Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Determination of {chi}{sub c} and {chi}{sub b} polarizations from dilepton angular distributions in radiative decays

The angular distributions of the decay products in the successive decays {chi}{sub c}({chi}{sub b}){yields}J/{psi}({Upsilon}){gamma} and J/{psi}({Upsilon}){yields}l{sup +}l{sup -} are calculated as a function of the angular momentum composition of the decaying {chi} meson and of the multipole structure of the photon radiation, using a formalism independent of production mechanisms and polarization frames. The polarizations of the {chi} states produced in high-energy collisions can be derived from the dilepton decay distributions of the daughter J/{psi} or {Upsilon} mesons, with a reduced dependence on the details of the photon reconstruction or simulation. Moreover, this method eliminates the dependence of the polarization measurement on the actual details of the multipole structure of the radiative transition. Problematic points in previous calculations of the {chi}{sub c} decay angular distributions are identified and clarified.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of Best-Practices and Computationally Inexpensive Radiative Exchange Models for Discrete Element Method Modeling of Aluminosilicate Particles in Concentrating Solar Power Environments

Chemically inert, aluminosilicate based particles have been investigated as both a thermal transport and sensible energy storage medium for concentrating solar power facilities. These particles will experience a wide range of operating temperatures (300-1000 K) and handling conditions (dense to dilute falling particle curtains, dense granular flows, or dense structures), requiring specially-designed and optimized infrastructures. The relative influence of collisional and frictional interactions between particles varies based on temperature-dependent particulate properties and greatly impacts the bulk, granular flow behavior. These underlying physics are captured using discrete element method modeling tools. However, this modeling method is computationally expensive as each particle position and interaction is tracked during the simulation. These modeling methods are further complicated by introducing temperature-dependent particle properties, high-temperature radiative exchange, and directional irradiation sources experienced by granular flows in concentrating solar power environments. In this study, coupled experimental and numerical slump testing of aluminosilicate particles was performed and computationally efficient radiative exchange models were evaluated to establish best-practices for discrete element method models for concentrating solar power environments. The three particle types investigated included Carbobead HSP 30 /60, Carbobead CP 30/60, and Granusil 4030. Existing modeling limitations and computationally-efficient multi-modal heat transfer models were evaluated using Aspherix®, a commercial discrete element method software. High-temperature (< 1073 K) slump testing of aluminosilicate particles was performed to investigate the deviation between experimentally-observed and numerically-predicted angles of repose introduced by computation-time reduction practices including the relaxation of the particle elastic modulus and coarse-graining. Coarse-graining is used to use a single modeled particle that is representative of a collection of smaller particles, decreasing the computational cost at the expense of geometric accuracy. Additionally, relaxation of the elastic modulus is used to reduce computational time at the expense of an increased, modeled particle overlap. Prior studies have determined that aluminosilicate particles retain a high elastic modulus at high temperatures (< 1073 K), requiring small simulation timesteps to ensure resolved contact forces resemble appropriate solid mechanics. A parametric study was performed to evaluate the influence of computation time improvements on the deviation between experimental and modeled angle of repose across high temperatures < 1073 K. Additionally, numerical case studies were performed on candidate particle systems at varying porosities and temperatures. These studies were performed to investigate the influence of computationally-efficient radiative-exchange modeling methods coupled to Aspherix® on modeled accuracy and computation time. The recently-developed distance-based approximation was evaluated in estimating radiative exchange between particles and participating surfaces located in close proximity. The distance based approximation was developed to use tabulated estimates of the radiative distribution factor between individual particles and surfaces in close proximity (< 40 particle radii). These methods were expanded to the aluminosilicate particles of interest, including the influence of particle size distributions. To capture radiative exchange between particles and surfaces not in close proximity (> 40 particle radii) and to capture the absorption of directional irradiation from concentrating solar resources, a volumetrically-averaged radiative distribution factor was calculated between the modeled granular flow and surfaces using Monte Carlo ray-tracing for participating media. Volume-averaged absorption and scattering coefficients were predicted using a volumetric discretization of the modeled domain with monodisperse approximations based on geometric optics and experimentally-determined scattering phase functions for aluminosilicate particles.

