Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pumped hydro storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

THESEUS: A techno-economic design, integration and downselection framework for energy storage

Optimal selection of energy storage technologies is critical to ensure reliable integration of intermittent and often uncertain renewable energy in electricity grids. The consideration of a diverse set of energy storage technologies is required for a more sustainable deployment of energy storage. We present THESEUS (TecHno-Economic framework for Systematic Energy storage Utilization and downSelection), which is a comprehensive framework for the optimal selection, design and operation of energy storage systems. THESEUS includes rigorous models of major energy storage technologies at different maturity levels, such as thermal storage using phase-change materials or molten salt, cryogenic storage, mechanical storage in the form of compressed air and pumped hydro storage, chemical storage using hydrogen, and electrochemical storage in the form of lithium-ion, sodium sulfur and vanadium flow batteries. An illustrative case study on state-wide prospective energy storage shows that storage integration with fossil power plants could reduce the cost of meeting the grid energy demand by 20%, with mechanical storage as the best suited technology. Although high-temperature thermal storage has low storage efficiency, it is optimal for integration with renewable energy plants. In addition, Li-ion batteries are optimal for high ramping but low storage duration requirements. Furthermore, such insights can enable the deployment of both existing and emerging energy storage technologies to facilitate a smooth transition to a clean energy future.

25 ENERGY STORAGE↗

A techno-economic survey of energy storage media for long-duration energy storage applications

Energy storage technologies that can economically store and provide electricity over multi-day and seasonal timescales are likely to be a critical component of a sustainable and resilient energy system. In this analysis, we perform a broad survey of energy storage technologies to find storage media (SM) that are promising for these long-duration energy storage (LDES) applications. The energy capital cost of the SM is identified as a key figure of merit for LDES. We develop a data collection framework to collect material price and physical property data, which are used to calculate the energy capital cost floor for 376 SM. These costs are then compared with cost targets for the LDES applications. The results show a multitude of thermal and chemical SM are economically promising, including some synthetic fuels, sensible thermal, latent thermal, thermochemical, and batteries based on low-cost materials. In contrast, currently deployed energy storage systems such as lithium-ion batteries and pumped hydro storage do not appear to be promising systems for LDES applications.

25 ENERGY STORAGE↗

Impact of Quaternary Pumped Storage Hydropower on Frequency Response of U.S. Western Interconnection with High Renewable Penetrations

As renewable penetration increases in the United States, maintaining stability and reliability of low-inertia power grid by providing sufficient frequency control capability becomes a challenge. Advanced pumped storage hydro technologies (APSH) will be expected to play an important role for future grid as not only an energy supplier, but also as an ancillary services provider. This paper studies the impact of using quaternary pumped storage hydropower (Q-PSH), as one of the newly proposed APSH technology, to provide primary frequency response. To quantify the impact of Q-PSH on frequency response of the U.S. Western Interconnection, a user-defined dynamic model of Q-PSH is developed on the GE Positive Sequence Load Flow (PSLF) platform and is implemented in a set of detailed U.S. Western Electricity Coordination Council (WECC) planning cases in which renewable penetration levels are 20%, 40%, 60% and 80%. Simulation results show that Q-PSH can help improve frequency nadir and settling frequency comparing to the conventional PSH.

frequency response↗

Optimization Formulations for Storage Devices with Disjoint Operating Modes

Optimizing State of Charge for Storage Resources Storage of generated energy has existed as a contributing resource within the power sector for more than a century in the case of pumped hydro storage. Even though most regional transmission organizations/independent system operators do not currently optimize state of charge (SOC) for storage, the SOC is an essential aspect of the operating characteristics of storage. This paper investigates the impact on computational performance of optimizing storage with explicit representation of SOC. To investigate the model, the paper considers two contexts, stand-alone and large-scale. Analysis of the stand-alone context helps to explain why the combination of features in the storage model results in a difficult problem. Numerical results for large-scale test cases verify that new tighter valid inequalities can improve the computation compared with the standard model in the literature.

