Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Radiation detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Detectable gravitational radiation from stellar collapse

The problem of astrophysical sources of detectable gravitational radiation is considered from the stellar-evolution viewpoint. Calculations are presented which indicate that the final stages of evolution may well be dominated by rapidly rotating, collapsing cores which develop nonaxisymmetric configurations. Such events emit large amounts of gravitational radiation which should be detectable in the near future.

Endal, A. S.

Gamma-ray astrophysics

The experimental development of gamma-ray astronomy and detectors for gamma-ray observations is reviewed together with recent results obtained by the SAS-2, COS-B, and other satellites. Diffuse gamma-ray emission from the galactic plane is discussed, various localized sources are examined, and the primary production processes for celestial gamma-rays are treated in relation to the difficulty involved in detecting this radiation. Several different types of gamma-ray detectors are described in detail, and the production of high-energy gamma-rays by cosmic-ray interactions with interstellar matter is investigated. Observations of gamma-rays from the Crab Nebula and pulsar, the Vela pulsar, Cen A, and other point or localized sources are summarized with observations of nuclear gamma-ray lines during solar flares. Possible interpretations are considered for the diffuse gamma-radiation detected in regions away from the galactic plane.

Fichtel, C. E.

Simulating and Detecting Radiation-Induced Errors for Onboard Machine Learning

Spacecraft processors and memory are subjected to high radiation doses and therefore employ radiation-hardened components. However, these components are orders of magnitude more expensive than typical desktop components, and they lag years behind in terms of speed and size. We have integrated algorithm-based fault tolerance (ABFT) methods into onboard data analysis algorithms to detect radiation-induced errors, which ultimately may permit the use of spacecraft memory that need not be fully hardened, reducing cost and increasing capability at the same time. We have also developed a lightweight software radiation simulator, BITFLIPS, that permits evaluation of error detection strategies in a controlled fashion, including the specification of the radiation rate and selective exposure of individual data structures. Using BITFLIPS, we evaluated our error detection methods when using a support vector machine to analyze data collected by the Mars Odyssey spacecraft. We found ABFT error detection for matrix multiplication is very successful, while error detection for Gaussian kernel computation still has room for improvement.

data analysis

Space Radiation Shielding Studies for Astronaut and Electronic Component Risk Assessment

The dosimetry component of the Center for Radiation Engineering and Science for Space Exploration (CRESSE) will design, develop and characterize the response of a suite of radiation detectors and supporting instrumentation and electronics with three primary goals that will: (1) Use established space radiation detection systems to characterize the primary and secondary radiation fields existing in the experimental test-bed zones during exposures at particle accelerator facilities. (2) Characterize the responses of newly developed space radiation detection systems in the experimental test-bed zones during exposures at particle accelerator facilities, and (3) Provide CRESSE collaborators with detailed dosimetry information in experimental test-bed zones.

Fuchs, Jordan Robert

Airborne infrared astronomy

After a brief review of the general procedures involved in airborne infrared astronomy and of the historical background leading up to this important new technique, sources of infrared radiation, effects of the earth's atmosphere on this incoming radiation, methods of detection of infrared sources, and the development of airborne observatories are described. The discussion is on a lay level; the correlation of heat with infrared emission, the primary role played by CO2 and H2O in the opacity of the atmosphere in the IR above 18 microns, the use of a crystal to electronically detect radiation in the desired spectral region, and the Lear Jet telescope as mounted in a modified C-141 cargo jet are considered.

Caroff, L.

Pulmonary-impedance power spectral analysis: A facile means of detecting radiation-induced gastrointestinal distress and performance decrement in man

Changes in respiratory variance revealed by power spectral analysis of the pulmonary impedance pneumogram can be used to detect and measure stresses directly or indirectly affecting human respiratory function. When gastrointestinal distress occurred during a series of 5 total-body exposures of 30 R at a rate of 1.5 R/min, it was accompanied by typical shifts in pulmonary impedance power spectra. These changes did not occur after protracted exposure of 250 R (30 R daily) at 1.5 R/hr that failed to cause radiation sickness. This system for quantitating respiratory effort can also be used to detect alterations in one's ability to perform under controlled exercise conditions.

Rick, R. C.

Mossbauer spectrometer radiation detector

A Mossbauer spectrometer with high efficiencies in both transmission and backscattering techniques is described. The device contains a sodium iodide crystal for detecting radiation caused by the Mossbauer effect, and two photomultipliers to collect the radiation detected by the crystal. When used in the transmission technique, the sample or scatterer is placed between the incident radiation source and the detector. When used in a backscattering technique, the detector is placed between the incident radiation source and the sample of scatterer such that the incident radiation will pass through a hole in the crystal and strike the sample. Diagrams of the instrument are provided.

Singh, J. J.

