Apparatus for measuring high-flux heat transfer in radiatively heated compact exchangers

An apparatus is described which can deliver uniform heat flux densities of up to 80 W/sq cm over an area 7.8 cm x 15.2 cm for use in measuring the heat transfer and pressure drop in thin (6 mm or less), compact heat exchangers. Helium gas at flow rates of 0 to 40 kg/h and pressures to 6.9 MPa (1000 psi) is the working fluid. The instrumentation used in the apparatus and the methods for analyzing the data is described. The apparatus will be used initially to test the performance of prototype cooling jackets for the engine struts of the National Aerospace Plane (NASP).

Olson, Douglas A.↗

Instrumentation for Measuring Entry Radiative Heating - Past, Present, and Future

Radiative heating can be a significant contributor to the total heat load during atmospheric entry, especially for large vehicles with high entry velocties. For example, the stagnation region heat load derived from thermocouples embedded in the thermal protection system (TPS)of the Mars Science Laboratory (MSL) heatshield did not match the unmargined pre-flight predictions. This was at least partially attributed to the fact that radiative heating was not accounted for in the unmargined pre-flight predictions [2].Since MSL, significant work has been done to update radiative heating models and test how the models perform compared to ground-based test facilities such as shock tubes. The models and ground-based tests have shown that radiative heating can be significant for entry into the atmospheres of Venus, Earth, Mars, and Titan, among other planetary bodies. However, there are still discrepancies between the models and the test data, which is where the desire for flight data comes in to play. Missions that have had or are currently planned to have instrumentation to measure radiative heating during atmospheric entry are listed in Table 1.

R A Miller↗

Features of Afterbody Radiative Heating for Earth Entry

Radiative heating is identified as a major contributor to afterbody heating for Earth entry capsules at velocities above 10 km/s. Because of rate-limited electron-ion recombination processes, a large fraction of the electronically-excited N and O atoms produced in the high temperature/pressure forebody remain as they expand into the afterbody region, which results in significant afterbody radiation. Large radiative heating sensitivities to electron-impact ionization rates and escape factors are identified. Ablation products from a forebody ablator are shown to increase the afterbody radiation by as much as 40%. The tangent-slab radiation transport approach is shown to over-predict the radiative flux by as much as 40% in the afterbody, therefore making the more computationally expensive ray-tracing approach necessary for accurate radiative flux predictions. For the Stardust entry, the afterbody radiation is predicted to be nearly twice as large as the convective heating during the peak heating phase of the trajectory. Comparisons between simulations and the Stardust Echelle observation measurements, which are shown to be dominated by afterbody emission, indicate agreement within 20% for various N and O lines. Similarly, calorimeter measurements from the Fire II experiment are identified as a source of validation data for afterbody radiation. For the afterbody calorimeter measurement closest to the forebody, which experiences the largest afterbody radiative heating component, the convective heating alone is shown to under-predict the measurement, even for the fullycatalytic assumption. Agreement with the measurements is improved with the addition of afterbody radiation. These comparisons with Stardust and Fire II measurements provide validation that the significant afterbody radiation values proposed in this work are legitimate.

Johnston, Christopher O.↗

Parallel-plate submicron gap formed by micromachined low-density pillars for near-field radiative heat transfer

Near-field radiative heat transfer has been a subject of great interest due to the applicability to thermal management and energy conversion. In this letter, a submicron gap between a pair of diced fused quartz substrates is formed by using micromachined low-density pillars to obtain both the parallelism and small parasitic heat conduction. The gap uniformity is validated by the optical interferometry at four corners of the substrates. The heat flux across the gap is measured in a steady-state and is no greater than twice of theoretically predicted radiative heat flux, which indicates that the parasitic heat conduction is suppressed to the level of the radiative heat transfer or less. The heat conduction through the pillars is modeled, and it is found to be limited by the thermal contact resistance between the pillar top and the opposing substrate surface. The methodology to form and evaluate the gap promotes the near-field radiative heat transfer to various applications such as thermal rectification, thermal modulation, and thermophotovoltaics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cascaded-Blackbody Heat Radiators

New class of heat radiators made of metal or other conductive fin stock, fins of which are textured or covered with smaller fins. Measured from outside, effective emissivity of projected radiator surface greater than, and somewhat independent of, emissivity of flat surface made of same material. Special coatings to enhance emissivity not required, and emissivity not degraded significantly in long term by environmental effects. Intended orginally to radiate excess heat away from spacecraft, new radiators also used on Earth to dissipate heat in vacuum systems.

Keddy, Michael D.↗

Design and calibration of a novel transient radiative heat flux meter for a spacecraft thermal test

Radiative heat flux measurement is significantly important for a spacecraft thermal test. To satisfy the requirements of both high accuracy and fast response, a novel transient radiative heat flux meter was developed. Its thermal receiver consists of a central thermal receiver and two thermal guarded annular plates, which ensure the temperature distribution of the central thermal receiver to be uniform enough for reasonably applying lumped heat capacity method in a transient radiative heat flux measurement. This novel transient radiative heat flux meter design can also take accurate measurements regardless of spacecraft surface temperature and incident radiation spectrum. The measurement principle was elaborated and the coefficients were calibrated. Experimental results from testing a blackbody furnace and an Xenon lamp show that this novel transient radiative heat flux meter can be used to measure transient radiative heat flux up to 1400 W/m{sup 2} with high accuracy and the response time of less than 10 s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introduction to Radiative Heating

Introduction to radiative heat transfer physics and modeling as applied to NASA's planetary entry vehicles. *This document is not available for preview. Please download below to view the document

Brett A. Cruden↗