At least 37 records · Page 2

Experiments regarding methylphosphonic acid in proficiency test Sample 445

Samples 445/07 and 444/07 (blank) were extracted, in triplicate, by three different extraction methods – column elution, gentle rocking, and agitation with a vortex mixer. The recoveries for MPA differed depending on the extraction method used. In Sample 445/07, MPA was measured at ~2 μg/g (~20% recovery) when extracted by column elution and at ~1 μg/g when gentle rocking or vortex mixing was used. In addition, the soil matrix was observed to cause some ionization suppression effects when LC/MS analysis was used. The results of our experiments support the findings of the Sample Preparation Laboratory and suggest that MPA should remain a scoring chemical for the 44th OPCW PT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proficiency Testing for Evaluating Aerospace Materials Test Anomalies

ASTM G 86 and ASTM G 74 are commonly used to evaluate materials susceptibility to ignition in liquid and gaseous oxygen systems. However, the methods have been known for their lack of repeatability. The inherent problems identified with the test logic would either not allow precise identification or the magnitude of problems related to running the tests, such as lack of consistency of systems performance, lack of adherence to procedures, etc. Excessive variability leads to increasing instances of accepting the null hypothesis erroneously, and so to the false logical deduction that problems are nonexistent when they really do exist. This paper attempts to develop and recommend an approach that could lead to increased accuracy in problem diagnostics by using the 50% reactivity point, which has been shown to be more repeatable. The initial tests conducted indicate that PTFE and Viton A (for pneumatic impact) and Buna S (for mechanical impact) would be good choices for additional testing and consideration for inter-laboratory evaluations. The approach presented could also be used to evaluate variable effects with increased confidence and tolerance optimization.

Hirsch, D.↗

Integrated Data Collection Analysis (IDCA) Program - Mixing Procedures and Materials Compatibility

Three mixing procedures have been standardized for the IDCA proficiency test—solid-solid, solid-liquid, and liquid-liquid. Due to the variety of precursors used in formulating the materials for the test, these three mixing methods have been designed to address all combinations of materials. Hand mixing is recommended for quantities less than 10 grams and Jar Mill mixing is recommended for quantities over 10 grams. Consideration must also be given to the type of container used for the mixing due to the wide range of chemical reactivity of the precursors and mixtures. Eight web site sources from container and chemical manufacturers have been consulted. Compatible materials have been compiled as a resource for selecting containers made of materials stable to the mixtures. In addition, container materials used in practice by the participating laboratories are discussed. Consulting chemical compatibility tables is highly recommended for each operation by each individual engaged in testing the materials in this proficiency test.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The International Framework for Maintaining Equivalence and Traceability in Radionuclide Metrology

Confidence that a testing or calibration laboratory consistently obtains reliable results is of major importance to users of laboratory services and participation in proficiency testing schemes provides laboratories with an objective means of assessing and demonstrating the level of confidence that can be ascribed to the reliability of the data they are producing. That level of confidence, in turn, depends on the quality of the proficiency tests and, in particular, on the accuracy of the property values associated with the test samples. In the ideal situation, the relevant property value, such as the activity of a particular radionuclide in a test matrix, will be directly traceable to the SI via comparisons with a national or international metrology institute (NMI). This, in turn, begs the question of, how reliable are the results from that NMI.Demonstration of that reliability at the highest metrological levels is achieved through inter-laboratory comparisons that are conducted between national and international metrological institutes. These are coordinated primarily by the Bureau International des Poids et Mesures (BIPM) via Key Comparisons or by comparisons within Regional Metrological Organisations (RMOs), with the results from those RMO exercises being linked to the BIPM Key Comparison results. Such programmes have been in place for many years but they have grown in importance and frequency over the past decade. Tabulation of these comparison data has been regularized recently and made available to the user communities via the BIPM Key Comparison Database (KCDB).In the field of ionizing radiation, the radionuclide metrology discipline exhibits a number of special features. For example, these include the number of potential radionuclides in a user sample; the variety of physical and chemical formats that may be presented; the statistical and temporal effects of radioactive decay; the variations in primary standardization techniques; and the restricted applicability of those primary standardization techniques to the full range of potential radionuclides and activities. Each of these, singly or in combination, ensure that there can never be a fully comprehensive set of Key Comparisons which will cover the requirements of the user community and, in turn, compromise the ability to provide a full range of proficiency tests for testing and calibration laboratories.These problems are discussed, in the context of radioactivity measurements, together with the structure and range of Key Comparisons and associated databases at the highest international level that are currently in place to underpin the proficiency tests that are necessary for the user communities in this field of application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical analysis of an inter-laboratory comparison of small-scale safety and thermal testing of RDX

