Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RTES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

32 records · Page 2

Refractory-based thermal energy storage for industrial process heat: one-dimensional modeling, control, and optimization

The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.

25 ENERGY STORAGE↗

A low temperature unitized regenerative fuel cell realizing 60% round trip efficiency and 10 000 cycles of durability for energy storage applications

Unitized regenerative fuel cells (URFC) convert electrical energy to and from chemical bonds in hydrogen. URFCs have the potential to provide economical means for efficient long-term, seasonal, energy storage and on-demand conversion back to electrical energy. We first optimize the catalyst layer for discrete electrolyzer and fuel cell and then configure the URFC. The goal is to identify a cost competitive configuration for URFCs, and demonstrate it in terms of upper limit of round trip efficiencies (RTEs). Two possible configurations of URFCs are compared via experiments and techno-economic analysis (TEA), which emphasize the advantages of the unconventional constant-electrode (CE) URFC over the traditional constant-gas (CG) configuration. We also study the stability via accelerated stress tests (ASTs) and demonstrate steady state operation in a daily cycle for day to night energy shifting. From the investigations, the optimum composition of the URFC anode catalyst layer is 90 at% Ir-black balanced by Pt-black for both CE and CG configurations. At 80 °C and 1 A cm -2 , the optimized CE URFC achieves 57% and 60% RTE with air and O 2 as the reductant gases, respectively. We then evaluated the differences in durability using an AST over 10k charge–discharge cycles; the results reveal that the wider potential window at the anode in CE (0.05–1.55 V) has minimal effect on catalyst layer stability compared to CG (0.55–1.55 V). Furthermore, there was no degradation up to the range of 2k–5k cycles; beyond that the fuel cell (discharge) performance degraded while the electrolyzer (charge) performance was still stable. Finally, the observations here indicate substantial potential to employ URFCs as efficient and cost-effective bidirectional energy-conversion devices within energy storage and utilization systems after appropriate technological and operational optimizations.

25 ENERGY STORAGE↗

Tailoring the Mass Transport to Achieve High-Performing Unitized Regenerative Fuel Cells Considering Practical Operating Conditions

Unitized regenerative fuel cells (URFCs) convert electrical energy to chemical bonds in hydrogen during charge and convert chemical energy to output electricity during discharge, offering a promising solution to long-term energy storage. Recent studies indicate that the round-trip-voltaic efficiency (RTE) and longevity of URFCs are limited by complex mass transport during charging and discharging. Here, we first investigate how different porous transport layer (PTL) structures can impact URFC performance. The preferred PTL has a low tortuosity and high porosity, leading to a high RTE above 50% at 1 A cm −2 using Nafion 212. Moreover, thicker membranes, such as Solvay 90, are required to ensure mechanical stability and minimize H 2 crossover when operating under high differential pressure. Although this assembly inevitably leads to a higher ohmic loss, the RTE can be improved by further tailoring the electrode structures to facilitate mass transport by using supported catalyst, which still achieves over 50% RTEs at 1 A cm −2 . Optimization of porous structure to mitigate mass transport resistance with appropriate materials down selection considering practical application requirements can be a key design principle for achieving high-performing URFCs.

25 ENERGY STORAGE↗

Renewable Thermal Energy Systems Designed for Industrial Process Solutions in Multiple Industries

The need for renewable heat in industry is vital for the next decade and beyond. Industrial decarbonization is a key area that must be accelerated, to foster the removal of fossil fuels from the provision of heat, especially at low temperatures. This paper looks at the development and results of case studies for understanding the economics and potential for renewable thermal energy systems (RTES), particularly in hybrid configurations to provide industrial process heat (IPH). For the case studies, these include non-concentrating e.g., heat pumps, and concentrating collectors e.g., parabolic trough collectors and direct steam generation (DSG)-linear Fresnel collectors (LFCs). The results show that a levelized cost of heat (LCOH) of $6-$8 per million British Thermal Units (MMBTU) is possible, depending on the direct normal irradiance (DNI) and the system sizing e.g., to increase the solar fractions. In Arizona for example, with a DNI of 7.36 kWh/m2/day, the base case for the DSG-LFC system with 6hrs of thermal energy storage could potentially meet a 1 MWth load 80% of the year.

