Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REACTOR INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗

Nuclear Science Symposium, 27th, and Symposium on Nuclear Power Systems, 12th, Orlando, Fla., November 5-7, 1980, Proceedings

Advances in instrumentation for use in nuclear-science studies are described. Consideration is given to medical instrumentation, computerized fluoroscopy, environmental instrumentation, data acquisition techniques, semiconductor detectors, microchannel plates and photomultiplier tubes, reactor instrumentation, neutron detectors and proportional counters, and space instrumentation.

Martini, M.↗

Radiation Resistance of XLPE Nano-dielectrics for Advanced Reactor Applications

Recently there has been renewed interest in nuclear reactor safety, particularly as commercial reactors are approaching 40 years service and lifetime extensions are considered, as well as for new reactor building projects around the world. The materials that are currently used in cabling for instrumentation, reactor control, and communications include cross-linked polyethylene (XLPE), ethylene propylene rubber (EPR), polyvinyl chloride (PVC), neoprene, and chlorosulfonated polyethylene. While these materials show suitable radiation tolerance in laboratory tests, failures before their useful lifetime occur due to the combined environmental effects of radiation, temperature and moisture, or operation under abnormal conditions. In addition, the extended use of commercial reactors beyond their original service life places a greater demand on insulating materials to perform beyond their current ratings in these nuclear environments. Nanocomposite materials that are based on XLPE and other epoxy resins incorporating TiO2, MgO, SiO2, and Al2O3 nanoparticles are being fabricated using a novel in-situ method established at ORNL to demonstrate materials with increased resistance to radiation. As novel nanocomposite dielectric materials are developed, characterization of the non-irradiated and irradiated nanodielectrics will lead to a knowledge base that allow for dielectric materials to be engineered with specific nanoparticle additions for maximum benefit to wide-variety of radiation environments found in nuclear reactors. This paper presents the initial findings on the development of XLPE-based SiO2 nano-composite dielectrics in the context of electrical performance and radiation degradation.

dielectrics↗

Silicon Carbide Sensors and Electronics Technology for Extreme Environments: Opportunities for Nuclear Power Applications

Over the past five decades, NASA Glenn Research Center had been advancing the development of single crystal silicon carbide growth, sensors and electronics device technologies, culminating in the recent demonstration of Micro-Electro-Mechanical Systems scale batch fabricated pressure sensors operating at 800 °C and integrated circuit electronics with demonstrated durability of over 1000 hours at 500 °C. As a result of the progress made in demonstrating the high temperature capability of the technology, insertion into actual operational environments, such as in jet engines and planet Venus, are in progress. The high temperature, near inert surface chemistry, and radiation hardness attributes of SiC, coupled with the relative maturation of the device batch microfabrication, contact metallization, and packaging technologies, make the material a prime candidate for use as part of future advanced nuclear reactor instrumentation and control strategy. Hence the current research efforts at NASA Glenn are aimed toward harnessing these attributes in developing SiC sensors and electronics for nuclear reactor applications, potentially for future Lunar/Martian nuclear power and the emerging terrestrial micro nuclear power plants.

silicon carbide↗

Burn coal cleanly in a fluidized bed - The key is in the controls

The fluidized-bed combustion (FBC) process produces few sulfur emissions, and can burn wood, municipal solid waste as well as every kind of coal available in the U.S. The presurized, coal-burning fluidized-bed reactor at NASA's Lewis Research Center is described, together with a discussion of the operating results. The FBC system at Lewis, having a completely instrumented reactor, is used to test turbine blade alloys for future power plant applications. With the same type of coal and limestone used in the first testing phase covering 136 hours, it was found that all NOx values were below the EPA standard of 0.7 lb/MBtu, whereas the maximum observed level of SO2 was above the EPA standard of 1.3 lb/MBtu, but with the average SO2 level, however, only 0.63 lb/MBtu. Unburned hydrocarbon and CO levels were very low, indicating combustion efficiencies of close to 99% in almost all tests. Testing is now underway using high temperature cyclones and gas turbine to eliminate erosion and corrosion effects which were observed after the initial tests on the turbine and blades.

Kobak, J. A.↗

Nuclear Science Symposium, 4th, and Nuclear Power Systems Symposium, 9th, San Francisco, Calif., October 19-21, 1977, Proceedings

Consideration is given to the following types of high energy physics instrumentation: drift chambers, multiwire proportional chambers, calorimeters, optical detectors, ionization and scintillation detectors, solid state detectors, and electronic and digital subsystems. Attention is also paid to reactor instrumentation, nuclear medicine instrumentation, data acquisition systems for nuclear instrumentation, microprocessor applications in nuclear science, environmental instrumentation, control and instrumentation of nuclear power generating stations, and radiation monitoring. Papers are also presented on instrumentation for the High Energy Astronomy Observatory.

