Preliminary design overview and performance assessment of the ITER low-field side reflectometer

The design of the ITER low-field side reflectometer (LFSR) has matured to a complete end-to-end preliminary design. LFSR will supply three key plasma measurements: (1) electron density profile, (2) electron density fluctuations, and (3) poloidal rotation. Simultaneous measurements of the three quantities are enabled by an array of six monostatic antennas which inject from an equatorial port on the outboard side of the ITER vessel. Low-loss transmission lines, consisting of corrugated, overmoded waveguide and miter bends, transmit the 30–165 GHz, O- and X-mode signals to and from the ITER plasma. Integrated transmission-line components serve a range of purposes, such as protection from high-power stray radiofrequency radiation, accommodation of transmission-line displacement, and simultaneous measurement of reference and plasma phases during the discharge. Broadband transmission signals are realized by full-band microwave transceivers combined with quasi-optical multiplexing. A field-programmable gate array (FPGA) processor demodulates the profile reflectometer signals, enabling real-time density profile measurements for plasma control system feedback. A full-scale transmission line test facility provides an integrated environment to assess the performance of critical LFSR components. Theoretical modeling together with insertion loss measurements provide the basis for a comprehensive power budget, which accounts for transmitted output power, transmission-line losses, antenna coupling, and plasma effects. Results indicate that high signal-to-noise ratios are achievable with the current design. A synthetic reflectometer model, using real design parameters and baseline ITER profiles, has been developed to estimate the return signal. With evolving microwave and data acquisition technologies, full-band, ultrafast sweeps (<1 μs) will be realizable for ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron time-of-flight reflectometer GRAINS with horizontal sample plane at the IBR-2 reactor: Possibilities and prospects

A new time-of-flight neutron reflectometer GRAINS with a horizontal sample plane (vertical scattering plane) has recently been put into operation at the pulsed reactor IBR-2 (JINR, Dubna). The scattering geometry applied makes it possible to carry out complex studies of nanostructured interfaces in solid and liquid states by measuring the specular reflectivity and the intensity of diffuse scattering of thermal neutrons from open surfaces and hidden interlayer boundaries, including solid-liquid interfaces, over a wide momentum transfer range. The classical analysis of specular reflectivity allows one to determine the scattering length density profile in the object under study in a direction perpendicular to the interface for a thickness of ~100 nm with a resolution of 1 nm. The analysis of off-specular (diffuse) neutron scattering makes it possible to characterize lateral correlations on surfaces and interlayer boundaries. The paper summarizes the first experience in the operation of the GRAINS reflectometer. The instrument characteristics are presented together with the possibilities for experiments with solid and liquid samples illustrated with simple systems. Further steps for the development of the reflectometer are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetism reflectometer study shows LiF layers improve efficiency in spin valve devices

