Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pu isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

IER - 551: Experiment for Unresolved Resonance of Plutonium Actinides (EUROPA): CED-1 for True Intermediate Pu Benchmark

IER-551 or the Experiment for Unresolved Resonance Of Plutonium Actinides (EUROPA), is an experiment campaign to design and execute a series of true intermediate energy plutonium critical configurations. EUROPA is a collaboration between Los Alamos National Laboratory (LANL), Oak Ridge National Laboratory (ORNL), and the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN) to validate current and future evaluations of 239,240 Pu isotopes. Preliminary designs were optimized using Particle Swarm Optimization to save on computation time and the configuration with highest percentage of intermediate neutrons causing fission found was BeO-Cd. This combination has over 70% of fissions occurring from intermediate energy neutrons. Secondary considerations regarding end benchmark uncertainties and quality of nuclear data resulted in a beryllium metal only experiment proposed as the final system. This final preliminary design achieves 68% intermediate fissions, sensitivities of fission and capture cross sections of 239 Pu of 0.3021 and -0.1610 respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Strategies for thorium fuel cycle transition in the SD-TMSR

Liquid-fueled Molten Salt Reactor (MSR) systems represent advances in safety, economics, and sustainability. The MSR has been designed to operate with a Th/ 233 U fuel cycle with 233 U used as startup fissile material. Since 233 U does not exist in nature, we must examine other available fissile materials to start up these reactor concepts. This work investigates the fuel cycle and neutronics performance of the Single-fluid Double-zone Thorium-based Molten Salt Reactor (SD-TMSR) with different fissile material loadings at startup: High Assay Low Enriched Uranium (HALEU) (19.79%), Pu mixed with HALEU (19.79%), reactor-grade Pu (a mixture of Pu isotopes chemically extracted from Pressurized Water Reactor (PWR) spent nuclear fuel (SNF) with 33 GW d/tHM burnup), transuranic elements (TRU) from Light Water Reactor (LWR) SNF, and 233 U. The MSR burnup routine provided by SERPENT-2 is used to simulate the online reprocessing and refueling in the SD-TMSR. The effective multiplication factor, fuel salt composition evolution, and net production of 233 U are studied in the present work. Additionally, the neutron spectrum shift during the reactor operation is calculated. The results show that the continuous flow of reactorgrade Pu helps transition to the thorium fuel cycle within a relatively short time (≈ 4.5 years) compared to 26 years for 233 U startup fuel. Finally, using TRU as the initial fuel materials offers the possibility of operating the SD-TMSR for an extended period of time (≈ 40 years) without any external feed of 233 U.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High efficiency laser resonance ionization of plutonium

Three-step resonance photoionization spectra of plutonium have been studied with Ti:Sapphire lasers for the development of efficient laser ionization schemes for ultra-trace analysis of Pu isotopes by resonance ionization mass spectrometry. We observed eighteen intermediate excited states of even parity in the energy range 35568–36701 cm -1 , thirteen of them have not been previously documented, and a larger number of high-lying excited states and autoionizing states of odd-parity between 48238 and 49510 cm -1 . Three-color, three-photon ionization schemes via six intermediate states were evaluated under similar ion source operating conditions. This led to a highly efficient three-step scheme with an overall ionization efficiency of 51.1±1.3%, which is an order of magnitude improvement over the previously reported ionization efficiency for Pu.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy dependence of chain fission product yields from neutron-induced fission of 235 U, 238 U, and 239 Pu

The lack of completeness and systematic studies of cumulative fission product yield (FPY) from the three major actinides of 235 U, 238 U, and 239 Pu, over a broad energy range, was the primary motivation for the LLNL-LANL-TUNL collaboration. Given the focus on resolving FPY behavior around fission spectrum neutron energies, our 2016 data provides FPY measurements in fine energy steps in the range of 0.5–5.5 MeV and an additional anchor point at 14.8 MeV. Recently, our collaboration filled the gap between second chance fission and 14.8 MeV, providing a comprehensive study at eleven incident neutron energies from 0.5 to 14.8 MeV. However, during the course of the last measurements, it was found that the reported masses of the actinide deposits in the fission ionization chambers, which were used to measure the number of fissions, were not consistent with the complementary tests. Therefore, some corrections to the old data are needed. The purpose of this paper is to summarize all of the high-yield FPY data obtained for 235 U, 238 U, and 239 Pu isotopes using quasi-monoenergetic neutron beams at 11 incident energies ranging from E n = 0.5 to 14.8 MeV.

Tonchev, A. P. [Lawrence Livermore National Labora↗

The calculation of light element impurity (α, n) yield curves in a PuO 2 matrix and associated specific yield coefficients: Influence of the reaction cross sections

Most of the Pu separated from irradiated commercial nuclear fuel is stored as PuO 2 . The primary quantitative nondestructive measurement technique used to verify the amount of Pu in storage containers is passive neutron correlation counting. An important physical property of the oxide material is the ratio, α, of the rate of (α, n) neutrons produced inside the item to the rate of neutrons produced by spontaneous fission. This ratio influences the precision of the correlated counting method and affects the interpretation of the data because of how it changes both the primary total neutron production rate and the rate of induced fission events taking place inside the item. In addition to the main O(α, n) contribution, additional contributions come from α-particle interactions with light element impurities that are inevitably present. In this work, we calculate specific (α, n) yield coefficients, expressed in units of neutrons per second per gram of α-emitting nuclide per part per million by mass of the specified impurity element distributed in a pure PuO 2 matrix, for some key α-emitting actinides commonly present in reprocessed Pu ( 238–242 Pu+ 241 Am). These coefficients are directly applicable to nuclear safeguards verification work in which the α ratio is often calculated from the Pu-isotopic composition and chemical information obtained by other means. Further, they also provide a convenient up-to-date reference set against which values generated by other methods can be compared. Results are presented for impurities with atomic number from 3 to 17 inclusive, plus K and Fe. In most cases, these coefficients are not expected to change by more than 5%–10% at any time in the future. However, as new data become available, changes as large as 20% may be needed for some targets (e.g., F). The present yield calculations are limited by the general shortage of quality experimental total (α, n) reaction cross section data, which, together with unexplained variation between determinations, means that an objective and coherent evaluation is not possible. The situation is even less satisfactory for the partial differential cross section needed to calculate neutron spectra.

(𝛼, n) reactions↗

A multi-collector ICP-MS method for quantification of plutonium, uranium, and americium in hair and nails of occupationally or medically exposed individuals

The 239 Pu, 238 U, and 241 Am concentrations and 239 Pu/ 240 Pu, 235 U/ 238 U, and 236 U/ 238 U atom ratios were measured in the hair and nail samples from individuals who donated their bodies to the United States Transuranium and Uranium Registries. Further, the concentration of 239 Pu ranged from 0.22–15.8 ng/kg. The 240 Pu/ 239 Pu isotopic ratios ranged from 0.026 to 0.127 which is consistent with weapons-grade plutonium. Concentration of uranium fell between 1.84 µg/kg and 29.5 µg/kg and 235 U/ 238 U ratios ranged from 4.8×10 -3 to 7.6×10 -3 . Elevated 236 U/ 238 U atom ratios were measured in two cases and ranged from 5.0×10 -6 – 2.4×10 -5 indicating exposure to spent or reprocessed uranium material. The concentration of 241 Am was measured in four hair samples and ranged from 0.02–0.21 ng/kg.

