At least 37 records · Page 2

Variable Refractive Index Effects on Radiation in Semitransparent Scattering Multilayered Regions

A simple set of equations is derived for predicting the temperature distribution and radiative energy flow in a semitransparent layer consisting of an arbitrary number of laminated sublayers that absorb, emit, and scatter radiation. Each sublayer can have a different refractive index and optical thickness. The plane composite region is heated on each exterior side by a different amount of incident radiation. The results are for the limiting case where heat conduction within the layers is very small relative to radiative transfer, and is neglected. The interfaces are assumed diffuse, and all interface reflections are included in the analysis. The thermal behavior is readily calculated from the analytical expressions that are obtained. By using many sublayers, expressions provide the temperature distribution and heat flow for a diffusing medium with a continually varying refractive index, including internal reflection effects caused by refractive index gradients. Temperature and heat flux results are given to show the effect of variations in refractive index and optical thickness through the multilayer laminate.

Siegel, R.

Variable Refractive Index Effects on Radiation in Semitransparent Scattering Multilayered Regions

A simple set of equations is derived for predicting the temperature distribution and radiative energy flow in a semitransparent layer consisting of an arbitrary number of laminated sublayers that absorb, emit, and scatter radiation. Each sublayer can have a different refractive index and optical thickness. The plane composite region is heated on each exterior side by a different amount of incident radiation. The results are for the limiting case where heat conduction within the layers is very small relative to radiative transfer, and is neglected. The interfaces are assumed diffuse, and all interface reflections are included in the analysis. The thermal behavior is readily calculated from the analytical expressions that are obtained. By using many sublayers, the analytical expressions provide the temperature distribution and heat flow for a diffusing medium with a continuously varying refractive index, including internal reflection effects caused by refractive index gradients. Temperature and heat flux results are given to show the effect of variations in refractive index and optical thickness through the multilayer laminate.

Siegel, R.

Determination of refractive index of a simple negative, positive, or zero power lens using wedged plated interferometer

A nondestructive technique for measuring the refractive index of a negative lens using a wedged plate interferometer is described. The method can be also used for measuring the refractive index of convex or zero power lenses. Schematic diagrams are presented for the use of a wedged plate interferometer for measuring the refractive index of a concave lens and of a convex lens.

Shukla, R. P.

Refractive index of plant cell walls

Air was replaced with media of higher refractive indices by vacuum infiltration in leaves of cucumber, blackeye pea, tomato, and string bean plants, and reflectance of noninfiltrated and infiltrated leaves was spectrophotometrically measured. Infiltrated leaves reflected less light than noninfiltrated leaves over the 500-2500-nm wavelength interval because cell wall-air interfaces were partly eliminated. Minimal reflectance should occur when the average refractive index of plant cell walls was matched by the infiltrating fluid. Although refractive indices that resulted in minimal reflectance differed among the four plant genera, an average value of 1.425 approximates the refractive index of plant cell walls for the four plant genera.

Gausman, H. W.

Ultraviolet complex refractive index of Martian dust Laboratory measurements of terrestrial analogs

The optical complex index of refraction of four candidate Martian surface materials has been determined between 0.185 and 0.4 microns using a modified Kubelka-Munk scattering theory. The cadidate materials were limonite, andesite, montmorillonite, and basalt. The effect of scattering has been removed from the results. Also presented are diffuse reflection and transmission data on these samples.

Egan, W. G.

Refractive Index and Scattering Effects on Radiative Behavior of a Semitransparent Layer

Heat transfer characteristics are analyzed for a plane layer of semitransparent material with refractive index not less than 1. Energy transfer in the material is by conduction, emission, absorption, and isotropic scattering. Each side of the layer is heated by radiation and convection. For a refractive index larger than unity, there is internal reflection of some of the energy within the layer. This, coupled with scattering, has a substantial effect on distributing energy across the layer and altering the temperature distribution from when the refractive index is unity. The effect of scattering is examined by comparisons with results from an earlier paper for an absorbing layer. Results are given for a gray medium with a scattering albedo up to 0.999, and for a two-band spectral variation of the albedo with one band having low absorption. Radiant energy leaving the surface as a result of emission and scattering was examined to determine if it could be used to accurately indicate the surface temperature.

Spuckler, C. M.

Cryogenic Refractive Index and Coefficient of Thermal Expansion for the S-TIH1 Glass

Using the CHARMS facility at NASA GSFC, we have measured the cryogenic refractive index of the Ohara S-TIH1 glass from 0.40 to 2.53 micrometers and from 120 to 300 K. We have also examined the spectral dispersion and thermo-optic coefficients (dn/dT). We also derived temperature-dependent Sellmeier models from which refractive index may be calculated for any wavelength and temperature within the stated ranges of each model. The S-TIH1 glass we tested exhibited unusual behavior in the thermo-optic coefficient. We found that for delta < 0.5 micrometers, the index of refraction decrease with a decrease in temperature (positive dn/dT). However, the situation was reversed for delta larger than 0.63 micrometers, where the index will increase with a decrease in temperature (negative dn/dT). We also measured the coefficient of thermal expansion (CTE) for the similar batch of S-TIH1 glass in order to understand its thermal properties. The CTE showed a monotonic change with a decrease in temperature.

