Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RAMAN SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Measuring Rocket Engine Temperatures with Hydrogen Raman Spectroscopy

Laser-based combustion diagnostics, such as single-pulse UV Raman spectroscopy and visible Raman spectroscopy, have been successfully applied to optically-accessible rocket-like test articles. If an independent pressure measurement is available, Raman major species concentration measurements can also provide a temperature measurement. However it is desirable to obtain a Raman-derived temperature measurement without the need for simultaneous pressure measurement, especially when chamber pressure may vary spatially. This report describes Raman temperature measurements obtained by exploiting the variation in shape of the H2 Raman spectrum. Hydrogen is advantageous since it is ubiquitous in H2-O2 systems and its Raman spectrum is simpler than for other diatomics. However the influence of high pressure on the H2 Raman spectrum must be investigated. At moderate pressures, well below those of rocket engines, the Raman spectra of O2 and N2 are known to become featureless due to collisional broadening.

Joseph A Wehrmeyer↗

Condition Assessment of Kevlar Composite Materials Using Raman Spectroscopy

This viewgraph presentation includes the following main concepts. Goal: To evaluate Raman spectroscopy as a potential NDE tool for the detection of stress rupture in Kevlar. Objective: Test a series of strand samples that have been aged under various conditions and evaluate differences and trends in the Raman response. Hypothesis: Reduction in strength associated with stress rupture may manifest from changes in the polymer at a molecular level. If so, than these changes may effect the vibrational characteristics of the material, and consequently the Raman spectra produced from the material. Problem Statement: Kevlar composite over-wrapped pressure vessels (COPVs) on the space shuttles are greater than 25 years old. Stress rupture phenomena is not well understood for COPVs. Other COPVs are planned for hydrogen-fueled vehicles using Carbon composite material. Raman spectroscopy is being explored as an non-destructive evaluation (NDE) technique to predict the onset of stress rupture in Kevlar composite materials. Test aged Kevlar strands to discover trends in the Raman response. Strength reduction in Kevlar polymer will manifest itself on the Raman spectra. Conclusions: Raman spectroscopy has shown relative changes in the intensity and FWHM of the ~1613 cm(exp -1) peak. Reduction in relative intensity for creep, fleet leader, and SIM specimens compared to the virgin strands. Increase in FWHM has been observed for the creep and fleet leader specimens compared to the virgin strands. Changes in the Raman spectra may result from redistributing loads within the material due to the disruption of hydrogen bonding between crystallites or defects in the crystallites from aging the Kevlar strands. Peak shifting has not been observed to date. Analysis is ongoing. Stress measurements may provide a tool in the short term.

Washer, Glenn↗

Application of Raman Spectroscopy for Nondestructive Evaluation of Composite Materials

This paper will present an overview of efforts to investigate the application of Raman spectroscopy for the characterization of Kevlar materials. Raman spectroscopy is a laser technique that is sensitive to molecular interactions in materials such as Kevlar, graphite and carbon used in composite materials. The overall goal of this research reported here is to evaluate Raman spectroscopy as a potential nondestructive evaluation (NDE) tool for the detection of stress rupture in Kevlar composite over-wrapped pressure vessels (COPVs). Characterization of the Raman spectra of Kevlar yarn and strands will be presented and compared with analytical models provided in the literature. Results of testing to investigate the effects of creep and high-temperature aging on the Raman spectra will be presented.

Washer, Glenn A.↗

Carbon Raman Spectroscopy of 36 Inter-Planetary Dust Particles

Carbon Raman spectroscopy is a useful tool to determine the degree of order of organic material (OM) in extra-terrestrial matter. As shown for meteoritic OM [e.g., 2], peak parameters of D and G bands are a measure of thermal alteration, causing graphitization (order), and amorphization, e.g. during protoplanetary irradiation, causing disorder. Th e most pristine interplanetary dust particles (IDPs) may come from comets. However, their exact provenance is unknown. IDP collection during Earth?s passage through comet Grigg-Skjellerup?s dust stream ("GSC" collectors) may increase the probability of collecting fresh IDPs from a known, cometary source. We used Raman spectroscopy to compare 21 GSC-IDPs with 15 IDPs collected at different periods, and found that the variation among GSC-IDPs is larger than among non-GSC IDPs, with the most primitive IDPs being mostly GSC-IDPs.

