Ultra-fast single-crystal CVD diamonds in the particle time-of-flight (PTOF) detector for low yield burn-history measurements on the NIF (invited)

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium–tritium (DT) fusion plasmas. PTOF-inferred DT burn width numbers compare well with widths inferred from the gamma reaction history diagnostic on mid-yield (1013–1015) shots, where both systems are capable of making this measurement. These new capabilities could be extended to 2.5 MeV deuterium–deuterium neutrons from D plasmas and to even lower yield by reducing the detector standoff distance to 10 cm; a design for this is also presented.

42 ENGINEERING↗

Interplay of intercalation dynamics and lithium plating in monolithic and architectured graphite anodes during fast charging

Fast charging of high-capacity anodes is challenging due to lithium plating reactions, which lead to poor cycling performance and safety concerns. Thus, accurate predictions of plating onset and an understanding of this electrochemical process are crucial for robust battery design. However, the most commonly used models, based on porous electrode theory (e.g., the pseudo-2D model), are notoriously difficult to calibrate due to their complexity, limiting their predictive power. This work studies the process of lithium plating during fast charging of (small-particle) graphite half-cells by measuring local reaction progression and plating behavior using optical operando techniques. These experiments employ a realistic 1D graphite electrode geometry with commercially-relevant mass loading charged at fast charge rates. It is demonstrated that the local reaction progression and plating onset can not only be predicted accurately with a p2D numerical model, but that these processes follow a simple scaling law. Remarkably, the entire reaction histories of different electrodes charged at different rates (e.g., 160 μm thickness at 0.5C, 111 μm at 1C or 66 μm at 4C) were observed to have self-similar intercalation profiles. It is demonstrated that plating onset is in turn governed by the reaction profile which explains why both processes exhibit the same scaling behavior. Finally, operando measurements of local reaction dynamics are conducted for the first time in electrodes with channeled architectures, quantitatively determining how channels affect reaction uniformity and plating onset. Together, these results reveal underlying simplicity in the complex electrochemical environment of fast charging and lithium plating, improving understanding of this process. These fundamental insights are broadly applicable for design processes, modeling and experimental evaluation of lithium ion batteries.

25 ENERGY STORAGE↗

Carbon ablator areal density at fusion burn: Observations and trends at the National Ignition Facility

For inertial confinement fusion experiments, the pusher is composed of a high-density deuterium tritium cyrogenic fuel layer and an ablator, often made of carbon. In an ideal, no-mix implosion, increasing the areal density of the pusher transfers more pressure to the hot spot and increases the hot spot confinement time. There has been a lack of knowledge about the final compressed state of the ablator for implosions at the National Ignition Facility. 14 MeV fusion neutrons inelastically scattering on the remaining carbon ablator excites a nuclear metastable state that emits a prompt 4.4 MeV gamma ray. The gamma reaction history diagnostic data, when reduced by a new data analysis technique, can isolate and measure the carbon gamma rays, which are proportional to the areal density of the ablator during fusion burn. The trends over many National Ignition Facility campaigns show that the ablator areal density is weakly sensitive to the maximum shell velocity, the cold fuel radius, the ablator mass remaining, or the laser picket intensity. Controlled parameter scans reveal that, for specific campaigns, ablator compression has a strong dependence on laser coast time, high Z dopants, and the laser drive foot duration. Using a model of the compressed ablator density profile reveals that the greatest variation of the ablator areal density comes from its thickness, with highly compressed, thin layers having high areal density values. The compression and thickness of the ablator are other metrics that designers should understand to differentiate the types of capsule degradation and maximize the inertial confinement fusion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time resolved ablator areal density during peak fusion burn on inertial confinement fusion implosions

Near peak compression, inertial confinement fusion implosions release both deuterium–tritium (DT) fusion gamma rays and neutron induced gamma rays from carbon from the areal density of the remaining ablator shell. The gamma reaction history diagnostic makes a time resolved measurement of both. Across many recent implosions, the carbon gamma ray peak arrives systematically 11 ± 10 ps later compared to DT fusion burn. The timing shift is consistent with the carbon areal density increasing throughout the peak of the fusion burn, implying that the carbon portion of the capsule continues to converge. A model finds that the observed timing shift is consistent with a 4π averaged carbon ablator inward velocity of 80 μm/ns for the contemporary National Ignition Facility implosions. In this work, the timing shift is possibly related to the energy balance of the implosion, with the expectation that a high performing, igniting capsule would see the carbon gamma rays arrive before the DT fusion peak.