Quijada, Manuel A.

High Accuracy, Absolute, Cryogenic Refractive Index Measurements of Infrared Lens Materials for JWST NIRCam using CHARMS

The current refractive optical design of the James Webb Space Telescope (JWST) Near Infrared Camera (NIRCam) uses three infrared materials in its lenses: LiF, BaF2, and ZnSe. In order to provide the instrument s optical designers with accurate, heretofore unavailable data for absolute refractive index based on actual cryogenic measurements, two prismatic samples of each material were measured using the cryogenic, high accuracy, refraction measuring system (CHARMS) at NASA GSFC, densely covering the temperature range from 15 to 320 K and wavelength range from 0.4 to 5.6 microns. Measurement methods are discussed and graphical and tabulated data for absolute refractive index, dispersion, and thermo-optic coefficient for these three materials are presented along with estimates of uncertainty. Coefficients for second order polynomial fits of measured index to temperature are provided for many wavelengths to allow accurate interpolation of index to other wavelengths and temperatures.

Leviton, Douglas

Dynamic Control of Refractive Index During Pulsed-Laser-Deposited Waveguide Growth

Engineering the optical properties of waveguides is important for the optimization of their guided optical mode characteristics. Here, we document the dynamic control of the refractive index and composition of crystalline films, via the substrate temperature, during pulsed-laser-deposition growth of Er(1%)-doped yttrium gallium garnet on <100>-orientated single-crystal yttrium aluminium garnet. An increasing substrate temperature is observed to reduce the gallium content in the grown film, with a corresponding reduction of refractive index. We demonstrate the ability to accurately control the refractive index via this technique and use it to grow a complex multi-core crystal waveguide. Our results highlight the potential of using pulsed laser deposition to fabricate crystal films with bespoke optical properties and thus engineer passive and active waveguide devices in situ.

Temperature

The Effects of Experimental Conditions on the Refractive Index and Density of Low-Temperature Ices: Solid Carbon Dioxide

We present the first study on the effects of the deposition technique on the measurements of the visible refractive index and the density of a low-temperature ice using solid carbon dioxide (CO2) at 14-70 K as an example. While our measurements generally agree with previous studies that show a dependence of index and density on temperature below 50 K, we also find that the measured values depend on the method used to create each sample. Below 50 K, we find that the refractive index varied by as much as 4% and the density by as much as 16% at a single temperature depending on the deposition method. We also show that the Lorentz-Lorenz approximation is valid for solid CO2 across the full 14-70 K temperature range, regardless of the deposition method used. Since the refractive index and density are important in calculations of optical constants and infrared (IR) band strengths of materials, our results suggest that the deposition method must be considered in cases where nvis and ρ are not measured in the same experimental setup where the IR spectral measurements are made.

planetary nebulae

Velocimetry with refractive index matching for complex flow configurations, phase 1

The feasibility of obtaining detailed velocity field measurements in large Reynolds number flow of the Space Shuttle Main Engine (SSME) main injector bowl was demonstrated using laser velocimetry and the developed refractive-index-matching technique. An experimental system to provide appropriate flow rates and temperature control of refractive-index-matching fluid was designed and tested. Test results are presented to establish the feasibility of obtaining accurate velocity measurements that map the entire field including the flow through the LOX post bundles: sample mean velocity, turbulence intensity, and spectral results are presented. The results indicate that a suitable fluid and control system is feasible for the representation of complex rocket-engine configurations and that measurements of velocity characteristics can be obtained without the optical access restrictions normally associated with laser velocimetry. The refractive-index-matching technique considered needs to be further developed and extended to represent other rocket-engine flows where current methods either cannot measure with adequate accuracy or they fail.

Thompson, B. E.

Effective medium approximation for the refractive index of stratified metal oxide composites synthesized by atomic layer deposition

Atomic layer deposition (ALD) is a unique method for synthesizing conformal layers with precise composition. It is especially useful for the synthesis of mixed metal oxides for functional materials. One application of interest is the use of ALD for tailoring the refractive index of coatings. In homogeneously distributed composites of metal oxides, the refractive properties can be approximated as the average of the indices of the components. This is known as an effective medium approximation (EMA) and can be used to design the macroscopic properties of composites. ALD produces layered, anisotropic films, so the validity of an EMA in describing these films is not clear. Here, we use optical simulations and experimental characterization of stratified composites of TiO 2 and Al 2 O 3 to study the application of an EMA to the transmission and reflection behavior of ALD-prepared mixed metal oxide thin films. We found that when the characteristic layer thickness is smaller than roughly 10 nm, the optical spectra of theoretical and experimental ALD films match the equivalent theoretical spectra for a material with a refractive index calculated from a simple, compositionally weighted EMA. Hence, this EMA could describe the transmission and reflectance spectra in ALD-derived TiO2–Al 2 O 3 nanolaminates when the films were sufficiently stratified even without thorough characterization of the real layers in the films. As a result, we demonstrated that ALD can be used to prepare effectively homogenous mixed metal oxide films with a predictable, tailorable refractive index of any value between those of the TiO 2 and Al 2 O 3 component materials.

