly more vulnerable to CT image intensity uncertainties than the tPFM models. Both the BVM and tPFM prediction accuracies were robust to uncertainties of tissue composition and independent of the choice of reference values. This reported accuracy does not include the impacts of I-value uncertainties and imaging artifacts and may not be achievable on current clinical CT scanners. Conclusions: The proton stopping power estimation accuracy of the proposed linear, separable BVM model is comparable to or better than that of the nonseparable tPFM models proposed by other groups. In contrast to the tPFM, the BVM does not require an iterative solving for effective atomic number and electron density at every voxel; this improves the computational efficiency of DECT imaging when iterative, model-based image reconstruction algorithms are used to minimize noise and systematic imaging artifacts of CT images.

61 RADIATION PROTECTION AND DOSIMETRY↗

A new Role of Proficiency Testing in Nuclear Analytical Work

The most recent definition of measurement result requires a statement of uncertainty whenever results obtained by nuclear or other quantitative methods of analysis are reported. Proficiency testing (PT) therefore must include the ability of laboratories to present not only unbiased quantity values, but reliable estimates of their uncertainty. Hence, a reference value with the smallest possible uncertainty is needed to ascertain the proficiency of laboratories reporting results with lower than average uncertainty. A strategy based on the T-statistic is proposed leading to an accepted reference value that fully reflects the uncertainties reported by participants in a PT-scheme and permits calculation of En numbers to distinguish whether or not measurement results are consistent with the accepted definition of the measurand. The strategy is applied to PT-data from a recent international laboratory intercomparison of uranium isotopic ratios with very low reported uncertainties. In the paper this example is used to present the situation in the nuclear field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Value of Information References

This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.

15 GEOTHERMAL ENERGY↗

Pool power control in remelting systems

An apparatus for and method of controlling a remelting furnace comprising adjusting current supplied to an electrode based upon a predetermined pool power reference value and adjusting the electrode drive speed based upon the predetermined pool power reference value.

47 OTHER INSTRUMENTATION↗

AWE neutron spectrometry results from Godiva-IV (NCERC) characterization - Paper 135

In recent years, it was deemed necessary for the Godiva-IV critical assembly - along with other assemblies collectively forming what is now known as the National Critical Experiments Research Center (NCERC) - to relocate to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). An experiment was proposed (IER-148) under the Nuclear Criticality Safety Program for an international inter-comparison of Nuclear Accident Dosimetry (NAD) using the Godiva-IV assembly, in order to arrest the long term decline in the testing and validation of these systems. Due to the knock-on effect of the change of location on the neutron leakage spectrum, however, new reference points must be established. As a precursor to the intercomparison an additional experiment (IER-147) was proposed with the aim of measuring these reference values for the current Godiva-IV radiation field in the DAF. To establish the reference values Godiva was run in both a sub-critical steady-state mode and a super prompt-critical, pulsed mode. AWE provided neutron spectrometry capabilities in the form of a ROSPEC and Bonner sphere Spectrometer (BSS) for the steady-state experiment, and a Passive Bonner sphere Spectrometer (PBSS) for the pulsed experiment. Neutron leakage spectrum measurements carried out by AWE have been used to determine reference doses around Godiva which can be used for future NAD inter-comparisons. A good comparison of steady-state and pulsed spectra indicates a strong likelihood of being able to relate the power level of both operational methods of the reactor for future work in other fields. Further work is required to determine the fidelity of the thermal peak and it is the intention of AWE to bring additional thermal information to the unfolding process through the incorporation of supplementary activation foils used in the irradiations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Calculation of Ambient (H*(10)) and Personal (H p (10)) Dose Equivalent from a 252 Cf Neutron Source

