Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RANDOM ERROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mean and Random Errors of Visual Roll Rate Perception from Central and Peripheral Visual Displays

A large number of roll rate stimuli, covering rates from zero to plus or minus 25 deg/sec, were presented to subjects in random order at 2 sec intervals. Subjects were to make estimates of magnitude of perceived roll rate stimuli presented on either a central display, on displays in the peripheral ield of vision, or on all displays simultaneously. Response was by way of a digital keyboard device, stimulus exposition times were varied. The present experiment differs from earlier perception tasks by the same authors in that mean rate perception error (and standard deviation) was obtained as a function of rate stimulus magnitude, whereas the earlier experiments only yielded mean absolute error magnitude. Moreover, in the present experiment, all stimulus rates had an equal probability of occurrence, whereas the earlier tests featured a Gaussian stimulus probability density function. Results yield a ood illustration of the nonlinear functions relating rate presented to rate perceived by human observers or operators.

Vandervaart, J. C.↗

Effect of roughness, deterministic and random errors in film thickness on the reflecting properties of aperiodic mirrors for the EUV range

By the example of three aperiodic multilayer Mo/Si mirrors (AMM) for the wavelength ranges 17–21 nm, 24–29 nm, and 28–33 nm we have studied numerically the effect of the linearly determinisctic and random fluctuations of the film thickness and the interlayer roughness on the spectral dependences of the reflection coefficient. The simulation results are used to solve the inverse problem of reconstructing the interlayer roughness and the thickness of individual films from the measured dependences of the extreme UV radiation reflection coefficients. It is shown that the 'asymmetry' of the boundaries affects the magnitude and slope of the reflection coefficient plateau. Random fluctuations of the film thickness with the variance of 1%–2% weakly influence the reflection characteristics of AMMs and allow reliable reconstruction of the thickness of individual films. The fluctuations with the variance 8%–10% allow the estimation of individual thicknesses, but the reflection curve in this case strongly differs from the desirable one. Larger fluctuations do not allow the reconstruction of the AMM structure. The basic criteria for high-quality AMM synthesis are formulated. (extreme laser radiation: physics and fundamental applications)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy

Purpose: To investigate the applicability of 3-dimensional (3D) surface imaging for image guidance in deep-inspiration breath-hold radiation therapy (DIBH-RT) for patients with left-sided breast cancer. For this purpose, setup data based on captured 3D surfaces was compared with setup data based on cone beam computed tomography (CBCT). Methods and Materials: Twenty patients treated with DIBH-RT after breast-conserving surgery (BCS) were included. Before the start of treatment, each patient underwent a breath-hold CT scan for planning purposes. During treatment, dose delivery was preceded by setup verification using CBCT of the left breast. 3D surfaces were captured by a surface imaging system concurrently with the CBCT scan. Retrospectively, surface registrations were performed for CBCT to CT and for a captured 3D surface to CT. The resulting setup errors were compared with linear regression analysis. For the differences between setup errors, group mean, systematic error, random error, and 95% limits of agreement were calculated. Furthermore, receiver operating characteristic (ROC) analysis was performed. Results: Good correlation between setup errors was found: R{sup 2}=0.70, 0.90, 0.82 in left-right, craniocaudal, and anterior-posterior directions, respectively. Systematic errors were {<=}0.17 cm in all directions. Random errors were {<=}0.15 cm. The limits of agreement were -0.34-0.48, -0.42-0.39, and -0.52-0.23 cm in left-right, craniocaudal, and anterior-posterior directions, respectively. ROC analysis showed that a threshold between 0.4 and 0.8 cm corresponds to promising true positive rates (0.78-0.95) and false positive rates (0.12-0.28). Conclusions: The results support the application of 3D surface imaging for image guidance in DIBH-RT after BCS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-39: Comparison of PTV Margins Determined by In-Room Stereoscopic Image Guidance and by On-Board Cone Beam Computed Tomography Technique for Brain Radiotherapy Patients

