Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radio frequency techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

MULTI-TECHNIQUE CHARACTERIZATION OF SUPERCONDUCTING MATERIALS FOR PARTICLE ACCELERATOR APPLICATIONS

We investigated the performance limitations of superconducting radio-frequency (SRF) cavities and materials using multiple experimental techniques. In particular, this study focuses on understanding the surface properties of nitrogen-doped Nb cavities and super?conducting thin films with higher Tc such as Nb3Sn. The main goal of this work is to use different techniques to better understand each aspect of the complex loss mechanism in superconductors to further improve the already highly efficient SRF cavities. Nitrogen doping applied to a Nb SRF cavity significantly improves the quality factor Q0 compared to a conventional Nb cavity, at an expense of reduced maximum accelerating gradient. The early quench mechanism was analyzed by using temperature maps before and during the quenching. The temperature maps revealed insignificant heating before the quench, and we concluded that nitrogen doping reduces critical magnetic fields in local regions, leading to premature quenching. To understand the origin of the increasing Q0 with the rf field, the density of states (DOS) of cold spots from nitrogen-doped and standard cavities were measured and analyzed using scanning tunneling microscopy. The results suggested that nitrogen doping reduces the spatial inhomogeneity of superconducting properties and shrinks the metallic suboxide layers, which tunes the DOS in such a way as to produce the field-induced reduction in the surface resistance. To characterize SRF thin films, an experimental setup for measuring a coplanar waveguide (CPW) resonator was developed and tested. A surface impedance measurement of the Nb film showed good agreement with the BCS calculation. The preliminary results from measurements of Nb3Sn and NbTiN films are also presented here. The nonlinear Meissner effect was investigated in Nb3Sn film CPW resonators by mea?suring the resonant frequency as a function of a parallel magnetic field. Contrary to a conventional quadratic dependence of the penetration depth ?(B) on the applied magnetic field B, as expected in s-wave superconductors, nearly a linear increase of ?(B) with B was observed. It was concluded that this behavior of ?(B) is due to weakly linked grain bound?aries on the polycrystalline Nb3Sn films, which can mimic the NLME expected in a clean d-wave superconductor.

Makita, Junki↗

Precision gyroscope from the helicity of light

We describe a gyroscope that measures rotation based on the effects of the rotation on the polarization of light. Rotation induces a differential phase shift in the propagation of left- and right-circularly polarized light and this phase shift can be measured in suitably designed interferometric setups. The signal in this setup is independent of the frequency of light, unlike various sources of noise such as vibrations, which cause phase shifts that depend on the frequency. Such vibrations are the practical limit on the sensitivity of conventional Sagnac-style optical interferometers that are typically used as gyroscopes. In the proposed setup, one can potentially mitigate this source of noise by simultaneously using two (or more) sources of light that have different frequencies. The signal in this setup scales with the total storage time of the light. Due to its frequency independence, it is thus most optimal to measure the signal using superconducting radio-frequency systems where the high finesse of the available cavities enables considerably longer storage times than is possible in an optical setup.

47 OTHER INSTRUMENTATION↗

Information-Guided Dynamic Nuclear Polarization

A spin ensemble in thermal equilibrium continuously undergoes random fluctuations analogous to those observed in Brownian motion, a process known as spin noise. Here, we investigate the dynamics of a system comprising a spin-1 paramagnetic center and a hyperfine-coupled spin-1/2 nucleus in the vicinity of a level crossing. We theoretically show that nuclear spins polarize efficiently under the combined action of thermal fluctuations and a closed-loop feedback protocol. The latter articulates periodic observations of the electronic magnetization and radio-frequency pulses connecting hybrid states with opposite nuclear spin alignment. Since nuclear polarization emerges from electronic spin fluctuations, not spin order, this microwave-free technique generically benefits from warmer, not colder, operation temperatures. Furthermore, because the spin dynamics at play near a level crossing is rather insensitive to the absolute value of the magnetic field, our work promises opportunities for high-field dynamic nuclear polarization, which is difficult to attain through present methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resonance in radio frequency sheath admittance and enhanced impurity emission near the ion cyclotron frequency

