Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REACTOR SIMULATORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Laser-induced breakdown spectroscopy of light water reactor simulated used nuclear fuel: Main oxide phase

We show the analysis of light water reactor simulated used nuclear fuel using laser-induced breakdown spectroscopy (LIBS) is explored using a simplified version of the main oxide phase. The main oxide phase consists of the actinides, lanthanides, and zirconium. The purpose of this study is to develop a rapid, quantitative technique for measuring zirconium in a uranium dioxide matrix without the need to dissolve the material. A second set of materials including cerium oxide is also analyzed to determine precision and limit of detection (LOD) using LIBS in a complex matrix. Two types of samples are used in this study: binary and ternary oxide pellets. The ternary oxide, (U,Zr,Ce)O 2 pellets used in this study are a simplified version the main oxide phase of used nuclear fuel. The binary oxides, (U,Ce)O 2 and (U,Zr)O 2 are also examined to determine spectral emission lines for Ce and Zr, potential spectral interferences with uranium and baseline LOD values for Ce and Zr in a UO 2 matrix. In the spectral range of 200 to 800 nm, 33 cerium lines and 25 zirconium lines were identified and shown to have linear correlation values (R 2 ) > 0.97 for both the binary and ternary oxides. The cerium LOD in the (U,Ce)O 2 matrix ranged from 0.34 to 1.08 wt% and 0.94 to 1.22 wt% in (U,Ce,Zr)O 2 for 33 of Ce emission lines. The zirconium limit of detection in the (U,Zr)O 2 matrix ranged from 0.84 to 1.15 wt% and 0.99 to 1.10 wt% in (U,Ce,Zr)O 2 for 25 Zr lines. Finally, the effect of multiple elements in the plasma and the impact on the LOD is discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Planned Destruction of Metal-Core Reactor: Simulation of Catastrophic Accidents and New Experimental Possibilities

A reactor with a destructible core (RIR reactor) generating a pulse with an output of ~1.5 × 10{sup 19} fissions and a full width at half maximum of ~2.5 μs was developed and tested at VNIIEF. In the course of investigation, a computational-experimental method for laboratory calibration of the reactor was created and worked out. This method ensures a high accuracy of predicting the energy release in a real experiment with excess reactivity of ~3β{sub eff} above prompt criticality. A transportable explosion-proof chamber was also developed, which ensures the safe localization of explosion products of the core of small-sized nuclear devices and charges of high explosives with equivalent mass of up to 100 kg of TNT.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reactor Simulator Testing

As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator test loop (RxSim) was design & built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing was to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V since the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This paper summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. The annular linear induction pump (ALIP) tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz. Keywords: fission, space power, nuclear, liquid metal, NaK.

Schoenfeld, Michael P.↗

Reactor Simulator Testing

As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator test loop (RxSim) was design & built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing was to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V since the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This paper summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. The annular linear induction pump (ALIP) tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.

Schoenfeld, Michael P.↗

Reactor Simulator Testing

As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator test loop (RxSim) was design & built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing was to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V since the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This paper summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. The annular linear induction pump (ALIP) tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.

Schoenfeld, Michael P.↗

Reactor Simulator Integration and Testing

As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator (RxSim) test loop was designed and built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing were to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V because the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This Technical Memorandum summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained, which was lower than the predicted 750 K but 156 K higher than the cold temperature, indicating the design provided some heat regeneration. The annular linear induction pump tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.

