Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Seeding Coherent Radiation Sources with Sawtooth Modulation

Seed radiation sources have the ability to increase longitudinal coherence, decrease saturation lengths, and improve performance of tapering, polarization control and other FEL features. Typically, seeding schemes start with a simple sinusoidal modulation, which is manipulated to provide bunching at a high harmonic of the original wavelength. In this paper, we consider seeding from sawtooth modulations. The sawtooth creates a clean phase space structure, providing a maximal bunching factor without the need for an FEL interaction. While a pure sawtooth modulation is a theoretical construct, it is possible to approach the waveform by combining two or more of the composite wavelengths. We give examples of sawtooth seeding for HGHG, EEHG and other schemes, and note that the sawtooth modulation may aid in suppression of the microbunching instability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation Source Replacement Workshop

This report summarizes a Radiation Source Replacement Workshop in Houston Texas on October 27-28, 2010, which provided a forum for industry and researchers to exchange information and to discuss the issues relating to replacement of AmBe, and potentially other isotope sources used in well logging.

07 ISOTOPE AND RADIATION SOURCES↗

457-nm radiation source based on a diode laser for precision spectroscopy of magnesium atoms

We report on the development of a highly stable source of 457-nm radiation based on a diode laser and a tapered amplifier operating in a double-pass scheme. The diode laser frequency was stabilised by a high-Q reference Fabry – Perot interferometer and doubled in a PPSLT nonlinear crystal placed in an enhancement cavity. At a maximum output power of 200 mW at a wavelength of 457 nm, the laser linewidth was less than 5 kHz. The radiation source operation was demonstrated in experiments on precision spectroscopy of cold magnesium atoms in a magneto-optical trap. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Sources and Criticality Safety - 14392

This paper consists essentially of a two part discussion concerning the effects that extraneous radiation sources have on fissionable material systems with respect to criticality and criticality safety. The first part (sections 2 and 3) concentrates on a qualitative discussion about extraneous radiation sources and definitions associated with the criticality of neutron chain reacting systems. The second part (section 4), while it does not constitute a rigorous proof, focuses more on the mathematics governing neutron distribution in general and fissionable material systems. The goal of both parts is the same, i.e. to dispel the notion that a subcritical system can be driven critical by simply supplying a source of neutrons to make up losses. Either part, or both, can be relied on as references in situations in which a criticality safety concern is inappropriately raised for situations where extraneous radiation sources are utilized to perform measurements with subcritical configurations of special nuclear materials. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Radiation source for helium magnetometers

A radiation source (12) for optical magnetometers (10) which use helium isotopes as the resonance element (30) includes an electronically pumped semiconductor laser (12) which produces a single narrow line of radiation which is frequency stabilized to the center frequency of the helium resonance line to be optically pumped. The frequency stabilization is accomplished using electronic feedback (34, 40, 42, 44) to control a current sources (20) thus eliminating the need for mechanical frequency tuning.

Slocum, Robert E.↗

Spontaneous Raman scattering as a high resolution XUV radiation source

A type of high resolution XUV radiation source is described which is based upon spontaneous anti-Stokes scattering of tunable incident laser radiation from atoms excited to metastable levels. The theory of the source is summarized and two sets of experiments using He (1s2s)(1)S atoms, produced in a cw hollow cathode and in a pulsed high power microwave discharge, are discussed. The radiation source is used to examine transitions originating from the 3p(6) shell of potassium. The observed features include four previously unreported absorption lines and several sharp interferences of closely spaced autoionizing lines. A source linewidth of about 1.9 cm(-1) at 185,000 cm(-1) is demonstrated.

Rothenberg, J. E.↗

Spontaneous Raman scattering as a high-resolution XUV radiation source

A type of high resolution XUV radiation source is described which is based upon spontaneous anti-Stokes scattering of tunable incident laser radiation from atoms excited to metastable levels. The theory of the source is summarized and two sets of experiments using He (1s2s)(1)S atoms, produced in a CW hollow cathode and in a pulsed high power microwave discharge, are discussed. The radiation source is used to examine transitions originating from the 3p(6) shell of potassium. The observed features include four previously unreported absorption lines and several sharp interferences of closely spaced autoionizing lines. A source linewidth of about 1.9 cm(-1) at 185,000 cm(-1) is demonstrated. Previously announced in STAR as N83-18422

Rothenberg, J. E.↗

Free electron terahertz wave radiation source with two-section periodical waveguide structures

We analyze a free electron terahertz wave radiation source with two-section periodical waveguide structure (PWS), where the first section (section-I) is used to pre-modulate the electron beam and the second section (section-II) is for terahertz wave generation. By means of theoretical analysis and numerical simulations, we demonstrate that the starting current density of the beam-wave interaction in section-II can be significantly reduced provided that the operation frequency is the harmonic of electron beam's pre-modulation frequency. This kind of source can generate relatively high power terahertz wave radiation but only need moderate beam current density. And it may have great potential application in developing the compact and high power terahertz wave radiation source.

