Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman thermometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

High-energy, low-jitter, narrowband ps probe laser for kHz-rate fs/ps coherent anti-Stokes Raman scattering

Hybrid fs/ps coherent anti-Stokes Raman scattering (CARS) thermometry often utilizes ps probe pulses derived from pulse shaping or spectrally filtering the primary laser source or by synchronization with a low repetition rate external laser. This results in limited energy, spectral resolution, and/or repetition rate of the ps probe. In this work, a master-oscillator power-amplifier (MOPA) laser was synchronized to the oscillator of a Ti:sapphire regenerative amplifier to achieve high-energy (600 µJ), narrowband (58 ps) probe pulses at kHz repetition rates. Furthermore, temporal filtering allows the pulse characteristics to be adjusted for each application. At 25 Torr, relevant to high-speed flows, the kHz-rate MOPA system generated signal-to-noise ratios 3× higher in nitrogen and had improved precision relative to a 10 ps probe derived from spectral filtering and the power-amplifier. The MOPA system also enabled single-shot ro-vibrational hybrid fs/ps CARS thermometry in 650 K heated air.

47 OTHER INSTRUMENTATION↗

CO 2 chirped-probe-pulse femtosecond CARS thermometry

The application of CO 2 chirped-probe-pulse (CPP) fs coherent anti-Stokes Raman scattering (CARS) for flame thermometry is discussed. A phenomenological model for CO 2 /O 2 CPP fs CARS was developed, and the simulations showed the potential for CO 2 temperature measurements free of interferences from O 2 and with no contribution from the nonresonant background by using a long-time delay for the chirped probe pulse. The accuracy and precision for CO 2 CPP fs CARS thermometry is compared with N 2 CPP fs CARS thermometry for temperatures between 295 K and 1420 K. The measurement accuracy for the CO 2 measurements is comparable with that for the N 2 measurements, while the precision for the CO 2 temperature measurements is significantly better at lower temperatures. In conclusion, we also demonstrate that accurate flame thermometry using a single set of laser parameters can be achieved using the delayed CPP approach.

42 ENGINEERING↗

Numerical study of pure rotational fs/ps CARS coherence beating at high pressure and for multi-species rotation-vibration non-equilibrium thermometry

Coherent anti-Stokes Raman scattering (CARS) has long been the gold standard for non-intrusively measuring gas temperature in reacting flows such as flames and plasmas. Recently, the development of ultrafast hybrid fs/ps CARS has enabled the exploitation of coherence beating between neighboring spectral lines to simultaneously measure rotational and vibrational temperatures from a single pure rotational spectrum. However, the influence of non-Boltzmann vibrational state distributions and limitations due to collisional dephasing at pressures greater than 1 atm remains unclear. In this work, we use spectral simulations to investigate the effects of non-Boltzmann vibrational state distributions and the applicability of coherence beating at pressures up to 10 atm. We show that short probe pulses can be leveraged to quantify non-Boltzmann vibrational state distributions of N2. Furthermore, we demonstrate that fs/ps CARS coherence beating can simultaneously provide sensitive measurements of rotational and vibrational temperatures of both O2 and N2 in air. A sensitivity analysis was conducted to qualitatively explain the accuracy and precision comparisons between probe delays.

Chen, Timothy Y. (ORCID:0000000330269767)↗

Nitrogen thermometry in an inductively coupled plasma torch using broadband nanosecond coherent anti-Stokes Raman scattering

The development of atmospheric hypersonic flight and re-entry capabilities requires the characterization of the thermo-chemical state of representative test environments. This study demonstrates the usage of multiplex nanosecond N 2 coherent anti-Stokes Raman scattering (CARS) to measure temperatures in an atmospheric, high-temperature (>6000K), air plasma plume, generated by an inductively coupled plasma torch. These are some of the highest temperatures ever accessed via gas-phase CARS, to our knowledge. Temperatures of N 2 in the equilibrium plasma plume are determined via theoretical fits to measured CARS spectra. We discuss the practical implementation of CARS at very high temperatures, including the scaling of the N 2 CARS signal strength from 300 to 6700 K, where the expected peak signal from the high-temperature plasma torch gases is two orders of magnitude less than commonly encountered in combustion environments. An intensified CCD camera enables single-laser-shot detection at temperatures as high as 6200 K, by increasing sensitivity and providing a time gate against intense background luminosity. We also discuss the impacts of unwanted two-beam CARS contributions from outside the nominal three-beam measurement volume. We present mean axial and radial temperature profiles, as well as time-series data derived from both single-laser-shot and accumulated CARS spectra. The single-laser-shot precision is 1.7%–2.6% at temperatures of 3500 to 6200 K. The presented results pave the way for the use of CARS at very high temperatures and the measurement of spatially resolved interface processes in high-enthalpy flows.

