Fatigue of reinforced concrete due to sinusoidal and random loadings
Fatigue of reinforced concrete due to sinusoidal and random loadings
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Fatigue of reinforced concrete due to sinusoidal and random loadings
The use of textile-reinforced concrete (TRC) has great potential for innovative solutions in repairing, protecting, and strengthening concrete and RC structures. The article at hand reports on an investigation on composite concrete specimens made of cracked ordinary concrete as substrate and textile-reinforced concrete (TRC) as a cover layer for its strengthening and repair. The TRC cover layer was assessed with regard to its effectiveness as a protective layer against the ingress of water through capillary action. Since in real applications such TRC layers may be cracked or presumed to be so, thereby activating the load-carrying function of the textile reinforcement, the TRC layer was cracked for purposes of this study. The water transport in the cracked ordinary concrete specimens without the TRC layer was used as a reference. Gravimetric measurements and neutron radiography served as the testing techniques. In ordinary concrete quick and deep ingress of water through relatively wide macro-cracks of approximately 100 μm width, followed by transport through the capillary pore system, caused saturation of large areas in a rather short time. TRC applied to the RC surface reduced the ingress of water to a large extent. Its small crack widths of 15 to 20 μm changed suction behaviour fundamentally. In the cracked substrate of ordinary concrete, capillary suction was prevented, and transport through the pore system of the matrix became the prevailing transport mechanism of capillary action. Not only was the mechanism altered, but the transport of water deep into inner regions was markedly retarded as well.
When assessing the feasibility of remediation following the detonation of a radiological dispersion device or improvised nuclear device in a large city, several issues should be considered including the levels and characteristics of the radioactive contamination, the availability of resources required for decontamination, and the planned future use of the city's structures and buildings. Currently, little is known about radionuclide penetration into construction materials in an urban environment. Knowledge in this area would be useful when considering costs of a thorough decontamination of buildings, artificial structures, and roads in an affected urban environment. Pripyat, a city substantially contaminated by the Chernobyl Nuclear Power Plant accident in April 1986, may provide some answers. The main objective of this study was to assess the depth of {sup 90}Sr and {sup 137}Cs penetration into reinforced concrete structures in a highly contaminated urban environment under natural weather conditions. Thirteen reinforced concrete core samples were obtained from external surfaces of a contaminated building in Pripyat. The concrete cores were drilled to obtain sample layers of 0-5, 5-10, 10-15, 15-20, 20-30, 30-40, and 40-50 mm. Both {sup 90}Sr and {sup 137}Cs were detected in the entire 0-50 mm profile of the reinforced cores sampled. In most of the cores, over 90% of the total {sup 137}Cs inventory and 70% of the total {sup 90}Sr inventory was found in the first 0-5 mm layer of the reinforced concrete. {sup 90}Sr had penetrated markedly deeper into the reinforced concrete structures than {sup 137}Cs.
A novel method of testing reinforced concrete beams under impact using a drop tower is described. The method consists of configuring the support conditions and instrumenting both the loading end of the hammer and support points in such a way that a proper dynamic analysis of the impact event can be performed and rational data can be derived.
Many buildings have been damaged due to earthquakes that occurred recently in Indonesia. The main cause of the damage is the large deformation of the building structural component cannot accommodate properly. Therefore, it is necessary to develop the Structural Health Monitoring System (SHMS) to measure precisely the deformation of the building structural component in the real time conditions. This paper presents the development of SHMS for reinforced concrete structural system. This monitoring system is based on deformation component such as strain of reinforcement bar, concrete strain, and displacement of reinforced concrete component. Since the deformation component has exceeded the limit value, the warning message can be sent to the building occupies. This warning message has also can be performed as early warning system of the reinforced concrete structural system. The warning message can also be sent via Short Message Service (SMS) through the Global System for Mobile Communications (GSM) network. Hence, the SHMS should be integrated with internet modem to connect with GSM network. Additionally, the SHMS program is verified with experimental study of simply supported reinforced concrete beam. Verification results show that the SHMS has good agreement with experimental results.