Busemann, H.↗

Raman spectroscopy of zirconium hydride

The characterization of zirconium hydride is important in the nuclear industry because of the hydrogen-induced embrittlement of Zircaloy cladding and its use as a neutron moderator. This paper introduces the use of Raman spectroscopy for the characterization of zirconium hydride. First-principles density functional theory (DFT) calculations were used to predict the Raman spectra of ζ-ZrH 0.5 , γ-ZrH, δ-ZrH 1.5 , δ-ZrH 1.66 , and ε-ZrH 2 with all their predicted symmetries; ζ-ZrH 0.5 (P3m1, R$\overline{3}$m, C2/m, Cm, Cmmm, and Pn$\overline{3}$m); γ-ZrH (P222, Ccce, and P4 2 /mmc); δ-ZrH 1.5 (P$\overline{4}$m2, P4 2 /mcm, Fmmm, Pn$\overline{3}$m, Ibam, P2/c, PI, and P4 2 /nnm); δ-ZrH 1.66 (Fm$\overline{3}$m); and ε-ZrH 2 (Fm$\overline{3}$m, R$\overline{3}$m, and I 4 /mmm). Two samples of Zircaloy-4 containing 133 wt ppm and 360 wt ppm hydrogen were characterized by Raman spectroscopy, showing two signal lines at 215 cm -1 and 1,187 cm -1 , which were assigned to the presence of δ-ZrH 1.66 . These signals had a good spatial correlation with visible hydride precipitates in Raman spectroscopy images. In conclusion, this work provides the basis for the characterization of all possible zirconium hydride compositions and structures using Raman spectroscopy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simultaneous Conoscopic Holography and Raman Spectroscopy

A new instrument was developed for chemical characterization of surfaces that combines the analytical power of Raman spectroscopy with the three-dimensional topographic information provided by conoscopic holography. The figure schematically depicts the proposed hybrid instrument. The output of the conoscopic holographic portion of the instrument is a topographical map of the surface; the output of the Raman portion of the instrument is hyperspectral Raman data, from which the chemical and/or biological composition of the surface would be deduced. By virtue of the basic principles of design and operation of the instrument, the hyperspectral image data would be inherently spatially registered with the topographical data. In conoscopic holography, the object and reference beams of classical holography are replaced by the ordinary and extraordinary components generated by a single beam traveling through a birefringent, uniaxial crystal. In the basic conoscopic configuration, a laser light is projected onto a specimen and the resulting illuminated spot becomes a point source of diffuse light that propagates in every direction. The laser beam is rasterscanned in two dimensions (x and y) perpendicular to the beam axis (z), and at each x,y location, the pattern of interference between the ordinary and extraordinary rays is recorded. The recorded interferogram constitutes the conoscopic hologram. Of particular significance for the proposed instrument is that the conoscopic hologram contains information on the z coordinate (height) of the illuminated surface spot. Hence, a topographical map of the specimen is constructed point-by-point by rastering the laser beam in the x and y directions and correlating the x and y coordinates with the z information obtained from the interferograms. Conoscopic imaging is an established method, and conoscopic laboratory instruments for surface metrology are commercially available. In Raman spectroscopy of a surface, one measures the spectrum of laser light scattered inelastically from a laser-illuminated spot on the surface. The wavelengths of the inelastically scattered light differ from that of the incident laser beam by amounts that correspond to the energies of molecular vibrations. The resulting vibrational spectrum can be used to identify the molecules. Raman spectroscopy is a standard laboratory technique for identifying mineralogical, biological, and other specific chemical compositions.

Schramm, Harry F.↗

Raman spectroscopy of uranium nitride kernels

Uranium nitride is an advanced fuel candidate for a wide variety of advanced nuclear reactors. This work summarizes the first characterization of UN kernels by Raman spectroscopy. First-principles density functional theory calculations were performed to predict the Raman spectra of uranium sesquinitride (U 2 N 3 ), uranium dinitride (UN 2 ), uranium mononitride (UN), uranium monocarbide (UC), as well as U-N-C (UN 1-x C x ) and a U-N-C-O mixture. Further, a core–shell structure was identified by scanning electron microscopy and Raman spectroscopy imaging. A signal at ~500 cm -1 was identified on the periphery of the core-shell structure, possibly corresponding to U 2 N 3 and/or UN 2 . This signal broadens and shifts to 470 cm -1 because of the formation of UNC, UNCO or U 2 N 3+x structures. The culmination of this work demonstrates the feasibility of using Raman spectroscopy to identify variations in composition and phases in UN kernels.

36 MATERIALS SCIENCE↗

Deciphering decomposition pathways of high explosives with cryogenic X-ray Raman spectroscopy

We employed cryogenic X-ray Raman spectroscopy to investigate the early-stage decomposition of the high explosive molecule hexanitrohexaazaisowurtzitane (CL-20). By systematically varying the radiation dose under cryogenic conditions, we induced the decomposition of the molecule using ionizing radiation and observed the evolution of spectral features at the carbon, nitrogen, and oxygen K edges. Through extensive first-principles calculations, we identified key intermediates in the early stages of the decomposition process, resulting from C–C and C–N bond cleavage which leads to the opening of the internal cage structure. A detailed analysis of spectral trends and fingerprints provided evidence supporting N–NO 2 homolytic cleavage as the primary initial decomposition pathway. The combination of advanced core-level spectroscopy methods and state-of-the-art theoretical calculations enabled a comprehensive characterization of the molecular changes induced by controlled radiation dose exposures. In conclusion, our findings establish a benchmark for understanding the decomposition chemistry of high-explosive materials, offering important insights into their stability and reactivity under extreme conditions.

X-ray Raman spectroscopy↗

Application of Raman Spectroscopy to Determine Uranium Content in ADUN Solution

The work presented in this report is part of the ongoing efforts to address the nuclear material control and accounting needs for advanced reactor fuel fabrication facilities. This work was supported by the Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy Office of Nuclear Energy‘s Nuclear Fuel Cycle and Supply Chain program. The activities and engagements under the MPACT program are designed to support a robust US civilian nuclear energy enterprise. In the work described in this report, we supported MPACT objectives by developing measurement techniques that could be used for material accounting and process monitoring and by working with industry partners to identify existing gaps and areas for improvement. Oak Ridge National Laboratory has been working with commercial tristructural isotropic (TRISO) fuel fabricators such as Standard Nuclear to develop technology for rapid and cost-effective uranium content assessment. This work has focused on demonstrating advanced measurement techniques (e.g., Raman spectroscopy) that can be used for rapid, reliable, and cost-effective routine measurements of uranium content in feed solutions and liquid waste streams as well as for monitoring in-line process measurements and product streams. Specifically, this report explores techniques for accurately determining uranium content in acid-deficient uranyl nitrate (ADUN) solutions and detecting low uranium concentrations in ammonia solutions. Developing such measurement techniques will benefit TRISO fuel fabrication facilities, facilities involved in other parts of the fuel cycle that require online monitoring of aqueous solutions, and potentially molten salt fuel reactors. This work supports developing Raman spectroscopy procedures to determine uranium concentrations in ADUN solutions, which are used as feedstock in the sol–gel process for creating TRISO fuel. Some additional benefits of using Raman spectroscopy for uranium quantification in fabrication facilities include enabling online monitoring of the chemical process, which would provide near real-time feedback; eliminating the need for sample transfers, preparation, or dilution; providing nondestructive measurements; and user friendliness. In this fiscal year, FY25, we determined the identity of the unknown Raman band at approximately 853 cm−1 that was discovered in ADUN Raman spectra in FY24, created calibration curves and determined uranium concentrations of two ADUN solutions, and compared the Raman results to results obtained from inductively coupled plasma mass spectrometry and Davies–Gray titration. Furthermore, we have identified focus areas for experimentation in future fiscal years. A key result is that the accuracy of using Raman can provide accuracy comparable to destructive analysist techniques, With a well-developed calibration curve, using standards and a large number of samples (more than five samples), uncertainty on the order of 1%–3% is achievable. Given that the uncertainties achieved by Raman spectroscopy were on the order of the uncertainties achieved using ICP-MS, we conclude that with a well-developed procedure Raman spectroscopy can be used to determine uranium concentrations in ADUN solutions for NMC&A applications. The benefits of such an approach are that the time and effort will be less than that of comparable destructive analysis techniques, with approximately the same level of technical expertise. This will be attractive to operators of fuel fabrication facilities as it will lower costs and improve efficiencies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

5f covalency from x-ray resonant Raman spectroscopy

Here, X-ray resonant Raman spectroscopy (XRRS), a variant of resonant inelastic x-ray scattering, has been used to investigate the two prototype systems, UF 4 and UO 2 . Both are U5f 2 and each is an example of 5f localized, ionic behavior and 5f localized, covalent behavior, respectively. From the M 5 XRRS measurements, the 5f band gap in each can be directly determined and, moreover, a clear and powerful sensitivity to 5f covalency emerges.

36 MATERIALS SCIENCE↗

Reduction of Raman Spectroscopy Data for H2-CO2-Air Tubular Flame Measurements

An approach of reducing spontaneous Raman spectroscopy data, based on the matrix inversion method which logically removes undesired sources of the Raman scattering signals including cross-talk due to the signals from other species, is discussed. The approach contains extensive calibration of temperature-dependent system response. The Raman spectra of several cold and hot calibration flames and their resulting calibration matrix are elaborated. The structure of H2-CO2-air tubular flames, in terms of major species (CO2, O2, N2, H2O, and H2) concentrations and temperature, was successfully measured with the optical technique. The Raman spectra data used in this study are taken from a uniquely designed experimental apparatus – a tubular burner and Raman spectroscopy system at Vanderbilt University. The characteristic uncertainties for chemical species are approximately ±2% by mole fraction for hot products and ±0.5% for room temperature reactants. The approach described here for hydrogen/air tubular flames may be adapted to hydrocarbon/air tubular flames when other necessary major species, for example, CH4 and CO for methane/air tubular flame, are considered in the whole process.

Raman Spectroscopy↗

Near-Infrared (NIR) Raman Spectroscopy of Precambrian Carbonate Stromatolites with Post-Depositional Organic Inclusions

Raman spectroscopy has promising potential for future Mars missions as a non-contact detection technique for characterizing organic material and mineralogy. Such a capability will be useful for selecting samples for detailed analysis on a rover and for selecting samples for return to Earth. Stromatolites are important evidence for the earliest life on Earth and are promising targets for Mars investigations. Although constructed by microorganisms, stromatolites are organo-sedimentary structures that can be large enough to be discovered and investigated by a Mars rover. In this paper, we report the Raman spectroscopic investigations of the carbonate mineralogy and organic layering in a Precambrian (;1.5 Gyr old) stromatolite from the Crystal Spring Formation of Southern California. Ultraviolet (UV: 266 nm), visible (514 nm, 633 nm), and near-infrared (NIR: 785 nm, 1064 nm) Raman spectra are presented. We conclude that 1064 nm excitation is the optimal excitation wavelength for avoiding intrinsic fluorescence and detecting organic carbon within the carbonate matrix. Our results confirm that NIR Raman spectroscopy has important applications for future Mars missions.

Tanaka, Zuki↗

Development of a continuous synthesis process for carbamazepine using validated in-line Raman spectroscopy and kinetic modelling for disturbance simulation

Mitigation of failure modes in the continuous synthesis (CS) of a drug substance (DS) has the potential to widen the adoption of continuous manufacturing (CM) technologies by the pharmaceutical industry. Here, this work demonstrates the development of a robust continuous process for the synthesis of carbamazepine (CBZ), an essential medicine as per the World Health Organization (WHO), facilitated by kinetic modelling and monitored by in-line Raman spectroscopy. Accurate kinetic modelling and the use of validated process analytical technology (PAT) models for quantitative measurement were found to play an important role in developing CS of drug substances. Kinetic data for the formation of CBZ from iminostilbene (ISB) were collected by batch reaction sampling and high-performance liquid chromatography (HPLC) analysis. A non-linear solver and iterative method was applied to determine two sets of Arrhenius parameters simultaneously for the reaction system by minimizing the standard error of the model fit. The start-up and dynamic equilibrium stages for the CS of CBZ using a continuous stirred tank reactor (CSTR) were modelled based on the batch kinetic data and employed to optimize conversion and simulate process disturbances. An in-line Raman spectroscopy method was successfully developed, validated, and integrated to determine the concentrations of CBZ and ISB within the operating range for the CS. The CS kinetic model was evaluated experimentally from startup to dynamic equilibrium over 10 residence times with monitoring by HPLC and in-line Raman spectroscopy. The developed kinetic model in tandem with in-line Raman spectroscopy successfully predicted disturbances due to changes in process variables and can serve as a useful tool in the future design of advanced process control strategies for the continuous synthesis of CBZ.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro Raman Spectroscopy for Characterizing Molecular Contamination on Space Flight Hardware

In the field of contamination control,many unknowns exist. Often, contamination control engineers have to utilize multiple spectroscopic, macroscopic, and microscopic tools to identify contamination sources when there is a potential contamination exposure to space flight hardware. Understanding the chemical composition of the molecular contamination provides an opportunity for contamination control engineers to determine if this contamination is problematic or benign. In this study, an existing witness plate program for monitoring space flight hardware during the assembly, integration, and testing phases is coupled with micro Raman spectroscopy analysis. The main goal of this study is to determine the limitations, reproducibility, and throughput of micro Raman spectroscopy for characterizing molecular contamination. Micro Raman Spectroscopy will be an additional tool used by contamination control engineers to monitor the cleanliness of space flight hardware.

Microscope↗

Raman spectroscopy of premixed CH4/N20 flames

Spontaneous Raman spectroscopy was used to make temperature and number density profile measurements in CH4/N20 flames. Preliminary measurements above the primary reaction zone agree with thermochemical equilibrium calculations. A temperature profile was measured through the primary reaction zone of this flame. This profile clearly demonstrates the capability of this diagnostic tool to make accurate temperature measurements with good spatial resolution.

Beyer, R. A.↗

Mapping the Residual Stress Distribution in Polycrystalline Quartz Tiger's Eye Using Raman Spectroscopy

Stress distribution maps in polycrystalline materials are needed to reveal stress pathways caused by short‐and long‐range interactions of crystallites. Stress induced changes to wavenumbers in Raman spectroscopy is a well‐known phenomenon that occurs when a crystalline material undergoes elastic strain. Using spatially resolved Raman spectroscopy, we have developed a technique to experimentally measure grain‐scale residual stresses across a sample of polycrystal quartz Tiger's Eye. The results of this technique are validated using multiple criteria, including evaluation of the residual stress map itself and the accuracy of the measurements taken. The residual map of Tiger's Eye shows striking similarity to observed characteristics of other polycrystalline residual stress distributions, revealing heterogenous areas of high and low magnitude stresses. The stress magnitudes are consistent with residual stress magnitudes previously measured from polycrystalline quartz. Characterization of Tiger's Eye quartz also revealed the geometric nature of the iron oxide inclusions, not previously observed in Tiger's Eye quartz. With this technique, we present a residual stress map of Tiger's Eye quartz that shows with accuracy a heterogeneous stress state with inter‐ and intra‐granular detail.

36 MATERIALS SCIENCE↗

Investigating the electronic structure of high explosives with X-ray Raman spectroscopy

Abstract We investigate the sensitivity and potential of a synergistic experiment-theory X-ray Raman spectroscopy (XRS) methodology on revealing and following the static and dynamic electronic structure of high explosive molecular materials. We show that advanced ab-initio theoretical calculations accounting for the core-hole effect based on the Bethe-Salpeter Equation (BSE) approximation are critical for accurately predicting the shape and the energy position of the spectral features of C and N core-level spectra. Moreover, the incident X-ray dose typical XRS experiments require can induce, in certain unstable structures, a prominent radiation damage at room temperature. Upon developing a compatible cryostat module for enabling cryogenic temperatures ( $$\approx$$ ≈ 10 K) we suppress the radiation damage and enable the acquisition of reliable experimental spectra in excellent agreement with the theory. Overall, we demonstrate the high sensitivity of the recently available state-of-the-art X-ray Raman spectroscopy capabilities in characterizing the electronic structure of high explosives. At the same time, the high accuracy of the theoretical approach may enable reliable identification of intermediate structures upon rapid chemical decomposition during detonation. Considering the increasing availability of X-ray free-electron lasers, such a combined experiment-theory approach paves the way for time-resolved dynamic studies of high explosives under detonation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