Business & Economics↗

USAID Grid-Scale Energy Storage Technologies Primer

This work provides an overview and compares key operating characteristics of select energy storage technologies. This work explores how these storage technologies may be used to improve the flexibility and reliability of power systems given their technical characteristics. The report covers various electrochemical (lithium-ion, lead-acid, flow, sodium-sulfur), chemical (hydrogen), mechanical (pumped hydro storage, compressed air energy storage, flywheels, gravity) and electrical (supercapacitors) storage mediums.

25 ENERGY STORAGE↗

Optimal scheduling for profit maximization of energy storage merchants considering market impact based on dynamic programming

This paper analyzes how electricity merchants' market impact affects merchants' profit. Energy storage has long been studied for its role in maximizing profit, and merchant decisions are assumed to have no impact on market prices. However, the trading decisions of large-scale energy storage merchants (e.g., pumped storage hydro) will affect the market prices. This paper employs dynamic programming theory to investigate merchants' optimal economic dispatch considering the market impact and physical characteristics of storage systems. Our findings show that the State-of-Charge (SOC) based analytical solution significantly facilitates energy storage merchants' decision-making. The SOC range is segmented into three regions by two optimal SOC reference points, which depend on the available energy in storage, given prices, and market impact. By comparing the current storage SOC with the reference points, the merchant can get the corresponding optimal actions. We analytically show that if the merchant neglects the market impact on the power market, she will exaggerate her expected profit when the price-taker and price-maker merchants have the same generating and pumping upper limits offered to Independent System Operators (ISOs). Furthermore, the profit-maximizing merchant must, therefore, assay to balance the trade-off correctly between the intensity of market impact and the dispatched power. Our findings are verified by numerical simulation, and results demonstrate the ramifications for electricity merchants in energy arbitrage decisions.

25 ENERGY STORAGE↗

Hydropower Potential at Non-Powered Dams: A Multi-Criteria Decision Analysis Tool based on Grid, Community, Industry, and Environmental Impacts

Non-powered dams (NPDs) are dams that do not include hydraulic turbine (hydropower) equipment. Currently, there are more than 80,000 such dams in the United States, which provide a variety of non-energy benefits, including flood control, water supply, navigation, and recreation. Approximately 500 of these NPDs are identified as having the potential to add hydropower generation (totaling up to a capacity of more than 8200 MW). A large share of investment costs and environmental impacts of dam construction have already been incurred at these NPDs. Hence, adding power to the existing dam structure is hypothesized to be achieved at a lower cost, with less risk, and a shorter timeframe than the development required for new dam construction. The abundance of NPDs, the associated environmental favorability, and cost advantages, combined with the reliability, predictability, and dispatchability of hydropower, make NPDs a strong candidate in the nation’s renewable energy portfolio. To assess the NPD to hydropower conversion potential, in this study, we developed a GIS-based multi-criterial decision analysis tool, which allows users to rank these NPDs based on the grid, community, industry, and environmental impacts (i.e., GCIE impacts). This web-based interactive tool (developed using open-source Python and JavaScript) lets the user choose from a wide range of features to define each of the GCIE impact scores through a user-friendly graphical user interface. These features are related to dam operation, hydropower generation opportunity, power market economy, social vulnerability and risk, proximity to critical infrastructure and energy generating facilities, environmental concerns (air, water, and critical habitat), and exposure to natural hazards. The overall priority score of NPDs is calculated based on user-defined weights for each of the GCIE impact scores. Besides ranking NPDs, the tool can also be used to estimate the energy-storage feasibility (battery, hydrogen, and pump-storage hydropower) at each of the potential sites.

