Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Proportional counters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

X-ray spectral and flux variability of the microquasar GRS 1758-258 on timescales from weeks to years

We present the spectral and timing evolution of the persistent black hole X-ray binary GRS 1758-258 based on almost 12 years of observations using the Rossi X-ray Timing Explorer Proportional Counter Array. While the source was predominantly found in the hard state during this time, it entered the thermally dominated soft state seven times. In the soft state GRS 1758-258 shows a strong decline in flux above 3 keV rather than the pivoting flux around 10 keV more commonly shown by black hole transients. In its 3–20 keV hardness intensity diagram, GRS 1758-258 shows a hysteresis of hard and soft state fluxes typical for transient sources in outburst. The RXTE-PCA and RXTE-ASM long-term light curves do not show any orbital modulations in the range of 2–30 d. However, in the dynamic power spectra significant peaks drift between 18.47 and 18.04 d for the PCA data, while less significant signatures between 19 d and 20 d are seen for the ASM data as well as for the Swift/BAT data. We discuss different models for the hysteresis behavior during state transitions as well as possibilities for the origin of the long term variation in the context of a warped accretion disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Alternatives to NIST Cf-252 Iirradiations for Transfer Calibration of S-32 Neutron Monitors

Gas-flow proportional counting systems are used by the Radiation Metrology Laboratory (RML) at Sandia National Laboratories for reactor fluence monitoring with the 32 S(n,p) 32 P reaction. Calibration of these systems has traditionally been accomplished by fluence-transfer irradiations at the NIST 252 Cf facility. Such calibrations have become increasingly difficult as the NIST 252 Cf source decayed to unusable levels. To minimize the risk to the testing programs from an inability to properly calibrate these systems, the RML has developed two alternative calibration techniques: 1) development and implementation of certified 32 P sources for activity calibrations and subsequent calculation of neutron fluence, and 2) direct counting of non-certified reactor-irradiated sulfur pellets by liquid scintillation counting to determine 32 P activity for the subsequent calibration of gas-flow proportional counters. Preliminary comparisons show that the several calibration methods are capable of overall uncertainties within about 5 percent.

Vehar, David W.↗

Solid, structured composite neutron detectors with high dynamic range capability

Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NEWS-G detector at SNOLAB

The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve sub-GeV/c 2 Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionisation with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in Canada in 2021. This article details the different processes involved in the fabrication of the NEWS-G experiment. Also outlined in this paper are the mitigation strategies, measurements of radioactivity of the different components, and estimations of induced background event rates that were used to quantify and address detector backgrounds.

47 OTHER INSTRUMENTATION↗

Quenching factor measurements of neon nuclei in neon gas

The NEWS-G collaboration uses spherical proportional counters (SPCs) to search for weakly interacting massive particles (WIMPs). Here, in this paper, we report the first measurements of the nuclear quenching factor in neon gas at 2 bar using an SPC deployed in a neutron beam at the TUNL facility. The energy-dependence of the nuclear quenching factor is modeled using a simple power law: $αE^{β}_{nr}$; we determine its parameters by simultaneously fitting the data collected with the detector over a range of energies. We measured the following parameters in Ne : CH 4 at 2 bar: α= 0.2801±0.0050 (fit) ±0.0045 (sys) and β=0.0867±0.020 (fit) ±0.006 (sys). Our measurements do not agree with expected values from SRIM or Lindhard theory. We demonstrated the feasibility of performing quenching factor measurements at sub-keV energies in gases using SPCs and a neutron beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Review of Direct Neutron Conversion and Detection Processes