In this study, the Integrated Data Collection Analysis (IDCA) program has conducted a proficiency test for small-scale safety and thermal (SSST) testing of homemade explosives (HMEs). Described here are statistical analyses of the results from this test for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Class 5 Type II standard. The material was tested as a well-characterized standard several times during the proficiency test to assess differences among participants and the range of results that may arise for well-behaved explosive materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program: FY2011 Project Descriptions

This document provides brief descriptions of research topics for consideration by the IDCA for potential funding in funding in FY 2011. The topics include the utilization of the results from the Proficiency Test developed during FY 2010 to start populating the small-scale safety and thermal testing (SSST) Testing Compendium and revising results from methods modifications. Other research topics were also developed for FY 2011 from issues that arose in the Proficiency Test.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program — IDCA Quarterly Program Review, September 14 and 15, 2010

The IDCA conducted a program review at Los Alamos National Laboratory, September 14 and 15, 2010. The review was divided into three parts: 1) an update on the current status of the program, 2) an information exchange and discussion on technical details for current issues and future planning, and 3) a tour of the SSST testing facilities at LANL. The meeting started with an update from DHS by Laura Parker and a restating of some of the objectives of the Proficiency Test of which the IDCA is currently engaged. This update was followed by a discussion of some high level programmatic issues particularly about ways of communicating the overall goals of the IDCA to non-technical representatives. The final topic focused on the difficulty of releasing information, including the DHS approval process, ITAR, and open publication. Next JGR presented a technical summary of accomplishments, schedule, milestones, and future directions. These key points made were: 1) about 1/3 of the materials have been tested, 2) some participants are behind others causing a lag in report writing, 3) method reports have been assigned to various participants to speed up the process of reporting, 4) the SSST Compendium needs reformatting and restructuring, and 5) the Compendium needs a web site to house with access control. After the technical update, some of the Proficiency Test results were shown comparing data from the various laboratories. These results included comparisons of the RDX standard, KC/sugar mixtures (-100 mesh and as received), KC/dodecane, KP/Al, and KP/C. Impact, friction, ESD, and DSC results were the focus. All the participants were involved in these discussions. This report includes summary notes, presentations, and explanatory information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The National Dissemination of International Measurements

The paper presents the most significant actions which a primary Radionuclide Metrology Laboratory must accomplish, in order to disseminate the international equivalence to the entire national traceability chain: absolute standardization methods and demonstration of international equivalence, construction and calibration of a consistent set of secondary standardization equipment, preparation of radioactive standards. Delivery of radioactive standards to the end users and carrying out metrological services. Organization of national proficiency tests with the users. International validation of secondary standards by proficiency tests and establishment of a Quality System Assurance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

OPCW Twining Project Visit by the National Laboratory of Scientific and Technical Police (LNPST) to Lawrence Livermore National Laboratory Forensic Science Center (LLNL)