Source record↗

Radiation-Hardened Instrumentation, Sensors and Electronics

To assist the US Department of Energy in defining a course for Office of Nuclear Energy–funded radiation-hardened (rad-hard) electronics research, Oak Ridge National Laboratory (ORNL) will focus on three main tasks in FY21. The first task will investigate the survivability of silicon junction-gate field-effect transistors (Si-JFETs) through a 100 Mrad total ionizing dose (TID) experiment and report the test results. The second task will investigate wide bandgap (WBG)-based JFET devices and sources. The third task is an investigation into commercially available systems and components and will be performed to determine whether a standardized list of devices can be identified for reactor instrumentation application. If the devices are feasible, then this list will provide direction to designers and equipment suppliers for selection of components to meet specific reactor requirements.

42 ENGINEERING↗

Raman Spectroscopy

Raman spectroscopy is one of the mostly utilized optical spectroscopic tools for revealing both the catalyst structure and surface chemistry in heterogeneous catalysis. It has recently seen increasing role in catalysis research, thanks to the development of new Raman instrumentations, reactors, and combination with other techniques, leading to in situ and operando studies with significant temporal and spatial resolutions. This chapter aimed to provide a general overview of the applications of Raman spectroscopy in heterogeneous catalysis. It starts with an introduction to the fundamentals of Raman scattering including theory and pros and cons for catalysis research; followed by a description of the typical setup of a Raman system and recent advances in Raman instrumentations; then a chronology of the applications of Raman spectroscopy for ex situ, in situ, and operando studies of catalysis; elucidations of the advances in improving the temporal and spatial resolution of Raman spectroscopy of catalysis; Raman application case studies related to catalyst synthesis, treatments, and function under reaction conditions; illustrations of the power of multimodal approach including Raman spectroscopy in catalysis research; and ended with a brief summary and a future outlook.

Braatz, Jisue↗

Raman Spectroscopy

Raman spectroscopy is one of the mostly utilized optical spectroscopic tools for revealing both the catalyst structure and surface chemistry in heterogeneous catalysis. It has recently seen increasing role in catalysis research, thanks to the development of new Raman instrumentations, reactors, and combination with other techniques, leading to in situ and operando studies with significant temporal and spatial resolutions. This chapter aimed to provide a general overview of the applications of Raman spectroscopy in heterogeneous catalysis. It starts with an introduction to the fundamentals of Raman scattering including theory and pros and cons for catalysis research; followed by a description of the typical setup of a Raman system and recent advances in Raman instrumentations; then a chronology of the applications of Raman spectroscopy for ex situ, in situ, and operando studies of catalysis; elucidations of the advances in improving the temporal and spatial resolution of Raman spectroscopy of catalysis; Raman application case studies related to catalyst synthesis, treatments, and function under reaction conditions; illustrations of the power of multimodal approach including Raman spectroscopy in catalysis research; and ended with a brief summary and a future outlook.

Braatz, Jisue↗

In-Rod Sensor System Overview, Benefits and Recent Irradiation Test Results

Westinghouse is developing an In-Rod Sensor (IRS) System capable of measuring critical fuel rod parameters such as center-line fuel temperature, rod internal pressure and axial fuel pellet stack elongation without having penetrations to the fuel rod. The technology is similar to the Halden Reactor instrumentation, but the IRS system focuses on commercial fuel rod instrumentation. Both systems circumvent fuel rod penetrations, however the IRS system overcomes unique geometric challenges found in commercial fuel rod assemblies. The IRS could also play a key role in accelerated fuel qualification by allowing real-time measurements during separate effects tests, integral fuel testing or during irradiation of lead test rods or lead test assemblies. Combining these measurements with data acquired from targeted separate effects testing and multi-scale modelling could significantly reduce the time required to qualify new fuel and reduce the safety margin uncertainty of operating plants. The IRS is actively in development for Light Water Reactors (LWR) based fuel assemblies but can also be applied to Gen IV reactor designs with minimal modifications.

Carvajal, Jorge↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Systems and methods for harvesting and storing materials produced in a nuclear reactor

Systems produce desired isotopes through irradiation in nuclear reactor instrumentation tubes and deposit the same in a robust facility for immediate shipping, handling, and/or consumption. Irradiation targets are inserted and removed through inaccessible areas without plant shutdown and placed in the harvesting facility, such as a plurality of sealable and shipping-safe casks and/or canisters. Systems may connect various structures in a sealed manner to avoid release of dangerous or unwanted matter throughout the nuclear plant, and/or systems may also automatically decontaminate materials to be released. Useable casks or canisters can include plural barriers for containment that are temporarily and selectively removable with specially-configured paths inserted therein. Penetrations in the facilities may limit waste or pneumatic gas escape and allow the same to be removed from the systems without over-pressurization or leakage. Methods include processing irradiation targets through such systems and securely delivering them in such harvesting facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Accurate nine-decade temperature-compensated logarithmic amplifier

Transistor-driven temperature-stable amplifier with logarithmic operating characteristics permits presentation of the entire range of the reactor without range switching. This circuit is capable of monitoring ion chamber currents over spans of 8 or 9 decades and is used in nuclear reactor instrumentation. Application is found in materials under ultrahigh vacuum.