The neutron emission rate from radioisotope neutron sources such as 252 Cf sources can be calibrated by the National Institute of Standards and Technology (NIST) by the manganous sulfite bath method. This calibration method does not compute the dose or dose equivalent rate from the source. Because there is no accepted transfer standard for neutron dose measurements, secondary calibration facilities are responsible for determining their own neutron dose factors. This report describes a neutron source and irradiation apparatus in use at the Pacific Northwest National Laboratory Calibration Facility. The neutron source is a SR-Cf-3000 design 252 Cf neutron source. The neutron source is contained in an aluminum transfer capsule that is used to transport the neutron source between its storage location and it’s irradiation location. During irradiations, the source is located in a transfer tube assembly that consists of two concentric aluminum tubes. When moderated neutrons are desired, the transfer tube assembly is surrounded by a sphere that is filled with D 2 O as a moderating medium. Ambient dose equivalent (H*(10)) and Personal dose equivalent (H p (10)) dose rates and dose conversion factors were calculated for moderated and unmoderated neutron spectra based on the data provided in ICRP Publication 74. The neutron fluence-to-dose-equivalent conversion factors calculated for this report are summarized and compared to published values in Table 47. The calculated coefficients for the unmoderated 252 Cf spectra agree very well with published reference values, within about 2%. The calculated coefficients for the D 2 O moderated 252 Cf spectra, however, differ from published reference values by about 22%. The PNNL coefficients are higher than the published values which could be interpreted to mean that the PNNL D 2 O moderated spectrum is harder, i.e. higher average energy, than the spectrum published by the ISO (2000), which formed the basis for the published coefficients. The D 2 O moderating sphere in use at PNNL contains less D 2 O moderator than did the D 2 O moderating sphere that was used to calculate the ISO spectrum and this is the likely reason for much of the spectral differences. The exact location of the 252 Cf activity in the source encapsulation is unknown. Preliminary measurements, not described in this report, indicate that the activity may be offset from the location that has been assumed in the past. Corrections for the offset are being proposed and will be the subject of another report. This report was written in a calculation package format to help meet various Quality Assurance requirements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

UV-filters and musk fragrances in seafood commercialized in Europe Union: Occurrence, risk and exposure assessment

Highlights: • Largest survey on UV-Fs and musks in seafood commercialized in Europe. • Farmed seabream showed the highest average concentration of UV-Fs. • Wild mackerel showed the highest average concentration of polycyclic musks. • UV-Fs and musks in raw samples were far below the estimated toxicological reference value. In the framework of the FP7 ECsafeSeafood project, 62 seafood samples commercialized in Europe Union from several representative species – mackerel, tuna, salmon, seabream, cod, monkfish, crab, shrimp, octopus, perch and plaice – were analysed for residues of 21 personal care products (PCPs), including 11 UV-filters (UV-Fs) and 10 musk fragrances (musks). PCPs analysis were performed by Quick, Easy, Cheap, Effective Rugged, Safe (QuEChERS), combined with liquid-liquid extraction (LLE) or dispersive solid-phase extraction (dSPE), followed by gas chromatography-tandem mass spectrometry (GC-MS/MS). The results showed the presence in a wide range of samples of nine out of eleven UV-Fs compounds analysed, namely 2-ethylhexyl salicylate (EHS), 2-ethylhexyl,4-methoxycinnamate (EHMC), 4-methylbenzylidenecamphor (4-MBC), benzophenone-1 (BP1), benzophenone-3 (BP3), isoamyl-4-methoxycinnamate (IMC), 2,2′-dihydroxy-4,4′-dimethoxybenzophenone (DHMB), homosalate (HS), and octocrylene (OC), whereas galaxolide (HHCB), galaxolide lactone (HHCB-lactone), and tonalide (AHTN) were the most found musks. The potential risks to human health associated with the exposure to eight of the more prevalent PCPs – EHS, EHMC, 4-MBC, BP1, BP3, IMC, HHCB, and AHTN - through seafood consumption were assessed for consumers from five European countries (Belgium, Ireland, Italy, Portugal and Spain). Results showed that the human exposure to UV-Fs and musks estimated from the concentration values found in seafood and the daily consumption of concerned seafood species, were far below toxicological reference values.