14 SOLAR ENERGY↗

Spatial distribution of radiation damage to crystalline proteins at 25–300 K

Dose-dependent atomic B factors are used to determine the average spatial distribution of radiation damage to crystalline thaumatin and urease. The spatial distribution of radiation damage (assayed by increases in atomic B factors) to thaumatin and urease crystals at temperatures ranging from 25 to 300 K is reported. The nature of the damage changes dramatically at approximately 180 K. Above this temperature the role of solvent diffusion is apparent in thaumatin crystals, as solvent-exposed turns and loops are especially sensitive. In urease, a flap covering the active site is the most sensitive part of the molecule and nearby loops show enhanced sensitivity. Below 180 K sensitivity is correlated with poor local packing, especially in thaumatin. At all temperatures, the component of the damage that is spatially uniform within the unit cell accounts for more than half of the total increase in the atomic B factors and correlates with changes in mosaicity. This component may arise from lattice-level, rather than local, disorder. The effects of primary structure on radiation sensitivity are small compared with those of tertiary structure, local packing, solvent accessibility and crystal contacts.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The spectral and spatial distribution of radiation from Eta Carinae. II High-resolution infrared maps of the Homunculus

The spectral and spatial distribution of radiation from Eta Carinae II and high-resolution infrared maps of the Homunculus are presented. It is found that at the resolution of 1.1 arcsec the source is resolved into two intensity peaks at four wavelengths from 3.6 to 11.2 microns. The separation of the two peaks with wavelength is discussed, concluding that they are produced by an asymmetrical distribution of dust formed by extensive mass loss from the central source. The extension of the wings of the source at various wavelengths provide confirmatory evidence for an enrichment of a grain species such as corundum, relative to silicate material in the outer regions of the source.

Hyland, A. R.↗

Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE{sup Registered-Sign} radiochromic plastic

Purpose: Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE{sup Registered-Sign} with optical-CT readout. Methods: Ge-doped SiO{sub 2} fibers with 6 {mu}m active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 {mu}m active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE{sup Registered-Sign }, 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. Results: All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE{sup Registered-Sign }, and the latter two suffered from unacceptable noise and artifact. For the experimental conditions used in this study, the useful range from an isolated HDR source was 5-40 mm for fibers, 3-50 mm for EBT3, and 4-21 mm for PRESAGE{sup Registered-Sign }. Fibers demonstrated some over-response at very low dose levels, suffered from volume averaging effects in the dose distribution measurement, and exhibited up to 9% repeatability variation over three repeated measurements. EBT3 demonstrated excellent agreement with Monte Carlo and TPS dose distributions, with up to 3% repeatability over three measurements. PRESAGE{sup Registered-Sign} gave promising results, being the only true 3D dosimeter, but artifacts and noise were apparent. Conclusions: The comparative response of three emerging dosimetry systems for clinical brachytherapy dose distribution measurement has been investigated. Ge-doped optical fibers have excellent spatial resolution for single-direction measurement but are currently too large for complex dose distribution assessment. The use of PRESAGE{sup Registered-Sign} with optical-CT readout gave promising results in the measurement of true 3D dose distributions but further development work is required to reduce noise and improve dynamic range for brachytherapy dose distribution measurements. EBT3 Gafchromic film with multichannel analysis demonstrated accurate and reproducible measurement of dose distributions in HDR brachytherapy. Calibrated dose measurements were possible with agreement within 1.5% of TPS dose calculations. The suitability of EBT3 as a dosimeter for 2D quality control or commissioning work has been demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Consequences of Anatomic Changes and Respiratory Motion on Radiation Dose Distributions in Conformal Radiotherapy for Locally Advanced Non-Small-Cell Lung Cancer

Purpose: To determine the effect of interfractional changes in anatomy on the target and normal tissue dose distributions during course of radiotherapy in non-small-cell lung cancer patients. Methods and Materials: Weekly respiration-correlated four-dimensional computed tomography scans were acquired for 10 patients. Original beam arrangements from conventional and inverse treatment plans were transferred into each of the weekly four-dimensional computed tomography data sets, and the dose distributions were recalculated. Dosimetric changes to the target volumes and relevant normal structures relative to the baseline treatment plans were analyzed by dose-volume histograms. Results: The overall difference in the mean {+-} standard deviation of the doses to 95% of the planning target volume and internal target volume between the initial and weekly treatment plans was -11.9% {+-} 12.1% and -2.5% {+-} 3.9%, respectively. The mean {+-} standard deviation change in the internal target volume receiving 95% of the prescribed dose was -2.3% {+-} 4.1%. The overall differences in the mean {+-} standard deviation between the initial and weekly treatment plans was 3.1% {+-} 6.8% for the total lung volume exceeding 20 Gy, 2.2% {+-} 4.8% for mean total lung dose, and 34.3% {+-} 43.0% for the spinal cord maximal dose. Conclusion: Serial four-dimensional computed tomography scans provided useful anatomic information and dosimetric changes during radiotherapy. Although the observed dosimetric variations were small, on average, the interfractional changes in tumor volume, mobility, and patient setup was sometimes associated with dramatic dosimetric consequences. Therefore, for locally advanced lung cancer patients, efforts to include image-guided treatment and to perform repeated imaging during the treatment course are recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatiotemporal Stability of Cu-ATSM and FLT Positron Emission Tomography Distributions During Radiation Therapy