Fries, Dan (ORCID:0000000229513294)↗

Time-domain modelling and thermometry of the CH 4 v 1 Q-branch using hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering

Here, we present time-domain measurements and modelling of the CH 4 v 1 vibrational Q-branch, as well as simultaneous temperature acquisition from the CH 4 and N 2 vibrational Q-branches using broadband hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS). Accurate measurements with fs/ps CARS require knowledge of the time-domain response of the probed molecule at different temperatures and pressures. In this work, a fs/ps CARS model was developed for theCH 4 v 1 Q-branch and validated using time-resolved probe delay scans at pressures between 70 and 600 Torr and temperatures between 295 and 1000 K. A simplified modified exponential energy gap model was used to determine the linewidths of the Raman transitions within the Q-branch. Total Q-branch linewidths for the entire explored parameter space were also determined from the probe delay scans. This enabled quantitative measurements of CH 4 with fs/ps CARS as well as the temperature through the hot bands of the CH 4 v 1 Q-branch. With a broadband fs laser pulse in a two-beam phase matching scheme, the N 2 Q-branch and CH 4 v 1 Q-branch were simultaneously measured in a heated cell, and the temperatures from each molecule's spectra was evaluated. Here, the fitted temperatures corresponded well with differences ranging from 4 to 17%. It was also shown that exchanging 90% of CH 4 for N 2 or Ar at 295 K and 500 Torr did not significantly impact the normalized time-domain signal prior to a 100 picosecond probe delay. Spatially resolved one-dimensional (1-D) thermometry using the CH 4 Q-branch was also demonstrated with an imaged spatial resolution of 40 µm. With the developed model, 1-D quantitative measurements of CH 4 concentration and temperature can be measured with time resolution of tens of picoseconds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas detection sensitivity of hybrid fs/ps and fs/ns CARS

Coherent anti-Stokes Raman scattering (CARS) is commonly used for thermometry and concentration measurement of major species. The quadratic scaling of CARS signal with number density has limited the use of CARS for detection of minor species, where more sensitive approaches may be more attractive. However, significant advancements in ultrafast CARS approaches have been made over the past two decades, including the development of hybrid CARS demonstrated to yield greatly increased excitation efficiencies. Yet, detailed detection limits of hybrid CARS have not been well established. In this Letter, detection limits for N 2 , H 2 , CO, and C 2 H 4 by point-wise hybrid femtosecond (fs)/picosecond (ps) CARS are determined to be of the order of 10 15 molecules/cm 3 . Here, the possible benefit of fs/nanosecond (ns) hybrid CARS is also discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

A comparison of Raman and pyrometry dynamic temperature measurements of shocked cyclohexane

Optical pyrometry is a well-developed, broadly applicable method to determine temperature in dynamic compression experiments. However, it measures radiation from only the skin depth of the radiant material, is highly susceptible to spurious backgrounds, and requires an often-unmeasurable free parameter—the sample dynamic emissivity. Raman spectroscopy offers a method to determine temperature directly from fundamental theory, but it is practically limited in applications to a small subset of shock experiments. In this work, we describe an experiment allowing simultaneous application of Raman and pyrometric temperature techniques to benchmark a specific instance of pyrometry. We attempted both measurements on multiple experiments and compare the successful temperature results between the separate but highly repeatable shots. Here, we find that dynamic shock temperatures inferred from Raman spectroscopy and pyrometry generally agree within the uncertainties of each measurement, although those uncertainties are larger than typical for a specially designed pyrometry experiment on a shocked metal sample.