New, more efficient materials for spin valves - a device used in magnetic sensors, random access memories, and hard disk drives - may be on the way based on research using the magnetism reflectometer at Oak Ridge National Laboratory (ORNL). Spin valve devices work by means of two or more conducting magnetic material layers that alternate their electrical resistance depending on the layers alignment. Giant magnetoresistance is a quantum mechanical effect first observed in thin film structures about 20 years ago. The effect is observed as a significant change in electrical resistance, depending on whether the magnetization of adjacent ferromagnetic layers is in a parallel or an antiparallel magnetic alignment. 'What we are doing here is developing new materials. The search for new materials suitable for injecting and transferring carriers with a preferential spin orientation is most important for the development of spintronics,' said Valeria Lauter, lead instrument scientist on the magnetism reflectometer at the Spallation Neutron Source (SNS), who collaborated on the experiment. The researchers discovered that the conductivity of such materials is improved when an organic polymer semiconductor layer is placed between the magnetic materials. Organic semiconductors are now the material of choice for future spin valve devices because they preserve spin coherence over longer times and distances than conventional semiconductors. While research into spin valves has been ongoing, research into organic semiconductors is recent. Previous research has shown that a 'conductivity mismatch' exists in spin valve systems in which ferromagnetic metal electrodes interface with such organic semiconductors as Alq3 ({pi}-conjugated molecule tris(8-hydroxy-quinoline) aluminium). This mismatch limits the efficient injection of the electrons from the electrodes at the interface with the semiconductor material. However, lithium fluoride (LiF), commonly used in light-emitting diodes, has been found to enhance the injection of electrons through the semiconductor. Researchers from the University of Alabama and ORNL used polarized neutrons at the magnetism reflectometer at SNS to investigate the electronic, magnetic, and structural properties of the electrodes in a novel system. In this system, the magnetic layers cobalt and Ni{sub 80}Fe{sub 20} are interfaced with spacer layers composed of the organic semiconductor Alq3. A coupling layer of LiF is inserted to separate the magnetized layers from the semiconductor. 'ALQ3 is an organic semiconductor material,' said Lauter. 'Normally in these systems a first magnetic layer is grown on a hard substrate so that one can get the controlled magnetic parameters. Then you grow the organic semiconductor layer, followed by another magnetic material layer, such as cobalt.' In addition to determining the effect of the LiF layers on the efficiency of the electron injection, the researchers wanted to determine the magnetic properties of the cobalt and Ni{sub 80}Fe{sub 20} as well as the interfacial properties: whether there is interdiffusion of cobalt through the LiF layer to the semiconductor, for example. The researchers used polarized neutrons at beam line 4A to probe the entire, layer-by-layer assembly of the system. 'Reflectometry with polarized neutrons is a perfect method to study thin magnetic films,' Lauter said. 'These thin films - if you put one on a substrate, you see it just like a mirror. However, this mirror has a very complicated internal multilayer structure. The neutrons look inside this complicated structure and characterize each and every interface. Due to the depth sensitivity of the method, we measure the structural and magnetic properties of each layer with the resolution of 0.5 nm. The neutron scattering results found that inserting LiF as a barrier significantly improves the quality of the interface, increasing the injection of electrons from the magnetic layer through the organic semiconductor in the spin valve and enhancing the overall properties of the system. In related work the magnetic properties of the cobalt film and the permalloy Ni{sub 80}Fe{sub 20} were characterized. Cobalt in particular needed attention, as it cannot be grown epitaxially (i.e., deposited) on an organic semiconductor film. Cobalt becomes polycrystalline or amorphous, and this affects its magnetic properties. The data from the first experiment showed that the cobalt layer in the system 'did not have typical magnetic properties,' Lauter said. 'The results showed that the cobalt had low magnetization. To improve the efficiency, the cobalt magnetization should be much higher. So this experiment helped us to improve the growth conditions and to get a cobalt layer with better magnetic properties.' In a subsequent experiment the researchers increased the magnetization of the cobalt, and a follow-up paper is in progress.

36 MATERIALS SCIENCE↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗

Experimental comparison of pyranometer, reflectometer, and spectrophotometer methods for the measurement of roofing product albedo

Albedo (solar reflectance) can be measured outdoors with a pyranometer or indoors with a hemispherical reflectometer or a spectrophotometer. The current study evaluates these methods and their applicability to roofing materials by measuring and comparing the ASTM E1918 (pyranometer), non-ASTM E1918A (alternative pyranometer), ASTM C1549 (reflectometer), and E903 (spectrophotometer) albedos of 10 roofing products, including three single-ply membranes, one asphalt shingle, three roofing aggregates, and three high-profile tiles. It uses full-size (4 m × 4 m) assemblies in the E1918 and E1918A trials; corrects the E1918 albedos to remove shadow and background errors; and evaluates C1549 and E903 albedos with two different irradiance spectra, one global horizontal and the other beam normal. E1918A albedos matched E1918 corrected (E1918_cor) albedos to within 0.036. Furthermore, agreement between C1549 air mass 1 global horizontal (C1549_G1) albedo and E1918_cor albedo was within 0.015 for membrane and shingle coupons, and within 0.031 for aggregates, though the uncertainty in the latter agreement was up to 0.043. After minor corrections, C1549_G1 albedos of flat or slightly convex tile chips were 0.032–0.052 higher than the E1918_cor albedos of their corresponding high-profile tile assemblies because high-profile surfaces have concavities. Switching to the beam-normal albedo C1549_1.5E increased the C1549 albedos of the 10 tested products by 0.004–0.054, with the largest increases (C1549_1.5E – C1549_G1) accruing to spectrally selective cool colors. Using C1549_1.5E albedo to characterize a chip of a cool-colored tile compounded the error induced by representing a high-profile surface by a flat or slightly convex specimen.