13 HYDRO ENERGY↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

The Effect of Clean Energy Generation Targets on the Portfolio of Electric Grid Generation Technologies

A least-cost generation and transmission expansion planning model is used to optimize the U.S. generation portfolio in 2030 under a range of Clean Energy Generation Target (CEGT) policy goals. As reference cases for comparison, the model is used to optimize the generation portfolio for the future electric grid with and without the Investment and Production Tax Credits (ITC and PTC). Next, the model is used to optimize the generation portfolio with a CEGT ranging from 10% to 70%. The results show that due to the ITC and PTC extensions by the 2022 Inflation Reduction Act, there is little additional investment in renewable energy generation assets at low CEGT levels. Significant additional installations of both renewable energy generation and energy storage systems – both batteries and pumped storage hydro – become important at CEGT levels above approximately 30%.

Aldeman, Matthew↗

Liquid Air Combined Cycle TM for Power and Storage

Liquid Air Combined Cycle (LACC) is a hybrid liquid air energy storage (LAES) system combining energy storage with a combustion turbine to enable large-scale, long-duration energy storage (LDES) while reducing fuel intensity compared to the current state-of-the-art. The LACC technical approach employs proven equipment (cryogenic refrigeration, storage, tanks, pumps, gas turbines, exhaust heat recovery equipment, and turbines) to limit technical risk to a novel organic Rankine cycle (ORC), which was evaluated during this project and found to be feasible. Moreover, LACC storage is safe and relatively compact, to facilitate siting close to loads and within metropolitan regions. The air storage medium is freely available and eliminates supply chain constraints. LACC uses cryogenic air as a storage medium and a gas turbine as the source of heat to drive the discharge process. LACC is distinguished from other LAES technologies by several factors. The charge and discharge processes are decoupled so that cryogenic liquid air is the only storage medium. Other systems also store the higher temperature thermal energy from the liquefaction process in an additional medium. Subsequently, LACC focuses on maximization of the discharge energy and power. LACC also permits the use of commercially available cryogenic refrigeration and storage technologies to increase competition. This project identified product requirements to support market entry and commercialization of the LACC in modular units of approximately 117 MW, each drawing liquid air from customary cryogenic storage tanks capable of storing 75 GWh of dispatchable energy, more than pumped storage hydro or compressed air energy storage technologies. An economic analysis identified the specific liquid air consumption (quantity of liquid air per unit of discharge energy) as a critical parameter. Minimizing the air consumption reduces the specific capital cost ($\$ $/kW) for charging and discharging equipment by reducing the size of piping and turbomachinery. Likewise, the specific cost of energy capacity ($\$ $/kWh) is reduced by increasing the energy deliverable from a given size tank. The cycle was analyzed to identify the optimal equipment selection and operating conditions, which in turn were combined with quotes and cost estimates to calculate the cost of energy from an LACC system. A substantial effort was focused on the ORC, which draws low-temperature heat from the gas turbine exhaust and condenses at low temperature using the cryogenic liquid air as a heat sink. Alternative turbomachinery arrangements were evaluated for feasibility and cost. A technology maturation plan lays out a low-risk approach to development of the novel ORC components and demonstration of LACC technology at pilot scale.

25 ENERGY STORAGE↗

Updated Baseline Cost Model for Hydropower (2023)

The "Updated Baseline Cost Model (BCM) for Hydropower" is an empirical model for estimating the costs of US hydropower projects in six categories (Non-Powered Dam (NPD), New Stream Development (NSD), Canal/Conduit, Pumped Storage Hydro (PSH), Capacity Expansion, Generator Rewind). The model equations have been estimated with data on existing or planned projects obtained from various sources. NOTE: This is a macro-enabled workbook, so Excel may block it on the first opening. In that case: 1. Save the workbook to a local directory 2. Right-click on the workbook in the local directory and select “Properties” 3. Then check “Unblock” at the bottom of the “General” tab.

