Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Pulsed laser operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Incident excitation effects on ZnO-based photoluminescence

Zinc oxide (ZnO) is an attractive semiconductor material owing to a wide band gap, large exciton binding energy, and strong luminescent properties. Two distinct spectral regions are present in the room temperature emission of this material: a narrow line in the UV/near-UV region that is excitonic in nature and a lower energy broad emission band centered in the green/yellow region. Commercially available ZnO particles containing excess Zn and oxygen vacancy defect sites (referred to as ZnO:Zn) were excited using three light sources to study different radiative recombination regimes of the as-received powders. First, a UV LED at a center wavelength of 365 nm provided low irradiance (0.02–0.08 W/cm 2 ) with varying pulse widths (continuous operation to 16 ns). Second, the third harmonic of a pulsed Nd:YAG laser provided high irradiances (∼10 4 –10 6 W/cm 2 ) at a fixed nominal pulse width of 5 ns. Finally, a continuous polychromatic synchrotron X-ray source was also used to excite the ZnO:Zn powders. During UV LED excitation, a low number of carriers are created in the material, leading to an anticipated linear relationship between luminescence and irradiance. This held true for defect luminescence; however, there was an observed enhancement of exciton emission relative to the UV LED intensity as the pulse width was decreased, independent of irradiance. During UV laser excitation, the number of carriers was significantly increased, raising the material into a bimolecular recombination regime, which produced exciton emission much stronger than visible band emission. Finally, spectra obtained during synchrotron X-ray excitation, whose continuous illumination and higher penetration depth yielded higher emission from defect sites relative to exciton emission. A redshift in the exciton emission was also observed as excitation pulse width and sample temperature were varied, and is discussed.

Westphal, Eric Robert [Sandia National Lab. (SNL-N

Quantum Information for Fusion Energy Sciences (Final Technical Report)

The simulation of plasma dynamics is a critical area of Fusion Energy Sciences (FES) due to it’s usefulness in predicting, controlling, and confining plasmas in the context of potential fusion reactors. The simulation of plasmas is a computationally difficult problem in both classical and quantum physics, motivating investigation into the potential of quantum computers to simulate these systems. This project took several concrete steps towards this goal by developing tools for improving the control, characterization, and calibration of quantum gates on a superconducting quantum computer, developing error suppression and mitigation tools to reduce errors on the quantum computer, and utilizing these advancements to simulate reduced models of plasma dynamics on the quantum computer. In order to efficiently simulate plasma physics, an optimal control method which synthesizes, directly at the pulse level, any quantum gate on qubit and qutrit systems was developed. Using four superconducting transmon quantum processors at Rigetti and LLNL, it was demonstrated that any arbitrary quantum gate on qubits and qutrits could be implemented with high fidelity, leading to a significantly reduced length of a gate sequence. A problem of interest in FES is the nonlinear optical process of laser pulse compression within a plasma. Since quantum physics is linear, simulating nonlinear operations is not naturally feasible on a quantum computer, however it is possible to simulated a quantized version of the nonlinear process. A quantization approach to convert nonlinear wave-wave interaction problems to Hamiltonian simulation problems was developed and demonstrated using two qubits on a Rigetti device. In this experiment, a number of error suppression and mitigation techniques were investigated to determine how best to utilize the finite quantum resources. This study provides an example of how plasma problems may be solved on near-term, noisy quantum computing platforms and identified a promising set of techniques. Building on the insights of these experiments, the investigation turned to linear electron-plasma wave physics. A connection was identified between a local one-dimensional lattice spin model and linear wave phenomena, allowing a plasma physics problem to be efficiently mapped to the quantum computer. In this framework, reflection and transmission of plasma waves at a sharp boundary was studied, as well as the propagation of waves through an inhomogeneous plasma medium. In addition to the suite of error suppression and mitigation techniques developed, this experiment introduced the use of a digital-analog gate scheme designed to efficiently simulate the plasma Hamiltonian. With hardware available at the conclusion of the project, simulation at the scale of 9 qubits and 15 timesteps (60 entangling layers) was achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Entropy-mode-driven gas optics