Nuclear fusion↗

Total fusion yield measurements using deuterium–tritium gamma rays

The deuterium–tritium (DT) fusion reaction, D ( T , γ ) 5 He , has a rare (4.2 × 10 – 5 ) branching ratio that releases a ~16 MeV gamma ray instead of the more common 14.1 MeV fusion neutron. These fusion gamma rays can be used as a complementary source of measuring the net fusion yield of experiments. Fusion gamma rays have the advantage of having negligible Doppler broadening, being isotropic and less down-scattered compared to fusion neutrons. At the National Ignition Facility, we measured the DT fusion gamma rays by the Gamma Reaction History diagnostic that thresholds to only measure >10 MeV gamma rays. After removing a ~12% contribution from neutron capture interactions in deuterium, D ( n , γ ) T , and carbon, 12 C ( n , γ ) 13 C , the deviation between GRH measurements and neutron-based yield measurements has been reduced to 10%. Further improvements are needed for detailed physics comparison.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inferring fusion nuclear burnwidths with low gain photomultiplier impulse response functions

When an inertial confinement fusion implosion is compressed, it maintains thermonuclear density and temperatures for a very short time scale, about 100 ps. The Gamma Reaction History diagnostic measures the time evolution of the fusion burn, but its temporal resolution is limited by the use of a photomultiplier tube (PMT) to amplify the photon signal. Multichannel plate-based PMTs have a fast (~120 ps) full-width at half-max impulse response function (IRF), but the time scale is similar to the incoming physics signal. An analysis routine is used to remove the effect of the PMT IRF and infer the incident fusion burnwidth. With the National Ignition Facility achieving ignition and creating much brighter signals, the PMTs are run at gains three orders of magnitude lower than nominal operation. Calibration at these settings shows the PMT IRFs get ~15% wider. Taking the gain-dependent IRF can affect the inferred nuclear burnwidths by up to ~15%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel high frequency, high bandwidth, three phase Mach–Zehnder optical data link

In inertial confinement fusion, hydrogen isotopes are fused together under high pressures and temperatures. Typically, the duration of these experiments is incredibly short, on the order of around 60–150 ps. Due to the high radiation environment, a detector’s signal is typically data linked far distances to a protected location. The diagnostic challenge for fusion reaction history measurements is to measure signals of interest maximizing dynamic range while also maintaining time resolution on the order of 10 ps. In this work, we present a new experimental optical data link used to efficiently transport diagnostic signals over great distances to the recording system while not restricting the dynamic range. The concept of a three phase Mach–Zehnder modulator system is introduced as well as a description of the physical prototype. The initial results from testing at the OMEGA facility show that this system is a viable method for signal transportation.

47 OTHER INSTRUMENTATION↗

Observation of kinetic mix enhancement in thin-shell OMEGA implosions

Recent separated reactant experiments for thin-shell (6 µ⁢m) shock-driven implosions on OMEGA have demonstrated significant mix from a buried deuterated layer of the shell into the hot spot. Time resolved D 3 He-p reaction history data demonstrate a (50 ± 20)⁢ ps shift earlier in peak nuclear emission for separated reactant experiments relative to control, in contrast to past experimental data for thicker, 20 µ⁢m shells with no laser burn through that show a 75 ps delay due to the time required for hydrodynamic instabilities to develop. This contrast suggests that the mix mechanism was not hydrodynamic. Ion kinetic simulations utilizing fall line analyses show much closer agreement with mix yield and temperature than diffusion models, predicting a D 3 He-p mix yield of 1.7 × 10 9 as compared to the experimental value of 9.3⁢ (±2.1) × 10 8 . This is three orders of magnitude closer than the fall line analysis from a hydrodynamic simulation with an inline diffusive mix model, which suggests minimal mix and D 3 He-p yields of 5×10 5 . This makes kinetic mechanisms the only feasible explanation for the mix seen, demonstrating impact of a non-standard mix mechanism. An analytical model of this kinetic mix mechanism suggests that it can remain significant in situations when the shell expands significantly to low densities, and diffusive models predict negligible mix. Finally, kinetic mix will impact multiple types of high energy density, laser-driven fusion experiments including high-adiabat direct drive cryoexperiments, nuclear cross section experiments, and thin-shell polar direct drive experiments used to tune heat conduction models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uncertainty about the Uncertainty [Slides]

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable result in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates, in comparison to the measurement uncertainty. Range of true values depends on the physics of the experiment, while measurement uncertainty depends on the measurement method (properties of the detector not of the experiment). When data from one–of–a kind experiment are analyzed, only the measurement uncertainty is reported. It gives no information about the range, in which the true values of experiment would spread if the experiment was repeated. A frequently used approximation, that if a physical quantity is measured as a function of time, only measurement of this quantity, produces uncertainty is also in some real experiments fare to strong. Example: In reaction history time measurement uncertainty propagated to alpha dominated under certain conditions over the flux measurement uncertainty propagated to alpha. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Cross-Correlation Inter-Detector Timing

Inter-detector timing is one of the key steps for compositing signals obtained by multiple detectors. Conventionally this is done via inversing time gamma functions of individual detectors and then matching their times at the same gamma level. The applicability of the gamma inverse approach is often restricted to the monotonic gamma functions. This presentation presents a novel approach for inter-detector timing. This new approach introduced an enhanced cross-correlation of gamma values between two time intervals of two detectors. If this enhanced cross-correlation is close to 1, then both intervals should cover the same gamma segment of the signal. Consequently the time shift between the two detector can be derived from the time shift of the these two time intervals. This work will be presented at the 4th Annual Reaction History Analysis Workshop in North Las Vegas.