13 HYDRO ENERGY↗

CERF: IM3 Projected Western US Power Plant Locations

Overview The Capacity Expansion Regional Feasibility (CERF) model is an open-source geospatial python package that provides new power plant locations at a 1km resolution. The model ingests U.S. state or regional-scale electricity system capacity expansion plans, such as those produced by the Global Change Analysis Model (GCAM-USA), and identifies feasible, site-specific locations for individual new power plants (renewable and non-renewable). CERF combines high-resolution geospatial suitability analyses with an economic algorithm that selects individual plant siting locations based on grid interconnection costs and the locational marginal value of new generation. The model incorporates a wide range of dynamic constraints and opportunities, such as protected lands, population density, existing infrastructure, and water availability. This dataset provides CERF power plant siting results for IM3 Phase 2 simulations across eight different scenarios for the Western US through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 CERF siting results in this dataset correspond to capacity expansion plans in the GCAM-USA IM3 Phase 2 simulation data and are available for each of the above scenarios. Data Details Temporal Range: 2015-2055 in 5-year timesteps. Note that 2015 is the experiment base year and 2020 and beyond represent model simulation years. Spatial Range: Plant locations are provided for the eleven states in the Western US including Arizona, California, Colorado, Idaho, Montana, New Mexico, Nevada, Oregon, Utah, Washington, and Wyoming. Spatial Resolution: 1 km-squared, provided in x and y coordinates Geospatial Projection: Albers Equal Area Conic (ESRI:102003) File Type: csv The dataset contains subdirectories for each of the eight scenarios described in the overview. Each scenario folder contains two subfolders with the following information: 1. Power Plant Data This directory contains a single .csv file of power plant locations for both pre-existing (non-CERF sited plants in operation in 2015) and new (CERF-sited) power plants across the temporal range along with additional CERF model output parameters for CERF-sited plants. Plant with a siting year earlier than 2020 correspond to facilities that are operational leading into the first timestep CERF simulation. For a more detailed description of CERF model output parameters, see the CERF model documentation. Note that the cerf_plant_id parameter is unique within each scenario file but not across scenario files. Parameter Descriptions scenario - Name of scenario cerf_plant_id - Unique siting identifier cerf_sited - If True, indicates that plant was sited by CERF model. If False, indicates pre-existing facility region_name - Name of region (state) tech_id - Technology ID tech_name - Full generation technology name inclusive of cooling type (if applicable) and additional characteristics tech_simple - Simplified generation technology type unit_size_mw - Power plant unit size (MW) xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) index - Index position in the flattend 2D array buffer_in_km - Exclusion buffer around site (km) sited_year - Year of siting retirement_year - Year of retirement lmp_zone - Locational marginal price (LMP) zone ID locational_marginal_price_usd_per_mwh - Locational marginal price ($/MWh) generation_mwh_per_year - Generation output (MWh/yr) operating_cost_usd_per_year - Cost of plant operations ($/yr) net_operational_value - Net operational value based on LMP and and operating costs ($/yr) interconnection_cost - Cost of interconnection for transmission & gas pipeline (if applicable) net_locational_cost -- Difference of interconnection cost and operating value ($/yr) capacity_factor_fraction - Capacity factor (fraction) carbon_capture_rate_fraction - Carbon capture rate (fraction) fuel_co2_content_tons_per_btu - Fuel CO2 content (tons/Btu) fuel_price_usd_per_mmbtu - Fuel price ($/MMBtu) fuel_price_esc_rate_fraction - Fuel price escalation rate (fraction) heat_rate_btu_per_kWh - Heat rate (Btu/kWh) lifetime_yrs - Technology lifetime for annuity (years) operational_life_yrs - Operational lifetime for retirement (years) variable_om_usd_per_mwh - Variable operation and maintenance costs of yearly capacity use ($/MWh) variable_om_esc_rate_fraction - Variable operation and maintenance costs escalation rate (fraction) carbon_tax_usd_per_ton - Carbon tax ($/ton) carbon_tax_esc_rate_fraction - Carbon tax escalation rate (fraction) 2. Storage Data This directory contains information on new and pre-existing energy storage facilities operational in each timestep along with various storage operational parameters. The 2015 timestep provides pre-existing energy storage data and corresponds with facilities that are operational leading into the first model simulation timestep. Note that coordinates in the storage files correspond to the interconnection point on the grid (substation location), not individual energy storage locations. Energy storage is added in a cumulative process at each given interconnection point. That is, each individual file provides the total operational storage capacity interconnected to the specified substation for the given timestep, inclusive of previously installed storage at that location and new storage installed in that timestep at that location. Parameters scenario - Name of scenario timestep - Simulation timestep name - Unique storage identifier s_typ - Type of energy storage technology (battery or pumped storage hydro) s_node - Node ID of interconnecting substation xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) charge_rate - Maximum charge rate (power capacity) of storage system (MW) discharge_rate - Maximum discharge rate (power capacity) of storage system (MW) duration - Duration of storage system (hours) max_SoC - Allowed maximum state of charge (energy capacity) of storage system (MWh) min_SoC -Allowed minimum state of charge (energy capacity) of storage system (MWh) charge_eff - Efficiency of charge (fraction between 0 and 1) discharge_eff - Efficiency of discharge (fraction between 0 and 1) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