74 ATOMIC AND MOLECULAR PHYSICS↗

An Optothermal Raman Model Accounting for Convection, Radiation, and Substrate Effects for Evaluation of the Thermal Conductivity of Two‐Dimensional Coatings

Thermal conductivity of two‐dimensional (2D) materials is important to characterize as this will govern thermal transport physics in the various thermal and energy applications benefitting from the unique properties of these materials. Here, analytical and numerical techniques are presented to determine the thermal conductivity and interfacial conductance of a 2D material coating using confocal micro‐Raman spectroscopy as a noncontact diagnostic. While several methods have been proposed for calculating the values of thermal conductivity, interfacial conductance, and spatial temperature profile, these models often do not consider effects of radiation, convection, and substrate resistance on the temperature and heat flux profiles. We present a model to calculate the thermal conductivity and interfacial conductance which accounts for convection, radiation, and substrate effects to characterize a variety of 2D material coatings, which is demonstrated using large area graphene transferred onto copper and nickel substrates. Convection and radiation effects are found to have a negligible effect on the temperature profile of supported coatings, while the substrate effects have a considerable effect and therefore impact the quantification of thermal conductivity and interfacial conductance in addition to limiting the spatial resolution of the technique. These findings will allow for more accurate and reproducible extraction of the thermal conductivity of graphene and other 2D material coatings when employing noncontact optothermal Raman spectroscopy methods.

2D coatings↗

High-Speed Diagnostic and Simulation Capabilities for Reacting Hypersonic Reentry Flows (LDRD Final Report)

High-enthalpy hypersonic flight represents an application space of significant concern within the current national-security landscape. The hypersonic environment is characterized by high-speed compressible fluid mechanics and complex reacting flow physics, which may present both thermal and chemical nonequilibrium effects. We report on the results of a three-year LDRD effort, funded by the Engineering Sciences Research Foundation (ESRF) investment area, which has been focused on the development and deployment of new high-speed thermochemical diagnostics capabilities for measurements in the high-enthalpy hypersonic environment posed by Sandia's free-piston shock tunnel. The project has additionally sponsored model development efforts, which have added thermal nonequilibrium modeling capabilities to Sandia codes for subsequent design of many of our shock-tunnel experiments. We have cultivated high-speed, chemically specific, laser-diagnostic approaches that are uniquely co-located with Sandia's high-enthalpy hypersonic test facilities. These tools include picosecond and nanosecond coherent anti-Stokes Raman scattering at 100-kHz rates for time-resolved thermometry, including thermal nonequilibrium conditions, and 100-kHz planar laser-induced fluorescence of nitric oxide for chemically specific imaging and velocimetry. Key results from this LDRD project have been documented in a number of journal submissions and conference proceedings, which are cited here. The body of this report is, therefore, concise and summarizes the key results of the project. The reader is directed toward these reference materials and appendices for more detailed discussions of the project results and findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature Measurements in Hypersonic Wind Tunnels via Femtosecond Coherent Anti-Stokes Raman Scattering

A femtosecond coherent anti-Stokes Raman scattering (fs CARS) instrument is developed to perform gas-phase thermometry in cold-flow hypersonic wind tunnels. Measurements are reported for Mach 8 and 14 pure-nitrogen flows. The fs CARS instrument includes a 100 fs pump/Stokes pulse and a spectrally narrow probe pulse from a second harmonic bandwidth compressor. Important experimental considerations such as limits on the pump/Stokes pulse energy are discussed. The fs CARS focusing and collimating optics are mounted on a two-axis translation stage system to scan the measurement location during a 30 second wind tunnel run. Single-laser-shot rotational CARS spectra are recorded at the laser repetition rate of 1 kHz in the wind tunnel freestream and near simple cone models. Spectral fitting is used to determine quantitative gas temperatures. Freestream temperatures at Mach 8 and 14 spanned ranges of 40–75 and 35–50 K, respectively, depending on tunnel operating conditions. Temperature variations across the central 100 mm span of the wind tunnel were quantified. Measured temperature jumps across conical bow shocks from various models varied by less than 1% from predicted values. Hypersonic boundary layer measurements were demonstrated. In conclusion, these measurements illustrate the utility and robustness of this instrument for the study of complex fluid flow phenomena in challenging ground test facilities.