We propose a class of gaseous diffractive optical elements created by imprinting an entropy mode in a gas. Previous approaches to gaseous diffractive optics have relied on the simultaneous excitation of a standing acoustic wave and an entropy mode to produce one-dimensional periodic structures. However, the presence of acoustic oscillations in the gas imposes stringent constraints on some of the operational parameters of these optical elements, such as their lifetime and diffraction angle. Here, in this work, we introduce an approach that eliminates the acoustic mode, relying solely on the entropy mode. This enables control of the lifetime and temporal profile of gaseous optical elements, and also allows the creation of arbitrary structures with greater contrast, including nonperiodic patterns such as chirped gratings or lenses. This approach should allow operation over a wider parameter space, including larger diffraction angles and compatibility with laser pulse durations ranging from femtoseconds to microseconds.

Optics and optical instruments

Economic Analysis of the NIF Optics Recycle Loop Systems Investment Options: SAE 560 - Economic Considerations for Systems Engineering at University of Southern California

The National Ignition Facility (NIF) relies on large-scale precision optics to deliver high-energy laser pulses for fusion and high-energy-density physics research; however, the NIF routinely operates above the damage threshold for those optics, decreasing their effectiveness with every experiment. A production line composed of several dozen highly specialized processing systems, collectively referred to as the ‘optics recycle loop’, was established to support refurbishment and re-use of these critical components to reduce reliance on high-cost and high-risk optic replacement strategies. This analysis aims to identify the most cost-effective investment options for improving recycle loop throughput by maximizing availability and production flexibility while minimizing the engineering and infrastructure efforts and cost.

42 ENGINEERING

Flashlamp drive system for a high-energy 10–100 kHz pulse-burst Nd:YAG laser

We present the design of the flashlamp drive system for the NG100 laser, a 1 J/pulse, 10–100 kHz, pulse-burst Nd:YAG laser system being developed for application in a Thomson scattering plasma diagnostic. This flashlamp drive system is under active development, with a prototype now being constructed. The flashlamp drive system is modular, with each module capable of driving a series pair of linear flashlamps. Each drive module contains and is controlled by a dedicated Analog Regulator Controller. Thus each module is independently operable and controllable. This modular approach imposes no intrinsic limit to the number of modules that may be applied to drive the flashlamp pairs in a laser system. Each flashlamp drive module has a switch-regulated topology. An 1800 V main capacitor bank provides 25 kJ of energy storage, while a lower voltage output capacitor bank provides filtering and the initial energy delivered to the flashlamps at the start of the drive pulse. The main bank is recharged after each flashlamp drive pulse. As energy is drawn from the output bank by the flashlamps, an IGBT switching regulator feeds current from the main bank through an inductor to replenish the output capacitor bank. The rate of replenishment is feedback-controlled to maintain a regulated supply of power to the flashlamp load, with a setpoint range of 0.07 to 1.65 MW. An Analog Regulator Controller produces two-state variable pulse width feedback switching of the regulator IGBT. The switching frequency is ≤ 20 kHz, dynamically adjusted to limit ripple of the flashlamp power to ±3% statistical standard deviation of mean. For development or troubleshooting, each module is operable independent of the laser digital control system (microcontroller and FPGA).

Plasma diagnostics - interferometry

Tailoring coherent beam combined laser pulse trains for high peak and average power applications

Laser systems based on coherent beam combination (CBC) that rely on tiled pupil architecture intrinsically carry digital capabilities independently applicable to all three essential characteristics of a laser pulse: amplitude, phase and polarization. Those capabilities allow the far-field energy distribution to be flexibly tailored in real time. Operation in the femtosecond regime at high repetition rates gives access to a wide range of applications requiring both high peak and average powers. We address the task of independent peak versus average power adjustment needed for applications seeking to decouple nonlinear phenomena associated with GW peak power from the thermal load inherent to kW average power operation. The technical solutions proposed are presented in the framework of the Ecole Polytechnique XCAN CBC laser platform (61 independent channels) with an emphasis on thermal management measures implemented to ensure its nominal operation.