07 ISOTOPE AND RADIATION SOURCES↗

Network Algorithms for Detection of Radiation Sources

In support of national defense, Domestic Nuclear Detection Office’s (DNDO) Intelligent Radiation Sensor Systems (IRSS) program supported the development of networks of radiation counters for detecting, localizing and identifying low-level, hazardous radiation sources. Industry teams developed the first generation of such networks with tens of counters, and demonstrated several of their capabilities in indoor and outdoor characterization tests. Subsequently, these test measurements have been used in algorithm replays using various sub-networks of counters. Test measurements combined with algorithm outputs are used to extract Key Measurements and Benchmark (KMB) datasets. We present two selective analyses of these datasets: (a) a notional border monitoring scenario that highlights the benefits of a network of counters compared to individual detectors, and (b) new insights into the Sequential Probability Ratio Test (SPRT) detection method, which lead to its adaptations for improved detection. Using KMB datasets from an outdoor test, we construct a notional border monitoring scenario, wherein twelve 2”*2” NaI detectors are deployed on the periphery of 21*21meter square region. A Cs-137 (175 uCi) source is moved across this region, starting several meters from outside and finally moving away. The measurements from individual counters and the network were processed using replays of a particle filter algorithm developed under IRSS program. The algorithm outputs from KMB datasets clearly illustrate the benefits of combining measurements from all networked counters: the source was detected before it entered the region, during its trajectory inside, and until it moved several meters away. When individual counters are used for detection, the source was detected for much shorter durations, and sometimes was missed in the interior region. The application of SPRT for detecting radiation sources requires choosing the detection threshold, which in turn requires a source strength estimate, typically specified as a multiplier of the background radiation level. A judicious selection of this source multiplier is essential to achieve optimal detection probability at a specified false alarm rate. Typically, this threshold is chosen from the Receiver Operating Characteristic (ROC) by varying the source multiplier estimate. ROC is expected to have a monotonically increasing profile between the detection probability and false alarm rate. We derived ROCs for multiple indoor tests using KMB datasets, which revealed an unexpected loop shape: as the multiplier increases, detection probability and false alarm rate both increase until a limit, and then both contract. Consequently, two detection probabilities correspond to the same false alarm rate, and the higher is achieved at a lower multiplier, which is the desired operating point. Using the Chebyshev’s inequality we analytically confirm this shape. Then, we present two improved network-SPRT methods by (a) using the threshold off-set as a weighting factor for the binary decisions from individual detectors in a weighted majority voting fusion rule, and (b) applying a composite SPRT derived using measurements from all counters.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Method and system for imaging a radiation source

A method for imaging a radiation source, and a device that utilizes these methods that in one embodiment include the steps of: calculating at least one Compton cone of a first parameter of a radiation emission from information received from a sensor occurrence; and tracing this Compton cone on to a unit sphere having preselected characteristics using an estimated angular uncertainty to limit at least a portion of said tracing. In another embodiment of the invention at least two Compton cones are calculated and then intersected upon a predefined surface such as a sphere. These intersection points can then be iterated over a preselected series of prior events.

Myjak, Mitchell J↗

High-viscosity injector-based pink-beam serial crystallography of microcrystals at a synchrotron radiation source

Since the first successful serial crystallography (SX) experiment at a synchrotron radiation source, the popularity of this approach has continued to grow showing that third-generation synchrotrons can be viable alternatives to scarce X-ray free-electron laser sources. Synchrotron radiation flux may be increased ∼100 times by a moderate increase in the bandwidth (`pink beam' conditions) at some cost to data analysis complexity. Here, we report the first high-viscosity injector-based pink-beam SX experiments. The structures of proteinase K (PK) and A 2A adenosine receptor (A 2A AR) were determined to resolutions of 1.8 and 4.2 Å using 4 and 24 consecutive 100 ps X-ray pulse exposures, respectively. Strong PK data were processed using existing Laue approaches, while weaker A 2A AR data required an alternative data-processing strategy. This demonstration of the feasibility presents new opportunities for time-resolved experiments with microcrystals to study structural changes in real time at pink-beam synchrotron beamlines worldwide.