14 SOLAR ENERGY↗

Radiometric Calibration Techniques for Signal-of-Opportunity Reflectometers

Bi-static reflection measurements utilizing global navigation satellite service (GNSS) or other signals of opportunity (SoOp) can be used to sense ocean and terrestrial surface properties. End-to-end calibration of GNSS-R has been performed using well-characterized reflection surface (e.g., water), direct path antenna, and receiver gain characterization. We propose an augmented approach using on-board receiver electronics for radiometric calibration of SoOp reflectometers utilizing direct and reflected signal receiving antennas. The method calibrates receiver and correlator gains and offsets utilizing a reference switch and common noise source. On-board electronic calibration sources, such as reference switches, noise diodes and loop-back circuits, have shown great utility in stabilizing total power and correlation microwave radiometer and scatterometer receiver electronics in L-band spaceborne instruments. Application to SoOp instruments is likely to bring several benefits. For example, application to provide short and long time scale calibration stability of the direct path channel, especially in low signal-to-noise ratio configurations, is directly analogous to the microwave radiometer problem. The direct path channel is analogous to the loopback path in a scatterometer to provide a reference of the transmitted power, although the receiver is independent from the reflected path channel. Thus, a common noise source can be used to measure the gain ratio of the two paths. Using these techniques long-term (days to weeks) calibration stability of spaceborne L-band scatterometer and radiometer has been achieved better than 0.1. Similar long-term stability would likely be needed for a spaceborne reflectometer mission to measure terrestrial properties such as soil moisture.

calibrating↗

Multifrequency channel microwave reflectometer with frequency hopping operation for density fluctuation measurements in Large Helical Device

In order to measure the internal structure of density fluctuations using a microwave reflectometer, the broadband frequency tunable system, which has the ability of fast and stable hopping operation, has been improved in the Large Helical Device. Simultaneous multipoint measurement is the key issue of this development. For accurate phase measurement, the system utilizes a single sideband modulation technique. Currently, a dual channel heterodyne frequency hopping reflectometer system has been constructed and applied to the Alfven eigenmode measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization studies of the ITER low field side reflectometer

Microwave reflectometry will be used on ITER to measure the electron density profile, density fluctuations due to MHD/turbulence, edge localized mode (ELM) density transients, and as an L-H transition monitor. The ITER low field side reflectometer system will measure both core and edge quantities using multiple antenna arrays spanning frequency ranges of 15-155 GHz for the O-mode system and 55-220 GHz for the X-mode system. Optimization studies using the GENRAY ray-tracing code have been done for edge and core measurements. The reflectometer launchers will utilize the HE11 mode launched from circular corrugated waveguide. The launched beams are assumed to be Gaussian with a beam waist diameter of 0.643 times the waveguide diameter. Optimum launcher size and placement are investigated by computing the antenna coupling between launchers, assuming the launched and received beams have a Gaussian beam pattern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GINA-A polarized neutron reflectometer at the Budapest Neutron Centre

The setup, capabilities, and operation parameters of the neutron reflectometer GINA, the recently installed 'Grazing Incidence Neutron Apparatus' at the Budapest Neutron Centre, are introduced. GINA, a dance-floor-type, constant-energy, angle-dispersive reflectometer is equipped with a 2D position-sensitive detector to study specular and off-specular scattering. Wavelength options between 3.2 and 5.7 A are available for unpolarized and polarized neutrons. Spin polarization and analysis are achieved by magnetized transmission supermirrors and radio-frequency adiabatic spin flippers. As a result of vertical focusing by a five-element pyrolytic graphite monochromator, the reflected intensity from a 20 Multiplication-Sign 20 mm{sup 2} sample has been doubled. GINA is dedicated to studies of magnetic films and heterostructures, but unpolarized options for non-magnetic films, membranes, and other surfaces are also provided. Shortly after its startup, reflectivity values as low as 3 Multiplication-Sign 10{sup -5} have been measured by the instrument. The instrument capabilities are demonstrated by a non-polarized and a polarized reflectivity experiment on a Si wafer and on a magnetic film of [{sup 62}Ni/{sup nat}Ni]{sub 5} isotope-periodic layer composition. The facility is now open for the international user community. Its further development is underway establishing new sample environment options and spin analysis of off-specularly scattered radiation as well as further decreasing the background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SuperADAM: Upgraded polarized neutron reflectometer at the Institut Laue-Langevin