42 ENGINEERING

Combined use of Satellite and Surface Observations to Infer the Imaginary Part of Refractive Index of Saharan Dust

We present a method for retrieval of imaginary part of refractive index of desert dust aerosol in UV part of spectrum along with aerosol layer height above the ground. The method uses Total Ozone Mapping Spectrometer' (TOMS) measurements of the top of atmosphere radiances (331 nm, 360 nm) and aerosol optical depth provided by Aerosol Robotic Network (AERONET) (440 nm). Obtained values of imaginary part of refractive index retrieved for Saharan dust aerosol at 360 nm are significantly lower than previously reported values. The average retrieved values vary between 0.0054 and 0.0066 for different geographical locations. Our findings are in good agreement with the results of several recent investigations. The time variability of retrieved values for aerosol layer height is consistent with the predictions of dust transport model.

Sinyuk, Alexander

In-Silico Analysis of High Refractive Index Materials Through Principles of Materials Design

The intent of the paper is to use specific principles of Materials Design that were developed and applied in the electronics industry for enabling understanding and design of improved high refractive index materials. Further, by combining first-principle based ab-initio, semiempirical interatomic potential methods, and machine learning approaches in conjunction with experimental data, we identified specific determinants of high refractive index materials, which can be critically applied for informing materials design and accelerating discovery. Specifically, it was demonstrated that chalcogenides and perovskites as bulk materials can exhibit higher refractive indices with appropriate engineering of specific aspects of the materials.

36 MATERIALS SCIENCE

Temperature-dependent Refractive Index of Silicon and Germanium

Silicon and germanium are perhaps the two most well-understood semiconductor materials in the context of solid state device technologies and more recently micromachining and nanotechnology. Meanwhile, these two materials are also important in the field of infrared lens design. Optical instruments designed for the wavelength range where these two materials are transmissive achieve best performance when cooled to cryogenic temperatures to enhance signal from the scene over instrument background radiation. In order to enable high quality lens designs using silicon and germanium at cryogenic temperatures, we have measured the absolute refractive index of multiple prisms of these two materials using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, as a function of both wavelength and temperature. For silicon, we report absolute refractive index and thermo-optic coefficient (dn/dT) at temperatures ranging from 20 to 300 K at wavelengths from 1.1 to 5.6 pin, while for germanium, we cover temperatures ranging from 20 to 300 K and wavelengths from 1.9 to 5.5 microns. We compare our measurements with others in the literature and provide temperature-dependent Sellmeier coefficients based on our data to allow accurate interpolation of index to other wavelengths and temperatures. Citing the wide variety of values for the refractive indices of these two materials found in the literature, we reiterate the importance of measuring the refractive index of a sample from the same batch of raw material from which final optical components are cut when absolute accuracy greater than k5 x 10" is desired.

Frey, Bradley J.

Combined Use of Satellite and Surface Observations to Infer the Imaginary Part of Refractive Index of Saharan Dust

We present a method for retrieval of the imaginary part of refractive index of desert dust aerosol in the near UV part of spectrum. The method uses Total Ozone Mapping Spectrometer (TOMS) measurements of the top of the atmosphere radiances at 331 and 360 run and aerosol optical depth provided by the Aerosol Robotic Network (AERONET). Obtained values of imaginary part of refractive index retrieved for Saharan dust aerosol at 360 nm are significantly lower than previously reported values. The average retrieved values vary between 0.0054 and 0.0066 for different geographical locations. Our findings are in good agreement with the results of several recent investigations.

Sinyuk, Alexander

Dual-mode fiber-optic refractive-index gas thermometry with primary anchoring and continuous temperature tracking

Extending fiber-optic refractive-index gas thermometry beyond primary-only operation, we report a dual-mode argon-filled Fabry-Perot thermometer in which the same cavity first establishes a primary temperature anchor and then performs continuous secondary-mode tracking. The primary anchor is obtained from two-pressure fringe shifts using a virial-coefficient refractivity model. During secondary operation, pressure cycling is stopped, and temperature is recovered from the monitored fringe wavelength and gas pressure using a model that includes argon refractivity, pressure-induced cavity strain, and fused-silica thermal expansion. From 310 to 1013 K, secondary-mode temperatures agreed with a reference thermocouple with 0.21 K RMSE and 0.47 K maximum error; 45-min natural furnace cooldowns were also tracked from nearby anchors with close agreement. The dual-mode method retains the empirical-calibration-free primary measurement as an in-situ reference while enabling simpler continuous tracking between anchors, addressing a practical limitation of primary-only fiberoptic refractive-index gas thermometry for hightemperature applications.

Syed, Musaddeque [Michigan State University, East