concentrated solar thermal↗

Renewable Thermal Energy Systems: Modeling Developments and Future Directions (Report 3)

Increasing global energy consumption, increasing population, expansion of all types of produced goods and food, and the climate crisis have necessitated increasing the share of renewable heat in industry, which is vital for both decarbonization. The aim of this work is to evaluate current and prospective renewable heat technologies in stand-alone and hybrid configurations, together with their technical capabilities, performance, and cost. Renewable thermal energy systems (RTES) for buildings and industrial applications have been investigated using techno-economic analysis to determine their potential economic and environmental impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TCF - Sustainable Well Cement for Geothermal, Thermal Recovery, and Carbon Storage wells

Primary cementing is the most important operation performed on a subterranean well. Cement, placed in the annulus between the casing and the formations, serves as a hydraulic seal preventing fluids and gas migrations, protecting steel casing from corrosion, and supporting the well structure. Poor cementing jobs can be directly responsible for wells not reaching their full capacity, casing corrosion, compromised well integrity and, in the worst-case scenarios, well collapse. Geothermal, thermal recovery, and carbon storage wells offer environments that are especially difficult for cements to survive while the required lifespan of these wells can be years. In these wells currently used cements cannot provide durable well integrity, and new solutions are necessary. The necessity of stabilizing the electric grid, increasing its flexibility, and providing energy on demand will further expand the market of durable cement solutions for applications in high-temperature underground reservoir thermal energy storage wells (HT RTES). The design challenges of special cement systems for such wells originate from chemistry limitations of currently used well cements, aggressive environments, temperature and repeated shock conditions associated with them, and very weak formations that are not uncommon in these wells. During the last 70 years the most common systems for thermal-well construction have been Ordinary Portland Cement (OPC) (absolute majority of the wells), silica-lime system, and high aluminum cement-containing formulations. The major issues of calcium-silicate hydrates, that form during the hydration of OPC resulting in hardened material, are their poor chemical resistance to acids due to the calcium interactions with acid anions followed by its eventual dissolution, even in mild acids, such as carbonic acid from CO 2 dissolution, and inadequate bonding to the steel causing serious casing corrosion problems (Sugama & Pyatina, 2019). Performance of OPC-based cement may be significantly improved with organic additives; however, those are limited by their temperature stability. An alternative to calcium-silicate cement was developed by BNL and commercialized by Halliburton as ThermaLock TM cement. Calcium-aluminate-phosphate-based chemistry of the material allowed overcoming acid-resistance problems of OPC, especially in CO 2 -rich geothermal environments. In 2012-2015, building upon this experience, BNL developed Thermal Shock Resistant Cement (TSRC) with the support of Geothermal Technology Office (GTO) of DOE. TSRC has high-temperature stable chemistry, superior properties of cement-metal casing bond and corrosion protection (4-times better than currently used OPC-based formulation), significantly outperforms common well-cements in thermal-shock tests, has self-healing properties, and like ThermaLock TM is CO 2 resistant incorporating carbonate ions into stable hydrates (Gill et al., 2012).

15 GEOTHERMAL ENERGY↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Renewable Thermal Energy Systems Designed for Industrial Process Solutions in Multiple Industries

Industrial decarbonization is a key area that must be accelerated, to foster the removal of fossil fuels from the provision of heat, especially at low temperatures less than 300 degrees C. This paper looks at the results of two case studies for understanding the economics and potential for renewable thermal energy systems (RTES), particularly in hybrid configurations to provide industrial process heat (IPH). The first case study looks at heat pumps for district heating, and the second, the use of linear Fresnel collectors (LFCs) coupled with phase change material (PCM) thermal energy storage (TES) for direct steam generation (DSG). Using district heat as an input for the heat pump, three cases were run harvesting energy from ambient water (5 degrees C), sewage water (20 degrees C), and a solar collector (35 degrees C). Accounting for elevated costs of infrastructure for each heat source, the levelized cost of heat (LCOH) of the first case study ranged from $4-$15 per million British Thermal Units (MMBTU). For the second case study modeling LFCs with PCM and TES, the results show that a LCOH of $9-$15 per MMBTU is possible, depending on the direct normal irradiance.

