Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The Use of High Energy Heavy Ion Facilities for Single Event Effects (SEE) Testing: A Perspective on Return on Investment (ROI)

With challenges related to testing highly complex integrated circuits as well as entire systems continuing to grow, the use of higher energy heavy ions for single-event effects (SEE) testing becomes a critical technical need. This presentation, however, focuses only partially on the technical side with the main emphasis on the economics of using a high-energy heavy ion beam and comparing via notional cost models for testing.

Kenneth A. LaBel↗

Increasing ROI Using Your Digital Twin for Model Based Engineering

The purpose of this work is to identify innovative ways of using the plant reference simulator or digital twin differently than it has traditionally been used in the past. This paper will identify reasons that the plant reference simulator will support varying levels of model based design and engineering. I will point out real world examples in which the plant reference simulator was used to identify problems with engineering designs, digital control systems and plant modifications. The earlier these issues can be identified and resolved, the less impact they have on the plant modification or upgrade. By using the plant reference simulator earlier in the engineering process, utilities and engineering organizations can minimize costly outage extensions and increase the return on the investment made in the simulator.

42 ENGINEERING↗

Evaluation of Deformable Image Coregistration in Adaptive Dose Painting by Numbers for Head-and-Neck Cancer

Purpose: To assess the accuracy of contour deformation and feasibility of dose summation applying deformable image coregistration in adaptive dose painting by numbers (DPBN) for head and neck cancer. Methods and Materials: Data of 12 head-and-neck-cancer patients treated within a Phase I trial on adaptive {sup 18}F-FDG positron emission tomography (PET)-guided DPBN were used. Each patient had two DPBN treatment plans: the initial plan was based on a pretreatment PET/CT scan; the second adapted plan was based on a PET/CT scan acquired after 8 fractions. The median prescription dose to the dose-painted volume was 30 Gy for both DPBN plans. To obtain deformed contours and dose distributions, pretreatment CT was deformed to per-treatment CT using deformable image coregistration. Deformed contours of regions of interest (ROI{sub def}) were visually inspected and, if necessary, adjusted (ROI{sub def{sub ad}}) and both compared with manually redrawn ROIs (ROI{sub m}) using Jaccard (JI) and overlap indices (OI). Dose summation was done on the ROI{sub m}, ROI{sub def{sub ad}}, or their unions with the ROI{sub def}. Results: Almost all deformed ROIs were adjusted. The largest adjustment was made in patients with substantially regressing tumors: ROI{sub def} = 11.8 {+-} 10.9 cm{sup 3} vs. ROI{sub def{sub ad}} = 5.9 {+-} 7.8 cm{sup 3} vs. ROI{sub m} = 7.7 {+-} 7.2 cm{sup 3} (p = 0.57). The swallowing structures were the most frequently adjusted ROIs with the lowest indices for the upper esophageal sphincter: JI = 0.3 (ROI{sub def}) and 0.4 (ROI{sub def{sub ad}}); OI = 0.5 (both ROIs). The mandible needed the least adjustment with the highest indices: JI = 0.8 (both ROIs), OI = 0.9 (ROI{sub def}), and 1.0 (ROI{sub def{sub ad}}). Summed doses differed non-significantly. There was a trend of higher doses in the targets and lower doses in the spinal cord when doses were summed on unions. Conclusion: Visual inspection and adjustment were necessary for most ROIs. Fast automatic ROI propagation followed by user-driven adjustment appears to be more efficient than labor-intensive de novo drawing. Dose summation using deformable image coregistration was feasible. Biological uncertainties of dose summation strategies warrant further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a method for activity estimation in Sm-153 EDTMP imaging