54 ENVIRONMENTAL SCIENCES↗

Validation of the TOPAS Monte Carlo toolkit for HDR brachytherapy simulations

The goal of this work is to validate the user-friendly Geant4-based Monte Carlo toolkit TOol for PArticle Simulation (TOPAS) for brachytherapy applications. Brachytherapy simulations performed with TOPAS were systematically compared with published TG-186 reference data. The photon emission energy spectrum, the air-kerma strength, and the dose-rate constant of the model-based dose calculation algorithm (MBDCA)-WG generic Ir-192 source were extracted. For dose calculations, a track-length estimator was implemented. Additionally, the four Joint AAPM/ESTRO/ABG MBDCA-WG test cases were evaluated through histograms of the local and global dose difference volumes. A prostate, a palliative lung, and a breast case were simulated. For each case, the dose ratio map, the histogram of the global dose difference volume, and cumulative dose-volume histograms were calculated. The air-kerma strength was (9.772 ± 0.001) × 10 -8 U Bq -1 (within 0.3% of the reference value). The dose-rate constant was 1.1107 ± 0.0005 cGy h -1 U -1 (within 0.01% of the reference value). For all cases, at least 96.9% of voxels had a local dose difference within [-1%, 1%] and at least 99.9% of voxels had a global dose difference within [-0.1%, 0.1%]. The implemented track-length estimator scorer was more efficient than the default analog dose scorer by a factor of 237. For all clinical cases, at least 97.5% of voxels had a global dose difference within [-1%, 1%]. Dose-volume histograms were consistent with the reference data. TOPAS was validated for high-dose-rate brachytherapy simulations following the TG-186 recommended approach for MBDCAs. Built on top of Geant4, TOPAS provides broad access to a state-of-the-art Monte Carlo code for brachytherapy simulations.

59 BASIC BIOLOGICAL SCIENCES↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A set of 4D pediatric XCAT reference phantoms for multimodality research

Purpose: The authors previously developed an adult population of 4D extended cardiac-torso (XCAT) phantoms for multimodality imaging research. In this work, the authors develop a reference set of 4D pediatric XCAT phantoms consisting of male and female anatomies at ages of newborn, 1, 5, 10, and 15 years. These models will serve as the foundation from which the authors will create a vast population of pediatric phantoms for optimizing pediatric CT imaging protocols. Methods: Each phantom was based on a unique set of CT data from a normal patient obtained from the Duke University database. The datasets were selected to best match the reference values for height and weight for the different ages and genders according to ICRP Publication 89. The major organs and structures were segmented from the CT data and used to create an initial pediatric model defined using nonuniform rational B-spline surfaces. The CT data covered the entire torso and part of the head. To complete the body, the authors manually added on the top of the head and the arms and legs using scaled versions of the XCAT adult models or additional models created from cadaver data. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from a template XCAT phantom (male or female 50th percentile adult) to the target pediatric model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. The masses of the organs in each phantom were matched to the reference values given in ICRP Publication 89. The new reference models were checked for anatomical accuracy via visual inspection. Results: The authors created a set of ten pediatric reference phantoms that have the same level of detail and functionality as the original XCAT phantom adults. Each consists of thousands of anatomical structures and includes parameterized models for the cardiac and respiratory motions. Based on patient data, the phantoms capture the anatomic variations of childhood, such as the development of bone in the skull, pelvis, and long bones, and the growth of the vertebrae and organs. The phantoms can be combined with existing simulation packages to generate realistic pediatric imaging data from different modalities. Conclusions: The development of patient-derived pediatric computational phantoms is useful in providing variable anatomies for simulation. Future work will expand this ten-phantom base to a host of pediatric phantoms representative of the public at large. This can provide a means to evaluate and improve pediatric imaging devices and to optimize CT protocols in terms of image quality and radiation dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

European Measurement Comparisons of Environmental Radioactivity

The scheme of European measurement comparisons to verify radioactivity monitoring in the European Union is briefly explained. After a review of comparisons conducted during the years 1990, the approach of IRMM organising these comparisons since 2003 is presented. IRMM is providing comparison samples with a reference value traceable to the SI units and which is fully documented to all participants and national authorities after completion of the comparison. The sample preparation and determination of traceable reference values at IRMM, the sample treatment and measurement in the participating laboratories, as well as the evaluation of comparison results are described in some detail using the example of an air filter comparison. The results of a comparison to determine metabolised {sup 40}K, {sup 90}Sr and {sup 137}Cs in milk powder are presented as well. The necessary improvements in the estimation of measurement uncertainty by the participating laboratories are discussed. The performance of individual laboratories which have participated in at least four comparison exercises over the years is studied in terms of observable trends.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