concentrated solar thermal↗

Renewable Thermal Energy Systems Designed for Industrial Process Solutions in Multiple Industries: Preprint

Industrial decarbonization is a key area that must be accelerated, to foster the removal of fossil fuels from the provision of heat, especially at low temperatures less than 300 degrees C. This paper looks at the results of two case studies for understanding the economics and potential for renewable thermal energy systems (RTES), particularly in hybrid configurations to provide industrial process heat (IPH). The first case study looks at heat pumps for district heating, and the second, the use of linear Fresnel collectors (LFCs) coupled with phase change material (PCM) thermal energy storage (TES) for direct steam generation (DSG). Using district heat as an input for the heat pump, three cases were run harvesting energy from ambient water (5 degrees C), sewage water (20 degrees C), and a solar collector (35 degrees C). Accounting for elevated costs of infrastructure for each heat source, the levelized cost of heat (LCOH) of the first case study ranged from $4-$10 per million British Thermal Units (MMBTU). For the second case study modeling LFCs with PCM and TES, the results show that a LCOH of $9-$15 per MMBTU is possible, depending on the direct normal irradiance.

concentrated solar thermal↗

Reactive Transport Simulations of High-Tempertature Geologic Thermal Energy Storage (GeoTES) in Deep Saline Formations - I/O Files

Simulation input and output files, post-processed figures and excel tables, and tecplot layout files for generating figures. These simulations were run with TOUGHREACT V4.12 by Lawrence Berkeley National Laboratory in 2021. This work was completed as part of the geologic thermal energy storage (GeoTES) research project reported in the final report for Phase I of this work, which is linked below.

15 GEOTHERMAL ENERGY↗

Techno-Economic Analysis and Market Potential of Geological Thermal Energy Storage (GeoTES) Charged With Solar Thermal and Heat Pumps