Purpose: Stereoscopic in room kV image guidance is a faster tool in daily monitoring of patient positioning. Our centre, for the first time in the world, has integrated such a solution from BrainLAB (ExacTrac) with Elekta's volumetric cone beam computed tomography (XVI). Using van Herk's formula, we compared the planning target volume (PTV) margins calculated by both these systems for patients treated with brain radiotherapy. Methods: For a total of 24 patients who received partial or whole brain radiotherapy, verification images were acquired for 524 treatment sessions by XVI and for 334 sessions by ExacTrac out of the total 547 sessions. Systematic and random errors were calculated in cranio-caudal, lateral and antero-posterior directions for both techniques. PTV margins were then determined using van Herk formula. Results: In the cranio-caudal direction, systematic error, random error and the calculated PTV margin were found to be 0.13 cm, 0.12 cm and 0.41 cm with XVI and 0.14 cm, 0.13 cm and 0.44 cm with ExacTrac. The corresponding values in lateral direction were 0.13 cm 0.1 cm and 0.4 cm with XVI and 0.13 cm, 0.12 cm and 0.42 cm with ExacTrac imaging. The same parameters for antero-posterior were for 0.1 cm, 0.11 cm and 0.34 cm with XVI and 0.13 cm, 0.16 cm and 0.43 cm with ExacTrac imaging. The margins estimated with the two imaging modalities were comparable within ± 1 mm limit. Conclusion: Verification of setup errors in the major axes by two independent imaging systems showed the results are comparable and within ± 1 mm. This implies that planar imaging based ExacTrac can yield equal accuracy in setup error determination as the time consuming volumetric imaging which is considered as the gold standard. Accordingly PTV margins estimated by this faster imaging technique can be confidently used in clinical setup.

60 APPLIED LIFE SCIENCES↗

A characterization of robust radiation therapy treatment planning methods-from expected value to worst case optimization

Purpose: To characterize a class of optimization formulations used to handle systematic and random errors in radiation therapy, and to study the differences between the methods within this class. Methods: The class of robust methods that can be formulated as minimax stochastic programs is studied. This class generalizes many previously used methods, ranging between optimization of the expected and the worst case objective value. The robust methods are used to plan intensity-modulated proton therapy (IMPT) treatments for a case subject to systematic setup and range errors, random setup errors with and without uncertain probability distribution, and combinations thereof. As reference, plans resulting from a conventional method that uses a margin to account for errors are shown. Results: For all types of errors, target coverage robustness increased with the conservativeness of the method. For systematic errors, best case organ at risk (OAR) doses increased and worst case doses decreased with the conservativeness. Accounting for random errors of fixed probability distribution resulted in heterogeneous dose. The heterogeneities were reduced when uncertainty in the probability distribution was accounted for. Doing so, the OAR doses decreased with the conservativeness. All robust methods studied resulted in more robust target coverage and lower OAR doses than the conventional method. Conclusions: Accounting for uncertainties is essential to ensure plan quality in complex radiation therapy such as IMPT. The utilization of more information than conventional in the optimization can lead to robust target coverage and low OAR doses. Increased target coverage robustness can be achieved by more conservative methods.

60 APPLIED LIFE SCIENCES↗

The Viability of Trajectory Analysis for Diagnosing Dynamical and Chemical Influences on Ozone Concentrations in the UTLS

The viability of trajectory analysis for diagnosing the interplay between chemistry and dynamics is investigated by comparing ozone mixing ratios modelled using air-parcel pathways to values observed along flight tracks during ATTREX (Airborne Tropical TRopopause EXperiment). Trajectories are initiated at the locations of ozone observations and tracked backward in time to their sources at termini of backward trajectories. The modelled values of ozone utilize 3-dimensional analysis fields from WACCM (Whole Atmosphere Community Climate Model) (a chemical-climate model with dynamical fields nudged towards MERRA (Modern-Era Retrospective Analysis and Research Applications) reanalysis) and ERA-interim (product of ECMWF - the European Centre for Medium-Range Weather Forecasts) to determine source mixing ratios with chemical production and loss terms derived from the ozone chemistry used in WACCM. A statistical base of modelled ozone is constructed with 6 trajectory platforms (adiabatic, diabatic, and kinematic forced by ERA-interim and MERRA), two chemical models (WACCM chemistry and no chemistry), and 4 trajectory lengths (5, 10, 20, and 30 days). Linear regression is employed to separate systematic errors from random errors and to characterize the impact of source mixing ratios, path length, vertical motion, and chemistry on modelled ozone errors. Errors in the analysis ozone fields are large, if not dominant, contributors to model error. Random errors are particularly large for point-by-point comparisons, however averaging over 800 km (75 minutes) flight segments substantially reduces random error and exposes systematic errors. Of the two analysis ozone data sets, WACCM, which incorporates detailed chemistry, provides the smaller systematic errors while ERA-interim, which has crude chemistry but assimilates observational data, has the smaller random errors. Of the different trajectory platforms, adiabatic calculations produce the smaller random errors (irrespective of the use of chemistry) but both vertical motion and chemistry are required to optimally reduce systematic errors. These results suggest that meaningful analysis of dynamical and chemical interactions that control ozone mixing ratios are viable on spatial scales larger than a few reanalysis grid spaces, that errors in the analyzed ozone data sets are large but not prohibitively so, and that vertical velocities and heating rates from reanalysis data, while problematic, contain useful information [on the ozone concentrations in the UTLS (Upper Troposphere/Lower Stratosphere)].