47 OTHER INSTRUMENTATION

Design of a non-invasive laser-based beam profile monitor system for the new Fermilab PIP-II superconducting H- linac

As part of the new Proton Improvement Plan (PIP-II), Fermilab is undertaking the development of a new 800 MeV, 2 mA H- superconducting RF linac to replace its present normal conducting 400 MeV linac. The PIP-II linac consists of a series of superconducting RF cryomodules from 2.1 MeV to 800 MeV. To limit the potential damage to the superconducting RF cavities, PIP-II will utilize non-invasive laser-based monitors (laserwires) to obtain beam profiles via photoionization. This paper will present the design of this PIP-II laserwire system including the picosecond pulsed laser, optical transport line, 13 individual laserwire stations, laser feedback and timing controls. The paper also describes the signal detection system and operation of the profile measurements.

Scarpine, Victor [Fermilab]

Sub-Nanosecond, Room-Temperature, Mid-IR Fe:ZnSe Gain-Switched Laser: Experimental Characterization and Modeling

We present the modeling and experimental characterization of a room-temperature, sub-nanosecond, gain-switched (GS) Fe:ZnSe laser operating at 4.4–4.8 μm. As pump sources, we used a 2.79 µm Q-switched Cr:Er:YSGG laser with a pulse duration of 52 ns and the 2.98 μm idler of a Nd:YAG pumped KTA-OPO system with a pulse duration of 9 ns. The shortest pulse durations were measured to be 1.4 ns and 0.7 ns under excitation by the Cr:Er:YSGG laser and KTA-OPO system, respectively. The developed Fe:ZnSe laser model showed good agreement with the experimental results. Optimization of the laser parameters based on model simulations suggests that an Fe:ZnSe microchip laser configuration could be achieved with a pulse duration of ~250 ps and an efficiency of ~20%.

Ghimire, Saugat

ElementLIBS User's Guide: An operational aid for use and development

Laser-Induced Breakdown Spectroscopy or LIBS is a rapid, in-situ analytical technique where a laser of known energy is pulsed at the surface of an analyte. The laser pulse rapidly heats a localized area to many thousand degrees Kelvin, ablating part of the analyte and turning it into a plasma. As the plasma cools, excited atoms return to a ground state with known emission energies. This emitted energy is captured by various spectrometers and provides a spectrum of the emitted energies and intensities. This spectrum can be analyzed to provide the elemental composition of a sample by using known emission lines and relative abundance. ElementLIBS was developed for the SciAps hand-held LIBS model Z300 but will work with any model that provides a LIBS spectrum of similar resolution. The Z300 has an integrated resolution of 1/30 nm with a range of approximately 180nm – 960nm, providing an output spectrum of 23431 pixels across three spectrometers. These criteria are only provided as a reference, as the software was designed to work with any size spectrum, provided the input file is of the correct format and the models were developed using the same framework. If spectra of varying dimensions are used, the software will fail without warning and unusual events could occur.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Pulse-by-pulse transient thermal deformation in crystal optics under high-repetition-rate FEL