Commercial and laboratory neutron detection systems use indirect neutron response of materials like pressurized helium-3 (via nuclear reaction 3He(n, p)3H) to measure and count neutrons emanating from a source. Recently a host of semiconductors, especially a ternary semiconductor of lithium indium diselenide (6LiInSe2) and a quaternary alloy of enriched lithium-6, indium, phosphorous, and selenium (6LiInP2Se6), have shown promising neutron counting possibilities by directly converting neutrons into charge-carrying elements within the body of the semiconductor. These semiconductors have high thermal neutron capture cross sections, suitable energy bandgaps (~2.0 electron volts) for room-temperature operations, and a favorable electronic band structure for efficient electron charge transport. The article examines the semiconductor properties of these compounds in terms of their neutron counting capabilities and possible ways to extract neutron energy information from them. Lithium-6 and boron-10 (with thermal neutron absorption cross sections of 938 ± 6 and 3855 ± 26 barns, respectively) produce charged particles to be measured via indirect neutron interactions. The efficiency of indirect conversion neutron detectors is limited because of the inefficiencies in conversion mechanism. In case of direct conversion, the neutrons create charged particles in a single material for neutron capture and charge collection, increasing detection efficiency. Unlike 3He proportional counters, which provide no neutron energy information, the semiconductors can be used as neutron energy spectrometer. Fully resolved neutron energy by 6LiInP2Se6 from a plutonium-beryllium source has been reported in the literature. We will discuss the influence of these multilayered semiconductors’ crystallographic structures and growth techniques on neutron energy determination.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

Abstract The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $$^3$$ 3 He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the Ricochet experiment should reach a statistical significance of 4.6 to 13.6 $$\sigma $$ σ for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of γ-ray branching ratios for ⁹⁵Zr and ¹⁴⁷Nd

For many fission products, the γ rays emitted following decay provide an easily-detectable signature that can be used to identify their quantities and distributions in a sample. As a result, γ-ray spectroscopy is often exploited to study fission-product yields (FPYs), provided sufficiently accurate information on the γ-ray branching ratio is available. However, in many cases, the uncertainties in the existing nuclear data are large enough that they compromise the precision achievable for modern experiments and applications. To address this need, we have developed a new experimental method that is well suited to precisely measure the γ-ray branching ratios in the decay of long-lived fission products. The approach involves the production of a radiopure sample by implantation of a mass-separated ion beam from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) facility on a thin carbon foil. The emitted β -decay radiation is detected with a 4π gas proportional counter and a meticulously efficiency-calibrated high-purity germanium (HPGe) detector. As a first measurement to demonstrate the approach, we studied the γ-ray branching ratios of the strongest transitions following the decay of ⁹⁵Zr and decay-daughter ⁹⁵Nb and determined these branching ratios to fractional precisions of 1%. We then applied this approach to determine the γ-ray branching ratios for the β decay of ¹⁴⁷Nd. The results for the γ-ray branching ratios are presented here and compared to previous results and evaluations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Spectrum and 10B(n,α) Measurements in ZPPR-15

Neutron spectra were measured at the core center with proton recoil spectrometers in ZPPR15A loading 66, ZPPR-15B loading 90 and ZPPR loading 186. In addition, neutron spectra were measured in the SSNA shield configuration in ZPPR-15B loading 121 and in the BCNA shield configuration in ZPPR-15B loading 126. The ZPPR-15 neutron spectrum measurement and data processing techniques were described and analyzed. Total uncertainties were derived for all five spectrum measurements. A back-to-back proportional counter was used to measure the 10 B(n,α) reaction rate at six locations in the simulated shield, radial reflector and outer core in the ZPPR-15B BCNA shield experiment. The measurements were described and analyzed. A total uncertainty was derived for the 10 B(n,α) reaction rate measurements. The ZPPR-15 experimental records were used to develop detailed as-built Monte Carlo models for the five neutron spectrum measurement configurations and for the six 10 B(n,α) measurement configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Subcriticality Measurements for a Changing Concentration Uranyl Nitrate Solution Tank by Californium Source-Driven Noise Analysis