ozone↗

Quantifying Errors in TRMM-Based Multi-Sensor QPE Products Over Land in Preparation for GPM

Determining uncertainties in satellite-based multi-sensor quantitative precipitation estimates over land of fundamental importance to both data producers and hydro climatological applications. ,Evaluating TRMM-era products also lays the groundwork and sets the direction for algorithm and applications development for future missions including GPM. QPE uncertainties result mostly from the interplay of systematic errors and random errors. In this work, we will synthesize our recent results quantifying the error characteristics of satellite-based precipitation estimates. Both systematic errors and total uncertainties have been analyzed for six different TRMM-era precipitation products (3B42, 3B42RT, CMORPH, PERSIANN, NRL and GSMap). For systematic errors, we devised an error decomposition scheme to separate errors in precipitation estimates into three independent components, hit biases, missed precipitation and false precipitation. This decomposition scheme reveals hydroclimatologically-relevant error features and provides a better link to the error sources than conventional analysis, because in the latter these error components tend to cancel one another when aggregated or averaged in space or time. For the random errors, we calculated the measurement spread from the ensemble of these six quasi-independent products, and thus produced a global map of measurement uncertainties. The map yields a global view of the error characteristics and their regional and seasonal variations, reveals many undocumented error features over areas with no validation data available, and provides better guidance to global assimilation of satellite-based precipitation data. Insights gained from these results and how they could help with GPM will be highlighted.

Peters-Lidard, Christa D.↗

Reflector sidelobe degradation due to random surface errors

It is well known that the sidelobe structure of a reflector antenna is highly susceptible to random surface errors, and that in most applications it is not adequate to investigate only the average behavior of the antenna. In this study, an attempt is made to determine the probability distribution of the sidelobe level of a reflector antenna subject to some random surface errors. Specifically, the random pattern function is considered and its sidelobe level studied using the level-upcrossing theory. Both the degradation of the maximum sidelobe and the degradation of the sidelobe region with respect to an International Radio Consultative Committee (CCIR) sidelobe envelope are obtained. The theoretical results are found in excellent agreement with those obtained by Monte Carlo simulations. Finally, some useful tolerance charts are presented.

Ling, H.↗

An efficient computational method for characterizing the effects of random surface errors on the average power pattern of reflectors

Based on the works of Ruze (1966) and Vu (1969), a novel mathematical model has been developed to determine efficiently the average power pattern degradations caused by random surface errors. In this model, both nonuniform root mean square (rms) surface errors and nonuniform illumination functions are employed. In addition, the model incorporates the dependence on F/D in the construction of the solution. The mathematical foundation of the model rests on the assumption that in each prescribed annular region of the antenna, the geometrical rms surface value is known. It is shown that closed-form expressions can then be derived, which result in a very efficient computational method for the average power pattern. Detailed parametric studies are performed with these expressions to determine the effects of different random errors and illumination tapers on parameters such as gain loss and sidelobe levels. The results clearly demonstrate that as sidelobe levels decrease, their dependence on the surface rms/wavelength becomes much stronger and, for a specified tolerance level, a considerably smaller rms/wavelength is required to maintain the low sidelobes within the required bounds.

Rahmat-Samii, Y.↗

Sun compass error model

An error model is described for the Apollo 15 sun compass, a contingency navigational device. Field test data are presented along with significant results of the test. The errors reported include a random error resulting from tilt in leveling the sun compass, a random error because of observer sighting inaccuracies, a bias error because of mean tilt in compass leveling, a bias error in the sun compass itself, and a bias error because the device is leveled to the local terrain slope.