Ion cyclotron resonance heating (ICRH) is of considerable interest among all auxiliary heating techniques, because it transfers power directly to ions, targets the high-density core, and involves the cheapest radio-frequency (RF) components. During ICRH operation, RF sheaths form on the ICRH antenna itself, nearby hardware, and far-field surfaces. These sheaths are associated with large hot-spot formation and impurity emissions. This work presents high-resolution numerical modelling of RF sheaths in nuclear fusion scenarios using hPIC2, a Debye-scale particle-in-cell code. The modelling reveals a new RF sheath phenomenon which occurs when the RF is resonant with a species ion cyclotron frequency or harmonic in an oblique magnetic field. This resonance of the RF sheath causes modifications of the energy-angle distributions of the ions impacting on the walls, with consequent increase in wall impurity emission. Due to the 1/ R scaling of the magnetic field in a tokamak, such cases are possible on divertor or vacuum chamber surfaces, depending on the geometry of the tokamak and the RF heating scenario. A simple physics interpretation using a driven damped harmonic oscillator is proposed, where the ion sheath transit time plays the role of damping the RF sheath admittance. Critically, the resonance leads to increased ion heat flux at the wall as well as increased physical sputtering, despite a lack of increase in RF rectified sheath potential.

ICRH antenna↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modulation of intensity emerging from zero effort (MIEZE) with extended Fourier time at large scattering angle

Modulation of Intensity Emerging from Zero Effort (MIEZE) is a neutron resonant spin echo technique that allows one to measure time correlation scattering functions in materials by implementing radio-frequency (RF) intensity modulation at the sample and the detector. The technique avoids neutron spin manipulation between the sample and the detector and, thus, could find applications in cases where the sample depolarizes the neutron beam. However, the finite sample size creates a variance in the path length between the locations where scattering and detection happen, which limits the contrast in intensity modulation that one can detect, in particular, toward long correlation times or large scattering angles. We propose a modification to the MIEZE setup that will enable one to extend those detection limits to longer times and larger angles. Furthermore, we use Monte Carlo simulations of a neutron scattering beamline to show that by tilting the RF flippers in the primary spectrometer with respect to the beam direction, one can shape the wave front of the intensity modulation at the sample to compensate for the path variance from the sample and the detector. The simulation results indicate that this change enables one to operate a MIEZE instrument at much increased RF frequencies, thus improving the effective energy resolution of the technique. For the MIEZE instrument simulated, it shows that for an incident beam with the maximum divergence of 0.33°, the maximum Fourier time can be increased by a factor of 3.

47 OTHER INSTRUMENTATION↗

Construction of a New MgB 2 Coating System for 1.3-GHz Superconducting RF Cavities at LANL

After many years of evaluating MgB 2 films prepared with various techniques for the application to superconducting radio-frequency (SRF) cavities, we have decided to build a system to coat full-size 1.3-GHz elliptical cavities. This paper describes the design and construction of the system. Additionally, we briefly describe experimental results with a small system and first tests with the new large system. In conclusion, we were able to obtain superconducting samples with a T c of up to 38 K with the small system, but we have not been able to get any superconducting samples with the new system yet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Unlocking the potential of DNA-based tagging: current market solutions and expanding horizons

The commercialization of DNA tagging is a growing trend that demonstrates the increasing practicality of this novel approach. This interdisciplinary technology is based on the distinctive characteristics of DNA as a molecule that can remain stable in varying environmental conditions and store data following appropriate preparation. Moreover, newly developed technologies could simplify DNA synthesis and the encoding of data within DNA. The implementation of DNA tagging presents distinctive benefits in comparison to conventional labelling techniques, including universal product code (UPC) barcoding, radio-frequency identification (RFID), quick response (QR) codes, and Bluetooth technologies, by surmounting the limitations encountered by these systems. The discourse pertains to extant DNA-tagging mechanisms along with prospective implementations in a wide range of domains, including but not limited to art, the metaverse, forensics, wildlife monitoring, and the military. The potential of DNA labelling in various contexts underscores the importance of continued research and development in this rapidly evolving field.

59 BASIC BIOLOGICAL SCIENCES↗

3-D Printed Electro-Magnetic Objects for THz Communications

Advanced materials and manufacturing techniques will pave the path towards high quality electro-magnetic circuits that operate up through THz and into optics regime. Digital additive manufacturing (AM) techniques offer game-changing potential for large scale manufacturing of Radio-frequency (RF) circuits and system in custom 2D/3D geometries. The technical collaboration will explore the design flexibility and product customization capabilities of additive manufacturing techniques to process magnetic materials in custom 3D geometries with tailored dielectric properties and frequency response characteristics. Transformation of an RF circuit design idea into a 3D printed system using additive manufacturing techniques will bring together the elements of advanced materials, additive integration, and low-cost manufacturing for future advanced wireless communication systems.

36 MATERIALS SCIENCE↗

Towards Fast and Accurate Predictions of Radio Frequency Power Deposition and Current Profile via Data-driven Modeling

Three machine learning techniques (multilayer perceptron, random forest, and Gaussian process) provide fast surrogate models for lower hybrid current drive (LHCD) simulations. A single GENRAY/CQL3D simulation without radial diffusion of fast electrons requires several minutes of wall-clock time to complete, which is acceptable for many purposes, but too slow for integrated modeling and real-time control applications. The machine learning models use a database of 16,000+ GENRAY/CQL3D simulations for training, validation, and testing. Latin hypercube sampling methods ensure that the database covers the range of 9 input parameters ($n_{e0}$, $T_{e0}$, $I_p$, $B_t$, $R_0$, $n_{||}$, $Z_{eff}$, $V_{loop}$, $P_{LHCD}$) with sufficient density in all regions of parameter space. The surrogate models reduce the inference time from minutes to ~ms with high accuracy across the input parameter space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commissioning of SRF Cavity Analyzer System

Research and development in Superconducting Radio Frequency (SRF) cavities manufacturing, surface treatment, preparation, and doping techniques for the improvement of cavities performance necessitate reliable cavities’ intrinsic quality factor measurement with accurate and repeatable results. Fermilab Vertical Test Stand facility (VTS) performs ~270 cavities tests per year, including R&D cavities as well as production cavities at each step of their preparation for the placement in accelerator’s cryomodules. Current Fermilab VTS testing system is based on the scalar approach of power measurement, which neglects potential error factors of the RF networks with distributed parameters, hence the assessed measurement errors of such a system might be slightly underestimated. Alternative approach, utilizing a vector measurement (amplitude and phase) of RF signals in the setup with a cavity as a device under test, promises an enhanced accuracy and results traceability. New cavity an alyser system based on this approach (Vector VTS) was developed by D. Frolov et al. and currently undergoes a commissioning process. Basic underlying principles of the system will be presented with the methods of quality factor extraction from S-parameters measurement of multiport cavities and brief error analysis will be discussed. The system architecture will be shown with main components parameters and ensuing testing capabilities. Multiple tests results will be discussed with a cross-check comparison of the results obtained with a conventional testing method. System advantages such as automated calibration process and additional features as a built- in microphonics measurement capability will be presented.

Netepenko, A.↗

High laser fluence ITO coatings utilizing a Fabry-Perot thin film filter to reduce effective absorption

Laser-induced damage threshold of transparent conductors, such as Indium Tin Oxide (ITO), is limited by their high optical absorption due to free carriers. However, the effective absorption of a transparent conductor thin film can be reduced by an order of magnitude, without changing the electrical characteristics of the film, when placed in a low electric field section of a multilayer coating. A Fabry-Perot thin film interference filter has both high transmittance and low electric field positions, so it is an ideal thin film structure for this application. Although Fabry-Perot interference filters are not known as particularly high laser-induced damage resistant coatings due to their resonant characteristics, a laser-induced damage threshold (LIDT) improvement of up to 8× was observed with this technique compared to single layer ITO coatings fabricated using either radio frequency magnetron sputtering or electron-beam deposition. Additionally, an approximately 4× LIDT improvement for a Fabry-Perot interference filter has been observed by the addition of ITO into the multilayer structure.

47 OTHER INSTRUMENTATION↗

Finite element modeling of electropolishing of radio frequency dipole Nb crab cavity in hydrofluoric-sulfuric acid electrolyte

The superior performance of niobium superconducting radio frequency (SRF) cavities is achieved through meticulous surface treatment, notably via chemical electropolishing, ensuring exceptionally smooth surfaces. While this technique has been extensively employed for cylindrically symmetric structures, addressing more intricate geometries poses significant challenges in achieving uniform polishing and controlled material removal, especially when moving away from retractable cathodes. This presents a multifaceted electrochemical, thermal, and fluid dynamics conundrum. A prime example is the 197 MHz radio frequency dipole (RFD) crabbing cavity proposed for the Electron Ion Collider (EIC) project, exemplifying such complex structures. Our groundbreaking work integrates the localized oxide thickness variation, considering its impact on current distribution and Joule heating, within the framework of multi-physics modeling using the COMSOL® simulation suite. This approach was applied to a comprehensive model of the RFD cavity, allowing us to investigate optimal external cooling water flow conditions necessary for achieving desirable outcomes. In conclusion, this illustrates the increasing utility of such multi-physics codes to greatly aid in designing solutions to challenging processing requirements for increasingly complex accelerator cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-of-flight modulated intensity small-angle neutron scattering measurement of the self-diffusion constant of water

We report that the modulated intensity by zero effort small-angle neutron scattering (MI-SANS) technique is used to measure scattering with a high energy resolution on samples normally ill-suited for neutron resonance spin echo. The self-diffusion constant of water is measured over a q–t range of 0.01–0.2 Å -1 and 70–500 ps. In addition to demonstrating the methodology of using time-of-flight MI-SANS instruments to observe diffusion in liquids, the results support previous measurements on water performed with different methods. This polarized neutron technique simultaneously measures the intermediate scattering function for a wide range of time and length scales. Two radio frequency flippers were used in a spin-echo setup with a 100 kHz frequency difference in order to create a high-resolution time measurement. The results are compared with self-diffusion measurements made by other techniques and the general applicability of MI-SANS at a pulsed source is assessed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High energy electron diffraction instrument with tunable camera length

Ultrafast electron diffraction (UED) stands as a powerful technique for real-time observation of structural dynamics at the atomic level. In recent years, the use of MeV electrons from radio frequency guns has been widely adopted to take advantage of the relativistic suppression of the space charge effects that otherwise limit the temporal resolution of the technique. Nevertheless, there is not a clear choice for the optimal energy for a UED instrument. Scaling to beam energies higher than a few MeV does pose significant technical challenges, mainly related to the inherent increase in diffraction camera length associated with the smaller Bragg angles. In this study, we report a solution by using a compact post-sample magnetic optical system to magnify the diffraction pattern from a crystal Au sample illuminated by an 8.2 MeV electron beam. Our method employs, as one of the lenses of the optical system, a triplet of compact, high field gradients (>500 T/m), small-gap (3.5 mm) Halbach permanent magnet quadrupoles. Shifting the relative position of the quadrupoles, we demonstrate tuning the magnification by more than a factor of two, a 6× improvement in camera length, and reciprocal space resolution better than 0.1 Å –1 in agreement with beam transport simulations.

47 OTHER INSTRUMENTATION↗

Towards fast and accurate predictions of radio frequency power deposition and current profile via data-driven modelling: applications to lower hybrid current drive

Three machine learning techniques (multilayer perceptron, random forest and Gaussian process) provide fast surrogate models for lower hybrid current drive (LHCD) simulations. A single GENRAY/CQL3D simulation without radial diffusion of fast electrons requires several minutes of wall-clock time to complete, which is acceptable for many purposes, but too slow for integrated modelling and real-time control applications. The machine learning models use a database of more than 16 000 GENRAY/CQL3D simulations for training, validation and testing. Latin hypercube sampling methods ensure that the database covers the range of nine input parameters ( $n_{e0}$ , $T_{e0}$ , $I_p$ , $B_t$ , $R_0$ , $n_{\|}$ , $Z_{{\rm eff}}$ , $V_{{\rm loop}}$ and $P_{{\rm LHCD}}$ ) with sufficient density in all regions of parameter space. The surrogate models reduce the inference time from minutes to $\sim$ ms with high accuracy across the input parameter space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Niobium to Titanium Electron Beam Welding for SRF Cavities

Titanium and niobium are the main materials used for the fabrication of Superconducting Radio Frequency (SRF) cavities. These two metals are usually joined , using various welding techniques, using a third material in between. This contribution focuses on the development of an innovative electron beam welding technique capable of producing a strong bond between these two different materials. Several samples are produced and tested to assess the mechanical strength at room and cryogenic temperature as well as the composition of the resulting welded joint. Also, the first units of the Single Spoke Resonator type 2 (SSR2) cavities for the Proton Improvement Plan-II (PIP-II [1]) have been fabricated joining directly various grades of titanium to niobium and results gathered through the fabrication will be reported.

43 PARTICLE ACCELERATORS↗