CERF↗

WBS 1.2.3.405 - Life Cycle Assessment of Storage Technologies

Recent commitments by the Biden administration have established targets to achieve a net-zero energy system by 2050. Meeting these targets will spur a rapid transition to clean energy technologies and a commensurate need to develop and deploy energy storage technologies at scale. Pumped Storage Hydro (PSH) is expected to be part of this solution because its ability to provide grid flexibility and stability and enable the dispatching of disparate variable renewable energy technologies. Despite PSH being a mature technology with a history of deployment dating back several decades, there is very little information on the greenhouse gas (GHG) implications of PSH as compared to other storage technologies. The objective of this project is to perform a full lifecycle assessment (LCA) of new PSH projects in the U.S. This LCA includes all project phases (resource extraction, construction, operation, maintenance, end-of-life). The functional unit for this study is 1 kWh electricity delivered by system to grid substation connection point and the estimated lifetime for our base case is 80 years. Data used in this study are based on over 30 potential PSH projects that are in preliminary planning phases and are represent a wide range of potential closed-loop PSH systems in terms of location, technology, and capacity. The project approach, data sources, and modeling assumptions have been informed by a technical review committee of stakeholders that include experts from academia, national and international government, industry, and utilities. The GHGs and energy return on investment (EROI) from PSH will be compared to other storage technologies (e.g., stationary battery storage). Results from this project will improve the PSH community's understanding of the environmental impacts and sustainability of new PSH projects and how PSH compares to other storage technologies. The approach used in this project relies on open-source programming. The analysis framework (source code and data) and will be made publicly available at the end of the project. In addition to reporting results for the base case, we will perform rigorous sensitivity analysis to identify the major drivers, understand impacts of different configurations, and future energy markets. Results from this project will be published in a suitable journal.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

Regenerative Fuel Cell System (Cooperative Research and Development Final Report, CRADA Number CRD-16-635)

Grid energy storage is required to maintain reliable electricity delivery from energy producers to their customers. As electrical loads on the grid change throughout the day, stored energy supplies electricity during increased power demand periods. Further, as more renewable and alternative energy sources are added, energy storage will maximize the usefulness of these technologies. Currently, the United States has over 24.6 GW of grid storage, about 2% of the total electrical production capacity. About 95% of energy storage comes from pumped hydro. However, pumped hydro energy storage is dependent on existing geographic features, making it difficult to integrate with widespread renewable energy sources. As energy demands continue to expand, and more renewable energy (i.e. wind and solar) is added to the grid, new energy storage technologies will be needed that are not dependent on geographic features. Battery technologies can provide energy storage for some applications, but are not economically well-suited for long duration charge/discharges, such as load-leveling of renewable energy. Consequently, development of new energy storage devices will augment the existing grid and reduce the capital investment in construction upgrades. As ever-increasing mandates for renewable energy are implemented, lower-cost energy storage solutions for renewable energy will be necessary to keep electricity costs low for consumers.