Purpose: In dose painting, in which functional imaging is used to define biological targets for radiation therapy dose escalation, changes in spatial distributions of biological properties during treatment can compromise the quality of therapy. The goal of this study was to assess the spatiotemporal stability of 2 potential dose painting targets—hypoxia and proliferation—in canine tumors during radiation therapy. Methods and Materials: Twenty-two canine patients with sinonasal tumors (14 carcinoma and 8 sarcoma) were imaged before hypofractionated radiation therapy with copper(II)-diacetyl-bis(N4-methylthiosemicarbazone) (Cu-ATSM) positron emission tomography/computed tomography (PET/CT) for hypoxia and 3′-deoxy-3′-{sup 18}F-fluorothymidine (FLT) PET/CT for proliferation. The FLT scans were repeated after 2 fractions and the Cu-ATSM scans after 3 fractions. Midtreatment PET/CT images were deformably registered to pretreatment PET/CT images. Voxel-based Spearman correlation coefficients quantified the spatial stability of Cu-ATSM and FLT uptake distributions between pretreatment and midtreatment scans. Paired t tests determined significant differences between the patients' respective Cu-ATSM and FLT correlations coefficients. Standardized uptake value measures were also compared between pretreatment and midtreatment scans by use of paired t tests. Results: Spatial distributions of Cu-ATSM and FLT uptake were stable through midtreatment for both sarcomas and carcinomas: the population mean ± standard deviation in Spearman correlation coefficient was 0.88 ± 0.07 for Cu-ATSM and 0.79 ± 0.13 for FLT. The patients' Cu-ATSM correlation coefficients were significantly higher than their respective FLT correlation coefficients (P=.001). Changes in Cu-ATSM SUV measures from pretreatment to midtreatment were histology dependent: carcinomas experienced significant decreases in Cu-ATSM uptake (P<.05), whereas sarcomas did not (P>.20). Both histologies experienced significant decreases in FLT uptake (P<.05). Conclusions: Spatial distributions of Cu-ATSM were very stable after a few fractions of radiation therapy. FLT spatial distributions were generally stable early in therapy, although they were significantly less stable than Cu-ATSM distributions. Canine tumors had significantly lower proliferative activity at midtreatment than at pretreatment, and they experienced histology-dependent changes in Cu-ATSM uptake.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Arc-based smoothing of ion beam intensity on targets

Manipulating a set of ion beams upstream of a target, makes it possible to arrange a smoother deposition pattern, so as to achieve more uniform illumination of the target. A uniform energy deposition pattern is important for applications including ion-beam-driven high energy density physics and heavy-ion beam-driven inertial fusion energy (“heavy-ion fusion”). Here, we consider an approach to such smoothing that is based on rapidly “wobbling” each of the beams back and forth along a short arc-shaped path, via oscillating fields applied upstream of the final pulse compression. In this technique, uniformity is achieved in the time-averaged sense; this is sufficient provided the beam oscillation timescale is short relative to the hydrodynamic timescale of the target implosion. This work builds on two earlier concepts: elliptical beams applied to a distributed-radiator target [D. A. Callahan and M. Tabak, Phys. Plasmas 7, 2083 (2000)] and beams that are wobbled so as to trace a number of full rotations around a circular or elliptical path [R. C. Arnold et al., Nucl. Instrum. Methods 199, 557 (1982)]. Here, we describe the arc-based smoothing approach and compare it to results obtainable using an elliptical-beam prescription. In particular, we assess the potential of these approaches for minimization of azimuthal asymmetry, for the case of a ring of beams arranged on a cone. We also found that, for small numbers of beams on the ring, the arc-based smoothing approach offers superior uniformity. In contrast with the full-rotation approach, arc-based smoothing remains usable when the geometry precludes wobbling the beams around a full circle, e.g., for the X-target [E. Henestroza, B. G. Logan, and L. J. Perkins, Phys. Plasmas 18, 032702 (2011)] and some classes of distributed-radiator targets.

