Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Radiation Source Replacement Workshop

This report summarizes a Radiation Source Replacement Workshop in Houston Texas on October 27-28, 2010, which provided a forum for industry and researchers to exchange information and to discuss the issues relating to replacement of AmBe, and potentially other isotope sources used in well logging.

07 ISOTOPE AND RADIATION SOURCES↗

457-nm radiation source based on a diode laser for precision spectroscopy of magnesium atoms

We report on the development of a highly stable source of 457-nm radiation based on a diode laser and a tapered amplifier operating in a double-pass scheme. The diode laser frequency was stabilised by a high-Q reference Fabry – Perot interferometer and doubled in a PPSLT nonlinear crystal placed in an enhancement cavity. At a maximum output power of 200 mW at a wavelength of 457 nm, the laser linewidth was less than 5 kHz. The radiation source operation was demonstrated in experiments on precision spectroscopy of cold magnesium atoms in a magneto-optical trap. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Sources and Criticality Safety - 14392

This paper consists essentially of a two part discussion concerning the effects that extraneous radiation sources have on fissionable material systems with respect to criticality and criticality safety. The first part (sections 2 and 3) concentrates on a qualitative discussion about extraneous radiation sources and definitions associated with the criticality of neutron chain reacting systems. The second part (section 4), while it does not constitute a rigorous proof, focuses more on the mathematics governing neutron distribution in general and fissionable material systems. The goal of both parts is the same, i.e. to dispel the notion that a subcritical system can be driven critical by simply supplying a source of neutrons to make up losses. Either part, or both, can be relied on as references in situations in which a criticality safety concern is inappropriately raised for situations where extraneous radiation sources are utilized to perform measurements with subcritical configurations of special nuclear materials. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Free electron terahertz wave radiation source with two-section periodical waveguide structures

We analyze a free electron terahertz wave radiation source with two-section periodical waveguide structure (PWS), where the first section (section-I) is used to pre-modulate the electron beam and the second section (section-II) is for terahertz wave generation. By means of theoretical analysis and numerical simulations, we demonstrate that the starting current density of the beam-wave interaction in section-II can be significantly reduced provided that the operation frequency is the harmonic of electron beam's pre-modulation frequency. This kind of source can generate relatively high power terahertz wave radiation but only need moderate beam current density. And it may have great potential application in developing the compact and high power terahertz wave radiation source.

07 ISOTOPE AND RADIATION SOURCES↗

Network Algorithms for Detection of Radiation Sources

In support of national defense, Domestic Nuclear Detection Office’s (DNDO) Intelligent Radiation Sensor Systems (IRSS) program supported the development of networks of radiation counters for detecting, localizing and identifying low-level, hazardous radiation sources. Industry teams developed the first generation of such networks with tens of counters, and demonstrated several of their capabilities in indoor and outdoor characterization tests. Subsequently, these test measurements have been used in algorithm replays using various sub-networks of counters. Test measurements combined with algorithm outputs are used to extract Key Measurements and Benchmark (KMB) datasets. We present two selective analyses of these datasets: (a) a notional border monitoring scenario that highlights the benefits of a network of counters compared to individual detectors, and (b) new insights into the Sequential Probability Ratio Test (SPRT) detection method, which lead to its adaptations for improved detection. Using KMB datasets from an outdoor test, we construct a notional border monitoring scenario, wherein twelve 2”*2” NaI detectors are deployed on the periphery of 21*21meter square region. A Cs-137 (175 uCi) source is moved across this region, starting several meters from outside and finally moving away. The measurements from individual counters and the network were processed using replays of a particle filter algorithm developed under IRSS program. The algorithm outputs from KMB datasets clearly illustrate the benefits of combining measurements from all networked counters: the source was detected before it entered the region, during its trajectory inside, and until it moved several meters away. When individual counters are used for detection, the source was detected for much shorter durations, and sometimes was missed in the interior region. The application of SPRT for detecting radiation sources requires choosing the detection threshold, which in turn requires a source strength estimate, typically specified as a multiplier of the background radiation level. A judicious selection of this source multiplier is essential to achieve optimal detection probability at a specified false alarm rate. Typically, this threshold is chosen from the Receiver Operating Characteristic (ROC) by varying the source multiplier estimate. ROC is expected to have a monotonically increasing profile between the detection probability and false alarm rate. We derived ROCs for multiple indoor tests using KMB datasets, which revealed an unexpected loop shape: as the multiplier increases, detection probability and false alarm rate both increase until a limit, and then both contract. Consequently, two detection probabilities correspond to the same false alarm rate, and the higher is achieved at a lower multiplier, which is the desired operating point. Using the Chebyshev’s inequality we analytically confirm this shape. Then, we present two improved network-SPRT methods by (a) using the threshold off-set as a weighting factor for the binary decisions from individual detectors in a weighted majority voting fusion rule, and (b) applying a composite SPRT derived using measurements from all counters.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Method and system for imaging a radiation source

A method for imaging a radiation source, and a device that utilizes these methods that in one embodiment include the steps of: calculating at least one Compton cone of a first parameter of a radiation emission from information received from a sensor occurrence; and tracing this Compton cone on to a unit sphere having preselected characteristics using an estimated angular uncertainty to limit at least a portion of said tracing. In another embodiment of the invention at least two Compton cones are calculated and then intersected upon a predefined surface such as a sphere. These intersection points can then be iterated over a preselected series of prior events.