Subcritical californium source-driven noise analysis (CSDNA) measurements were performed at the Oak Ridge Critical Experiments Facility in 1983 using a stainless-steel tank with an inside diameter of 76.2 cm and a height of 91.4 cm but only filled with a uranyl (93.16 wt.% 235 U) nitrate solution to a height of 76.2 cm for all measurements. The free acid content of the uranyl nitrate solution was less than 0.01 N to minimize hazards in handling. The total available highly enriched uranium for these measurements was 5,296 g. The concentration of the solution was varied from the highest density of 14.71 grams of uranium per liter (g U/L) initially in 16 steps, lowering the concentration to 0.3492 g U/L, and finally using a tank filled with only water. The tank had a Plexiglas lid to minimize evaporation. The Cf source was contained in a re-entrant Lexan tube which could be in the solution parallel to the axis of the cylindrical tank. The detectors were 3 He proportional counters in the solution in shrink-fit tubing to isolate the counters from the fissile solution and adjacent to the outside of the tank. In some cases, the detectors were scintillators adjacent to the outside of the tank. In other cases, the source was external to the tank. Some data presented in this report are from notes and are not in the logbook. The prompt neutron decay constant was obtained from fitting the date from the CSDNA measurements. The purpose of this report is to document the experimental information for the measurements performed so that later, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a Nuclear Energy Agency benchmark. The prompt neutron decay measurements could be the basis of as International Reactor Physic Benchmark Program. The data from these measurements are available from the Records Management Services Department of Oak Ridge National Laboratory, and the logbook is also available from the ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

UNESE Argon-39 Measurement Techniques: Developing an above-ground Argon-39 Measurement Capability

The Underground Nuclear Explosion Signatures Experiment (UNESE) sought to use 37 Ar as a tracer for measuring noble-gas migration in the soil surrounding historic Underground Nuclear Explosions (UNE). One unexpected observation was the presence of the much longer-lived isotope 39 Ar from historic UNEs. Quantifying the activity of 39 Ar proved difficult due to the lack of capability to measure significantly-above-background levels of 39 Ar and a general discomfort to repeatedly expose Ultra-Low-Background Proportional Counters (ULBPCs) to significant radioactivity. Because the whole-air samples collected for the 37 Ar tracer measurement were already being measured on the above-ground argon capability, it was decided to expand that capability to include 39 Ar. This document describes the efforts required to achieve quantitative reporting of the 39 Ar backgrounds measured during experiments at the sites of the historic Barnwell and Disko Elm UNEs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Operation of the Fast Neutron Coincidence Collar (FNCL) with a DD-Neutron Generator

For more than 30 years, the quantitative assay of the 235 U content of light water reactor fresh fuel assemblies relied on measuring coincidence neutrons from fissions induced by an Am(Li) neutron source using 3 He based detectors. The Fast Neutron Collar (FNCL) developed by the International Atomic Energy Agency (IAEA), replaces traditional 3 He proportional counters with an array of liquid scintillator detectors arranged about the fuel assembly to provide improved measurement precision and reduced sensitivity to gadolinium poison rods. The FNCL relies on Am(Li) neutron sources that are no longer commercially available. This work examines the replacement of Am(Li) sources with a commercial off the-shelf deuterium–deuterium (DD) neutron generator. In addition to mitigating supply concerns, the neutron generator offers advantages in measurement precision and potential automation of sequential passive/active neutron measurements. This report presents the initial performance results for both the integrated DD/FNCL and Am(Li)/FNCL assays of compact depleted uranium, low-enriched uranium, and highly enriched uranium standards along with an estimate of the expected performance for fresh fuel assemblies. A discussion of the design and operation of the “FNCL Analysis and Simulation Software” is also provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PNNL OS3700 Tritium Monitoring System Software and Hardware Operations Manual (Rev.2)

The Pacific Northwest National Laboratory (PNNL) OS3700 Tritium Monitoring System Software and Hardware Operations Manual describes how to install and operate the software and hardware on a personal computer operating in conjunction with the Berthold Technologies LB110 flow-through proportional counter detector system. Included are operational details for the software functions, how to read and use the dropdown menus, how to understand readings and calculations, and how to access the database tables.