A novel form of alteration due to the interaction between hydrated cement phases and sulfate and phosphate-based pollutants is described, through the characterization of concrete samples from an industrial reinforced concrete building. Decalcification of the cement matrices was observed, with secondary sulfate and phosphate-based mineral formation, according to a marked mineralogical and textural zoning. Five alteration layers may be detected: the two outermost layers are characterized by the presence of gypsum–brushite solid solution phases associated with anhydrous calcium sulfates and phosphates, respectively, while a progressive increase in apatite and ammonium magnesium phosphates is observable in the three innermost layers, associated with specific apatite precursors (brushite, octacalcium phosphate and amorphous calcium phosphate, respectively). The heterogeneous microstructural development of secondary phases is related to the chemical, pH and thermal gradients in the attacked cementitious systems, caused by different sources of pollutants and the exposure to the sun's radiation.
This paper studies the evolution of reinforcement corrosion in comparison to corrosion crack width in a highly corroded reinforced concrete beam. Cracking and corrosion maps of the beam were drawn and steel reinforcement was recovered from the beam to observe the corrosion pattern and to measure the loss of mass of steel reinforcement. Maximum steel cross-section loss of the main reinforcement and average steel cross-section loss between stirrups were plotted against the crack width. The experimental results were compared with existing models proposed by Rodriguez et al., Vidal et al. and Zhang et al. Time prediction models for a given opening threshold are also compared to experimental results. Steel cross-section loss for stirrups was also measured and was plotted against the crack width. It was observed that steel cross-section loss in the stirrups had no relationship with the crack width of longitudinal corrosion cracks. -- Highlights: •Relationship between crack and corrosion of reinforcement was investigated. •Corrosion results of natural process and then corresponds to in-situ conditions. •Comparison with time predicting model is provided. •Prediction of load-bearing capacity from crack pattern was studied.
The use of glass-fiber-reinforced concrete (GRC) as a low-cost structural substrate for terrestrial solar cell arrays is discussed. The properties and fabrication of glass-reinforced concrete structures are considered, and a preliminary design for a laminated solar cell assembly built on a GRC substrate is presented. A total cost for such a photovoltaic module, composed of a Korad acrylic plastic film front cover, an aluminum foil back cover, an ethylene/vinyl acetate pottant/adhesive and a cotton fabric electrical isolator in addition to the GRC substrate, of $9.42/sq m is projected, which is less than the $11.00/sq m cost goal set by the Department of Energy. Preliminary evaluations are concluded to have shown the design capabilities and cost effectiveness of GRC; however, its potential for automated mass production has yet to be evaluated.
Surface treatments on a polypropylene (PP) fibre have contributed to the improvement of fibre/concrete adhesion in fibre-reinforced concrete. The treatments to the PP fibre were characterized by contact angle measurements, ATR-IR and XPS to analyse chemical alterations. The surface topography and fibre/concrete interaction were analysed by several microscopic techniques, namely optical petrographic, and scanning electron microscopy. Treatment modified the surface chemistry and topography of the fibre by introducing sodium moieties and created additional fibre surface roughness. Modifications in the fibre surface led to an increase in the adhesion properties between the treated fibres and concrete and an improvement in the mechanical properties of the fibre-reinforced concrete composite as compared to the concrete containing untreated PP fibres. Compatibility with the concrete and increased roughness and mineral surface was also improved by nucleated portlandite and ettringite mineral association anchored on the alkaline PP fibre surface, which is induced during treatment.
A finite element computational model for the nonlinear analysis of reinforced concrete solid, stiffened and cellular plates is briefly outlined. Typically, Mindlin elements are used to model the plates whereas eccentric Timoshenko elements are adopted to represent the beams. The layering technique, common in the analysis of reinforced concrete flexural systems, is incorporated in the model. The proposed model provides an inexpensive and reasonably accurate approach which can be extended for use with voided plates.
The main purpose of this article is to study compressed reinforced concrete membranes under perpendicular tensile stress. The state-of-the-art is presented and it shows that not much research has been done on this topic, probably because it needed very expensive laboratory equipment. In the current investigation, the authors have tried a new type of equipment, less expensive than that of previous investigations, and it proved to be adequate for the type of tests needed for studying this topic. The authors tested six reinforced concrete panels under pure shear up to failure. A parameter that was studied in these tests was the thickness of the membranes. This is of particular importance in webs or walls of beams under shear or torsion forces. From the experimental measurements, the authors have computed the principal directions and the values of the stresses and strains for the tested beams. In this article, these values are presented and the principal strains and stresses are compared with those at 45° and the two fairly agree with each other, particularly for the case of the stresses.