PURPOSE FOR TRIP Through the Organisation for Prohibition of Chemical Weapons (OPCW) Twinning and Assistance Program, Lawrence Livermore National Laboratory, Forensic Science Center (LLNL) has been paired with Morocco’s National Laboratory of Scientific and Technical Police (LNPST), with the goal of mentoring LNPST to become an OPCW Designated Laboratory. The purpose of this visit was for LLNL staff to mentor staff from LNPST as they participated in hands-on, laboratory-based exercises to analyze proficiency test samples prepared by LLNL. This visit was designed to help LNPST scientists strengthen their skills in OPCW proficiency testing.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Implementation of IAEA /1/INT/054 Project in Nuclear Analytical Techniques Group of Argentina: Current State

This paper presents the implementation of the training received through the IAEA Project 'Preparation of Reference Materials and Organization of Proficiency Tests Rounds' in the Nuclear Analytical (NAT) Group of CNEA. Special emphasis is done on those activities related to the first Proficiency Test being carried out by the NAT Group.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Code Comparison Study Fosters Confidence in the Numerical Simulation of Enhanced Geothermal Systems

Numerical simulation has become a standard analytical tool for scientists and engineers to evaluate the potential and performance of enhanced geothermal systems. A variety of numerical simulators developed by industry, universities, and national laboratories are currently available and being applied to better understand enhanced geothermal systems at the field scale. To yield credible predictions and be of value to site operators, numerical simulators must be able to accurately represent the complex coupled processes induced by producing geothermal systems, such as fracture aperture changes due to thermal stimulation, fracture shear displacement with fluid injection, rate of thermal depletion of reservoir rocks, and permeability alteration with mineral precipitation or dissolution. A suite of numerical simulators was exercised on a series of test problems that considered coupled thermal, hydraulic, geomechanical, and geochemical (THMC) processes. Problems were selected and designed to isolate selected coupled processes, to be executed on workstation class computers, and have simple but illustrative metrics for result comparisons. This paper summarizes the initial suite of seven benchmark problems, describes the code comparison activities, provides example results for problems and documents the capabilities of currently available numerical simulation codes to represent coupled processes that occur during the production of geothermal resources. Code comparisons described in this paper use the ISO (International Organization for Standardization) standard ISO-13538 for proficiency testing of numerical simulators. This approach was adopted for a recent code comparison study within the radiation transfer-modeling field of atmospheric sciences, which was focused on canopy reflectance models. This standard specifies statistical methods for analyzing laboratory data from proficiency testing schemes to demonstrate that the measurement results do not exhibit evidence of an unacceptable level of bias.

benchmark problems↗

Effective methylation of phosphonic acids related to chemical warfare agents mediated by trimethyloxonium tetrafluoroborate for their qualitative detection and identification by gas chromatography-mass spectrometry

The effective methylation of phosphonic acids related to chemical warfare agents (CWAs) employing trimethyloxonium tetrafluoroborate (TMO·BF 4 ) for their qualitative detection and identification by gas chromatography-mass spectrometry (GC-MS) is presented. The methylation occurs in rapid fashion (1 h) and can be conveniently carried out at ambient temperature, thus providing a safer alternative to the universally employed diazomethane-based methylation protocols. Optimization of the methylation parameters led us to conclude that methylene chloride was the ideal solvent to carry out the derivatization, and that even though methylated products can be observed surfacing after only 1 h, additional time was not found to be detrimental but beneficial to the process particularly when dealing with analytes at low concentrations (~10 μg mL -1 ). Due to its insolubility in methylene chloride, TMO·BF 4 conveniently settles to the bottom during the reaction and does not produce additional interfering by-products that may further complicate the GC-MS analysis. We demonstrated the method to successfully methylate a variety of Schedule 2 phosphonic acids, including their half esters, resulting in derivatives that were readily detected and identified using the instrument's spectral library. Most importantly, the method was shown to simultaneously methylate a mixture of the organophosphorus-based nerve agent hydrolysis products: pinacolyl methylphosphonate (PMPA), cyclohexyl methylphosphonate (CyMPA) and ethyl methylphosphonate (EMPA) (at a 10 μg mL - 1 concentration each) in a fatty acid ester-rich organic matrix (OPCW-PT-O 3 ) featured in the 38th Organisation for the Prohibition of Chemical Weapons (OPCW) Proficiency Test. Additionally, the protocol was found to effectively methylate N,N-diethylamino ethanesulfonic acid and N,N-diisopropylamino ethanesulfonic acid that are products arising from the oxidative degradation of the V-series agents VR and VX respectively. This work described herein represents the first report on the use of TMO·BF 4 as a viable, stable and safe agent for the methylation of phosphonic acids and their half esters and within the context of an OPCW Proficiency Test sample analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program - Statistical Analysis of RDX Standard Data Sets