Aerodynamics↗

Simultaneous single-shot rotation–vibration non-equilibrium thermometry using pure rotational fs/ps CARS coherence beating

Here, we report the development of a simple and sensitive two-beam hybrid femtosecond/picosecond pure rotational coherent anti-Stokes Raman scattering (fs/ps CARS) method to simultaneously measure the rotational and vibrational temperatures of diatomic molecules. Rotation–vibration non-equilibrium plays a key role in the chemistry and thermalization in low-temperature plasmas as well as thermal loading of hypersonic vehicles. This approach uses time-domain interferences between ground state and vibrationally excited N 2 molecules to intentionally induce coherence beating that leads to apparent non-Boltzmann distributions in the pure rotational spectra. These distortions enable simultaneous inference of both the rotational and vibrational temperatures. Coherence beating effects were observed in single-shot fs/ps CARS measurements of a 75 Torr N 2 DC glow discharge and were successfully modeled for rotational and vibrational temperature extraction. We show that this method can be more sensitive than a pure rotational fs/ps CARS approach using a spectrally narrow probe pulse. Lastly, we experimentally measured the beat frequencies via Fourier transform of the time-domain response and obtained excellent agreement with the model.

42 ENGINEERING↗

Hybrid time–frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

We demonstrate a hybrid time–frequency spectroscopic method for simultaneous temperature/pressure measurements in nonreacting compressible flows with known gas composition. Hybrid femtosecond–picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an ∼ <#comment/> 5 -mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay ( τ <#comment/> 1 = 0 p s ) and pressure from spectra obtained at probe delays of τ <#comment/> 2 = 150 − <#comment/> 1000 p s , where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded air jet permits evaluation of this hybrid time–frequency domain approach for temperature and pressure measurements across a wide range of low-temperature–low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approaching 1%−2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four ( τ <#comment/> 2 / τ <#comment/> R > <#comment/> 4 ). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapolated high-temperature Q -branch linewidths are presented. Considering all measurements with τ <#comment/> 2 / τ <#comment/> R ≥ <#comment/> 4.0 , measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representing a combination of instrument noise and fluid fluctuations of 5.0%.

Retter, Jonathan E.↗

1-D imaging of rotation-vibration non-equilibrium from pure rotational ultrafast coherent anti-Stokes Raman scattering

We present one-dimensional (1-D) imaging of rotation-vibration non-equilibrium measured by two-beam pure rotational hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS). Simultaneous measurements of the spatial distribution of molecular rotation-vibration non-equilibrium are critical for understanding molecular energy transfer in low temperature plasmas and hypersonic flows. However, non-equilibrium CARS thermometry until now was limited to point measurements. The red shift of rotational energy levels by vibrational excitation was used to determine the rotational and vibrational temperatures from 1-D images of the pure rotational spectrum. Vibrational temperatures up to 5500 K were detected in a CH4/N2 nanosecond-pulsed pin-to-pin plasma within 2 mm near the cathode. As a result, this approach enables study of non-equilibrium systems with 40 µm spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elastic thermobarometry on metapelites across the crustal section of the Famatinian Arc, Argentina

We applied elastic thermobarometry on garnet-bearing migmatites along two transects through the crustal section at Sierra Valle Fértil-La Huerta, Argentina. We performed quartz-in-garnet barometry and zircon-in-garnet thermometry on metapelites from different paleo-depths across the crustal section. Our work recovers entrapment pressures ranging from 240 to 1330 MPa and entrapment temperatures between 691 and 1574 °C. The entrapment conditions are broadly consistent with anticipated pressures and temperatures along the crustal section derived previously using conventional, thermodynamic thermobarometers. The quartz-in-garnet barometer reproduces those conventionally established entrapment conditions when samples only experienced conditions within the alpha-quartz stability field. Raman-derived pressures for samples that experienced beta-quartz reference conditions are commonly much higher than those established by conventional barometry. Samples that preserve compressive (positive) residual pressures best reproduce reference entrapment pressures. Entrapment temperatures show high variability and overestimation of temperature conditions compared to conventional results. These results indicate elastic thermobarometry over- or under-estimates crystallization conditions in rocks crystallized at high temperatures, as is common in the Famatinian Arc deep-crust. We suggest that modeling quartz behavior across the alpha–beta transition may present challenges, as does shape maturation, viscous deformation, and radiation damage in zircon.