61 RADIATION PROTECTION AND DOSIMETRY↗

Energy dependence of fission product yields in the second-chance fission region

An extensive dataset of cumulative fission product yields has been generated under a joint collaboration between Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and the Triangle Universities Nuclear Laboratory (TUNL). The energy dependence of the cumulative yield for a select number of high-yield fission products has been measured using quasimonoenergetic neutrons with energies between 5.5 and 11.0 MeV. This is in addition to previously published data covering 0.5–4.5 and 14.8 MeV. The absolute number of fissions was determined during the irradiation period using dual-fission ionization chambers, and the fission products were measured postactivation by whole target γ-ray spectroscopy. Here this paper presents the absolute cumulative fission product yields as a function of incident neutron energy from the neutron-induced fission of 235 U, 238 U, and 239 Pu isotopes at four incident energies in the second-chance fission region and compares them with existing literature values. Corrections relevant to this collaboration's previously published data are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Critical and Californium Source-Driven Noise Analysis Subcritical Measurements with an Unreflected Cylindrical Tank of Mixed Uranium-Plutonium Nitrate Solution

The reported experiments were performed by Oak Ridge National Laboratory (ORNL) at the Battelle Northwest Laboratory’s (now Pacific Northwest National Laboratory) critical experiments facility at Hanford, Washington in 1981 and used 16 days of critical facility time, not including 10 days for setup and removal of ORNL equipment. These measurements were to assess the capability of the Cf source-driven noise analysis (CSDNA) method to measure the subcriticality (keff) of mixed U-Pu nitrate solutions. In addition to the CSNDA measurements, measurements were also performed near delayed criticality where CSDNA measurements cannot be performed. This report documents the experiments that were not reported at that time by presenting the ORNL experimental results and any online analysis performed during and shortly after the measurements. The mixed nitrate solution had a U concentration at 188 grams per liter (g/L), a Pu concentration of 280 g/L, free acid normality of 2.80, H ion molarity of 5.9 and a specific gravity of 1.754 g/cm 3 , a 240 Pu isotopic content of 7.981 wt. %, and a 235 U isotopic content of 0.724 wt. %. The stainless-steel tank for the solution had an inside diameter of 35.38 cm, an outside diameter of 35.53 cm, a height of 56.72 cm, and bottom thickness of 0.9525 cm. A Zircaloy pipe with a 3.1496 cm outside diameter, a 2.7788 cm inside diameter, and bottom thickness of 0.635 cm was available for insertion of the Cf source in the center of the fissile solution. The Cf source was also located at the outside surface of the tank (solution height varied from 10 to 53 cm) and in the center of the solution (solution height varied from 10 to 60.7 cm). The CSDNA measurements were not analyzed online to determine the subcritical neutron multiplication factors. At all subcritical states, the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. The neutron multiplication factors were determined for the two configurations of the measurements near delayed criticality. The subcritical neutron multiplication factors from the CNSDA measurements can be obtained with further analysis. However, the near delayed critical configuration, the prompt neutron decay constants, the count rates, and the measured cross and auto power spectral densities can be calculated directly for benchmarking. Much of data presented in this report are from ORNL notes—not in the ORNL logbooks. For the final benchmark analysis, the data from the Battelle Northwest Laboratory (which operated the critical facility in 1981) critical facility logbook should be consulted and be incorporated where appropriate. The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Program (ICSBEP) or Nuclear Energy Agency benchmark. The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

14 MeV Irradiation and Analysis of a 93% 239 Pu Target in Preparation for a F2019 FY22 Pu Campaign

In this work, we present the irradiation of a 93% 239 Pu with 14 MeV neutrons and subsequent analysis of the fission and activation products. The fully assembled target, a Pu metal bead encapsulated in Al, further encapsulated in welded stainless steel, was analyzed 22 times over more than 100 days using gamma emission analysis (GEA). Using the results from these analyses, R-values and fission yields for fission products were determined. To prepare for the FY22 Pu irradiation using the GODIVA critical assembly at NCERC, the irradiated Pu target was disassembled, dissolved, and separated using chemistry provided by LANL collaborators. This chemical separation was intended to remove the Pu from solution with little to no effect on the remaining elements. The chemistry was assessed to try to determine possible routes of fractionation of the sample and the fission products. The separation process used was successful for the bulk of the analyzed fission and activation products, as well as the added radiotracers. The final dissolved solution and separated fractions were analyzed by GEA looking at the remaining fission, activation and radiotracers and thermal ionization mass spectrometry analysis looking at the Pu isotopics.