In this project, we developed a techno-economic analysis (TEA) model that can be used to evaluate the viability of a proposed Geological Thermal Energy Storage (GeoTES) design. This MATLAB-based model integrates distinct subsystem models for the reservoir, wells, power cycle, and solar field to capture their distinct characteristics. It applies this approach in simulating GeoTES storage and dispatch operations for durations ranging from hourly to seasonal. Using cases studies based on GeoTES designs provided by industry partners - Premier Resource Management (PRM) and EarthBridge Energy - we validated the TEA model estimations of system performance and costs (such as thermal and electrical power/energy inflow and outflow, capital costs, and levelized costs of energy and storage) for both concentrating solar thermal (CST) and Carnot Battery (CB) pairings with GeoTES (CST-GeoTES and CB-GeoTES). For the CST-GeoTES case, the model was validated against the proposed system designed by PRM. It showed good agreement with PRM's estimations when well and pump costs derived from PRM's estimations were used. When GETEM-based costs were used, there was a slight overprediction due to GETEM's project/site agnostic assumption of these costs. From a sensitivity analysis perspective, the levelized cost of electricity (LCOE) of the CST-GeoTES case was most sensitive to well flow rate and the charging temperature. An optimal design scenario resulted in an LCOE of 0.11 $\$$/kWhe. CST-GeoTES can also provide a source of heat to meet seasonal demands. With 12-hour and 24-hour levelized cost of heat (LCOH) of 0.018 $\$$/kWhth and 0.022 $\$$/kWhth, respectively, CST-GeoTES could be competitive in the California market with an average industrial price of natural gas in California between 0.041-0.047 $\$$/kWhth. The levelized cost of storage (LCOS) for CST-GeoTES depends on the energy storage duration. Although the LCOS is relatively higher for shorter durations (e.g., ~0.50 $\$$/kWhe for 1 hour of storage), it is an order of magnitude lower (0.06 $\$$/kWhe) for longer storage durations and competitive with lithium-ion batteries (beyond 12 hours of storage) and molten-salt thermal energy storage (beyond 32 hours). Energy. Three options were explored and applied to the EarthBridge case study: (1) A Carnot Battery design using R125 working fluid with both hot and cold storage; (2) A Carnot Battery design using R125 working fluid with only hot storage; (3) A Carnot Battery using a commercially available heat pump with carbon dioxide (CO2) working fluid and hot storage only. The CB-GeoTES with cold storage only had a slight (round-trip) efficiency advantage over the system without (43.4% vs. 42.8%). This is because the cold storage is limited by the freezing point of water, so the cold storage is not much colder than the environment. The system using commercially available technologies was the least efficient - partly because different cycles were used in the heat pump (CO2) and heat engine (binary cycle) which leads to some inefficiencies. Using the commercially available design, the levelized cost of energy (LCOS) from the model (0.10 $\$$/kWhe) was higher than that estimated by EarthBridge (0.068 $\$$/kWhe). This is because of the low round-trip (38.7%) efficiency of the commercially available design. Sensitivity analysis reveals that the model is most sensitive to electricity price. Including electricity price in the TEA for CB-GeoTES leads to an increase in LCOS from the base value to 0.25 $\$$/kWhe. To determine storage sites suitable for GeoTES, we gathered and analyzed geological, petrophysical, and geophysical data of oil and gas reservoir and aquifers in California and Texas. We down-selected possible sites based on cut-off values for site characteristics (e.g., reservoir temperature, formation thickness, permeability, porosity, depth, and brine salinity) and preliminary costs. Using this approach, the Carrizo-Wilcox, Yegua-Jackson, and Dockum brackish aquifers in Texas were identified as having the highest suitability. Similarly, in the central California region, the White Wolf, Belridge South Tulare, and Belridge South Reef Ridge were the most suitable. Going further, we assessed the storage potential in the selected sites. To do this we developed distributions of reservoir characteristic data and applied a Monte Carlo-based analysis to account for intrinsic uncertainty in the acquired data. The analysis revealed that the Carrizo-Wilcox aquifer had the highest storage potential with a mean capacity of 554 TWhth (i.e., 63 TWhe). The estimated capacity serves as an upper limit of storage potential given that not all fields in the basin will be developed. We participated in multiple outreach activities including conference presentations, panel session discussions, and the facilitation of a GeoTES workshop at the NREL Golden campus.

15 GEOTHERMAL ENERGY↗

Reducing Data Center Peak Cooling Demand and Energy Costs with Underground Thermal Energy Storage (UTES)

By recent estimates, data center energy demands are projected to consume between 6.7% and 12% of U.S. annual electricity generation by the year 2028, driven primarily by expanded demands from cloud services, big data analytics, and Artificial Intelligence (AI) (Shehabi et al., 2024). As much as 40% of data center total energy consumption are loads associated with the site infrastructure cooling systems, and these are often highly water consumptive (Aljbour et al., 2024). For energy system planners, this presents significant challenges to meeting and managing the anticipated loads, and especially the peak loads of projected data center deployments. Geothermal technologies offer two unique solutions to these challenges: 1) by serving loads through the deployment of new conventional and/or next-generation geothermal power technologies such as EGS and 2) through an often-overlooked opportunity to reduce data center peak cooling loads. The latter is the focus of this paper which explores Cold Underground Thermal Energy Storage ("Cold UTES") as an emerging industrial-scale geothermal cooling solution. This cooling solution is energy efficient, non-water-consumptive, and utilizes long duration energy storage (LDES) on both diurnal and seasonal time scales. Cold UTES has the potential to also function as a virtual power plant (VPP). The US Department of Energy's Geothermal Technologies Office is supporting R&D to understand the grid and system-wide value, costs, and impacts of deploying this emergent cooling solution at scale.

AI↗