A new neutron reflectometer SuperADAM has recently been built and commissioned at the Institut Laue-Langevin, Grenoble, France. It replaces the previous neutron reflectometer ADAM. The new instrument uses a solid state polarizer/wavelength filter providing a highly polarized (up to 98.6%) monochromatic neutron flux of 8 Multiplication-Sign 10{sup 4} n cm{sup -2} s{sup -1} with monochromatization {Delta}{lambda}/{lambda}= 0.7% and angular divergence {Delta}{alpha}= 0.2 mrad. The instrument includes both single and position sensitive detectors. The position sensitive detector allows simultaneous measurement of specular reflection and off-specular scattering. Polarization analysis for both specular reflection and off-specular scattering is achieved using either mirror analyzers or a {sup 3}He spin filter cell. High efficiency detectors, low background, and high flux provides a dynamic range of up to seven decades in reflectivity. Detailed specifications and the instrument capabilities are illustrated with examples of recently collected data in the fields of thin film magnetism and thin polymer films.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of frequency modulation reflectometer for Korea Superconducting Tokamak Advanced Research tokamak

Frequency modulation reflectometer has been developed to measure the plasma density profile of the Korea Superconducting Tokamak Advanced Research tokamak. Three reflectometers are operating in extraordinary polarization mode in the frequency range of Q band (33.6–54 GHz), V band (48–72 GHz), and W band (72–108 GHz) to measure the density up to 7 × 10{sup 19} m{sup −3} when the toroidal magnetic field is 2 T on axis. The antenna is installed inside of the vacuum vessel. A new vacuum window is developed by using 50 μm thick mica film and 0.1 mm thick gold gasket. The filter bank of low pass filter, notch filter, and Faraday isolator is used to reject the electron cyclotron heating high power at attenuation of 60 dB. The full frequency band is swept in 20 μs. The mixer output is directly digitized with sampling rate of 100 MSamples/s. The phase is obtained by using wavelet transform. The whole hardware and software system is described in detail and the measured density profile is presented as a result.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance and data analysis aspects of the new DIII-D monostatic profile reflectometer system

A new frequency-modulated profile reflectometer system, featuring a monostatic antenna geometry (using one microwave antenna for both launch and receive), has been installed on the DIII-D tokamak, providing a first experimental test of this measurement approach for profile reflectometry. Significant features of the new system are briefly described in this paper, including the new monostatic arrangement, use of overmoded, broadband transmission waveguide, and dual-polarization combination/demultiplexing. Updated data processing and analysis, and in-service performance aspects of the new monostatic profile reflectometer system are also presented. By using a raytracing code (GENRAY) to determine the approximate trajectory of the probe beam, the electron density (n{sub e}) profile can be successfully reconstructed with L-mode plasmas vertically shifted by more than 10 cm off the vessel midplane. Specifically, it is demonstrated that the new system has a capability to measure n{sub e} profiles with plasma vertical offsets of up to ±17 cm. Examples are also presented of accurate, high time and spatial resolution density profile measurements made over a wide range of DIII-D conditions, e.g., the measured temporal evolution of the density profile across a L-H transition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2D microwave imaging reflectometer electronics

A 2D microwave imaging reflectometer system has been developed to visualize electron density fluctuations on the DIII-D tokamak. Simultaneously illuminated at four probe frequencies, large aperture optics image reflections from four density-dependent cutoff surfaces in the plasma over an extended region of the DIII-D plasma. Localized density fluctuations in the vicinity of the plasma cutoff surfaces modulate the plasma reflections, yielding a 2D image of electron density fluctuations. Details are presented of the receiver down conversion electronics that generate the in-phase (I) and quadrature (Q) reflectometer signals from which 2D density fluctuation data are obtained. Also presented are details on the control system and backplane used to manage the electronics as well as an introduction to the computer based control program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Doppler reflectometer for KSTAR