The Grizzly code has been under development for the U.S. Department of Energy’s Light Water Reactor Sustainability program to provide predictive tools for the evolution of material degradation in critical light water reactor structural components due to long-term exposure to the environmental conditions of normal reactor operation, and for the effects of this degradation on the safety of these components. This development has primarily targeted reactor pressure vessels and reinforced concrete structures. Work performed during Fiscal Year 2019 added important features for both of these types of structures. For probabilistic fracture mechanics analysis of reactor pressure vessels, capabilities were added to account for the effects of warm prestressing and residual stresses, as well as to model crack initiation, growth, and arrest. For modeling microstructure evolution in reactor pressure vessels, a cluster dynamics model for evolution of Mn-Ni-Si phases has been implemented. For modeling degraded reinforced concrete structures, capabilities to consider the combined effects of damage and creep in the concrete constitutive model and model nonlinear behavior of reinforcing bars has been added. These newly-developed features fill important gaps in Grizzly’s feature set for engineering-scale analysis of degraded reactor pressure vessels and reinforced concrete structures. Grizzly development in both of these areas has reached a point where it is ready for extensive testing on relevant engineering problems.
Electrokinetic Nanoparticle (EN) treatment was used as a rapid repair measure to mitigate chloride induced corrosion of reinforced concrete in the field. EN treatment uses an electric field to transport positively charged nanoparticles to the reinforcement through the concrete capillary pores. Cylindrical reinforced concrete specimens were batched with 4.5 wt % salt content (based on cement mass). Three distinct electrokinetic treatments were conducted using high current density (up to 5 A/m2) to form a chloride penetration barrier that was established in 5 days, as opposed to the traditional 6-8 weeks, generally required for electrochemical chloride extraction (ECE). These treatments included basic EN treatment, EN with additional calcium treatment, and basic ECE treatment. Field exposures were conducted at the NASA Beachside Corrosion Test Site, Kennedy Space Center, Florida, USA. The specimens were subjected to sea water immersion at the test site as a posttreatment exposure. Following a 30-day post-treatment exposure period, the specimens were subjected to indirect tensile testing to evaluate treatment impact. The EN treated specimens exhibited 60% and 30% increases in tensile strength as compared to the untreated controls and ECE treated specimens respectively. The surfaces of the reinforcement bars of the control specimens were 67% covered by corrosion products. In contrast, the EN treated specimens exhibited corrosion coverage of only 4%. Scanning electron microscopy (SEM) revealed a dense concrete microstructure adjacent to the bars of the treated specimens as compared to the control and ECE specimens. Energy dispersive spectroscopic (EDS) analysis of the polished EN treated specimens showed a reduction in chloride content by a factor of 20 adjacent to the bars. This study demonstrated that EN treatment was successful in forming a chloride penetration barrier rapidly. This work also showed that the chloride barrier was effective when samples were exposed to field conditions at one of the most severely corrosive environments in North America.
When designing buildings with reinforced concrete that are planned to resist dynamic loads it is necessary to calculate this structural behavior under operational static and emergency impact and blast loads. Calculations of the structures under shock-wave loads can be performed by solving dynamic equations that do not consider static loads. Due to this fact the calculation of reinforced concrete frame under a simultaneous static and dynamic load in full 3d settings becomes a very non trivial and resource consuming problem. This problem can be split into two tasks. The first one is a shock-wave problem that can be solved using software package RANET-3, which allows solving the problem using finite elements method adapted for dynamic task. This method calculates strain-stress state of the material and its dynamic destruction, which is considered as growth and consolidation of micro defects under loading. On the second step the results of the first step are taken as input parameters for quasi static calculation of simultaneous static and dynamic load using finite elements method in AMP Civil Engineering-11.
This paper deals with two corroded reinforcement concrete beams, which have been stored under sustained load in a chloride environment for 14 and 23 years respectively. The evolution of corrosion pattern of reinforcement and its influence on serviceability are studied. In chloride-induced corrosion process, corrosion cracking affects significantly the corrosion pattern. During the corrosion cracking initiation period, only local pitting corrosion occurs. At early stage of cracking propagation, localized pitting corrosion is still predominant as cracks widths are very small and cracks are not interconnected, but a general corrosion slowly develops as the cracks widen. At late cracking stage, interconnected cracking with wide width develops along large parts of the beam leading to a general corrosion pattern. Macrocells and microcells concepts are used for the interpretation of the results. Mechanical experiments and corrosion simulation tests are performed to clarify the influence of this corrosion pattern evolution on the serviceability of the beams (deflection increase). Experimental results show that, when the corrosion is localized (early cracking stage), the steel-concrete bond loss is the main factor affecting the beams serviceability. The local cross-section loss resulting from pitting attack does not significantly influence the deflection of the beam. When corrosion is generalized (late cracking stage), as the steel-concrete bond is already lost, the generalized steel cross-section reduction becomes the main factor affecting the beams serviceability. But, at this stage, the deflection increase is slower due to the low general corrosion rate.