The Integrated Data Collection Analysis (IDCA) program is conducting a Proficiency Test for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are statistical analyses of the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard. The material was tested as a well-characterized standard several times during the proficiency study to assess differences among participants and the range of results that may arise for well-behaved explosive materials. The analyses show that there are detectable differences among the results from IDCA participants. While these differences are statistically significant, most of them can be disregarded for comparison purposes to assess potential variability when laboratories attempt to measure identical samples using methods assumed to be nominally the same. The results presented in this report include the average sensitivity results for the IDCA participants and the ranges of values obtained. The ranges represent variation about the mean values of the tests of between 26% and 42%. The magnitude of this variation is attributed to differences in operator, method, and environment as well as the use of different instruments that are also of varying age. The results appear to be a good representation of the broader safety testing community based on the range of methods, instruments, and environments included in the IDCA Proficiency Test.

round-robin test↗

AM Powder Flowability Capabilities at NASA Marshall Space Flight Center (MSFC)

Additive Manufacturing (AM) powder flowability is critical to metal 3D printing, because the more fluid the powder is, the better powder spreads. The NASA MSFC’s Contamination Control Team (CCT) studies density, flow, particle size distribution, and morphology for programs such as Moon-to-Mars Planetary Autonomous Construction Technology (MMPACT), ASTM Proficiency Testing for AM and Powder Metallurgy, and MSFC’s AM team. Examining and measuring powder characteristics is essential for improving flowability of AM powder and ensuring lot-to-lot consistency, which will help to prevent defects in manufactured parts. The CCT uses several methods to characterize AM powder. Optical particle size distribution and morphology analyses determine particle parameters including size, circularity, convexity, and dimensions. The Carney and Hall Flowmeter Funnel measures time it takes powder to flow through a funnel to compare relative flowability (free-flowing and non-free-flowing). In addition to this, the device utilizes a density cup which determines apparent density. Lastly, the Revolution Powder Analyzer measures dynamic powder flowability and behavior over time via digital imaging. Using the CCT’s lab, the team has produced ASTM Powder Proficiency Testing results with flow rates, apparent density, particle size distribution, and tap density on titanium-based and nickel-based powder and compared data with other companies/labs. Morphology data was also collected for various regolith simulant powder for the MMPACT program. Lastly, the CCT used morphology data to examine the flowability of Inconel 718 powder for Selective Laser Melting (SLM) and Directed Energy Deposition (DED) printers at MSFC. The CCT’s essential work in studying and enabling AM powder characterization has helped and will continue to help study new and refined powders in the AM industry.

Additive Manufacturing↗

AM Powder Flowability Capabilities at NASA Marshall Space Flight Center (MSFC)