36 MATERIALS SCIENCE↗

Anti-Stokes scattering as an XUV radiation source

Harris (1977) has shown that laser induced scattering from atoms stored in a metastable level may be used to produce an XUV radiation source with several unique properties, including narrow linewidth, tunability, linear polarization, picosecond pulsewidth, and relatively high peak spectral brightness. The present investigation provides a summary concerning the progress made on the use of this radiation source as a unique instrument for XUV spectroscopy, and as a possible flashlamp for a 200 A laser. Zych et al. (1978) demonstrated that the maximum spectral brightness of the source is that of a blackbody with a temperature of the metastable storage level. The peak count rate and peak spectral brightness of the anti-Stokes emission at 569 A are 17 times and 139 times greater than those of the 584 A resonance line. The anti-Stokes process was employed as an external source of radiation for high resolution spectroscopy of the 3p6 shell of potassium. Attention is also given to emission spectroscopy of lithium, metastable levels which are appropriate for storage, and a hollow cathode discharge.

Harris, S. E.↗

Blackbody radiation sources for the IR spectral range

Metrological radiometric facilities for optoelectronic instruments calibration utilize in terms of standards as radiation detectors in a form of cryogenic radiometers (CR), so as radiation sources. However in practice, there are no CR working within IR spectral range. An alternative way of radiometric calibration in middle and far IR ranges is to develop a parametric series of standard radiation sources - blackbody (BB) models. The paper describes some of BBs developed at VNIIOFI for the last time [1] from cryogenic (80 K to 200 K), to low (about 200 K to 400 K) and medium (400 K to 700 K) temperature regions for calibration of the IR instruments under cryogenic-vacuum conditions. These BBs are presented by models of both types: variable-temperature and based on fixed points of Ga or In. BBs are characterized with high temperature uniformity and stability. Copper and aluminum alloys are used as the radiation cavity materials. The required value of emissivity ε{sub λ} is achieved by using different black coatings. Low-temperature and cryogenic BBs are based on the principles of indirect multi-zone electric heating (with heat isolation from LN2 cooling loop, or by using an external liquid thermostat with circulating heat-transfer agent. The principles of operation, design and test results of BBs are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SCALE 6.3.1 Radiation Source Terms and Shielding Analysis for a Postulated Sodium-Cooled Fast Reactor Accident Scenario

In support of the US Nuclear Regulatory Commission non–light-water reactor fuel cycle demonstration project, SCALE 6.3.1 capabilities for radiation source term and shielding calculations are demonstrated for scenarios in the sodium-cooled fast reactor (SFR) fuel cycle. A postulated accident scenario, which consists of a seismic event causing the refueling machine to fall and release a spent fuel assembly inside the containment building (CB), is analyzed in this paper. Radiation source terms were generated for a U/TRU-10Zr metal fuel assembly with a 16.5% initial transuranic waste content and a discharge burnup of approximately 95 GWd/tHM; source terms were also generated for a high-assay low-enriched uranium metal fuel assembly (U-10Zr) with a 16.5% initial enrichment and a discharge burnup of 149.74 GWd/tHM. These radiation source terms were then used to determine the dose rate inside the CB and near the outer surface of the CB for a range of spent fuel assembly cooling times. The dose rate produced by the analyzed SFR assemblies is similar to that produced by a typical pressurized water reactor assembly with a discharge burnup of 50 GWd/MTU. Ultimately, the validation of the source terms predicted for SFRs with SCALE will need to be demonstrated via the use of assay measurements.

Radulescu, Georgeta↗

Devices Materials and Processes for Nanoelectronics: Characterization with Advanced X-Ray Techniques Using Lab-Based and Synchrotron Radiation Sources

Future nanoelectronics manufacturing at extraordinary length scales, new device structures, and advanced materials will provide challenges to process development and engineering but also to process control and physical failure analysis. Advanced X-ray techniques, using lab systems and synchrotron radiation sources, will play a key role for the characterization of thin films, nanostructures, surfaces, and interfaces. The development of advanced X-ray techniques and tools will reduce risk and time for the introduction of new technologies. Eventually, time-to-market for new products will be reduced by the timely implementation of the best techniques for process development and process control. The development and use of advanced methods at synchrotron radiation sources will be increasingly important, particularly for research and development in the field of advanced processes and new materials but also for the development of new X-ray components and procedures. The application of advanced X-ray techniques, in-line, in out-of-fab analytical labs and at synchrotron radiation sources, for research, development, and manufacturing in the nanoelectronics industry is reviewed. The focus of this paper is on the study of nanoscale device and on-chip interconnect materials, and materials for 3D IC integration as well.

77 NANOSCIENCE AND NANOTECHNOLOGY↗