Applications in Bioastronautics and Bioinformatics: Early Radiation Cataracts Detected by Noninvasive, Quantitative, and Remote Means

Human exploration of Mars is a key goal in NASA's exploration planning in the next 20 years. Maintaining crew health and good vision is certainly an important aspect of achieving a successful mission. Continuous radiation exposure is a risk factor for radiation-induced cataracts in astronauts because radiation exposure in space travel has the potential of accelerating the aging process (ref. 1). A patented compact device (ref. 2) based on the technique of dynamic light scattering (DLS) was designed for monitoring an astronaut's ocular health during long-duration space travel. This capability of early diagnosis, unmatched by any other clinical technique in use today, may enable prompt initiation of preventive/curative therapy. An Internet web-based system integrating photon correlation data and controlling the hardware to monitor cataract development in vivo at a remote site in real time (teleophthalmology) is currently being developed. The new technology detects cataracts very early (at the molecular level). Cataract studies onboard the International Space Station will be helpful in quantifying any adverse effect of radiation to ocular health. The normal lens in a human eye, situated behind the cornea, is a transparent tissue. It contains 35 wt % protein and 65 wt % water. Aging, disease (e.g., diabetes), smoking, dehydration, malnutrition, and exposure to ultraviolet light and ionizing radiation can cause agglomeration of the lens proteins. Protein aggregation can take place anywhere in the lens, causing lens opacity. The aggregation and opacification could produce nuclear (central portion of the lens) or cortical (peripheral) cataracts. Nuclear and posterior subcapsular (the membrane's capsule surrounds the whole lens) cataracts, being on the visual optical axis of the eye, cause visual impairment that can finally lead to blindness. The lens proteins, in their native state, are small in size. As a cataract develops, this size grows from a few nanometers (transparent) to several micrometers (cloudy). Ansari and Datiles have shown that DLS can detect cataracts at least two to three orders of magnitude earlier noninvasively and quantitatively than the best imaging (Scheimpflug) techniques in clinical use today (ref. 3).

Ansari, Rafat R.

Data processing improvements for the Skylab S-191 EREP spectrometer

The characteristics of the S-191 spectrometer (filter wheel infrared spectrometer) are discussed. Inherent deficiencies in previous spectrometers are described and the techniques for correcting the deficiencies are explained. The radiance errors caused by error in wavelength are identified and the effects on the accuracy of the spectrometer are described. It is stated that the most important source of error in the S-191 spectrometer is off-band radiation in which the detected radiation is far from the wavelength which is expected to be detected by the sensor at that particular time. A numerical analysis of the effects of off-band radiation is developed.

Campbell, C. E.

Radiation sensitive area detection device and method

A radiation sensitive area detection device for use in conjunction with an X ray, ultraviolet or other radiation source is provided which comprises a phosphor containing film which releases a stored diffraction pattern image in response to incoming light or other electromagnetic wave. A light source such as a helium-neon laser, an optical fiber capable of directing light from the laser source onto the phosphor film and also capable of channelling the fluoresced light from the phosphor film to an integrating sphere which directs the light to a signal processing means including a light receiving means such as a photomultiplier tube. The signal processing means allows translation of the fluoresced light in order to detect the original pattern caused by the diffraction of the radiation by the original sample. The optical fiber is retained directly in front of the phosphor screen by a thin metal holder which moves up and down across the phosphor screen and which features a replaceable pinhole which allows easy adjustment of the resolution of the light projected onto the phosphor film. The device produces near real time images with high spatial resolution and without the distortion that accompanies prior art devices employing photomultiplier tubes. A method is also provided for carrying out radiation area detection using the device of the invention.

Carter, Daniel C.

Advancements in medicine from aerospace research

A program designed to find second applications for space technology in the medical field is described. Illustrative examples and clinical test results are included for prosthetic urethral devices, ear oximeter for monitoring leukemia patients, devices for measuring low level CO effects on automobile drivers, radiation dosimeter probe for detecting radiation levels in cancerous areas, and electromyographic muscle trainer.

Wooten, F. T.

The challenge of detecting gravitational radiation is creating a new chapter in quantum electronics: Quantum nondemolition measurements

Future gravitational wave antennas will be approximately 100 kilogram cylinders, whose end-to-end vibrations must be measured so accurately (10 to the -19th power centimeters) that they behave quantum mechanically. Moreover, the vibration amplitude must be measured over and over again without perturbing it (quantum nondemolition measurement). This contrasts with quantum chemistry, quantum optics, or atomic, nuclear, and elementary particle physics where measurements are usually made on an ensemble of identical objects, and care is not given to whether any single object is perturbed or destroyed by the measurement. Electronic techniques required for quantum nondemolition measurements are described as well as the theory underlying them.

Braginsky, V. B.