The reinforced concrete structures of hydroelectric power plants and nuclear power plants differ from civil structures by their massive nature, including high cross-sections, low reinforcement percentage, and the presence of block seams. A decrease in the safety of these structures results when these features are not taken into account. Methods of calculation that take these features into account are proposed.
A numerical parametric investigation was conducted to determine the economic benefits of utilizing high-strength concrete and high-strength steel reinforcing bar (rebar) in reinforced concrete (RC) shear walls for nuclear power plant structures. Thick RC shear walls with low height-to-length aspect ratios (i.e., aspect ratios, h{sub w}/l{sub w}≤2.0, where h{sub w} is the wall height and l{sub w} is the wall length) are the most common lateral load resisting members in non-containment, safety-related nuclear structures. Typically, the walls are reinforced with multiple layers of overlapping, large-diameter vertical and horizontal rebar on each face. These heavily-reinforced walls provide large lateral stiffness and strength to prevent significant deformations and/or cracking that could compromise the integrity of the nuclear facility. However, this design adversely affects constructability as the rebar cages become highly congested. The time, labor, and materials required for this construction lead to high overall project costs. There has been a recent research thrust in the U.S. to allow high-strength rebar in non-nuclear building structures. While some of this research (e.g., steel properties, bond, anchorage) is applicable to RC structures in general, there are important differences specific to nuclear structures, such as much thicker walls (often controlled by radiation and thermal cycling), larger reinforcement ratios, and increased susceptibility to shear-controlled behavior (due to low aspect ratios). An important limiting factor for non-nuclear structures in seismic regions is the reduced deformation capacity of high-strength rebar as compared with normal-strength rebar used in current practice. Differences in seismic design philosophy lessen this limitation for nuclear structures (i.e., nuclear structures are designed more conservatively and allowed to undergo significantly smaller nonlinear displacements), making high-strength rebar a promising alternative to reinforcement currently permissible in the ACI 349-13 code requirements, which govern the design of nuclear safety-related concrete structures. To improve constructability and economy, this study investigates the benefits of using high-strength rebar [i.e., ASTM A615 Grade 550 (U.S. Grade 80); ASTM A1035 Grades 690 and 830 (U.S. Grades 100 and 120), where the grade indicates the specified yield strength of the steel in MPa (ksi)] together with high-strength concrete [compression strengths up to 138 MPa (20.0 ksi)] in RC nuclear shear walls. These strength ranges represent steel and concrete materials that are commercially available in the U.S. High-strength rebar can significantly reduce the required steel areas, thereby reducing material/fabrication costs, reducing rebar congestion (fewer/smaller bars and bar layers), and facilitating concrete consolidation and placement. Previous research on the use of high-strength rebar and/or high-strength concrete in nuclear RC structures does not exist in North America. A recent study assessed the potential of high-strength steel to reduce the rebar volume in non-nuclear building construction. In Japan, researchers investigated the use of high-strength materials in safety-related nuclear RC structures, but did not explore the economic benefits of these materials. To address this knowledge gap, the current paper describes a numerical parametric investigation on the potential cost savings of nuclear shear walls with high-strength rebar and/or concrete through comparisons against state-of-practice walls with normal-strength materials. Overall, the results demonstrate that significant economic benefits can be realized by implementing high-strength rebar and concrete in these structures. (authors)
The object of this work is to model the propagation of fracture in mixed-mode in lightly reinforced concrete beams. When a notched beam does not have enough shear reinforcement, fracture can initiate and propagate unstably and lead to failure through diagonal tension. In order to study this phenomenon numerically, a model capable of dealing with both static and dynamic crack propagation as well as the natural transition of those two regimes is necessary. We adopt a cohesive model for concrete fracture and an interface model for the deterioration between concrete and steel re-bar, both combined with an insertion algorithm. The static process is solved by dynamic relaxation (DR) method together with a modified technique to enhance convergence rate. The same DR method is used to detect a dynamic process and switch to a dynamic calculation. The numerically obtained load-displacement curves, load-CMOD curves and crack patterns fit reasonably well with their experimental counterparts, having in mind that we fed the calculations only with parameters measured experimentally.