Self-interaction-free electric dipole polarizabilities for atoms and their ions using the Fermi-Löwdin self-interaction correction

The static electric dipole polarizability of a system is a measure of the binding of its electrons. In density functional theory calculations, this binding is weakened by the presence of unphysical self-interaction in the density functional approximation (DFA), leading to overestimates of polarizabilities. In this work, to investigate this systematically we compare polarizabilities for the atoms from H to Ar and their anions and cations calculated in several DFAs and the corresponding self-interaction-corrected (SIC) DFAs with experiment and with high-level quantum chemistry reference values. The SIC results are obtained using the Fermi-Löwdin orbital self-interaction correction (FLO-SIC) method. Removing self-interaction generally leads to smaller polarizabilities that agree significantly better with reference values. In conclusion, we find that FLO-SIC improves the performance of the local spin density approximation and the generalized gradient approximation (GGA) for polarizabilities to a quality that is comparable to so-called rung 4 functionals, but slightly degrades the performance of the strongly constrained and appropriately normed meta-GGA functional.

74 ATOMIC AND MOLECULAR PHYSICS↗

Calibration of helical tomotherapy machine using EPR/alanine dosimetry

Purpose: Current codes of practice for clinical reference dosimetry of high-energy photon beams in conventional radiotherapy recommend using a 10x10 cm{sup 2} square field, with the detector at a reference depth of 10 cm in water and 100 cm source to surface distance (SSD) (AAPM TG-51) or 100 cm source-to-axis distance (SAD) (IAEA TRS-398). However, the maximum field size of a helical tomotherapy (HT) machine is 40x5 cm{sup 2} defined at 85 cm SAD. These nonstandard conditions prevent a direct implementation of these protocols. The purpose of this study is twofold: To check the absorbed dose in water and dose rate calibration of a tomotherapy unit as well as the accuracy of the tomotherapy treatment planning system (TPS) calculations for a specific test case. Method: Both topics are based on the use of electron paramagnetic resonance (EPR) using alanine as transfer dosimeter between the Laboratoire National Henri Becquerel (LNHB) {sup 60}Co-{gamma}-ray reference beam and the Institut Curie's HT beam. Irradiations performed in the LNHB reference {sup 60}Co-{gamma}-ray beam allowed setting up the calibration method, which was then implemented and tested at the LNHB 6 MV linac x-ray beam, resulting in a deviation of 1.6% (at a 1% standard uncertainty) relative to the reference value determined with the standard IAEA TRS-398 protocol. Results: HT beam dose rate estimation shows a difference of 2% with the value stated by the manufacturer at a 2% standard uncertainty. A 4% deviation between measured dose and the calculation from the tomotherapy TPS was found. The latter was originated by an inadequate representation of the phantom CT-scan values and, consequently, mass densities within the phantom. This difference has been explained by the mass density values given by the CT-scan and used by the TPS which were not the true ones. Once corrected using Monte Carlo N-Particle simulations to validate the accuracy of this process, the difference between corrected TPS calculations and alanine measured dose values was then found to be around 2% (with 2% standard uncertainty on TPS doses and 1.5% standard uncertainty on EPR measurements). Conclusion: Beam dose rate estimation results were found to be in good agreement with the reference value given by the manufacturer at 2% standard uncertainty. Moreover, the dose determination method was set up with a deviation around 2% (at a 2% standard uncertainty).

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessment of two hybrid van der Waals density functionals for covalent and non-covalent binding of molecules