Myjak, Mitchell J↗

High-viscosity injector-based pink-beam serial crystallography of microcrystals at a synchrotron radiation source

Since the first successful serial crystallography (SX) experiment at a synchrotron radiation source, the popularity of this approach has continued to grow showing that third-generation synchrotrons can be viable alternatives to scarce X-ray free-electron laser sources. Synchrotron radiation flux may be increased ∼100 times by a moderate increase in the bandwidth (`pink beam' conditions) at some cost to data analysis complexity. Here, we report the first high-viscosity injector-based pink-beam SX experiments. The structures of proteinase K (PK) and A 2A adenosine receptor (A 2A AR) were determined to resolutions of 1.8 and 4.2 Å using 4 and 24 consecutive 100 ps X-ray pulse exposures, respectively. Strong PK data were processed using existing Laue approaches, while weaker A 2A AR data required an alternative data-processing strategy. This demonstration of the feasibility presents new opportunities for time-resolved experiments with microcrystals to study structural changes in real time at pink-beam synchrotron beamlines worldwide.

36 MATERIALS SCIENCE↗

Blackbody radiation sources for the IR spectral range

Metrological radiometric facilities for optoelectronic instruments calibration utilize in terms of standards as radiation detectors in a form of cryogenic radiometers (CR), so as radiation sources. However in practice, there are no CR working within IR spectral range. An alternative way of radiometric calibration in middle and far IR ranges is to develop a parametric series of standard radiation sources - blackbody (BB) models. The paper describes some of BBs developed at VNIIOFI for the last time [1] from cryogenic (80 K to 200 K), to low (about 200 K to 400 K) and medium (400 K to 700 K) temperature regions for calibration of the IR instruments under cryogenic-vacuum conditions. These BBs are presented by models of both types: variable-temperature and based on fixed points of Ga or In. BBs are characterized with high temperature uniformity and stability. Copper and aluminum alloys are used as the radiation cavity materials. The required value of emissivity ε{sub λ} is achieved by using different black coatings. Low-temperature and cryogenic BBs are based on the principles of indirect multi-zone electric heating (with heat isolation from LN2 cooling loop, or by using an external liquid thermostat with circulating heat-transfer agent. The principles of operation, design and test results of BBs are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SCALE 6.3.1 Radiation Source Terms and Shielding Analysis for a Postulated Sodium-Cooled Fast Reactor Accident Scenario

In support of the US Nuclear Regulatory Commission non–light-water reactor fuel cycle demonstration project, SCALE 6.3.1 capabilities for radiation source term and shielding calculations are demonstrated for scenarios in the sodium-cooled fast reactor (SFR) fuel cycle. A postulated accident scenario, which consists of a seismic event causing the refueling machine to fall and release a spent fuel assembly inside the containment building (CB), is analyzed in this paper. Radiation source terms were generated for a U/TRU-10Zr metal fuel assembly with a 16.5% initial transuranic waste content and a discharge burnup of approximately 95 GWd/tHM; source terms were also generated for a high-assay low-enriched uranium metal fuel assembly (U-10Zr) with a 16.5% initial enrichment and a discharge burnup of 149.74 GWd/tHM. These radiation source terms were then used to determine the dose rate inside the CB and near the outer surface of the CB for a range of spent fuel assembly cooling times. The dose rate produced by the analyzed SFR assemblies is similar to that produced by a typical pressurized water reactor assembly with a discharge burnup of 50 GWd/MTU. Ultimately, the validation of the source terms predicted for SFRs with SCALE will need to be demonstrated via the use of assay measurements.

Radulescu, Georgeta↗

Devices Materials and Processes for Nanoelectronics: Characterization with Advanced X-Ray Techniques Using Lab-Based and Synchrotron Radiation Sources

Future nanoelectronics manufacturing at extraordinary length scales, new device structures, and advanced materials will provide challenges to process development and engineering but also to process control and physical failure analysis. Advanced X-ray techniques, using lab systems and synchrotron radiation sources, will play a key role for the characterization of thin films, nanostructures, surfaces, and interfaces. The development of advanced X-ray techniques and tools will reduce risk and time for the introduction of new technologies. Eventually, time-to-market for new products will be reduced by the timely implementation of the best techniques for process development and process control. The development and use of advanced methods at synchrotron radiation sources will be increasingly important, particularly for research and development in the field of advanced processes and new materials but also for the development of new X-ray components and procedures. The application of advanced X-ray techniques, in-line, in out-of-fab analytical labs and at synchrotron radiation sources, for research, development, and manufacturing in the nanoelectronics industry is reviewed. The focus of this paper is on the study of nanoscale device and on-chip interconnect materials, and materials for 3D IC integration as well.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Generation of controlled radiation sources in the atmosphere using a dual femtosecond /nanosecond laser pulse

The generation of powerful radiation sources at predetermined remote locations in the atmosphere using dual femtosecond/nanosecond laser pulses is proposed. The plasma channel generated in the wake of the collapsed beam formed during intense ultrashort pulse propagation in the atmosphere serves as seed target plasma to absorb energy delivered by a long pulse laser, inducing further ionization and significantly enhancing the energy density locally deposited in the plasma. Energy equipartition on time scales shorter than 1 {mu}s results in large energy density in the heated air and is followed by several orders of magnitude enhancement of the radiation emitted by the plasma channel. The effect is demonstrated using a one-dimensional computational study. A proof-of-principle experiment is suggested.

