Engineering PapersSearch

SEARCH · Engineering Papers

Results for “RELAXATION TIME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Strategies for Superconducting Transmon Qubits with Millisecond T$_1$ Relaxation Time

Significant strides have been made in extending qubit lifetimes by mitigating lossy materials at various surfaces and interfaces of superconducting transmon qubits. We have recently demonstrated a five-fold improvement of T$_1$ energy relaxation time by encapsulating the Nb surface to prevent native oxide formation. To further extend qubit coherence to millisecond timescales and beyond, we are actively exploring novel strategies. Such strategies include substrate preparation, alternative materials as low loss platforms, novel non-oxide forming low loss capping layers, optimized qubit designs & qubit packaging, and optimized Josephson junction materials, processing, and design. Qubit relaxation time T$_1$ measurements will be reported with best T$_1$’s in excess of a millisecond. This material is based upon work supported by the U.S. Department of Energy, Office of Science, National Quantum Information Science Research Centers, Superconducting Quantum Materials and Systems Center (SQMS) under contract number DE-AC02-07CH11359.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Strategies for Superconducting Transmon Qubits with Millisecond T1 Relaxation Time

Enhancing coherence in superconducting transmon qubits requires suppressing dielectric loss and quasiparticle-mediated dissipation at metal–substrate, metal–vacuum, and substrate–vacuum interfaces. We recently demonstrated a five-fold enhancement of the energy relaxation time (T₁) by encapsulating Nb thin films with a low-loss passivation layer that inhibits NbOₓ formation, thereby reducing two-level system (TLS) participation at the metal surface. To extend T₁ into the millisecond regime, we are implementing a comprehensive materials- and process-level optimization strategy. This includes engineered substrate surface treatments, evaluation of alternative low-loss superconducting and dielectric material stacks, development of ultra-low-loss capping layers, and redesigns of transmon geometries to suppress electric-field participation ratio in lossy regions. Additionally, we are pioneering novel etching processes to further lower surface participation ratios. We are also exploring novel Josephson-junction materials and device layouts to enhance coherence further. We report T₁ measurements from these efforts, with the leading devices achieving relaxation times>1 ms.

Crisa, Francesco

Strategies for Superconducting Transmon Qubits with Millisecond T1 Relaxation Time

Enhancing coherence in superconducting transmon qubits requires suppressing dielectric loss and quasiparticle-mediated dissipation at metal–substrate, metal–vacuum, and substrate–vacuum interfaces. We recently demonstrated a five-fold enhancement of the energy relaxation time (T₁) by encapsulating Nb thin films with a low-loss passivation layer that inhibits NbOₓ formation, thereby reducing two-level system (TLS) participation at the metal surface. To extend T₁ into the millisecond regime, we are implementing a comprehensive materials- and process-level optimization strategy. This includes engineered substrate surface treatments, evaluation of alternative low-loss superconducting and dielectric material stacks, development of ultra-low-loss capping layers, and redesigns of transmon geometries to suppress electric-field participation ratio in lossy regions. Additionally, we are pioneering novel etching processes to further lower surface participation ratios. We are also exploring novel Josephson-junction materials and device layouts to enhance coherence further. We report T₁ measurements from these efforts, with the leading devices achieving relaxation times>1 ms.

Crisa, Francesco

Magnetic resonance imaging of the calcaneus: preliminary assessment of trabecular bone-dependent regional variations in marrow relaxation time compared with dual X-ray absorptiometry

RATIONALE AND OBJECTIVES: Marrow transverse relaxation time (T2*) in magnetic resonance (MR) imaging may be related to the density and structure of the surrounding trabecular network. We investigated regional variations of T2* in the human calcaneus and compared the findings with bone mineral density (BMD), as measured by dual X-ray absorpiometry (DXA). Short- and long-term precisions were evaluated first to determine whether MR imaging would be useful for the clinical assessment of disease status and progression in osteoporosis. METHODS: Gradient-recalled echo MR images of the calcaneus were acquired at 1.5 T from six volunteers. Measurements of T2* were compared with BMD and (for one volunteer) conventional radiography. RESULTS: T2* values showed significant regional variation; they typically were shortest in the superior region of the calcaneus. There was a linear correlation between MR and DXA measurements (r = .66 for 1/T2* versus BMD). Differences in T2* attributable to variations in analysis region-of-interest placement were not significant for five of the six volunteers. Sagittal MR images had short- and long-term precision errors of 4.2% and 3.3%, respectively. For DXA, the precision was 1.3% (coefficient of variation). CONCLUSION: MR imaging may be useful for trabecular bone assessment in the calcaneus. However, given the large regional variations in bone density and structure, the choice of an ROI is likely to play a major role in the accuracy, precision, and overall clinical efficacy of T2* measurements.

Non-NASA Center

Measurement of longitudinal relaxation times for spin-decoupled protons.

Description of an experimental method for the determination of the longitudinal relaxation time for spin-decoupled protons by a modified version of the saturation recovery technique reported by Van Geet and Hume (1965). The described method should facilitate relaxation studies of chemically shifted protons (or fluorines) and can be applied to more complicated spin systems with the aid of triple resonance and noise-decoupling techniques.

Gerace, M. J.

Stochastic fluctuations and the relaxation time in transient relativistic fluids

We argue that the ratio between the shear viscosity and the shear relaxation time, η/τ π , should be defined as a thermodynamic quantity obtained from the equal-time symmetric correlator of the shear-stress tensor. In kinetic theory, we show that this ratio does not depend on the type of interaction. Similarly, an exact expression for this ratio is obtained for holographic gauge theories. We also determine how stochastic fluctuations change η/τ π in transient relativistic hydrodynamics and show that thermal fluctuations do not spoil causality and stability.

Denicol, Gabriel S. [Universidade Federal Fluminen

Relaxation times of remanent magnetisation in lunar fines

On the basis of an analysis of the magnetic parameters, it appears that the bulk of metallic Fe particles in the lunar fines are essentially spherical and have a short remanent relaxation time. These spherical metallic Fe particles could account for the apparently low blocking temperature observed for the unstable components of the natural remanent magnetization detected in the returned lunar samples.

Tsay, F.-D.

Single particle aerodynamic relaxation time analyzer

An instrument employing a laser Doppler velocimeter and a microphone to measure the phase lag of the motion of aerosol particulates relative to the motion of the fluid medium within an acoustic field is described. The relaxation times and aerodynamic diameters of the particles or droplets are determined in real time from the measured values of phase lag; thus, the size analysis is independent of the electrostatic charges and refractive indices of the particulates. The instrument is suitable for analyzing the aerodynamic size spectrum of atmospheric particulate pollutants with aerodynamic diameters ranging from 0.1 to 10.0 microns.

Mazumder, M. K.