43 PARTICLE ACCELERATORS↗

Azimuthal distributions in radiative decay of a polarized τ lepton

We investigate various distributions over emitted photon angles, especially over the azimuthal angle, in the one-meson radiative decay of the polarized τ lepton, τ{sup –} → π{sup –}γν{sub τ}. In connection with this, the photon phase space is discussed in more detail because it is nontrivial in the case of a polarized τ lepton. The decay matrix element contains both the inner bremsstrahlung and the resonance (structural) contributions. The azimuthal dependence of some observables are calculated. They are the asymmetry of the differential decay width caused by the τ-lepton polarization, the Stokes parameters of the emitted photon itself, and the correlation parameters describing the influence of τ-lepton polarization on the photon Stokes parameters. A numerical estimation is done in the τ-lepton rest frame for an arbitrary direction of the τ-lepton polarization 3-vector. The vector and axial-vector form factors describing the structure-dependent part of the decay amplitude are determined using the chiral effective theory with resonances (RχT). It is found that the features of the azimuthal distributions allows separating various terms in the spin-dependent contribution. The so-called up–down and right–left asymmetries are also calculated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laboratory optical spectroscopy of the thiophenoxy radical and its profile simulation as a diffuse interstellar band based on rotational distribution by radiation and collisions

The gas-phase optical absorption spectrum of the thiophenoxy radical (C{sub 6}H{sub 5}S), a diffuse interstellar band (DIB) candidate molecule, was observed in the discharge of thiophenol using a cavity ringdown spectrometer. The ground-state rotational constants of the thiophenoxy radical were theoretically calculated, and the excited-state rotational constants were determined from the observed rotational profile. The rotational profile of a near prolate molecule having C {sub 2v} symmetry was simulated on the basis of a rotational distribution model by radiation and collisions. Although the simulated profile did not agree with the observed DIBs, the upper limit of the column density for the thiophenoxy radical in the diffuse clouds toward HD 204827 was evaluated to be 2 × 10{sup 13} cm{sup –2}. The profile simulation indicates that rotational distribution by radiation and collisions is important to reproduce a rotational profile for a DIB candidate and that the near prolate C {sub 2v} molecule is a possible candidate for DIB with a band width variation dependent on the line of sight.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-609: Perturbation Effects of Pedicle Screws On Radiotherapy Dose Distributions

Purpose: Radiation therapy in conjunction with surgical implant fixation is a common combined treatment in case of bone metastases. However, metal implants generally used in orthopedic implants perturb radiation dose distributions. Carbon-Fiber Reinforced (CFR) PEEK material has been recently introduced for production of intramedullary screws and plates. Gold powder can be added to the CFR-PEEK material in order to enhance visibility of the screws during intraoperative imaging procedures. In this work, we investigated the perturbation effects of the pedicle screws made of CFR-PEEK, CFR-PEEK with added gold powder (CFR-PEEK-AU) and Titanium (Ti) on radiotherapy dose distributions. Methods: Monte Carlo (MC) simulations were performed using the EGSnrc code package for 6MV beams with 10×10 fields at SSD=100cm. By means of MC simulations, dose distributions around titanium, CFR- PEEK and CFR-PEEK-AU screws (manufactured by Carbo-Fix Orthopedics LTD, Israel) placed in a water phantom were calculated. The screw axis was either parallel or perpendicular to the beam axis. Dose perturbation (relative to dose in homogeneous water phantom) was assessed. Results: Maximum overdose due to backscatter was 10% for the Ti screws, 5% for the CFR-PEEK-AU screws and effectively zero for the CFR-PEEK screws. Maximum underdose due to attenuation was 25% for the Ti screws, 15% for the CFR-PEEK-AU screws and 5% for the CFR-PEEK screws. Conclusion: Titanium screws introduce the largest distortion on the radiation dose distribution. The gold powder added to the CFR-PEEK material improves visibility at the cost of increased dose perturbation. CFR-PEEK screws caused minimal alteration on the dose distribution. This can decrease possible over and underdose of adjacent tissue and thus favorably influence treatment efficiency. The use of such implants has potential clinical advantage in the treatment of neoplastic bone disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A note of sound radiation from distributed sources

The power output from a normally vibrating strip radiator is expressed in alternative general forms, one of these being chosen to refine and correct some particular estimates given by Heckl for different numerical ratios of strip width to wave length. An exact and explicit calculation is effected for sinusoidal velocity profiles when the strip width equals an integer number of half wave lengths.

Levine, H.↗

A note on sound radiation from distributed sources

The power output from a normally vibrating strip radiator is expressed in alternative general forms, one of these being chosen to refine and correct some particular estimates given by Heckl for different numerical ratios of strip width to wave length. An exact and explicit calculation is effected for sinusoidal velocity profiles when the strip width equals an integer number of half wave lengths.