Schoenfield, M. P.↗

Physics-Based Multi-State Models of Passive Component Degradation for the R7 Reactor Simulation Environment

Abstract: The Next Generation Systems Analysis Code - referred to as R7 - is reactor systems simulation software being developed to support the Risk-Informed Safety Margin Characterization Pathway of the U.S. Department of Energy's Light Water Reactor Sustainability Program. It will provide an integrated multi-physics environment, implemented in an uncertainty quantification (UQ) framework that can produce risk and other performance insights on long-term reactor operations. An element of this simulation environment will be the performance of passive components and materials. Conventional models of component reliability are largely parametric, relying on plant service data to estimate component lifetimes and failure rates. This type of model has limited usefulness in the R7 environment where the intent is to explicitly determine the influence of physical stressors on component degradation. In this paper, we describe a new class of multi-state physics-based component models designed to be R7-compatible. These models capture the physics of materials degradation while also incorporating the effects of interventions and component rejuvenation. The models are implemented in a cumulative damage framework that allows the impact of an evolving physical environment to be addressed without recourse to resampling within the Monte Carlo-based UQ framework. The paper describes an application to stress corrosion cracking in dissimilar metal welds - a principal contributor to potential loss of coolant accidents. So while R7 will have the more conventional capability of reactor simulation codes to model the impact of degraded components and systems on plant performance, the methodology described here allows R7 to model the inverse effect; the impact of the physical environment on component degradation and performance.

PRA, passive components, stress corrosion cracking↗

Micro Reactor Simulation Using the PROTEUS Suite in FY19

Two micro reactor cores were simulated using the MOC solver of PROTEUS: MegaPower for a heat pipe micro reactor and Holos-Quad for a high-temperature gas-cooled micro reactor. Verification of PROTEUS standalone was performed by simulating 2D and 3D core benchmark problems developed based on MegaPower and Holos-Quad. Simulation results indicated that PROTEUS successfully modelled 2D and 3D cores of the MegaPower and Holos-Quad micro reactors and PROTEUS eigenvalues agreed well with the SERPENT Monte Carlo solutions. For a heat pipe cooled micro reactor, multiphysics simulations were performed using PROTEUS / FLUENT / ANLHTP. The coupling system of the three codes were developed using Python-based drivers, which exchange the data (power, temperature, and heat rate) required for the coupling and control the boundary conditions of FLUENT and ANLHTP. The coupled system was qualitatively verified using a 3D unit assembly problem composed of six fuel rods and seven heat pipes, which was developed based on the MegaPower compositions. The steady-state problem was solved using FLUENT / ANLHTP with given asymmetric fuel powers, demonstrating the reasonable convergence of temperatures of 7 heat pipes. Transient simulations were also performed by making one out of 7 heat pipes fail. For the transient, the coupled system of PROTEUS / FLUENT / ANLHTP demonstrated reasonable changes of total power and heat pipe temperatures with time, accounting for temperature feedback effects. In this simulation, no effect of structural change was accounted for, which will be performed using ANSYS-mechanical in future along with further verification with larger or whole-core 3D problems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of adaptive hierarchical sparse grid collocation to the uncertainty quantification of nuclear reactor simulators

Recent efforts in the application of uncertainty quantification to nuclear systems have utilized methods based on generalized perturbation theory and stochastic sampling. While these methods have proven to be effective they both have major drawbacks that may impede further progress. A relatively new approach based on spectral elements for uncertainty quantification is applied in this paper to several problems in reactor simulation. Spectral methods based on collocation attempt to couple the approximation free nature of stochastic sampling methods with the determinism of generalized perturbation theory. The specific spectral method used in this paper employs both the Smolyak algorithm and adaptivity by using Newton-Cotes collocation points along with linear hat basis functions. Using this approach, a surrogate model for the outputs of a computer code is constructed hierarchically by adaptively refining the collocation grid until the interpolant is converged to a user-defined threshold. The method inherently fits into the framework of parallel computing and allows for the extraction of meaningful statistics and data that are not within reach of stochastic sampling and generalized perturbation theory. This paper aims to demonstrate the advantages of spectral methods-especially when compared to current methods used in reactor physics for uncertainty quantification-and to illustrate their full potential. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Inverse Uncertainty Quantification of Reactor Simulation with Polynomial Chaos Surrogate Model

Reliable uncertainty quantification (UQ) and sensitivity analysis (SA) is significant part of modelling and simulation. This is particularly important in the nuclear community due to the fact that the licensing of nuclear installations has shifted from conservative to Best Estimate plus Uncertainty (BEPU) methodologies. UQ can be broadly classified as forward UQ and inverse UQ. Forward UQ is the process of quantifying the uncertainties in simulation outputs by propagating the uncertainties in input parameters. It requires knowledge in the input uncertainty, which is often specified by ad-hoc expert judgment which lacks mathematical rigor. The inverse UQ is the process to determine the uncertainty in input parameters given observations of the output. The purpose of this paper is to replace such ad-hoc expert judgment of the statistical properties of input model parameters in nuclear reactor simulation. This summary presents work on inverse UQ of a nonlinear Point Reactor Kinetics Equations - lumped thermal-hydraulics parameter coupled problem. Bayesian inference and Markov Chain Monte Carlo (MCMC) are used for the inverse UQ. Because MCMC requires a large number of simulations which is impractical for models that are computationally expensive, surrogate models is constructed by generalized Polynomial Chaos (PC) expansion technique. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutronic/Thermalhydraulic Coupling Technigues for Sodium Cooled Fast Reactor Simulations

The objective of this project was to test new coupling algorithms and enable efficient and scalable multi-physics simulations of advanced nuclear reactors, with considerations regarding the implementation of such algorithms in massively parallel environments. Numerical tests were carried out to verify the proposed approach and the examples included some reactor transients. The project was directly related to the Sodium Fast Reactor program element of the Generation IV Nuclear Energy Systems Initiative and the Advanced Fuel cycle Initiative, and, supported the requirement of high-fidelity simulation as a mean of achieving the goals of the presidential Global Nuclear Energy Partnership (GNEP) vision.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pressure Loss Predictions of the Reactor Simulator Subsystem at NASA GRC

Testing of the Fission Power System (FPS) Technology Demonstration Unit (TDU) is being conducted at NASA GRC. The TDU consists of three subsystems: the Reactor Simulator (RxSim), the Stirling Power Conversion Unit (PCU), and the Heat Exchanger Manifold (HXM). An Annular Linear Induction Pump (ALIP) is used to drive the working fluid. A preliminary version of the TDU system (which excludes the PCU for now), is referred to as the RxSim subsystem and was used to conduct flow tests in Vacuum Facility 6 (VF 6). In parallel, a computational model of the RxSim subsystem was created based on the CAD model and was used to predict loop pressure losses over a range of mass flows. This was done to assess the ability of the pump to meet the design intent mass flow demand. Measured data indicates that the pump can produce 2.333 kg/sec of flow, which is enough to supply the RxSim subsystem with a nominal flow of 1.75 kg/sec. Computational predictions indicated that the pump could provide 2.157 kg/sec (using the Spalart-Allmaras turbulence model), and 2.223 kg/sec (using the k- turbulence model). The computational error of the predictions for the available mass flow is -0.176 kg/sec (with the S-A turbulence model) and -0.110 kg/sec (with the k-epsilon turbulence model) when compared to measured data.

Turbulence Models↗

Multi-Physics Demonstration Problem with the SHARP Reactor Simulation Toolkit

This report describes to employ SHARP to perform a first-of-a-kind analysis of the core radial expansion phenomenon in an SFR. This effort required significant advances in the framework Multi-Physics Demonstration Problem with the SHARP Reactor Simulation Toolkit used to drive the coupled simulations, manipulate the mesh in response to the deformation of the geometry, and generate the necessary modified mesh files. Furthermore, the model geometry is fairly complex, and consistent mesh generation for the three physics modules required significant effort. Fully-integrated simulations of a 7-assembly mini-core test problem have been performed, and the results are presented here. Physics models of a full-core model of the Advanced Burner Test Reactor have also been developed for each of the three physics modules. Standalone results of each of the three physics modules for the ABTR are presented here, which provides a demonstration of the feasibility of the fully-integrated simulation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