58 GEOSCIENCES↗

Enhanced upconversion and photoconductive nanocomposites of lanthanide-doped nanoparticles functionalized with low-vibrational-energy inorganic ligands

Upconverting nanoparticles (UCNPs) convert near-infrared (IR) light into higher-energy visible light, allowing them to be used in applications such as biological imaging, nano-thermometry, and photodetection. It is well known that the upconversion luminescent efficiency of UCNPs can be enhanced by using a host material with low phonon energies, but the use of low-vibrational-energy inorganic ligands and non-epitaxial shells has been relatively underexplored. Here, we investigate the functionalization of lanthanide-doped NaYF4 UCNPs with low-vibrational-energy Sn2S64- ligands. Raman spectroscopy and elemental mapping are employed to confirm the binding of Sn2S64- ligands to UCNPs. This binding enhances upconversion efficiencies up to a factor of 16, consistent with an increase in the luminescent lifetimes of the lanthanide ions. Annealing Sn2S64--capped UCNPs results in the formation of a nanocomposite comprised of UCNPs embedded within an interconnected matrix of SnS2, enabling each UCNP to be electrically accessible through the semiconducting SnS2 matrix. This facilitates the integration of UCNPs into electronic devices, which we demonstrate through the fabrication of a UCNP-SnS2 photodetector that detects UV and near-IR light. Our findings show the promise of using inorganic capping agents to enhance the properties of UCNPs while facilitating their integration into optoelectronic devices.

Pan, Jia-Ahn↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of picosecond coherent anti-Stokes Raman spectra for gas-phase diagnostics

We present a hybrid frequency- and time-domain solution, applicable to the case of picosecond coherent anti-Stokes Raman scattering (CARS), for gas-phase diagnostics. A solution has been derived based on both physical arguments and four-wave mixing equations for picosecond CARS, with pulse durations that are comparable to the dephasing time scale for gas-phase Raman coherence—a regime where commonly employed solutions for impulsive (femtosecond) or cw (nanosecond) pump/Stokes forcing are not strictly valid. We present the ps-CARS spectrum in the form of incoherent sums of CARS intensity spectra, calculated from the fundamental solution for impulsive pump/Stokes Raman preparation. The solution was examined for temperatures from 1000–3000 K, for four plausible experimental configurations, with laser pulse durations of 50–150 ps, and probe pulse delays from −20 to 240 ps. Approximations based on cw and impulsive pump/Stokes preparation to fit picosecond CARS spectra at atmospheric pressure were examined and the relative thermometric accuracy and computational cost of these approximations were quantified for the case of a zero nonresonant CARS contribution, and a nonresonant susceptibility equal to 10% of the Raman-resonant value at the N 2 bandhead. The nanosecond CARS approximation can result in large fitting errors when the probe pulse time delay is less than the probe pulse duration. Errors as large as 10–20% are observed in the fit temperatures for a zero picosecond probe pulse delay, when the nonresonant background is neglected, largely due to an inability of the time-independent cw model to capture transient frequency spread dephasing effects at the Q -branch bandhead. The inclusion of a nonresonant background results in 40–60% thermometry errors with a nanosecond model at a zero-probe delay. Time-dependent impulsive calculations used for femtosecond CARS better approximate the structure of the N 2 bandhead, reducing temperature fitting errors to 5–10% at a short probe pulse delay. The impulsive approximation results in errors up to 10% at intermediate probe pulse delays, where the coherence of the pump and probe pulses leads to multiple terms in the picosecond CARS solution. Both approximations improve as the probe pulse delay exceeds the probe duration. The nanosecond approximation results in a 2–3% error, while the impulsive model results in differences of less than 1% in some cases. Fits to experimental data obtained using short, ∼60ps pulses at a zero probe time delay and longer 100 ps pulses at a substantial 200 ps delay are presented with accuracies of 1–3% in the fit temperature.

Kearney, Sean P.↗