Two hybrid van der Waals density functionals (vdW-DFs) are developed using 25% Fock exchange with (i) the consistent-exchange vdW-DF-cx functional [K. Berland and P. Hyldgaard, Phys. Rev. B 89, 035412 (2014)] and (ii) with the vdW-DF2 functional [K. Lee et al., Phys. Rev. B 82, 081101 (2010)]. The ability to describe covalent and non-covalent binding properties of molecules is assessed. For properties related to covalent binding, atomization energies (G2-1 set), molecular reaction energies (G2RC set), and ionization energies (G21IP set) are benchmarked against experimental reference values. We find that hybrid-vdW-DF-cx yields results that are rather similar to those of the standard non-empirical hybrid PBE0 [C. Adamo and V. Barone, J. Chem. Phys. 110, 6158 (1999)], with mean average deviations (MADs) of 4.9 and 5.0 kcal/mol for the G2-1 set, respectively. In this comparison, experimental reference values are used, back corrected by wavefunction-based quantum-chemistry calculations of zero-point energies. Hybrid vdW-DF2 follows somewhat different trends, showing on average significantly larger deviations from the reference energies, with a MAD of 14.5 kcal/mol for the G2-1 set. Non-covalent binding properties of molecules are assessed using the S22 benchmark set of non-covalently bonded dimers and the X40 set of dimers of small halogenated molecules, using wavefunction-based quantum chemistry results as references. For the S22 set, hybrid-vdW-DF-cx performs better than standard vdW-DF-cx for the mostly hydrogen-bonded systems, with MAD dropping from 0.6 to 0.3 kcal/mol, but worse for purely dispersion-bonded systems, with MAD increasing from 0.2 to 0.6 kcal/mol. Hybrid-vdW-DF2 offers a slight improvement over standard vdW-DF2. Similar trends are found for the X40 set, with hybrid-vdW-DF-cx performing particularly well for binding energies involving the strongly polar hydrogen halides, but poorly for systems with tiny binding energies. Our study of the X40 set reveals the potential of mixing Fock exchange with vdW-DF, but also highlights shortcomings of the hybrids constructed here. In conclusion, the solid performance of hybrid-vdW-DF-cx for covalent-bonded systems, as well as the strengths and issues uncovered for non-covalently bonded systems, makes this study a good starting point for developing even more accurate hybrid vdW-DFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Air Toxics Health Effects Database (ATHED)

The Air Toxics Health Effects Database (ATHED) is currently used by the EPA's Office of Air Quality Planning and Standards (OAQPS) to support risk assessments for the Residual Risk Program. An assessment of the residual risk is required to be performed at a specified time (typically 8years) following the promulgation of a technology-based Maximum Achievable Control Technologies (MACT) standard. The goal of the Residual Risk Program is to assure that the risk that remains after MACT standards are implemented (i.e., the 'residual risk') is acceptable, and if not, to propose additional regulations to mitigate those risks. ATHED maintains all available reference values for each chemical as separate data records, and includes values for all exposure durations (acute, short-term, subchronic and chronic). These values are used as benchmarks to determine acceptable exposure levels to the hazardous air pollutants (HAPs) listed in Section 112 of the Clean Air Act. ATHED also provides useful background information on the uncertainty and/or modifying factors that were applied in the derivation of each reference value, as well as the point of departure and the critical study/studies. To facilitate comparisons across durations for a specific chemical, ATHED data can be graphically presented.

60 APPLIED LIFE SCIENCES↗

TIME-AVERAGE-BASED METHODS FOR MULTI-ANGULAR SCALE ANALYSIS OF COSMIC-RAY DATA

Over the past decade, a number of experiments dealt with the problem of measuring the arrival direction distribution of cosmic rays, looking for information on the propagation mechanisms and the identification of their sources. Any deviation from the isotropy may be regarded to as a signature of unforeseen or unknown phenomena, mostly if well localized in the sky and occurring at low rigidity. It induced experimenters to search for excesses down to angular scales as narrow as 10 Degree-Sign , disclosing the issue of properly filtering contributions from wider structures. A solution commonly envisaged was based on time-average methods to determine the reference value of cosmic-ray flux. Such techniques are nearly insensitive to signals wider than the time window in use, thus allowing us to focus the analysis on medium- and small-scale signals. Nonetheless, the signal often cannot be excluded in the calculation of the reference value, which induces systematic errors. The use of time-average methods recently revealed important discoveries about the medium-scale cosmic-ray anisotropy, present both in the northern and southern hemispheres. It is known that the excess (or deficit) is observed as less intense than in reality and that fake deficit zones are rendered around true excesses because of the absolute lack of knowledge a priori of which signal is true and which is not. This work is an attempt to critically review the use of time-average-based methods for observing extended features in the cosmic-ray arrival distribution pattern.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Godiva-IV Dosimetry Exercise 2022 Preliminary Results

Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.

BOttle Manikin ABsorption (BOMAB)↗