Absolute activity evaluation is fundamental for internal radionuclide dosimetry when patient-specific therapy optimization is wanted. Often, quantification is attempted with 3D SPECT image based (IB) methods, but the true concentration values can be underestimated due to the partial volume effect (PVE). This is especially true when small diffuse lesions are present. In this paper, we describe a 3D region of interest (ROI) based quantification method (LS-ROI), which estimates the ROI concentration values directly from the projection data acquired in the tomographic scan once ROIs have been segmented on a CT and/or a SPECT image. The method, which has inherent PVE correction capabilities, was applied both on simulated and on real phantom data. Simulations reflected the case of a patient with bone metastases treated with {sup 153}Sm-EDTMP: Both the activity in the metastases and the total retention in the skeleton were evaluated. Thirty noisy data sets were produced in order to evaluate the accuracy and precision of the method. The effect of region segmentation errors on estimated concentrations was thoroughly investigated. Real data were acquired on a NEMA phantom, where a cylindrical central region (283 cm{sup 3}) simulated the bone and two spheres (10.3 and 25.5 cm{sup 3}) simulated the metastases. The results obtained with the LS-ROI method were compared with those of a conventional 3D IB method and those of a quantitative conjugate view approach derived from LS-ROI and applied to the anterior and posterior views acquired in the tomographic scan (LS-ROI anterior-posterior: LS-ROI-AP). Simulations showed that when the geometry of regions is known, the LS-ROI method recovered the simulated concentration values within 20%, while the IB method underestimated the concentration in high activity small lesions by as much as 49%. Segmentation errors, up to 44% of the true region volume, produced a higher variation in LS-ROI estimates than in IB ones; however, the overall bias of the LS-ROI estimates ({<=}25%) remained lower than that of IB estimates. In the case of the evaluation of the total retention in the skeleton, the LS-ROI method recovered the simulated value within 2%, while IB underestimated it up to 13%. In all the cases, the LS-ROI-AP method showed an accuracy comparable with that of the LS-ROI one, and a worse precision just because of the lower number of counts used in the analysis. However, a worsening of LS-ROI-AP performances was demonstrated in the case of strong overlap of regions: In this case, a bias of up to 40% was observed. The results obtained on real phantom data confirmed the simulation results: The IB method underestimated activity up to 47% in the smallest sphere, while the bias was reduced to 13% with LS-ROI and LS-ROI-AP estimates. The good quantification capabilities of the LS-ROI method can be useful for absolute activity quantification in the case of small active diffused lesions and constitute the basis for the development of an accurate patient-specific planning strategy in internal radionuclide treatments, provided there is a reliable segmentation of lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-32: Dosimetric Evaluation Based On Pre-Treatment Cone Beam CT for Spine Stereotactic Body Radiotherapy: Does Region of Interest Focus Matter?

Purpose: Spine stereotactic body radiotherapy requires very conformal dose distributions and precise delivery. Prior to treatment, a KV cone-beam CT (KV-CBCT) is registered to the planning CT to provide image-guided positional corrections, which depend on selection of the region of interest (ROI) because of imperfect patient positioning and anatomical deformation. Our objective is to determine the dosimetric impact of ROI selections. Methods: Twelve patients were selected for this study with the treatment regions varied from C-spine to T-spine. For each patient, the KV-CBCT was registered to the planning CT three times using distinct ROIs: one encompassing the entire patient, a large ROI containing large bony anatomy, and a small target-focused ROI. Each registered CBCT volume, saved as an aligned dataset, was then sent to the planning system. The treated plan was applied to each dataset and dose was recalculated. The tumor dose coverage (percentage of target volume receiving prescription dose), maximum point dose to 0.03 cc of the spinal cord, and dose to 10% of the spinal cord volume (V10) for each alignment were compared to the original plan. Results: The average magnitude of tumor coverage deviation was 3.9%±5.8% with external contour, 1.5%±1.1% with large ROI, 1.3%±1.1% with small ROI. Spinal cord V10 deviation from plan was 6.6%±6.6% with external contour, 3.5%±3.1% with large ROI, and 1.2%±1.0% with small ROI. Spinal cord max point dose deviation from plan was: 12.2%±13.3% with external contour, 8.5%±8.4% with large ROI, and 3.7%±2.8% with small ROI. Conclusion: A small ROI focused on the target results in the smallest deviation from planned dose to target and cord although rotations at large distances from the targets were observed. It is recommended that image fusion during CBCT focus narrowly on the target volume to minimize dosimetric error. Improvement in patient setups may further reduce residual errors.

60 APPLIED LIFE SCIENCES↗

SU-F-J-183: Interior Region-Of-Interest Tomography by Using Inverse Geometry System