A Doppler reflectometer has been designed to measure the poloidal propagation velocity on the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. It has the operating frequency range of V-band (50-75 GHz) and the monostatic antenna configuration with extraordinary mode (X-mode). The single sideband modulation with an intermediate frequency of 50 MHz is used for the heterodyne measurement with the 200 MHz in-phase and quadrature (I/Q) phase detector. The corrugated conical horn antenna is used to approximate the Gaussian beam propagation and it is installed together with the oversized rectangular waveguides in the vacuum vessel. The first commissioning test of the Doppler reflectometer system on the KSTAR tokamak is planned in the 2014 KSTAR experimental campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Survey and adjustment methods applied on an 11 axes high performance reflectometer for synchrotron radiation

At BESSY-II a new UV-and XUV optics beamline [1] has recently been setup with an in-house developed versatile reflectometer [2], [3], [4] for at-wavelength metrology on reflective and diffractive optical elements up to 4 kg mass. High precision measurements of the reflection and polarization properties are feasible by a 360° azimuthal rotation of the sample around the beam of light, where samples can be adjusted reproducibly with a novel UHV-Tripod within arc sec and μm precision. The azimuthal rotation requires an extremely high precision adjustment of the goniometer axis with respect to the incident light beam. Here we describe sophisticated methods with which we achieve nearly perfect agreement of the azimuthal rotation axis and the synchrotron beam in the 30 arc sec range. By using geodetic instruments (lasertracker, theodolite, autocollimator) the quality of the reflectometer UHV-mechanics has been characterized with respect to stiffness and radial run out with highest precision [5].

43 PARTICLE ACCELERATORS↗

Design of a correlation reflectometer radiometer diagnostic and measurements of the electron density–temperature cross-phase angle in the H-mode pedestal with small edge localized modes at ASDEX Upgrade

This work presents the hardware design and first results from a newly commissioned correlation reflectometer radiometer diagnostic that measures the cross-phase angle between electron density and temperature fluctuations in ASDEX Upgrade plasmas. This diagnostic employs cross correlations between signals measured by a tunable, continuous wave, perpendicular incidence, fluctuation reflectometer, and a 24-channel radiometer sharing the same line of sight. Novel measurements in the pedestal of a helium H-mode plasma with small edge localized modes show changes in the cross-phase angle between the electron density and temperature fluctuations from ∼90° to 120°, suggesting changes in the properties of the turbulence driving transport in the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real time reflectometer

A real time reflectometer with the particular utility of measuring fairly rapid (transient) changes in the specular reflectance of a sample which is continuously exposed to a perturbing environment is described. A fixed radiation source, a fixed detector, a uniformly rotating sample wheel, and a uniformly rotating optical wheel protect against misalignment problems. The reflectometer operates by comparing the measurings of a reflected signal with that of a reference signal made within fractions of a second of one another. Reflectance is measured in the infrared, visible, and vacuum ultraviolet regions.

Zwiener, J. M.↗

Microwave reflectometer ionization sensor

The development of the Microwave Reflectometer Ionization Sensor (MRIS) Instrument for use on the Aeroassist Flight Experiment (AFE) spacecraft is described. The instrument contract was terminated, due to cancellation of the AFE program, subsequent to testing of an engineering development model. The MRIS, a four-frequency reflectometer, was designed for the detection and location of critical electron density levels in spacecraft reentry plasmas. The instrument would sample the relative magnitude and phase of reflected signals at discrete frequency steps across 4 GHz bandwidths centered at four frequencies: 20, 44, 95, and 140 GHz. The sampled data would be stored for later processing to calculate the distance from the spacecraft surface to the critical electron densities versus time. Four stepped PM CW transmitter receivers were located behind the thermal protection system of the spacecraft with horn antennas radiating and receiving through an insulating tile. Techniques were developed to deal with interference, including multiple reflections and resonance effects, resulting from the antenna configuration and operating environment.

Seals, Joseph↗