Additive Manufacturing (AM) powder flowability is critical to metal 3D printing, because the more fluid the powder is, the better powder spreads. AM Powder Flowability Capabilities at NASA MSFC studies density, flow, particle size distribution, and morphology for programs such as Moon-to-Mars Planetary Autonomous Construction Technology (MMPACT), ASTM Proficiency Testing for AM and Powder Metallurgy, and MSFC’s AM team. Examining and measuring powder characteristics is essential for improving flowability of AM powder and ensuring lot-to-lot consistency, which will help to prevent defects in manufactured parts. The Contamination Control Team (CCT) uses several methods to characterize AM powder. Optical particle size distribution and morphology analyses determine particle parameters including size, circularity, convexity, and dimensions. The Carney and Hall Flowmeter Funnel measures time it takes powder to flow through a funnel to compare relative flowability (free-flowing and non-free-flowing). In addition to this, the device utilizes a density cup which determines apparent density. Lastly, the Revolution Powder Analyzer measures dynamic powder flowability and behavior over time via digital imaging. Using the CCT’s lab, the team has produced ASTM Powder Proficiency Testing results with flow rates, apparent density, particle size distribution, and tap density on titanium-based and nickel-based powder and compared data with other companies/labs. Morphology data was also collected for various regolith simulant powder for the MMPACT program. Lastly, the CCT used morphology data to examine the flowability of Inconel 718 powder for Selective Laser Melting (SLM) and Directed Energy Deposition (DED) printers at MSFC. The CCT’s essential work in studying and enabling AM powder characterization has helped and will continue to help study new and refined powders in the AM industry.

Additive Manufacturing↗

Integrated Data Collection Analysis (IDCA) Program - Final Review September 12, 2012 at DHS

The Integrated Data Collection Analysis (IDCA) program conducted a final program review at the Department of Homeland Security on September 12, 2012. The review was focused on the results of the program over the complete performance period. A summary presentation delineating the accomplished tasks started the meeting, followed by technical presentations on various issues that arose during the performance period. The presentations were completed with a statistical evaluation of the testing results from all the participants in the IDCA Proficiency Test study. The meeting closed with a discussion of potential sources of funding for continuing work to resolve some of these technical issues. This effort, funded by the Department of Homeland Security (DHS), put the issues of safe handling of these materials in perspective with standard military explosives. The study added Small-Scale Safety and Thermal (SSST) testing results for a broad suite of different HMEs to the literature, and suggested new guidelines and methods to develop safe handling practices for HMEs. Each participating testing laboratory used identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results were compared among the laboratories and then compared to historical data from various sources. The testing performers involved were Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Naval Surface Warfare Center, Indian Head Division (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory, Tyndall AFB (AFRL/RXQL). These tests were conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytical method for nitroaromatic explosives in radiologically contaminated soil for ISO/IEC 17025 accreditation

Here, unique hazards are presented in the analysis of radiologically contaminated samples. Strenuous safety and security precautions must be in place to protect the analyst, laboratory, and instrumentation used to perform analyses. A validated method has been optimized for the analysis of select nitroaromatic explosives and degradative products using gas chromatography/mass spectrometry via sonication extraction of radiologically contaminated soils, for samples requiring ISO/IEC 17025 laboratory conformance. Target analytes included 2-nitrotoluene, 4-nitrotoluene, 2,6-dinitrotoluene, and 2,4,6-trinitrotoluene, as well as the degradative product 4-amino-2,6-dinitrotoluene. Analytes were extracted from soil in methylene chloride by sonication. Administrative and engineering controls, as well as instrument automation and quality control measures, were utilized to minimize potential human exposure to radiation at all times and at all stages of analysis, from receiving through disposition. Though thermal instability increased uncertainties of these selected compounds, a mean lower quantitative limit of 2.37 µg/mL and mean accuracy of 2.3% relative error and 3.1% relative standard deviation were achieved. Quadratic regression was found to be optimal for calibration of all analytes, with compounds of lower hydrophobicity displaying greater parabolic curve. Blind proficiency testing (PT) of spiked soil samples demonstrated a mean relative error of 9.8%. Matrix spiked analyses of PT samples demonstrated that 99% recovery of target analytes was achieved. To the knowledge of the authors, this represents the first safe, accurate, and reproducible quantitative method for nitroaromatic explosives in soil for specific use on radiologically contaminated samples within the constraints of a nuclear analytical lab.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