Blucker, T. J.↗

Interference versus success probability in quantum algorithms with imperfections

We study the importance of interference for the performance of Shor's factoring algorithm and Grover's search algorithm using a recently proposed interference measure. To this aim we introduce systematic unitary errors, random unitary errors, and decoherence processes in these algorithms. We show that unitary errors which destroy the interference destroy the efficiency of the algorithm, too. However, unitary errors may also create useless additional interference. In such a case the total amount of interference can increase, while the efficiency of the quantum computation decreases. For decoherence due to phase flip errors, interference is destroyed for small error probabilities, and converted into destructive interference for error probabilities approaching 1, leading to success probabilities which can even drop below the classical value. Our results show that in general, interference is necessary in order for a quantum algorithm to outperform classical computation, but large amounts of interference are not sufficient and can even lead to destructive interference with worse than classical success rates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-114: Analysis of MLC Errors On Gamma Pass Rates for Patient-Specific and Conventional Phantoms

Purpose: To evaluate whether a 3D patient-specific phantom is better able to detect known MLC errors in a clinically delivered treatment plan than conventional phantoms. 3D printing may make fabrication of such phantoms feasible. Methods: Two types of MLC errors were introduced into a clinically delivered, non-coplanar IMRT, partial brain treatment plan. First, uniformly distributed random errors of up to 3mm, 2mm, and 1mm were introduced into the MLC positions for each field. Second, systematic MLC-bank position errors of 5mm, 3.5mm, and 2mm due to simulated effects of gantry and MLC sag were introduced. The original plan was recalculated with these errors on the original CT dataset as well as cylindrical and planar IMRT QA phantoms. The original dataset was considered to be a perfect 3D patient-specific phantom. The phantoms were considered to be ideal 3D dosimetry systems with no resolution limitations. Results: Passing rates for Gamma Index (3%/3mm and no dose threshold) were calculated on the 3D phantom, cylindrical phantom, and both on a composite and field-by-field basis for the planar phantom. Pass rates for 5mm systematic and 3mm random error were 86.0%, 89.6%, 98% and 98.3% respectively. For 3.5mm systematic and 2mm random error the pass rates were 94.7%, 96.2%, 99.2% and 99.2% respectively. For 2mm systematic error with 1mm random error the pass rates were 99.9%, 100%, 100% and 100% respectively. Conclusion: A 3D phantom with the patient anatomy is able to discern errors, both severe and subtle, that are not seen using conventional phantoms. Therefore, 3D phantoms may be beneficial for commissioning new treatment machines and modalities, patient-specific QA and end-to-end testing.

60 APPLIED LIFE SCIENCES↗

The effect of image-guided radiation therapy on the margin between the clinical target volume and planning target volume in lung cancer

Introduction: This study aimed to evaluate the effect of image-guided radiation therapy (IGRT) on the margin between the clinical target volume (CTV) and planning target volume (PTV) in lung cancer. Methods: The CTV and PTV margin were determined in three dimensions by four radiation oncologists using a standard method in 10 lung cancer patients, and compared to consensus values. Transfer error was measured using a rigid phantom containing gold markers. Systematic error and random error set up errors were calculated in three dimensions from pre-treatment and post-treatment cone beam CT scans. Finally, the margin between the CTV and PTV was corrected for set up error and calculated. Results: The margins between the CTV and PTV with IGRT (and without IGRT) were 0.88 cm (0.96 cm), 0.99 cm (1.08 cm) and 1.28 cm (1.82 cm) in the anterior and posterior (AP), left and right (LR) and superior and inferior (SI) directions, respectively. Images from two other patients verified the validity of the corrected margin. The target delineation errors of the radiation oncologists are considered to be the largest compared with the set up errors. The application of IGRT reduced the set up errors and the margins between CTV and PTV. Conclusions: The delineation errors of radiation oncologists are the most important factor to consider for the margin between CTV and PTV for lung cancer. IGRT can reduce the margins by reducing the set up errors, especially in the SI direction. Further research is required to assess whether the reduction in the margin is solely based on set up errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two-Step Estimation in a Heteroscedastic Linear Regression Model

We study the problem of estimating a parameter in some heteroscedastic linear regression model in the case where the regressors consist of all order statistics based on the sample of identically distributed not necessarily independent observations with finite second moment. It is assumed that the random errors depend on the parameter and distributions of the corresponding regressors. We propose a two-step procedure for finding explicit asymptotically normal estimators.

97 MATHEMATICS AND COMPUTING↗