14MeV↗

Assessment of Evaluations for 239 Pu Photonuclear Cross Sections

We have performed an initial assessment of available data libraries for photonuclear reactions on 239 Pu. Specifically, we considered the following five evaluated data libraries: the ENDF/B-VIII.0 and the recently deployed ENDF/B.VIII.1 Evaluated Nuclear Data Files, the International Atomic Energy Agency (IAEA) Photonuclear Data Library 2019 (IAEA-2019), the Japanese evaluated nuclear data library version 5 (JENDL-5), and the 2023 version of the TALYS Evaluated Nuclear Data Library (TENDL-2023). Each of these libraries were translated form ENDF to GNDS format using FUDGE. For each of the Pu isotopes, we provide a comparison with available experimental data in the EXFOR experimental nuclear reaction database, as well as a rapid quantitative assessment of the quality of the evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gamma Spectrometry Code Rodeo for Uranium Enrichment—FY 2021 Report

In FY22, the participating Department of Energy (DOE) laboratories continued the work on the project “Gamma Spectrometry Code Rodeo for Uranium Enrichment”. Oak Ridge National Laboratory (ORNL) and Lawrence Livermore National Laboratory (LLNL) continued their efforts to acquire spectra using uranium sources. A collimator (with side and back shields) was custom designed and constructed at ORNL. Spectra were acquired at ORNL using the uranium enrichment standards supplied by New Brunswick Laboratory (NBL) and the collimated M400 detector. Spectra were also acquired using steel absorbers of different thickness placed between the source and the collimated M400 detector. The plan was to ship the collimator to LLNL so that spectra could be acquired using the LLNL detector in collimated geometries. This activity was suspended since problems were noticed with the performance of the LLNL M400 detector. Also, it was brought to light to the project team that some of the aspects of the M400 detector had been updated by the vendor H3D in response to requests by the IAEA. In February 2021, the ORNL and LLNL M400 detectors were returned to the H3D factory in order to resolve the problems with the LLNL detector and to update ORNL and LLNL detectors to the same configuration as the M400 supplied to the IAEA. H3D repaired the LLNL M400 and performed the IAEA updates on both the ORNL and LLNL detectors. ORNL and LLNL received the detectors in April 2021. Data acquisition was continued using the upgraded detectors. ORNL re-collected the spectra using point sources and the NBL standards in uncollimated and collimated geometries. The collimator was shipped from ORNL to LLNL. Spectra were acquired at LLNL through Q4 of FY22. When the ORNL spectra were examined closely, it became apparent that there were spurious artifacts present in some of the spectra. This rendered suspect the ORNL spectra collected in June/July 2021 time frame. ORNL contacted H3D and per H3D’s advice, the M400 detector was returned to H3D for repairs in mid-August 2021. H3D diagnosed the problem and established that the root cause was the extra tight packaging that created a strain on the CZT crystals, causing one of them to break down. The repaired M400 was returned to ORNL in early September 2021. ORNL re-started data acquisition for the third time. Data was continued to be acquired at ORNL and LLNL through September 2021. The ORNL and LLNL data will be shared with the principal investigators from the analyzing laboratories. The GADRAS code and FRAM have been developed to have the capability to analyze the M400 spectra. Good quality spectra from FY21 have been analyzed using modified versions of GADRAS and FRAM. The spectra have also been analyzed using the GEM code. The analysis results from GADRAS, FRAM and GEM codes are presented and discussed in this report. Some preliminary results from FRAM and GEM analysis were presented in February 2021 at the U-Pu Isotopics Workshop sponsored by the IAEA. CZTU code is being modified to analyze M400 spectra. Data collection, code development and analysis will be continued in FY22 as per the FY22 Project Work Plan (PWP).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recommended Representative Isotopic Compositions for Potential VTR Pu Supplies