Purpose: The inverse geometry computed tomography (IGCT) composed of multiple source and small size detector has several merits such as reduction of scatter effect and large volumetric imaging within one rotation without cone-beam artifact, compared to conventional cone-beam computed tomography (CBCT). By using this multi-source characteristics, we intend to present a selective and multiple interior region-of-interest (ROI) imaging method by using a designed source on-off sequence of IGCT. Methods: All of the IGCT sources are operated one by one sequentially, and each projection in the shape of narrow cone-beam covers its own partial volume of full field of view (FOV) determined from system geometry. Thus, through controlling multi source operation, limited irradiation within ROI is possible and selective radon space data for ROI imaging can be acquired without additional X-ray filtration. With this feature, we designed a source on-off sequence for multi ROI-IGCT imaging, and projections of ROI-IGCT were generated by using the on-off sequence. Multi ROI-IGCT images were reconstructed by using filtered back-projection algorithm. All these imaging process of our study has been performed by utilizing digital phantom and patient CT data. ROI-IGCT images of the phantom were compared to CBCT image and the phantom data for the image quality evaluation. Results: Image quality of ROI-IGCT was comparable to that of CBCT. However, the distal axial-plane from the FOV center, large cone-angle region, ROI-IGCT showed uniform image quality without significant cone-beam artifact contrary to CBCT. Conclusion: ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. Projection of ROI-IGCT is performed by selective irradiation, hence unnecessary imaging dose to non-interest region can be reduced. In this regard, it seems to be useful for diagnostic or image guidance purpose in radiotherapy such as low dose target localization and patient alignment. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗

SU-E-I-37: Low-Dose Real-Time Region-Of-Interest X-Ray Fluoroscopic Imaging with a GPU-Accelerated Spatially Different Bilateral Filtering

Purpose: The purpose of our study is to reduce imaging radiation dose while maintaining image quality of region of interest (ROI) in X-ray fluoroscopy. A low-dose real-time ROI fluoroscopic imaging technique which includes graphics-processing-unit- (GPU-) accelerated image processing for brightness compensation and noise filtering was developed in this study. Methods: In our ROI fluoroscopic imaging, a copper filter is placed in front of the X-ray tube. The filter contains a round aperture to reduce radiation dose to outside of the aperture. To equalize the brightness difference between inner and outer ROI regions, brightness compensation was performed by use of a simple weighting method that applies selectively to the inner ROI, the outer ROI, and the boundary zone. A bilateral filtering was applied to the images to reduce relatively high noise in the outer ROI images. To speed up the calculation of our technique for real-time application, the GPU-acceleration was applied to the image processing algorithm. We performed a dosimetric measurement using an ion-chamber dosimeter to evaluate the amount of radiation dose reduction. The reduction of calculation time compared to a CPU-only computation was also measured, and the assessment of image quality in terms of image noise and spatial resolution was conducted. Results: More than 80% of dose was reduced by use of the ROI filter. The reduction rate depended on the thickness of the filter and the size of ROI aperture. The image noise outside the ROI was remarkably reduced by the bilateral filtering technique. The computation time for processing each frame image was reduced from 3.43 seconds with single CPU to 9.85 milliseconds with GPU-acceleration. Conclusion: The proposed technique for X-ray fluoroscopy can substantially reduce imaging radiation dose to the patient while maintaining image quality particularly in the ROI region in real-time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-G-BRD-02: Automated Systematic Quality Assurance Program for Radiation Oncology Information System Upgrades

Purpose: To: (1) describe an independent, automated, systematic software-based protocol for verifying clinical data accuracy/integrity for mitigation of data corruption/loss risks following radiation oncology information system (ROIS) upgrades; and (2) report on application of this approach in an academic/community practice environment. Methods: We propose a robust approach to perform quality assurance on the ROIS after an upgrade, targeting four data sources: (1) ROIS relational database; (2) ROIS DICOM interface; (3) ROIS treatment machine data configuration; and (4) ROIS-generated clinical reports. We investigated the database schema for differences between pre-/post-upgrade states. Paired DICOM data streams for the same object (such as RT-Plan/Treatment Record) were compared between pre-/post-upgrade states for data corruption. We examined machine configuration and related commissioning data files for changes and corruption. ROIS-generated treatment appointment and treatment parameter reports were compared to ensure patient encounter and treatment plan accuracy. This protocol was supplemented by an end-to-end clinical workflow test to verify essential ROI functionality and integrity of components interfaced during patient care chain of activities. We describe the implementation of this protocol during a Varian ARIA system upgrade at our clinic. Results: We verified 1,638 data tables with 2.4 billion data records. For 222 under-treatment patients, 605 DICOM RT plans and 13,480 DICOM treatment records retrieved from the ROIS DICOM interface were compared, with no differences in fractions, doses delivered, or treatment parameters. We identified 82 new data tables and 78 amended/deleted tables consistent with the upgrade. Reports for 5,073 patient encounters over a 2-week horizon were compared and were identical to those before the upgrade. Content in 12,237 xml machine files was compared, with no differences identified. Conclusion: An independent QA/validation approach for ROIS upgrades was developed and implemented at our clinic. The success of this approach ensures a robust QA of ROIS upgrades without manual paper/electronic checks and associated intensive labor.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-12: Impact of Image Registration Algorithms On the Prediction of Pathological Response with Radiomic Textures