Levine, H.↗

Dosimetric and thermal properties of a newly developed thermobrachytherapy seed with ferromagnetic core for treatment of solid tumors

Purpose: Studies of the curative effects of hyperthermia and radiation therapy on treatment of cancer show a strong evidence of a synergistic enhancement when both radiation and hyperthermia modalities are applied simultaneously. Varieties of tissue heating approaches developed up to date still fail to overcome such essential limitations as an inadequate temperature control, temperature nonuniformity, and prolonged time delay between hyperthermia and radiation treatments. The authors propose a new self-regulating thermobrachytherapy seed, which serves as a source of both radiation and heat for concurrent administration of brachytherapy and hyperthermia. Methods: The proposed seed is based on the BEST Medical, Inc., Seed Model 2301-I{sup 125}, where tungsten marker core and the air gap are replaced with a ferromagnetic material. The ferromagnetic core produces heat when subjected to alternating electromagnetic (EM) field and effectively shuts off after reaching the Curie temperature (T{sub C}) of the ferromagnetic material thus realizing the temperature self-regulation. The authors present a Monte Carlo study of the dose rate constant and other TG-43 factors for the proposed seed. For the thermal characteristics, the authors studied a model consisting of 16 seeds placed in the central region of a cylindrical water phantom using a finite-element partial differential equation solver package ''COMSOL Multiphysics.''Results: The modification of the internal structure of the seed slightly changes dose rate and other TG-43 factors characterizing radiation distribution. The thermal modeling results show that the temperature of the thermoseed surface rises rapidly and stays constant around T{sub C} of the ferromagnetic material. The amount of heat produced by the ferromagnetic core is sufficient to raise the temperature of the surrounding phantom to the therapeutic range. The phantom volume reaching the therapeutic temperature range increases with increase in frequency or magnetic field strength. Conclusions: An isothermal distribution matching with the radiation isodose distribution can be achieved within a target volume by tuning frequency and intensity of the alternating magnetic field. The proposed combination seed model has a potential for implementation of concurrent brachytherapy and hyperthermia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid flattening of butterfly pitch angle distributions of radiation belt electrons by whistler-mode chorus

Van Allen radiation belt electrons exhibit complex dynamics during geomagnetically active periods. Investigation of electron pitch angle distributions (PADs) can provide important information on the dominant physical mechanisms controlling radiation belt behaviors. In this paper, we report a storm time radiation belt event where energetic electron PADs changed from butterfly distributions to normal or flattop distributions within several hours. Van Allen Probes observations showed that the flattening of butterfly PADs was closely related to the occurrence of whistler-mode chorus waves. Two-dimensional quasi-linear STEERB simulations demonstrate that the observed chorus can resonantly accelerate the near-equatorially trapped electrons and rapidly flatten the corresponding electron butterfly PADs. Finally, these results provide a new insight on how chorus waves affect the dynamic evolution of radiation belt electrons.

79 ASTRONOMY AND ASTROPHYSICS↗

Impacts of Aerosol Dry Deposition on Black Carbon Spatial Distributions and Radiative Effects in the Community Atmosphere Model CAM5

Dry deposition is a vital process affecting the lifetime and spatial distributions of atmospheric aerosols. Black carbon (BC) plays an important role in the Earth’s climate. To explore the sensitivity of modeled BC spatial distributions to particle dry deposition treatments, the scheme of Petroff & Zhang (2010) (PZ10) is implemented into the Community Atmospheric Model version 5 (CAM5), and model simulations using PZ10 are compared with the one using the default scheme of Zhang et al. (2001) (Z01). The PZ10 scheme suggests much lower dry deposition velocities than Z01 for fine particles in Aitken, primary carbon, and accumulation modes, resulting in 73.0% lower of global mean BC dry deposition fluxes and 23.2% higher of global mean BC column burdens. CAM5 with PZ10 increases modeled BC concentrations at all altitudes and latitudes compared to Z01, which improves the agreement with observations of BC profiles in the lower troposphere in the Arctic. It also helps the simulation of surface BC concentrations in high-latitudes remote regions and its seasonality in the Arctic. Yet, PZ10 slightly exacerbates the overestimation of modeled BC concentrations in the middle and upper troposphere, which might be due to model uncertainties in other aerosol physical and chemical processes. The global annual mean radiative effects due to aerosol-radiation interactions (REari) and aerosol-cloud interactions (REaci) of BC from the CAM5 experiment using Z01 are 0.61±0.007 and -0.11±0.02 W m -2 , respectively, compared to slightly larger REari (0.75±0.01 W m -2 ) and REaci (-0.14±0.02 W m -2 ) from CAM5 using PZ10.

54 ENVIRONMENTAL SCIENCES↗