07 ISOTOPE AND RADIATION SOURCES↗

Broadband Ho{sup 3+}-doped fibre radiation source emitting at 2 {mu}m

A 2-{mu}m broadband radiation source based on a fibre doped with holmium ions, which is pumped by a 1.12-{mu}m ytterbium fibre laser, is developed. The maximum output power of 8 mW is achieved for the emission spectrum width of 45 nm. (active optical fibres)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Repetitively pulsed UV radiation source based on a run-away electron preionised diffuse discharge in nitrogen

An extended repetitively pulsed source of spontaneous UV radiation is fabricated, which may also be used for producing laser radiation. Voltage pulses with an incident wave amplitude of up to 30 kV, a half-amplitude duration of ∼4 ns and a rise time of ∼2.5 ns are applied to a gap with a nonuniform electric field. For an excitation region length of 35 cm and a nitrogen pressure of 30 – 760 Torr, a diffusive discharge up to a pulse repetition rate of 2 kHz is produced without using an additional system for gap preionisation. An investigation is made of the plasma of the run-away electron preionised diffuse discharge. Using a CCD camera it is found that the dense diffused plasma fills the gap in a time shorter than 1 ns. X-ray radiation is recorded from behind the foil anode throughout the pressure range under study; a supershort avalanche electron beam is recorded by the collector electrode at pressures below 100 Torr. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mo/Si multilayer-coated amplitude-division beam splitters for XUV radiation sources

Amplitude-division beam splitters for XUV radiation sources have been developed and extensively characterized. Mo/Si multilayer coatings were deposited on 50 nm-thick SiN membranes. By changing the multilayer structure (periodicity, number of bilayers, etc.) the intensity of the reflected and transmitted beams were optimized for selected incident radiation parameters (wavelength, incident angle). The developed optical elements were characterized by means of XUV reflectometry and transmission measurements, atomic force microscopy and optical interferometry. Special attention was paid to the spatial homogeneity of the optical response and reflected beam wavefront distortions. Here the results of the characterization are presented and improvements required for advanced applications at XUV free-electron lasers are identified. A flatness as low as 4 nm r.m.s. on 3 × 3 mm beam splitters and 22 nm r.m.s. on 10 × 10 mm beam splitters has been obtained. The high-spatial-frequency surface roughness was about 0.7–1 nm r.m.s. The middle-spatial-frequency roughness was in the range 0.2–0.8 nm r.m.s. The reflection and transmission of the beam splitters were found to be very homogeneous, with a deviation of less than 2% across the full optical element.

47 OTHER INSTRUMENTATION↗

Surrogate-Based Robust Design for a Non-Smooth Radiation Source Detection Problem

In this paper, we develop and numerically illustrate a robust sensor network design to optimally detect a radiation source in an urban environment. This problem exhibits several challenges: penalty functionals are non-smooth due to the presence of buildings, radiation transport models are often computationally expensive, sensor locations are not limited to a discrete number of points, and source intensity and location responses, based on a fixed number of sensors, are not unique. We consider a radiation source located in a prototypical 250 m × 180 m urban setting. To address the non-smooth properties of the model and computationally expensive simulation codes, we employ a verified surrogate model based on radial basis functions. Using this surrogate, we formulate and solve a robust design problem that is optimal in an average sense for detecting source location and intensity with minimized uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient UV and VUV Radiation Sources – Excilamps and Photoreactors on Their Basis

Results of investigations of UV and VUV radiation sources (excilamps) based on inert gases and mixtures of inert gases with halides are presented. Conditions are described in which maximum radiation parameters are attained. Photoreactors and irradiators promising for application in medicine, agriculture, and gas industry have been developed based on the excilamps.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new facility for the synchrotron radiation-based calibration of transfer radiation sources in the ultraviolet and vacuum ultraviolet spectral range

The Physikalisch-Technische Bundesanstalt (PTB) has a long tradition in the calibration of radiation sources in the ultraviolet and vacuum ultraviolet spectral range, with traceability to calculable synchrotron radiation. Within this context, new instrumentation in the PTB laboratory at the Metrology Light Source (MLS) has been put into operation that opens up extended and improved calibration possibilities. A new facility for radiation source calibrations has been set up in the spectral range from 7 nm to 400 nm based on a combined normal incidence-grazing incidence monochromator. The facility can be used for the calibration of transfer sources in terms of spectral radiant intensity or mean spectral radiance, with traceability to the MLS primary source standard. We describe the design and performance of the experimental station and give examples of some commissioning results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