Purpose: Tumor regions-of-interest (ROI) can be propagated from the pre-onto the post-treatment PET/CT images using image registration of their CT counterparts, providing an automatic way to compute texture features on longitudinal scans. This exploratory study assessed the impact of image registration algorithms on textures to predict pathological response. Methods: Forty-six esophageal cancer patients (1 tumor/patient) underwent PET/CT scans before and after chemoradiotherapy. Patients were classified into responders and non-responders after the surgery. Physician-defined tumor ROIs on pre-treatment PET were propagated onto the post-treatment PET using rigid and ten deformable registration algorithms. One co-occurrence, two run-length and size zone matrix textures were computed within all ROIs. The relative difference of each texture at different treatment time-points was used to predict the pathologic responders. Their predictive value was assessed using the area under the receiver-operating-characteristic curve (AUC). Propagated ROIs and texture quantification resulting from different algorithms were compared using overlap volume (OV) and coefficient of variation (CoV), respectively. Results: Tumor volumes were better captured by ROIs propagated by deformable rather than the rigid registration. The OV between rigidly and deformably propagated ROIs were 69%. The deformably propagated ROIs were found to be similar (OV∼80%) except for fast-demons (OV∼60%). Rigidly propagated ROIs with run-length matrix textures failed to significantly differentiate between responders and non-responders (AUC=0.65, p=0.07), while the differentiation was significant with other textures (AUC=0.69–0.72, p<0.03). Among the deformable algorithms, fast-demons was the least predictive (AUC=0.68–0.71, p<0.04). ROIs propagated by all other deformable algorithms with any texture significantly predicted pathologic responders (AUC=0.71–0.78, p<0.01) despite substantial variation in texture quantification (CoV>70%). Conclusion: Propagated ROIs using deformable registration for all textures can lead to accurate prediction of pathologic response, potentially expediting the temporal texture analysis process. However, rigid and fast-demons deformable algorithms are not recommended due to their inferior performance compared to other algorithms. The project was supported in part by a Kaye Scholar Award.

60 APPLIED LIFE SCIENCES↗

Single reader between-cases AUC estimator with nested data

The area under the receiver operating characteristic curve (AUC) is widely used in evaluating diagnostic performance for many clinical tasks. It is still challenging to evaluate the reading performance of distinguishing between positive and negative regions of interest (ROIs) in the nested-data problem, where multiple ROIs are nested within the cases. To address this issue, we identify two kinds of AUC estimators, within-cases AUC and between-cases AUC. We focus on the between-cases AUC estimator, since our main research interest is in patient-level diagnostic performance rather than location-level performance (the ability to separate ROIs with and without disease within each patient). Another reason is that as the case number increases, the number of between-cases paired ROIs is much larger than the number of within-cases ROIs. We provide estimators for the variance of the between-cases AUC and for the covariance when there are two readers. We derive and prove the above estimators’ theoretical values based on a simulation model and characterize their behavior using Monte Carlo simulation results. We also provide a real-data example. Moreover, we connect the distribution-based simulation model with the simulation model based on the linear mixed-effect model, which helps better understand the sources of variation in the simulated dataset.

Health Care Sciences & Services↗

How Do Electricity Pricing Programs Impact the Selection of Energy Efficiency Measures? - A Case Study with U.S. Medium Office Buildings

Building owners usually select energy efficiency measures (EEMs) by referring to return on investment (ROI). Current studies tend to apply static energy price to estimate ROI. However, more and more buildings are adopting dynamic electricity pricing programs. To understand how electricity pricing programs impact the selection of EEMs, this paper presents an analysis of the ROIs of EEMs under different pricing programs using U.S. medium office buildings as an example. Eight EEMs in four typical cities are selected as case studies. Considering five electricity pricing programs scenarios (one static program and four dynamic programs), EEMs are selected based on their ROIs. The main findings are: (1) The ROIs of EEMs change under different pricing programs. (2) In Honolulu, Buffalo, and Denver, replacing interior fixtures with higher-efficiency fixtures has a significantly higher ROI than the rest EEMs under all five pricing programs. However, the ROI of this EEM in Honolulu ranges from 28% to 47% for different pricing programs. (3) Similarly, in Fairbanks, replace heating coil with higher-efficiency coil produce higher ROI than the rest under all five pricing programs. (4) For other EEMs, their ROI rankings vary according to electricity pricing programs.

demand response↗