Time-domain modeling of the thermal deformation of crystal optics can help define acceptable operational ranges across the pulse-energy repetition-rate phase space. In this paper, we have studied the transient thermal deformation of a water-cooled diamond crystal for a cavity-based X-ray free-electron laser (CBXFEL), either an X-ray free-electron laser oscillator (XFELO) or a regenerative amplifier X-ray free-electron laser (RAFEL), by numerical simulations including finite-element analysis and advanced data processing. Pulse-by-pulse transient thermal deformation of a 50 µm-thick diamond crystal has been performed with X-ray pulse repetition rates between 50 kHz and 1 MHz. Results for temperature and thermal deformation have been compared with the results of transient analysis using a continuous wave (CW) power loading. Temperature and thermal deformation results from pulse-by-pulse transient analysis vary with time about the results for the CW case for the same average power. The variation amplitude increases with pulse energy and decreases with repetition rate. When the repetition rate increases to infinity, both temperature and thermal deformation converge to the results for the CW case. Two critical time scales for the operation of crystal optics in a CBXFEL are (1) first-turn time, i.e. the time for the XFEL pulse to complete the first turn around the cavity so that the crystal sees the recirculated XFEL pulse, and (2) period-end time, i.e. the time that the next electron bunch arrives for the amplification, so that the crystal outcouples the amplified FEL power. For the same average power, simulation results show that the crystal thermal deformation seen by the XFEL beam decreases with repetition rate at the first-turn time of a 300 m-long cavity and increases with repetition rate at the period-end time. For the wavefront preservation requirement of the crystal optics, a pulse-energy versus repetition-rate phase space has been established. The upper bounds of the pulse energy at both first-turn and period-end times decreases with repetition rate, especially at the period-end time. The upper bound of the thermal deformation of the crystal at the period-end time for any repetition frequency can be estimated from the CW case. For a water-cooled diamond crystal of dimension 5 mm × 5 mm × 0.05 mm, the time to reach a quasi steady-state is about 50 ms for temperature and 50 µs for thermal deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Nonlinear regenerative amplification using tunable intracavity cascaded quadratic nonlinearities

Conventional nonlinear regenerative amplification utilizes Kerr (i.e., self-focusing) nonlinearity to broaden the spectrum via self-phase modulation during the direct amplification of ultrashort pulses, which helps overcome spectral gain narrowing for high-energy, ultrashort-pulse generation. We introduce cascaded quadratic nonlinearities from a type-I second-harmonic generation crystal, which can be tuned in both magnitude and sign via the phase-mismatching condition, inside a regenerative amplifier to enable nonlinearity-tunable regenerative amplification. We demonstrate, both experimentally and numerically, a nonlinear Yb:YAG thin-disk regenerative amplifier with either positive or negative net nonlinearity that delivers 1-kHz, >0.4-mJ pulses as short as ∼200 fs and high-quality beams free of self-focusing. The laser’s average power can be scaled to >100 W when seeded and operated at a much higher repetition rate to benefit various applications.

47 OTHER INSTRUMENTATION

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER

Predicting Pulsed-Laser Deposition SrTiO 3 Homoepitaxy Growth Dynamics Using High-Speed Reflection High-Energy Electron Diffraction

Pulsed-laser deposition (PLD) is a powerful technique for growing complex oxides with controlled stoichiometry. To understand growth dynamics therein, it is common to leverage in situ spectroscopies, such as reflection high-energy electron diffraction (RHEED), to monitor surface crystallinity. Most commercial systems rely on video-rate cameras operating at 60-120 Hz that lack sufficient temporal resolution to capture growth dynamics at practical deposition frequencies. Here, a high-speed platform to record in situ dynamics via RHEED at >500 Hz is implemented. An open-source analysis package is designed to fit diffraction spots to 2D Gaussians, allowing single-pulse surface reconstruction kinetics extraction. Using homoepitaxially deposited (001)-oriented SrTiO 3 as a model system, we demonstrate how high-speed RHEED can provide real-time insight into growth processes obscured by slower acquisition systems. By fitting the single-pulse intensity to a set of exponential functions, we observe changes in the characteristic decay time and mechanism correlated to the substrate step width and surface termination. We observe distinct surface effects, with diffraction intensity decaying on lower-energy TiO 2 -terminated surfaces and stabilizing on SrO- or mixed-terminated surfaces. Similarly, using an exponential model, the extracted characteristic time of adatom deposition decreases with increased density of bonding sites associated with mixed termination and narrower step widths. Ultimately, this work shows how increasing RHEED temporal resolution can uncover new insights into growth processes, with practical implications for the design and control of PLD processes. This experimental platform provides new capabilities to enable data-driven machine learning analysis and autonomous control systems to enhance the complexity and fecundity of PLD.