Bobis, J. P.↗

Radiocarbon tracer measurements of atmospheric hydroxyl radical concentrations

The usefulness of the C-14 tracer in measurements of atmospheric hydroxyl radical concentration is discussed. The apparatus and the experimental conditions of three variations of a radiochemical method of atmosphere analysis are described and analyzed: the Teflon bag static reactor, the flow reactor (used in the Wallops Island tests), and the aircraft OH titration reactor. The procedure for reduction of the aircraft reactor instrument data is outlined. The problems connected with the measurement of hydroxyl radicals are discussed. It is suggested that the gas-phase radioisotope methods have considerable potential in measuring tropospheric impurities present in very low concentrations.

Campbell, M. J.↗

SP-100 space reactor power system for lunar, Mars, and robotic exploration

The SP-100 power system is described which was developed for three missions, namely, Pluto Orbiter with nuclear electric propulsion; human-rated surface reactor power system for lunar and Mars exploration; and earth surveillance with an integrated nuclear electric propulsion system. The reactor power systems technology is being developed to meet these requirements so that the technical database, design tools, and specifications will be applicable to these missions. The SP-100 power system design includes the following subsystems: reactor, reactor instrumentation and control, shield, heat transport, converter, heat rejection, power conditioning control and distribution, and mechanical/structural. Particular attention is given to a demonstration mission aimed at validating technology readiness for robotic, lunar, and Mars operational missions.

Mondt, Jack F.↗

Radiation and temperature effects on electronic components investigated under the CSTI high capacity power project

The effects of nuclear radiation and high temperature environments must be fully known and understood for the electronic components and materials used in both the Power Conditioning and Control subsystem and the reactor Instrumentation and Control subsystem of future high capacity nuclear space power systems. This knowledge is required by the designer of these subsystems in order to develop highly reliable, long-life power systems for future NASA missions. A review and summary of the experimental results obtained for the electronic components and materials investigated under the power management element of the Civilian Space Technology Initiative (CSTI) high capacity power project are presented: (1) neutron, gamma ray, and temperature effects on power semiconductor switches, (2) temperature and frequency effects on soft magnetic materials; and (3) temperature effects on rare earth permanent magnets.

Schwarze, Gene E.↗

Development of Instrumented Advanced Test Reactor Irradiation Capsule Experiment for In-situ Thermal Conductivity Measurements of High-Density Fuels

Idaho National Laboratory (INL) is developing a first-of-a-kind leadout instrumented capsule experiment design to enable in-situ measurement capabilities in the Advanced Test Reactor (ATR) core. The Ceramic Advanced Thermal Evolution Research (CRATER) experiment supports the aLEU program objective to accelerate fuel performance irradiation testing for identifying alternative high-assay, low enriched uranium (HALEU) fuel systems. CRATER is a fueled, instrumented capsule experiment to measure in-situ temperature and thermal conductivity of ceramic fuels. Two ceramic fuel types will be used, uranium mono-nitride (UN) and uranium mono-carbide (UC), with a third metallic fuel used for comparison (UMo). The three fuel specimens will use a stainless-steel cladding. Programmatic objectives include linear heat generation rates (LHGR) of 210 ± 25 Watts per cm. and an inner clad temperature of 300-450 °C. The evolution of fuel thermal conductivity during irradiation has never been successfully measured in-situ for these systems and this experiment is designed to use advances in measurement sciences to characterize how thermal transport properties evolve while in reactor. Neutronic simulations of the experiment and its surrounding reactor environment were conducted using the Monte Carlo N-Particle Transport code (MCNP) and result in optimized fuel enrichment to meet target linear heat generation rates (LHGRs) influencing fuel temperatures, and fuel burnup requirements. Fabrication research and development (R&D) efforts are underway to produce annular right cylinder UC and UN pellets using carbothermic reduction and nitridation (or hydride-dehydride-nitride) synthesis methods, followed double-action die cold isostatic pressing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High intensity multi beam design of SANS instrument for Dhruva reactor

A new and versatile design of Small Angle Neutron Scattering (SANS) instrument based on utilization of multi-beam is presented. The multi-pinholes and multi-slits as SANS collimator for medium flux Dhruva rearctor have been proposed and their designs have been validated using McStas simulations. Various instrument configurations to achieve different minimum wave vector transfers in scattering experiments are envisioned. These options enable smooth access to minimum wave vector transfers as low as ~ 6×10{sup −4} Å{sup −1} with a significant improvement in neutron intensity, allowing faster measurements. Such angularly well defined and intense neutron beam will allow faster SANS studies of agglomerates larger than few tens of nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