54 ENVIRONMENTAL SCIENCES↗

10 Boron-film-based gas detectors at ESS

The development of detectors for the European Spallation Source is an important parallel element to the effort put into the design and construction of the neutron source and instruments. The 10Boron-film-based detector developments that started over a decade ago as basic detector concepts have now reached technical maturity after intense prototyping work and numerous testing campaigns. Several of the ESS beamlines that will soon enter the commissioning phase started welcoming the detector systems built with the 10 B-film converter technology. The real-size demonstrators evolved in the last 2–3 years into a diverse suite of gas proportional counters for use in diffraction, reflectometry and small-angle scattering studies in spite of the operational complexity posed by the requirements for large-area coverage, low material budget and robustness for operation in the high-flux and high-radiation environment of ESS. The detectors are now being shipped to ESS or undergoing the last performance and calibration tests before being handed over to the instrument teams for installation in the host beamlines. A common feature of these detector systems is the very large number of readout channels that they are instrumented with in order to fulfill the demanding requirements for sensitivity, spatial resolution and count-rate capability. Across all of the detector types that will operate at ESS, the integration, testing and commissioning of the read-out technologies and software tools for data reduction, calibration and analysis are the focus of the detector and integration teams. These will yield a wealth of knowledge about their operation as well as initial results on the in-situ performance, a very important asset to ensure rapid commissioning of the detectors when neutrons from the ESS source become available. In this paper we will give an overview of the 10 B-film-based detector technologies included in the ESS detector suite that are currently facing the transition from the production phase to installation and integration with the other beamline components, which comes with its own specific challenges of both organizational and technical nature.

47 OTHER INSTRUMENTATION↗

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rossi-alpha measurements of fast plutonium metal assemblies using organic scintillators

The reactivity and the k-effective multiplication factor (k eff ) of a fissionable assembly are quantities of widespread interest. These values can be inferred from Rossi-alpha measurements of the prompt neutron decay constant (or the inverse:α -1 ). It has been shown that 3 He-gas proportional counter-based detection systems are insensitive to α -1 of fast assemblies (much faster than tens of microseconds). Therefore, it is of interest to investigate fast detection systems such as those based on organic scintillation detectors. In this work, an array of 12 cylindrical, 5.08 cm x 5.08 cm diameter trans-stilbene organic scintillators was used to measure five subcritical assemblies. One assembly was a sphere of approximately 4.5 kg of alpha-phase, weapons-grade plutonium (k eff = 0.773, α -1 = 11.84 ns) known as the BeRP ball encased in a thin stainless-steel clad. The other assemblies used the same encased sphere and 7.62 cm of iron, nickel, copper, or tungsten reflectors (k eff = 0.884, 0.916, 0.924, 0.939, respectively and α -1 = 36.60, 41.56, 49.60, 70.32 ns, respectively). Finally, this work (1) validates Rossi-alpha measurements with organic scintillators by demonstrating good agreement between measurements and simulations; and (2), demonstrates that organic scintillator-based systems are sensitive to α -1 on the order of 10–100 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The S π RIT time projection chamber

The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (SπRIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The SπRIT TPC has a 50.5 cm drift length and an 86.4 cm × 134.4 cm 2 pad plane with 12,096 pads that are equipped with the Generic Electronics for TPCs. The SπRIT TPC allows excellent reconstruction of particles and provides isotopic resolution for pions and other light charged particles across a wide range of energy losses and momenta. Here, details of the SπRIT TPC are presented, along with discussion of the TPC performance based on cosmic ray and charged particles emitted in heavy ion collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic ray radiography of a human phantom

Cosmic ray muons that reach the earth's surface provide a natural source of radiation that is used for radiography. In this paper, we show that radiography using the cosmic radiation background provides a method that can be used to monitor bulk aspects of human anatomy. We describe a method that can be used to measure changes in patients as a function of time by cosmic ray muon radiography. Modeling shows muon tomography could provide hourly readouts of parameters such as lung density with sufficient sensitivity to detect the time changes in the inflammation of the lungs in, e.g., COVID patients.

60 APPLIED LIFE SCIENCES↗