97 MATHEMATICS AND COMPUTING↗

Dynamic Measurements of the Structural Evolution of Material Defects at the Mesoscale

This is a technical report to be published as part of the FY2021 annual overview package. We have designed experiments and developed analytical methods using images from x-ray and electron microscopy in order to quantify the behavior of crystal dislocation defects at their native nanometer-length and micro-length scales. The results of these analyses are used to directly inform theoretical physics models and guide interpretation of dark field x-ray microscopy (DFXM) images that offer spatial resolution surpassing the resolution of beamline optics. Additionally, we developed new analytical methods to automate the alignment of optics hardware used in both synchrotron and x-ray free electron laser beamline facilities. The tools and workflows developed for this project are now being deployed as proof-of-concept in reaction history analysis (RHA) for future programmatic integration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modern version of the uncited 1938 experiment that first observed DT fusion

Experiments are described, and results are provided, for the duplication of the first-ever triton-deuterium (colloquially referred to as DT) fusion experiment accidentally performed by A.J. Ruhlig in 1938, but forgotten in the published scientific literature. Here, we find that Ruhlig overestimated the ratio of the triton-deuterium over deuteron-deuterium neutron yields in his secondary reaction (Reaction-in-Flight) experiment compared to modern theoretical calculations and our duplication of his experiment using modern neutron detection methods. Nevertheless, Ruhlig’s observation provided the motivation for the application of DT fusion after World War II and its more recent importance in peaceful energy production at DT fusion facilities around the world. Additionally, the experimental technique used in the present work provides a novel approach for checking on low-energy triton stopping powers in deuterium containing compounds.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dynamic dielectric analysis for nondestructive cure monitoring and process control

Dynamic dielectric analysis (DDA) is an effective in situ NDE method that can monitor the reaction status in thermosets and the phase changes in thermoplastics, including slow reactions occuring late in the cure cycle and recrystallization during annealing. The effects of moisture and resin history on reaction rate can also be determined, as can ionic and dipolar contributions. The ionic mobility parameter is noted to be an excellent monitor of viscosity above the glass transition temperature. The ability of DDA to monitor cure rate variations in a thick section during autoclaving has been demonstrated.

Kranbuehl, D. E.↗

Condensation, Partial Melting and Evaporation Processes Influence the Bulk Compositions of Spinel-Cored Spherules in the CO3.1 Chondrite Miller Range 90019

Here we focus on spinel-cored spherule calcium-aluminum rich inclusions (CAI), dominantly ~75-80 microns in diameter in the CO3.1 chondrite Miller Range 90019, which make up ~ 12 % of the fine-grained CAIs in one thin section. Their mineralogical content ranges from rare grossite- and hibonite-bearing varieties, through perovskite-melilitebearing, to fassaite-bearing and finally anorthitebearing. Non-spherical CAIs have been divided into 4 other groups, defined based on mineralogical abundances. We also characterized a group of AOAs from this sample. No glass has been recognized in any inclusions. Some relatively evolved members (anorthite-, spinel- + fassaite-bearing) among the spherules are found engulfed in AOAs. We characterized the bulk compositions of ~145 CAIs and AOAs in this meteorite, derived from EDS-x-ray mapping of the inclusions. We determined bulk compositions both with and without Wark-Lovering rims (when present), which are largely composed of diopside  forsterite. The balance of the inclusions appear to have not been melted or partially melted, but rather they have textures that indicate they are condensates, often modified by extensive reaction with nebular gases. This presents the opportunity to examine effects on the bulk compositions of spherules resulting potentially from melting plus evaporation. Other aspects of this suite of refractory inclusions have been discussed in these abstracts. Oxygen isotope variations in one spherule were presented in [4]. The latter study showed a complex history of reaction with nebular gases possessing a variety of Oisotope compositions. Additional O isotopic studies of inclusions in this work are included in Mane et al.

Ross, D. K.↗

Gas scintillation mitigation in gas Cherenkov detectors for inertial confinement fusion (invited)

Gas Cherenkov detectors provide a time resolved measurement of the fusion burn in inertial confinement fusion experiments. The fusion rate delivers critical benchmark figures, such as burn width and bang time. Recent detector improvements pushed temporal resolution to 10 ps to make burn width measurements on igniting targets possible. First high temporal resolution measurements using CO 2 gas fills had a background signal with a long decay length (tail), which was caused by gas scintillation. This gas scintillation limits the ability of the detector to resolve short burn width and high frequency features in the fusion rate measurements. A thorough investigation of the cause of the tail and mitigation options for gas scintillation is presented here. As a near-term resolution, neon gas is being used to extract fusion burn histories. Paths forward for the next generation of gas Cherenkov detectors are identified including the usage of oxygen as a Cherenkov medium.

47 OTHER INSTRUMENTATION↗