This document recommends isotopic compositions to represent selected Pu supplies that might be made available for use in VTR driver fuel. These compositions are intended to be conservative representations suitable for determination of environmental impacts associated with use of the selected Pu supplies, but not upper bounds of all possible compositions. The selected Pu supplies under consideration are themselves representations of a more complicated set of possibilities, defined in a manner to allow efficient but conservative analysis of impacts. The source definitions to be considered are as follows: 1) Foreign sources of reactor-grade plutonium. This material would be provided as polished material in an oxide form and is assumed to be transported from Europe (France or England); 2) Domestic, non-weapon sources of plutonium such as unused FFTF fuel, Hanford metal (stored at SRS), and various oxides; 3) Domestic sources of weapons-grade plutonium, including metal from dismantled pits and otherwise excess to stockpile needs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NWAL Validation Report for U Assay by Potentiometric Titration (Modified Davies and Gray Technique) and U and PU Assay by Isotope Dilution Mass Spectrometry

SRNL Sensing & Metrology, previously Analytical Laboratory, is a member of the IAEA Network of Analytical Laboratories for Nuclear Material Measurement that is qualified to provide Uranium and Plutonium isotopic analysis of nuclear materials by Thermal Ionization Mass Spectrometry. As part of the membership, SRNL participated in the 2019 Nuclear Material Round Robin to maintain the qualification to provide isotopic analysis. SRNL also participated with the additional intent to qualify Uranium Assay by Potentiometric Titration (Davies and Gray method) and Uranium and Plutonium Isotope Dilution by Thermal Ionization Mass Spectrometry as part of the International Atomic Energy Agency’s Network of Analytical Laboratories. The proficiency test exercise was conducted by the Office of Safeguards Analytical Services, Department of Safeguards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simultaneous Isotopic Analysis of U, Pu, and Am in Spent Nuclear Fuel by Resonance Ionization Mass Spectrometry

Solid samples of spent nuclear fuel were analyzed for actinide isotopic composition by resonance ionization mass spectrometry. Isotopes of U, Pu, and Am were simultaneously quantified using a new method that removes and/or resolves the isobaric interferences at 238 U/ 238 Pu and 241 Pu/ 241 Am without sample preparation other than cutting and mounting small (~10 μm) samples. Trends in burnup and neutron capture product distributions were correlated with the sampling positions inside the reactor. Overall, the results show the skin effect, in which the core and near-edge regions of a fuel pellet exhibit strong differences in actinide concentrations and isotope distributions due to differences in the neutron energy spectra between the pellet rim and the core. While no elemental concentration measurements were made, the ability to measure the 238 Pu/ 239 Pu ratio in the presence of a 7400× excess of 238 U enabled an estimate of the enhancement in Pu concentration due to the skin effect at the rim of the pellet.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

LLNL International Working Group on Gamma Spectrometry - Preparation of IDB Dataset

The spectral information and associated metadata, including source information, detector setup, and shielding configuration is described in human readable, comma-separated text files (csv). Five csv files are associated with each material type and include the following information (where [Isotope] is U, Pu, and MOX): [Isotope]_measurement_metadata - Metadata of the measurement configuration, including material composition at time of acquisition (decay corrected from certificate date). Data that is unique to a measurement configuration e.g. detector geometry, source-detector distance, analyzer and other electronics used, attenuating materials are provided in this file. [Isotope]_spectrum_metadata - The information that is unique to the spectrum. This includes detector specifications (e.g. date of acquisition, number of channels, gain (keV/channel), energy range, real and live time, full width half-maximum (FWHM) of the 186 or 208 peak for uranium or plutonium measurements, respectively. [Isotope]_source_metadata - The source material used for the measurement, this includes the ratio and uncertainties of isotopes present and processing information of the material. In addition, the certificate information for the source material is listed. [Isotope]_spectrum_counts_metadata - The counts per channel for each spectrum. This data is linked via the UID.spectrum index to the measurement_metadata file. [Isotope]_spectrum_checksum_metadata The MD5 checksum for the original spectrum file. This data is linked via the UID.spectrum index to the measurement_metadata file. This information is provided to prevent duplication of entries in the database.

42 ENGINEERING↗