Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radio frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Complex Signal Kurtosis and Independent Component Analysis for Wideband Radio Frequency Interference Detection

Radio-frequency interference (RFI) has negatively implicated scientific measurements across a wide variation passive remote sensing satellites. This has been observed in the L-band radiometers SMOS, Aquarius and more recently, SMAP [1, 2]. RFI has also been observed at higher frequencies such as K band [3]. Improvements in technology have allowed wider bandwidth digital back ends for passive microwave radiometry. A complex signal kurtosis radio frequency interference detector was developed to help identify corrupted measurements [4]. This work explores the use of ICA (Independent Component Analysis) as a blind source separation technique to pre-process radiometric signals for use with the previously developed real and complex signal kurtosis detectors.

microwave↗

NASA Radio Frequency Spectrum Management Manual

The Radio Frequency (RF) Spectrum Management Manual sets forth procedures and guidelines for the management requirements for controlling the use of radio frequencies by the National Aeronautics and Space Administration. It is applicable to NASA Headquarters and field installations. NASA Management Instruction 1102.3 assigns the authority for management of radio frequencies for the National Aeronautics and Space Administration to the Associate Administrator for Space Operations, NASA Headquarters. This manual is issued in loose-leaf form and will be revised by page changes.

Source record↗

Direct current magnetic Hall probe technique for measurement of field penetration in thin film superconductors for superconducting radio frequency resonators

Superconducting Radio Frequency (SRF) cavities used in particle accelerators are typically formed from or coated with superconducting materials. Currently, high purity niobium is the material of choice for SRF cavities that have been optimized to operate near their theoretical field limits. This brings about the need for significant R & D efforts to develop next generation superconducting materials that could outperform Nb and keep up with the demands of new accelerator facilities. To achieve high quality factors and accelerating gradients, the cavity material should be able to remain in the superconducting Meissner state under a high RF magnetic field without penetration of quantized magnetic vortices through the cavity wall. Therefore, the magnetic field at which vortices penetrate a superconductor is one of the key parameters of merit of SRF cavities. Techniques to measure the onset of magnetic field penetration on thin film samples need to be developed to mitigate the issues with the conventional magnetometry measurements that are strongly influenced by the film orientation and shape and edge effects. In this work, we report the development of an experimental setup to measure the field of full flux penetration through films and multi-layered superconductors. Our system combines a small superconducting solenoid that can generate a magnetic field of up to 500 mT at the sample surface and three Hall probes to detect the full flux penetration through the superconductor. We report this setup can be used to study alternative materials that could potentially outperform niobium, as well as superconductor–insulator–superconductor (SIS) multilayer coatings on niobium.

47 OTHER INSTRUMENTATION↗

Demonstration of sub-GV/m accelerating field in a photoemission electron gun powered by nanosecond 𝑋-band radio-frequency pulses

Radio-frequency (rf) photoemission electron guns operating at higher accelerating gradients offer a pathway to produce brighter electron bunches. Brighter beams are expected to revolutionize many areas of science: they could form the backbone of next-generation compact x-ray free-electron lasers or provide coherent ultrafast quantum electron probes. We report on the experimental demonstration of an rf photoemission electron source supporting an accelerating field close to 400 MV/m at the photocathode surface without major rf breakdown or significant dark current over a 3-week experimental run. This unprecedented gradient was achieved by operating the gun in a new regime with short rf pulses, ~9ns X-band (11.7 GHz). The demonstrated paradigm provides a viable path to form relativistic electron beams with unprecedented brightness.

43 PARTICLE ACCELERATORS↗

The Mariner Mars 1971 radio frequency subsystem

The radio frequency subsystem (RFS) for the Mariner Mars 1971 (MM'71) spacecraft is described. The MM'69 RFS was used as the baseline design for the MM'71 RFS, and the report describes the design changes made to the 1969 RFS for use on MM'71. It also cites various problems encountered during the fabrication and testing of the RFS, as well as the types of tests to which the RFS was subjected. In areas where significant problems were encountered, a detailed description of the problem and its solution is presented. In addition, some recommendations are given for modifications to the RFS and test techniques for future programs.

Hughes, R. S.↗

Magnetic field mapping of superconducting radio frequency cavities

Superconducting radio frequency (SRF) cavities are the fundamental building blocks of modern particle accelerators. Niobium is the material of choice to build such cavities. These cavities require a cryogenic cool-down to ~2 ? 4 K for optimum performance minimizing RF losses on the inner cavity surface. However, temperature-independent residual losses in SRF cavities cannot be prevented entirely. One of the major sources of residual losses is trapped magnetic flux. The flux trapping mechanism depends on different factors, such as surface preparations and cool-down conditions. We have developed a diagnostic magnetic field scanning system (MFSS) using Hall probes and anisotropic magneto-resistance sensors to study the spatial distribution of trapped flux in 1.3 GHz single-cell cavities. The first result from this newly commissioned system revealed that the trapped flux on the cavity surface might redistribute with increasing RF power. The MFSS was also able to capture significant magnetic field enhancement at specific cavity locations after a quench.

Parajuli, Ishwari↗

Analysis of a discrete spectrum analyzer for the detection of radio frequency interference

As the radio frequency spectrum becomes increasingly overcrowded, interference with mission-critical DSN operations is rising at an alarming rate. To alleviate this problem the DSN is developing a wideband surveillance system for on-site detection and identification of potential sources of radio frequency interference (RFI), which will complement the existing frequency coordination activities. The RFI monitoring system is based on a wideband, multi-look discrete spectrum analyzer operating on fast Fourier transform principles. An extensive general statistical analysis is presented of such spectrum analyzers and derives threshold detection performance formulas for signals of interest. These results are then applied to the design of the RFI spectrum analyzer under development.

Levitt, B. K.↗

Advanced radio frequency sensing probe

A radio-frequency probe system with a transmitting or receiving element integrated into a cable assembly is disclosed. In some embodiments a preferred configuration may contain one or more sensing elements integrated into the transmitting or receiving element. In another embodiment, the radio frequency probe comprises an antenna body fixed to a coaxial cable, in which the center conductor of the coaxial cable serves as the transmitting or receiving element. A method for monitoring, transmitting, or detecting one or more parameters using a single radio frequency probe is also disclosed.

Sappok, Alexander↗

A high-frequency, low-power resonant radio-frequency neutron spin flipper for high-resolution spectroscopy

Here, we present a resonant-mode, transverse-field, radio-frequency (rf) neutron spin flipper design that uses high-temperature superconducting films to ensure sharp transitions between uniform magnetic field regions. Resonant mode allows for low-power, high-frequency operation but requires strict homogeneity of the magnetic fields inside the device. This design was found to efficiently flip neutrons at 96.6 ± 0.6% at an effective frequency of 4 MHz in bootstrap configuration with a beam size of 2.4 × 2.5 cm 2 and a wavelength of 0.4 nm. The high frequency and efficiency enable this device to perform high-resolution neutron spectroscopy with comparable performance with currently implemented rf flipper designs. The limitation of the maximum frequency was found due to the field homogeneity of the device. We numerically analyze the maximum possible efficiency of this design using a Bloch solver simulation with magnetic fields generated from finite-element simulations. We also discuss future improvements of the efficiency and frequency to the design based on the experimental and simulation results.

47 OTHER INSTRUMENTATION↗

A Self-learning Neural Network Approach for Radio Frequency Interference Detection and Removal in Radio Astronomy

In this work, we present a novel neural network (NN) method for the detection and removal of radio frequency interference (RFI) from the raw digitized signal in the signal processing chain of a typical radio astronomy experiment. The main advantage of our method is that it does not require a training set. Instead, our method relies on the fact that the true signal of interest coming from astronomical sources is thermal and therefore described as a Gaussian random process, which cannot be compressed. We employ a variational encoder/decoder network to find the compressible information in the data stream that can explain the most variance with the fewest degrees of freedom. We demonstrate it on a set of toy problems and stored ring buffers from the Baryon Mapping eXperiment prototype. We find that the RFI subtraction is effective at cleaning simulated time streams: While we find that the power spectra of the RFI-cleaned time streams output by the NN suffer from extra signal consistent with additive noise, we find that it is generally around percent level across the band and sub 10% in contaminated spectral channels even when RFI power is an order of magnitude larger than the signal. We discuss the advantages and limitations of this method and possible implementation in the front end of future radio experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Delay Tolerant, Radio Frequency Identification (RFID )-enabled Sensing

Radio Frequency Identification (RFID) technology offers a completely passive method to transmit fixed data sequences from an RFID tag, which typically doesn’t have its own power supply, to an interrogator. Radio frequency (RF) energy harvested from the interrogator is rectified by the tag and used to charge an integrated circuit (IC). The IC then modulates the received signal with the data stored on the tag and reflects the energy back to the interrogator. RFID has seen great proliferation in terrestrial inventory management applications, and it has recently made the jump to spaceflight applications onboard the International Space Station, augmenting an existing optical bar‐code infrastructure for tracking supplies. A number of advanced automated logistics management (ALM) concepts employing RFID are currently being developed and evaluated, including so‐called “smart” shelves, cubbies, and trash receptacles using low‐power, embeddable RFID interrogators. An infrastructure where both crew members and robotic assistants, such as autonomous free flyers, are similarly equipped with small RFID interrogators seems likely. It therefore behooves us to consider extending this infrastructure beyond ALM to applications such as low power, embedded sensing. Typically, data on an RFID tag can only be written by an RFID interrogator, using interrogator energy. In recent years, however, a few efforts have focused on using that energy to drive data acquisition from the tag IC, allowing the tag to modify its stored data sequence with sensor data before replying to an interrogator. In this way, the tag can act as a completely passive sensing device. One problem exists with this approach, however: the tag cannot gather data when an interrogator is not present. Thus, strictly passive RFID sensing tags cannot gather data at regular intervals, in the manner of a typical wireless sensor network, without careful, and impractical, planning of mobile interrogator movements. To address this shortcoming, we look to a recent advance in RFID technology which allows an external microprocessor to power the tag IC and write directly into its RFID memory using a wired serial interface. In this paradigm, data gathering is driven by a small, on‐board power supply (using batteries or harvested energy), and data transfer is provided passively through the RFID interrogation service. Since communication typically consumes the lion’s share of power in WSNs, such a technique has the potential to enable extremely long‐lived, embedded wireless sensing when used with extremely low‐current microcontrollers. Since the communication channel is only open when an interrogator is present and actively interrogating the RFID sensing tag, transport of periodically‐sampled sensor data presents itself as a delay/disruption‐tolerant networking (DTN) problem. In this paper, we present the design of a DTN‐like overlay on the common EPC Global, Class 1, Generation 2 RFID standard. This overlay allows seamless, guaranteed data transfer using the EPC Global protocol, supporting extremely low‐power, embedded sensing using an infrastructure likely to be already in place for ALM applications. We evaluate a prototype implementation of a complete end‐to‐end system using a robotic RFID interrogation agent, and we present future directions for the development of this sensing technique.

Raymond S. Wagner↗

Methods, Systems and Apparatuses for Radio Frequency Identification

A system for radio frequency identification (RFID) includes an enclosure defining an interior region interior to the enclosure, and a feed for generating an electromagnetic field in the interior region in response to a signal received from an RFID reader via a radio frequency (RF) transmission line and, in response to the electromagnetic field, receiving a signal from an RFID sensor attached to an item in the interior region. The structure of the enclosure may be conductive and may include a metamaterial portion, an electromagnetically absorbing portion, or a wall extending in the interior region. Related apparatuses and methods for performing RFID are provided.

Fink, Patrick W.↗

Methods, Systems and Apparatuses for Radio Frequency Identification

A system for radio frequency identification (RFID) includes an enclosure defining an interior region interior to the enclosure, and a feed for generating an electromagnetic field in the interior region in response to a signal received from an RFID reader via a radio frequency (RF) transmission line and, in response to the electromagnetic field, receiving a signal from an RFID sensor attached to an item in the interior region. The structure of the enclosure may be conductive and may include a metamaterial portion, an electromagnetically absorbing portion, or a wall extending in the interior region. Related apparatuses and methods for performing RFID are provided.

Fink, Patrick W.↗

Methods, Systems and Apparatuses for Radio Frequency Identification

A system for radio frequency identification (RFID) includes an enclosure defining an interior region interior to the enclosure, and a feed for generating an electromagnetic field in the interior region in response to a signal received from an RFID reader via a radio frequency (RF) transmission line and, in response to the electromagnetic field, receiving a signal from an RFID sensor attached to an item in the interior region. The structure of the enclosure may be conductive and may include a metamaterial portion, an electromagnetically absorbing portion, or a wall extending in the interior region. Related apparatuses and methods for performing RFID are provided.

Fink, Patrick W.↗

Similarity law and frequency scaling in low-pressure capacitive radio frequency plasmas

We verify the similarity law (SL) and show a violation of frequency scaling (f-scaling) in low-pressure capacitive radio frequency (rf) plasmas via fully kinetic particle-in-cell simulations. The SL scaling relations for electron density and electron power absorption are first confirmed in similar rf discharges. Based on these results, with only the driving frequency varied, the f-scaling for electron density is also validated, showing almost the same trend as the SL scaling, across most of the frequency regime. However, violations of the f-scaling are observed at lower frequencies, which are found to be relevant to the electron heating mode transition from stochastic to Ohmic heating. Electron kinetic invariance is illustrated for the SL and f-scaling being valid, respectively, whereas the electron kinetic variation is observed when the f-scaling is violated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characteristics of type III exciters derived from low frequency radio observations

Low-frequency radio observations (2.8 MHz to 67 kHz) from the RAE-1 and IMP-6 satellites allow the tracking of type III solar burst exciters out to large distances from the sun (of the order of 1 AU). A study of the interaction processes between the exciter and the interplanetary medium was made using the time-intensity profiles of the radio emission. The change in exciter length with distance from the sun, and the resulting exciter velocity dispersion which can be deduced from this change are investigated. From detailed measurements on 35 simple bursts it is found that the exciter length increases at a faster rate than a constant velocity dispersion would give. The damping of the radio emission is also investigated, and it is concluded that some current theories of the damping mechanism give results which are not consistent with the low-frequency observations.

Evans, L. G.↗

RFID Transponders' Radio Frequency Emissions in Aircraft Communication and Navigation Radio Bands

Radiated emissions in aircraft communication and navigation bands are measured from several active radio frequency identification (RFID) tags. The individual tags are different in design and operations. They may also operate in different frequency bands. The process for measuring the emissions is discussed, and includes tag interrogation, reverberation chamber testing, and instrument settings selection. The measurement results are described and compared against aircraft emission limits. In addition, interference path loss for the cargo bays of passenger aircraft is measured. Cargo bay path loss is more appropriate for RFID tags than passenger cabin path loss. The path loss data are reported for several aircraft radio systems on a Boeing 747 and an Airbus A320.

Nguyen, Truong X.↗

Magnetic field sensors for detection of trapped flux in superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are fundamental building block of modern particle accelerators. They operate at liquid helium temperatures 2-4 K to achieve very high quality factors 1e10-1e11. Trapping of magnetic flux within the superconductor is a significant contribution to the residual RF losses which limit the achievable quality factor. Suitable diagnostic tools are in high demand to understand the mechanisms of flux trapping in technical superconductors and the fundamental components of such diagnostic tool are magnetic field sensors. We have studied the performance of commercially available Hall probes, anisotropic magnetoresistive sensors and flux-gate magnetometers with respect to their sensitivity and capability to detect localized, low magnetic flux amplitudes, of the order of few tens of magnetic flux quantum at liquid helium temperature. Although Hall probes have the lowest magnetic field sensitivity (~96$ nV$/microT at 2 K), their physical dimensions are such that they have the ability to detect the lowest number of trapped vortices among the three type of sensors. Hall probes and anisotropic magnetoresistive sensors have been selected to be used in a setup to map regions of trapped flux on the surface of a single-cell SRF cavity.

47 OTHER INSTRUMENTATION↗