13 HYDRO ENERGY↗

Progress and prospects of thermo-mechanical energy storage – A critical review

The share of electricity generated by intermittent renewable energy sources is increasing (now at 26% of global electricity generation) and the requirements of affordable, reliable and secure energy supply designate grid-scale storage as an imperative component of most energy transition pathways. The most widely deployed bulk energy storage solution is pumped-hydro energy storage (PHES), however, this technology is geographically constrained. Alternatively, flow batteries are location independent and have higher energy densities than PHES, but remain associated with high costs and low lifetimes, which highlights the importance of developing and utilizing additional larger-scale, longer-duration and long-lifetime energy storage alternatives. Here, we review a class of promising bulk energy storage technologies based on thermo-mechanical principles, which includes: compressed-air energy storage (CAES), liquid-air energy storage (LAES) and pumped-thermal electricity storage (PTES). The thermodynamic principles upon which these thermo-mechanical energy storage (TMES) technologies are based are discussed and a synopsis of recent progress in their development is presented, assessing their ability to provide reliable and cost-effective solutions. The current performance and future prospects of TMES systems are examined within a unified framework and a thermoeconomic analysis is conducted to explore their competitiveness relative to each other as well as when compared to PHES and flow battery systems. This includes carefully selected thermodynamic and economic methodologies for estimating the component costs of each configuration in order to provide a detailed and fair comparison at various system sizes. The analysis reveals that the technical and economic characteristics of TMES systems are such that, especially at higher discharge power ratings and longer discharge durations, they can offer promising performance (round-trip efficiencies higher than 60%) along with high lifetimes (> 30 years), low specific costs (often below 100 $/kWh), low ecological footprints and unique sector-coupling features compared to other storage options. TMES systems have significant potential for further progress and the thermoeconomic comparisons in this paper can be used as a benchmark for their future evolution.

25 ENERGY STORAGE↗

RODeO (Revenue Operation and Device Optimization Model) [SWR 20-67]

The Revenue, Operation, and Device Optimization (RODeO) model explores optimal system design and operation considering different levels of grid integration, equipment cost, operating limitations, financing, and credits and incentives. RODeO is a price-taker model formulated as a mixed-integer linear programming (MILP) model in the GAMS modeling platform. The objective is to maximizes the net revenue for a collection of equipment at a given site. The equipment includes generators (e.g., gas turbine, steam turbine, solar, wind, hydro, fuel cells, etc.), storage systems (batteries, pumped hydro, gas-fired compressed air energy storage, long-duration systems, hydrogen), and flexible loads (e.g., electric vehicles, electrolyzers, flexible building loads). The input data required by RODeO can be classified into three bins: 1) utility service data, which refers to retail utility rate information (meter cost, energy and demand charges), 2) electricity market data, which include energy and reserve prices, 3) other inputs, which refer to additional electrical demand, product output demand, technological assumptions, financial properties, and operational parameters.

Guerra Fernandez, Omar Jose↗

Techno-economic analysis of long-duration energy storage and flexible power generation technologies to support high-variable renewable energy grids

As variable renewable energy penetration increases beyond 80%, clean power systems will require long-duration energy storage or flexible, low-carbon generation. Here, we provide a detailed techno-economic evaluation and uncertainty analysis of applicable technologies and identify challenges and opportunities to support electric grid planning. We show that for a 120-h storage duration rating, hydrogen systems with geologic storage and natural gas with carbon capture are the least-cost low-carbon technologies for both current and future capital costs. These results are robust to uncertainty for the future capital cost scenario, but adiabatic compressed air and pumped thermal storage could be the least-cost technologies in the current capital cost scenario under uncertainty. Finally, we present a new storage system using heavy-duty vehicle fuel cells that could reduce the levelized cost of energy by 13%–20% compared with the best previously considered storage technology and, thus, could help enable very high (>80%) renewable energy grids.

25 ENERGY STORAGE↗