Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Pupil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Neurophysiological model of the normal and abnormal human pupil

Anatomical, experimental, and computer simulation studies were used to determine the structure of the neurophysiological model of the pupil size control system. The computer simulation of this model demonstrates the role played by each of the elements in the neurological pathways influencing the size of the pupil. Simulations of the effect of drugs and common abnormalities in the system help to illustrate the workings of the pathways and processes involved. The simulation program allows the user to select pupil condition (normal or an abnormality), specific site along the neurological pathway (retina, hypothalamus, etc.) drug class input (barbiturate, narcotic, etc.), stimulus/response mode, display mode, stimulus type and input waveform, stimulus or background intensity and frequency, the input and output conditions, and the response at the neuroanatomical site. The model can be used as a teaching aid or as a tool for testing hypotheses regarding the system.

Krenz, W.

Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems

A technique was created to measure the pupil alignment of instruments in situ by measuring calibrated pupil alignment references (PARs) in instruments. The PAR can also be measured using an alignment telescope or an imaging system. PAR allows the verification of the science instrument (SI) pupil alignment at the integrated science instrument module (ISIM) level of assembly at ambient and cryogenic operating temperature. This will allow verification of the ISIM+SI alignment, and provide feedback to realign the SI if necessary.

Hagopian, John G.

Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures

Alignment of two-element telescopes is a classic problem. During recent integration and test of the Space Interferometry Mission s (SIM s) Astrometric Beam Combiner (ABC), the innovators were faced with aligning two such telescope subsystems in the presence of a further complication: only two small subapertures in each telescope s pupil were accessible for measuring the wavefront with a Fizeau interferometer. This meant that the familiar aberrations that might be interpreted to infer system misalignments could be viewed only over small sub-regions of the pupil, making them hard to recognize. Further, there was no contiguous surface of the pupil connecting these two subapertures, so relative phase piston information was lost; the underlying full-aperture aberrations therefore had an additional degree of ambiguity. The solution presented here is to recognize that, in the absence of phase piston, the Zygo measurements primarily provide phase tilt in the subaperture windows of interest. Because these windows are small and situated far from the center of the (inaccessible) unobscured full aperture, any aberrations that are higher-order than tilt will be extremely high-order on the full aperture, and so not necessary or helpful to the alignment. Knowledge of the telescope s optical prescription allows straightforward evaluation of sensitivities (subap mode strength per unit full-aperture aberration), and these can be used in a predictive matrix approach to move with assurance to an aligned state. The technique is novel in every operational way compared to the standard approach of alignment based on full-aperture aberrations or searching for best rms wavefront. This approach is closely grounded in the observable quantities most appropriate to the problem. It is also more intuitive than inverting full phase maps (or subaperture Zernike spectra) with a ray-tracing program, which must certainly work in principle, but in practice met with limited success. Even if such classical alignment techniques became practical, the techniques reported here form a reassuringly transparent and intuitive check on the course of the alignment with very little computational effort.

Bloemhof, Eric E.

Compatibility of a Diffractive Pupil and Coronagraphic Imaging

Detection and characterization of exo-earths require direct-imaging techniques that can deliver contrast ratios of 10(exp 10) at 100 milliarc-seconds or smaller angular separation. At the same time, astrometric data is required to measure planet masses and can help detect planets and constrain their orbital parameters. To minimize costs, a single space mission can be designed using a high efficiency coronograph to perform direct imaging and a diffractive pupil to calibrate wide-field distortions to enable high precision astrometric measurements. This paper reports the testing of a diffractive pupil on the high-contrast test bed at the NASA Ames Research Center to assess the compatibility of using a diffractive pupil with coronographic imaging systems. No diffractive contamination was found within our detectability limit of 2x10(exp -7) contrast outside a region of 12lambda/D and 2.5x10(exp -6) within a region spanning from 2 to 12lambda/D. Morphology of the image features suggests that no contamination exists even beyond the detectability limit specified or at smaller working angles. In the case that diffractive contamination is found beyond these stated levels, active wavefront control would be able to mitigate its intensity to 10(exp -7) or better contrast.

Bendek, Eduardo

Laboratory Performance of the Shaped Pupil Coronagraphic Architecture for the WFIRST-AFTA Coronagraph

One of the two primary architectures being tested for the WFIRST-AFTA coronagraph instrument is the shaped pupil coronagraph, which uses a binary aperture in a pupil plane to create localized regions of high contrast in a subsequent focal plane. The aperture shapes are determined by optimization, and can be designed to work in the presence of secondary obscurations and spiders-an important consideration for coronagraphy with WFIRSTAFTA. We present the current performance of the shaped pupil testbed, including the results of AFTA Milestone 2, in which approximately 6 × 10(exp −9) contrast was achieved in three independent runs starting from a neutral setting.

Cady, Eric

WFIRST Coronagraph: Digging Dark-Holes with Partially Corrected Pupil Phase

The WFIRST coronagraph employs two sequential deformable mirrors to compensate for phase and amplitude errors in the coronagraph optical system. In such a system the actuators of the deformable mirrors would be used for two purposes: To flatten the overall wavefront errors at a system pupil, and to create "dark-holes". The actuators have limited stroke ranges. Therefore, if the pupil phase errors are relatively large, flattening them completely could use up a significant portion of the actuator stroke, sometimes leaving insufficient stroke for creating the dark-holes. We have investigated the impact of partially-corrected pupil phase errors on a Hybrid Lyot Coronagraph (HLC) broadband contrast performance. The predicted broadband contrast floor and the contrast chromaticity agree well with those measured on the HLC testbed.

Poberezhskiy, Ilya

Defining Pupil Knowledge Requirements for Roman Space Telescope Integrated Payload Assembly Testing

This thesis examines the use of phase retrieval to characterize an optical system under testing conditions with pupil knowledge error. The purpose of this research is to define pupil knowledge requirements for the integrated payload testing of the Roman Space Telescope (RST). I have conducted a Monte Carlo study to determine how uncertainty in the location of the ground support equipment relative to the payload will affect the ability to use image-based wavefront sensing during the test to characterize system alignment. This test will be conducted in the Space Environment Simulator (SES) with the presence of Wavefront Error (WFE) due to gravity sag on the primary mirror. In this study, I incrementally decentered a piece of ground support equipment, the SubAperture Metrology System (SAMS), and evaluated how the phase retrieval algorithm attempted to fit the wavefront with the pupil mismatch. The results of this study are a factor in the overall Integrated Payload Assembly (IPA) testing WFE budget.

Roman Space Telescope

Design and Lessons Learned on the Development of a Cryogenic Pupil Select Mechanism (PSM)

Calibration and testing of the instruments on the Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST) is being performed by the use of a cryogenic, full-field, optical simulator that was constructed for this purpose. The Pupil Select Mechanism (PSM) assembly is one of several mechanisms and optical elements that compose the Optical Telescope Element SIMulator, or OSIM. The PSM allows for several optical elements to be inserted into the optical plane of OSIM, introducing a variety of aberrations, distortions, obscurations, and other calibration states into the pupil plane. The following discussion focuses on the details of the design evolution, analysis, build, and test of this mechanism along with the challenges associated with creating a sub arc-minute positioning mechanism operating in an extreme cryogenic environment. In addition, difficult challenges in the control system design will be discussed including the incorporation of closed-loop feedback control into a system that was designed to operate in an open-loop fashion.

PSM Design

Error analysis and corrections to pupil diameter measurements with Langley Research Center's oculometer

Factors that can affect oculometer measurements of pupil diameter are: horizontal (azimuth) and vertical (elevation) viewing angle of the pilot; refraction of the eye and cornea; changes in distance of eye to camera; illumination intensity of light on the eye; and counting sensitivity of scan lines used to measure diameter, and output voltage. To estimate the accuracy of the measurements, an artificial eye was designed and a series of runs performed with the oculometer system. When refraction effects are included, results show that pupil diameter is a parabolic function of the azimuth angle similar to the cosine function predicted by theory: this error can be accounted for by using a correction equation, reducing the error from 6% to 1.5% of the actual diameter. Elevation angle and illumination effects were found to be negligible. The effects of counting sensitivity and output voltage can be calculated directly from system documentation. The overall accuracy of the unmodified system is about 6%. After correcting for the azimuth angle errors, the overall accuracy is approximately 2%.

Fulton, C. L.

Upgrading telescopes by active pupil wavefront correction

Exit pupil correction of the Large Deployable Reflector's (a proposed IR to sub-mm space telescope) segmented primary can be done by reimaging it onto a like segmented surface at the exit pupil. This allows the primary to be more flexible, the adaptive element to be smaller, and the supporting structure to be cheaper than if all correction were performed at a stiffly supported primary. Piston, tilt, and decenter errors of an annulus of the primary and the equations for the required corrections are considered. To verify these, the perturbations with spline functions in the lens design program are simulated. Strehl ratios used to measure image quality show that a piston error of 1 mm is fully corrected over a 5 arcmin field for an f/10 system with a 0.7 n.a. primary at 30 micrometers. Limits of correction are also shown for tilt and decenter errors of segments. Tolerances are given for tilt and decenter errors of the remaining optics also.

Stacy, J. E.

Transverse Pupil Shifts for Adaptive Optics Non-Common Path Calibration

A simple new way of obtaining absolute wavefront measurements with a laboratory Fizeau interferometer was recently devised. In that case, the observed wavefront map is the difference of two cavity surfaces, those of the mirror under test and of an unknown reference surface on the Fizeau s transmission flat. The absolute surface of each can be determined by applying standard wavefront reconstruction techniques to two grids of absolute surface height differences of the mirror under test, obtained from pairs of measurements made with slight transverse shifts in X and Y. Adaptive optics systems typically provide an actuated periscope between wavefront sensor (WFS) and commonmode optics, used for lateral registration of deformable mirror (DM) to WFS. This periscope permits independent adjustment of either pupil or focal spot incident on the WFS. It would be used to give the required lateral pupil motion between common and non-common segments, analogous to the lateral shifts of the two phase contributions in the lab Fizeau. The technique is based on a completely new approach to calibration of phase. It offers unusual flexibility with regard to the transverse spatial frequency scales probed, and will give results quite quickly, making use of no auxiliary equipment other than that built into the adaptive optics system. The new technique may be applied to provide novel calibration information about other optical systems in which the beam may be shifted transversely in a controlled way.

Bloemhof, Eric E.

Design and Lessons Learned on the Development of a Cryogenic Pupil Select Mechanism Used in the Testing and Calibration of the Integrated Science Instrument Module (ISIM) on the James Webb Space Telescope (JWST)

Calibration and testing of the instruments on the Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST) is being performed by the use of a cryogenic, full-field, optical simulator that was constructed for this purpose. The Pupil Select Mechanism (PSM) assembly is one of several mechanisms and optical elements that compose the Optical Telescope Element SIMulator, or OSIM. The PSM allows for several optical elements to be inserted into the optical plane of OSIM, introducing a variety of aberrations, distortions, obscurations, and other calibration states into the pupil plane. The following discussion focuses on the details of the design evolution, analysis, build, and test of this mechanism along with the challenges associated with creating a sub arc-minute positioning mechanism operating in an extreme cryogenic environment. In addition, difficult challenges in the control system design will be discussed including the incorporation of closed-loop feedback control into a system that was designed to operate in an open-loop fashion.

Testing

Design and Lessons Learned on the Development of a Cryogenic Pupil Select Mechanism used in the Testing and Calibration of the Integrated Science Instrument Module (ISIM) on the James Webb Space Telescope (JWST)

Calibration and testing of the instruments on the Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST) is being performed by the use of a cryogenic, full-field, optical simulator that was constructed for this purpose. The Pupil Select Mechanism (PSM) assembly is one of several mechanisms and optical elements that compose the Optical Telescope Element SIMulator, or OSIM. The PSM allows for several optical elements to be inserted into the optical plane of OSIM, introducing a variety of aberrations, distortions, obscurations, and other calibration states into the pupil plane. The following discussion focuses on the details of the design evolution, analysis, build, and test of this mechanism along with the challenges associated with creating a sub arc-minute positioning mechanism operating in an extreme cryogenic environment. In addition, difficult challenges in the control system design will be discussed including the incorporation of closed-loop feedback control into a system that was designed to operate in an open-loop fashion.

Mitchell, Alissa

Laboratory and On-Sky Validation of the Shaped Pupil Coronagraph's Sensitivity to Low-Order Aberrations with Active Wavefront Control

We present early laboratory simulations and extensive on-sky tests validating of the performance of a shaped pupil coronagraph (SPC) behind an extreme-AO (Adaptive Optics) corrected beam of the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) system. In tests with the SCExAO internal source/wavefront error simulator, the normalized intensity profile for the SPC degrades more slowly than for the Lyot coronagraph as low-order aberrations reduce the Strehl ratio (S.R.) from extremely high values (S.R. approximately 0.93-0.99) to those characteristic of current ground-based extreme AO systems (S.R. approximately 0.74-0.93) and then slightly lower values down to S.R. approximately 0.57. On-sky SCExAO data taken with the SPC and other coronagraphs for brown dwarf/planet-hosting stars HD 1160 and HR 8799 provide further evidence for the SPC's robustness to low-order aberrations. From H-band Strehl ratios of 80 percent to 70 percent, the Lyot coronagraph's performance versus that of the SPC may degrade even faster on sky than is seen in our internal source simulations. The 5-sigma contrast also degrades faster (by a factor of two) for the Lyot than the SPC. The SPC we use was designed as a technology demonstrator only, with a contrast floor, throughput, and outer working angle poorly matched for SCExAO's current AO performance and poorly tuned for imaging the HR 8799 planets. Nevertheless, we detect HR 8799 cde with SCExAO/CHARIS using the SPC in broadband mode, where the signal-to-noise ratio for planet e is within 30 percent of that obtained using the vortex coronagraph. The shaped-pupil coronagraph is a promising design demonstrated to be robust in the presence of low-order aberrations and may be well-suited for future ground and space-based direct imaging observations, especially those focused on follow-up exoplanet characterization and technology demonstration of deep contrast within well-defined regions of the image plane.

Currie, Thayne

Pupil Aberrations in the LISA Transceiver Design

The LISA mission is a space-based gravitational wave detector consisting of three spacecraft with two transceiver telescopes per spacecraft. In addition to tight wavefront error control as expected for an interferometric system, there are tight pupil imaging and optical path length specifications. We use concepts gleaned from pupil aberration theory to understand these latter two constraints and show how these concepts led to a successful design for the LISA transceiver.

J. P. Lehan

Shaped Pupil Coronagraph: Disk Science Mask Experimental Verification and Testing

The Shaped Pupil Coronagraph (SPC) is one of the two operating modes of the baseline coronagraph instrument for the proposed WFIRST mission. While in SPC mode, multiple sets of shaped pupil masks and focal plane masks would be available for various imaging tasks. The disk science mask set (SPC-DSM) is designed for exozodiacal disk science. With a 360 degree high contrast field of view, extending up to 20 λ/D, the SPC-DSM provides a powerful tool to study exozodiacal dust clouds associated with stellar debris disks to gain insight of the exoplanet formation and stellar disk dynamics. We will describe the performance verification and demonstration of the SPC-DSM coronagraph as tested in the high contrast imaging testbed (HCIT) at JPL. The goal of the testbed demonstration is an average contrast of 5e-9 over a 10% bandwidth centered at 565nm, in a field of view extending from 6.5 λ/D to 20 λ/D. We will discuss electric field conjugation, performance metrics, and model agreement as applied to the SPC-DSM.

Shi, Fang

Fabrication and Characteristics of Free Standing Shaped Pupil Masks for TPF-Coronagraph

Direct imaging and characterization of exo-solar terrestrial planets require coronagraphic instruments capable of suppressing star light to 10-10. Pupil shaping masks have been proposed and designed1 at Princeton University to accomplish such a goal. Based on Princeton designs, free standing (without a substrate) silicon masks have been fabricated with lithographic and deep etching techniques. In this paper, we discuss the fabrication of such masks and present their physical and optical characteristics in relevance to their performance over the visible to near IR bandwidth.

terrestrial planet finder