(SrO)

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N

Electrons and Their Multiple Kinetic Fates in an Ionic Liquid

Ionic liquids (ILs) for electrochemical, nuclear, and solar energy applications operate under harsh conditions, where electrons and transient radical species can form. This communication discusses why anions such as bis(trifluoromethylsulfonyl)imide (Tf 2 N − ) are reduced at the electron-rich electrode whereas in laser photoionization or pulse radiolysis studies, where electrons are ejected from species in the bulk, we often detect long-lived electrons in cavities that interact with IL cations instead. This work argues that bulk excess electrons generated photolytically or radiolytically follow kinetically favored pathways. As such, cavity electrons may not be the most energetically favorable states, but when they form, and they do form, they are kinetically stable. Reduction reactions of anions or electron localization in cavities and subsequent reactions are all expected outcomes. Here we focus on a pyrrolidinium-based IL of the dicyanamide (N(CN) 2 − ) anion because of its large electrochemical window and very low viscosity, which are ideal for energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Stable and tunable MeV $$\gamma$$-ray generation via dual-laser inverse Thomson scattering from a laser-plasma accelerator

Abstract Inverse Thomson scattering from laser-plasma accelerators offers a pathway to compact, tunable MeV $$\gamma$$ -ray sources for reduced-dose radiography and enhanced performance in nuclear resonance fluorescence (NRF)-based isotope identification. However, photon yield and spectral quality are often limited by constraints on interaction geometry and scatter-laser tunability. Here we demonstrate a MeV $$\gamma$$ -ray source based on a dual-laser inverse Thomson scattering configuration driven by a 100-TW laser-plasma accelerator. Electron beams tunable from 122 to 204 MeV with $$<5$$ mrad divergence and $$<1$$ mrad pointing stability generate $$\gamma$$ rays with peak energies from 276 keV to 1.2 MeV and yields up to $$2\times 10^{7}$$ photons per shot. By independently controlling the interaction position and the scatter-pulse duration, we experimentally match the scatter pulse to the walk-off-limited interaction length. Extending the scatter pulse to 200 fs increases photon production by approximately $$15\%$$ while maintaining operation in the linear Thomson regime, thereby preserving narrow spectral bandwidth and controlled radiation divergence. Radiographic characterization demonstrates MeV-level penetration and $$\approx 0.1$$ mm spatial resolution, while stable operation is sustained over multi-hour timescales across multiple days. These results show that interaction-length optimization provides a scalable strategy for improving photon yield, spectral control, and operational stability in compact laser-plasma-accelerator-driven $$\gamma$$ -ray sources.

Tsai, Hai-En

Tunable Metasurface External-Cavity Quantum Cascade Lasers up to 5.74 THz

Vertical-external-cavity surface-emitting lasers based on amplifying quantum-cascade metasurfaces are demonstrated in the 5–6 THz range for the first time. Enhanced parasitic coupling to lossy surface modes requires updated design guidelines, while elevated losses and lower available material gain limit the scaling of the metasurface period from previous designs. A series of metasurface devices with varying periods employing both uniform and focusing metasurfaces is fabricated and characterized. Reducing the metasurface period below 70% of the free-space wavelength enables devices with superior performance, achieving pulsed operation up to 5.74 THz with peak output powers of 1.3 mW, maximum operating temperatures up to 83 K, and continuous-wave operation up to 54 K with 23 μW of output power. In the best case, single-mode tuning from 5.23–5.73 THz, which corresponds to a 9.1% fractional tuning, is realized with near-Gaussian far-field profiles maintained across the entire range. Finally, these results establish quantum cascade vertical-external-cavity surface-emitting lasers as promising candidates for high-frequency local oscillator applications in heterodyne spectroscopy.

gallium arsenide

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES