Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Productive Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Detection of Foreign Materials on Broiler Breast Meat Using a Fusion of Visible Near-Infrared and Short-Wave Infrared Hyperspectral Imaging

Foreign material (FM) found on a poultry product lowers the quality and safety of the product. We developed a fusion method combining two hyperspectral imaging (HSI) modalities in the visible-near infrared (VNIR) range of 400–1000 nm and the short-wave infrared (SWIR) range of 1000–2500 nm for the detection of FMs on the surface of fresh raw broiler breast fillets. Thirty different types of FMs that could be commonly found in poultry processing plants were used as samples and prepared in two different sizes (5 × 5 mm 2 and 2 × 2 mm 2 ). The accuracies of the developed Fusion model for detecting 2 × 2 mm 2 pieces of polymer, wood, and metal were 95%, 95%, and 81%, respectively, while the detection accuracies of the Fusion model for detecting 5 × 5 mm 2 pieces of polymer, wood, and metal were all 100%. The performance of the Fusion model was higher than the VNIR- and SWIR-based detection models by 18% and 5%, respectively, when F1 scores were compared, and by 38% and 5%, when average detection rates were compared. The study results suggested that the fusion of two HSI modalities could detect FMs more effectively than a single HSI modality.

36 MATERIALS SCIENCE↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Californium-252 production at the High Flux Isotope Reactor - I: Validation study using campaign data

This paper presents a series of 252 Cf production validation and code-to-code comparison studies performed based on data from the production campaigns at the High Flux Isotope Reactor (HFIR). These studies support efforts to convert HFIR from using highly enriched uranium (HEU) fuel to low-enriched uranium (LEU) fuel. HFIR must maintain its world-class performance and missions following this conversion, and because 252 Cf is a vital neutron-emitting radioisotope used for a variety of high-impact applications (e.g., reactor startup, cancer treatment), the ability to efficiently produce 252 Cf must be preserved. In this work, the HFIRCON, Shift, ORIGEN, and TCOMP codes were deployed, and several sets of data libraries were investigated to better understand the calculation codes and the data biases. As-loaded target composition data, as-run irradiation history data, and post-irradiation measurements from recent multi-cycle irradiation campaigns of the HEU core were used to validate and determine methodology biases. Further, the findings demonstrated a good agreement, with results falling within 3 standard deviations of measurements. This paper lays the ground work for the second paper, which evaluates and compares 252 Cf production and safety metrics with the HEU core and a proposed LEU core.

07 ISOTOPE AND RADIATION SOURCES↗

Halide Perovskites and Their Derivatives for Efficient, High‐Resolution Direct Radiation Detection: Design Strategies and Applications

Abstract The past decade has witnessed a rapid rise in the performance of optoelectronic devices based on lead‐halide perovskites (LHPs). The large mobility‐lifetime products and defect tolerance of these materials, essential for optoelectronics, also make them well‐suited for radiation detectors, especially given the heavy elements present, which is essential for strong X‐ray and γ‐ray attenuation. Over the past decade, LHP thick films, wafers, and single crystals have given rise to direct radiation detectors that have outperformed incumbent technologies in terms of sensitivity (reported values up to 3.5 × 10 6 µC Gy air −1 cm −2 ), limit of detection (directly measured values down to 1.5 nGy air s −1 ), along with competitive energy and imaging resolution at room temperature. At the same time, lead‐free perovskite‐inspired materials (e.g., methylammonium bismuth iodide), which have underperformed in solar cells, have recently matched and, in some areas (e.g., in polarization stability), surpassed the performance of LHP detectors. These advances open up opportunities to achieve devices for safer medical imaging, as well as more effective non‐invasive analysis for security, nuclear safety, or product inspection applications. Herein, the principles behind the rapid rises in performance of LHP and perovskite‐inspired material detectors, and how their properties and performance link with critical applications in non‐invasive diagnostics are discussed. The key strategies to engineer the performance of these materials, and the important challenges to overcome to commercialize these new technologies are also discussed.

36 MATERIALS SCIENCE↗

A Simple, Revolutionary Approach to Waste Packaging Utilizing Proven Technology - 20201

Historically, removing hazardous waste from gloveboxes involves the use of bags as the primary containment method. This method can prove tedious, repetitive, and time consuming to ensure the process follows all safeguards required to contain the waste and mitigate any breach of containment. Layers of bags, yards of tape, and multiple filters are added to the waste stream in order to transfer the hazardous waste from the glovebox safely into the drum package. Then, finally, it can be shipped and disposed of. The process to cut, tie, and tape each bag for disposal involves manual effort by multiple operators. Following Administrative Safety Controls, good operators are able to safely perform those tasks; but, since the bag is the only confinement layer, incidents can occur. Operators, in some cases, are also at close proximity to this waste which may increase the risk of radiation exposure. Once the waste is transferred out through these bags, it is nearly impossible to remove packaged waste that may contain higher dosage levels, thus increasing drum disposal costs incurred by the facility. Exceeding the allowable radiation levels, and drums not fully filled, both contribute significantly to excess disposal costs. Central Research Laboratories (CRL), based in Red Wing Minnesota, has developed the Waste Drum Transfer System (WDTS) building upon the proven technology and containment of the Rapid Transfer Port (RTP) as an alternate, more efficient method of waste transfer. This solution consists of an RTP Alpha port mounted inside a glovebox and Beta assembly unit composed of a drum liner fitted inside a standard 55 gallon drum. The use of the Beta drum liner bypasses the typical use of bags, sleeves or tape to provide leak tight containment. The process to connect and disconnect a drum from the glovebox is achieved by the self-docking and rotating system controls of the RTP Alpha, all done with only one operator standing in an upright ergonomic position. This system also allows for greater flexibility in available Beta connection options, expanding the overall functionality of the system. This system can be disconnected and reconnected multiple times to maximize volume containment. This will minimize drum disposal costs and reduce the overall volume of waste output by more efficiently filling the drums. Radiation levels inside each drum can be monitored and adjusted more efficiently by operators utilizing the reconnect option. Minimal As Low As Reasonably Achievable (ALARA) levels are also achievable with this system. This paper will show how highly efficient packaging and disposal of hazardous waste can be accomplished in a cost-effective manner utilizing the proven RTP technology. Maximized operator productivity and safety, as well as minimized radiation dose exposure, are all attainable through the system's engineered controls. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Status and prospect of in situ and operando characterization of solid-state batteries

Electrification of the transportation sector relies on radical re-imagining of energy storage technologies to provide affordable, high energy density, durable and safe systems. Next generation energy storage systems will need to leverage high energy density anodes and high voltage cathodes to achieve the required performance metrics (longer vehicle range, long life, production costs, safety). Solid-state batteries (SSBs) are promising materials technology for achieving these metrics by enabling these electrode systems due to the underlying material properties of the solid electrolyte (viz. mechanical strength, electrochemical stability, ionic conductivity). Electro-chemo-mechanical degradation in SSBs detrimentally impact the Coulombic efficiencies, capacity retention, durability and safety in SSBs restricting their practical implementation. Solid|solid interfaces in SSBs are hot-spots of dynamics that contribute to the degradation of SSBs. Characterizing and understanding the processes at the solid|solid interfaces in SSBs is crucial towards designing of resilient, durable, high energy density SSBs. This work provides a comprehensive and critical summary of the SSB characterization with a focus on in situ and operando studies. Additionally, perspectives on experimental design, emerging characterization techniques and data analysis methods are provided. Furthermore, this work provides a thorough analysis of current status of SSB characterization as well as highlights important avenues for future work.

25 ENERGY STORAGE↗

Ecological and genomic variation in ectomycorrhizal fungal exploration types

Ectomycorrhizal fungi (EMF) produce mycelia with variable extension and complexity, which can be classified according to soil ‘exploration types’ (ETs). ETs have received attention as one of the few mycorrhizal trait frameworks, but without an empirical classification of ET functional diversity and environmental preferences, understanding and interpreting EMF biogeographic patterns has been difficult. We conducted a synthesis combining: comparative EMF genomics to describe functional divergence in decomposition and nutrient cycling genes across ETs; and EMF trait distribution modeling across continental Europe, pairing soil and root EMF surveys to establish biogeographic ET niche profiles. We demonstrate a signature of ETs encoded in EMF genomes, which is independent from phylogeny and linked to biomass production strategies. EMF ET relative abundances were separated by soil, root, and dominant tree leaf type habitats and exhibited unique correlations with forest biotic (e.g. plant productivity and plant pathogen densities) and abiotic (e.g. nitrogen deposition and soil pH) conditions. These findings support a theory that EMF niche partitioning can be partially explained by extraradical mycelial traits, with underlying variation in ET biogeography likely arising from distinct decomposition and nutrient cycling potentials. We also identify important limitations to this trait framework and provide a guided outlook for future research.

biogeography↗

Neutronic Safety Analysis of Pu-238 Production at Idaho National Laboratory

This analysis was completed to support the irradiation of plutonium fuel services (PFS) targets in the NEFT in the Advanced Test Reactor (ATR) as a part of the campaign to restart domestic production of plutonium-238 used in radioisotope power systems (RPS) by the National Aeronautical and Space Administration (NASA) and Department of Energy (DOE) Office of Nuclear Energy (NE), Office of Nuclear Infrastructure Program (NE-3). Referred to as the PFS-ATR-GEN1-NEFT experiment, the assembly was designed to hold 46 PFS targets in the NEFT. The scope of this paper is to outline the MOPY method used to calculate the heat generation rates (HGRs), flux, fission density, and quantify the viability of the target design for Pu-238 production in ATR.

07 ISOTOPE AND RADIATION SOURCES↗

Physical Sciences Vistas, Issue 1 2021 [Newsletter]

Issue 1 highlights of the Los Alamos Physical Sciences Vistas newsletter include: Finding and aiding success through the Lab's employee scholarship fund; Volunteer vignettes: helping others throughout Northern New Mexico; X-ray topography instrument reimagined for use at Oregon State University; Potentially activated metal recycle project triples its goal; Adaptive 3D machine-learning method for 3D coherent diffraction imaging; and, Sigma team aims for excellence in safety, quality, productivity.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Remote methane sensor for emissions from pipelines and compressor stations using chirped-laser dispersion spectroscopy

Leak rates of methane (CH 4 ) from the natural gas supply chain result in lost profit from unsold product, public safety and property concerns due to potential explosion hazards, and a potentially large source of economic damages from legal liabilities. Yet large measurement challenges exist in identifying and quantifying CH 4 leak rates along the vast number and type of components in the natural gas supply chain. This is particularly true of the “midstream” components involved in the gathering, processing, compression, transmission, and storage of natural gas. This project developed and deployed new advances in chirped laser dispersion spectroscopy (CLaDS) to detect methane leaks from pipelines, compressor stations, and other midstream infrastructure from a remote position (standoff detection). The system was deployed from a van to measure fugitive methane leaks from a local compressor station as a proof-of-concept. The technique was validated through mobile laboratory measurements with in-situ sensors as well as controlled releases of methane. The system also mapped a plume from a controlled release of methane by tracking a small unmanned aerial system (sUAS) that carried a corner cube retroreflector which reflected the beam back to the instrument. The drone-based system quantified a leak rate to within 30% of the actual rate and localized the emission location within 5 m of the actual release location at standoff distances of 25-45 m. This sUAS-reflector tracking approach has benefits for mapping leak locations remotely using small drones flying around a facility. Benefits of a commercial sensor with these capabilities include reductions of leaks for pipeline operators (more profit), earlier detection of leaks to avoid catastrophic explosion hazards for public health and to mitigate property damage, and reduced methane emissions to the atmosphere (improving air quality).

03 NATURAL GAS↗

Affordable Artificial Intelligence-Assisted Machine Supervision System for the Small and Medium-Sized Manufacturers

With the rapid concurrent advance of artificial intelligence (AI) and Internet of Things (IoT) technology, manufacturing environments are being upgraded or equipped with a smart and connected infrastructure that empowers workers and supervisors to optimize manufacturing workflow and processes for improved energy efficiency, equipment reliability, quality, safety, and productivity. This challenges capital cost and complexity for many small and medium-sized manufacturers (SMMs) who heavily rely on people to supervise manufacturing processes and facilities. This research aims to create an affordable, scalable, accessible, and portable (ASAP) solution to automate the supervision of manufacturing processes. The proposed approach seeks to reduce the cost and complexity of smart manufacturing deployment for SMMs through the deployment of consumer-grade electronics and a novel AI development methodology. The proposed system, AI-assisted Machine Supervision (AIMS), provides SMMs with two major subsystems: direct machine monitoring (DMM) and human-machine interaction monitoring (HIM). The AIMS system was evaluated and validated with a case study in 3D printing through the affordable AI accelerator solution of the vision processing unit (VPU).

3D printing↗

Efficiency Calibration of FGMS Cold Traps

This plan describes tests to determine the efficiency calibrations for the Fission Gas Monitoring System (FGMS) by the measurements of 85Kr and 133Xe gamma rays. FGMS collects fission product gases released from irradiated Advanced Gas Reactor tristructural-isotropic-coated particle fuel specimens during post-irradiation heating in the Fuel Accident Condition Simulator (FACS) furnace. FGMS is composed of two charcoal-filled, liquid-nitrogen cooled traps that are each monitored by a high purity germanium (HPGe) detector. All irradiated Advanced Gas Reactor fuel specimens contain 85Kr (t1/2 = 10.8 year); however, significant short-lived fission products such as 133Xe (t1/2 = 5.2 day) and 131I (t1/2 = 8.0 day) have decayed away by the time they reach the FACS for testing. In order to measure the releases of these short-lived fission products during safety testing in the FACS furnace, a re-irradiation of samples is necessary in the Neutron Radiography Reactor. This requires the FGMS be calibrated for the fission gas 133Xe, in addition to 85Kr. Because any re-irradiated fuel specimen will have both 85Kr and 133Xe present, the collection efficiency from a mixture of krypton and xenon needs to be determined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Teleoperation of Construction Robots Using Human Interaction: Case Study Examples: Preprint

The integration of advanced teleoperation methods in construction robotics has the potential to enhance productivity and safety in demanding environments. Among different methods, hand gestures have emerged as an intuitive approach, enabling seamless communication between human operators and robotic systems. This study demonstrates the use of hand gestures for controlling a model robotic excavator and a virtual robotic arm in construction applications. Two case study examples are presented. In the first case study, a series of hand gestures are performed to control a model robotic excavator's bucket and arm movements. The second case study focuses on using hand gestures to control a virtual robotic arm to perform a material handling task in a simulated environment. In both cases, the performed hand gestures are all successfully captured and interpreted by the gesture-based teleoperation method to conduct the corresponding tasks, which demonstrates the application of the gesture-based control method for various types of construction robots. Also, the limitations of the gesture-based teleoperation method (e.g., recognition delay, sensitivity to motion outliers) are discussed. Future work will focus on developing a digital twin system to support gesture-based teleoperation for a wider range of construction robots.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of Frozen Chemistry for Molten Salt Reactors (MSRs)

Understanding accident progression and the potential/conditions for fission product release from fuel is necessary to evaluate safety for any nuclear reactor system. Molten Salt Reactors (MSRs) under development need such analysis to support safety evaluations. Fission product chemistry specific to MSR concepts is a critical area that introduces distinct considerations relative to the current state-of-knowledge in reactor safety, primarily developed for water-moderated nuclear reactor systems. In Light Water Reactor (LWR) systems, it is necessary to capture the chemical interaction of fission products with the reactor evironment, containment and confinement systems. The overall effects at this point are relatively well understood for the purposes of performing safety evaluations. A key insight from LWR studies is that fission product chemical behavior can be reasonably captured by modeling approaches where the chemistry is "frozen". These modeling approaches assume that radionuclide reaction and speciation can be represented by chemical classes, each with characteristic transport behavior that is invariant under a broad range of thermochemical conditions. However, radionuclides can exhibit a range of behavior in the liquid salt-melt phase of the coolant used in MSRs. Radionuclides, salt, and the metal containment surfaces (i.e. pipes) can co-exist in dynamic equilibrium that could evolve with small system mass changes. A detailed investigation to the degree the equilibrium state can dynamically evolve with changes in the conditions of the molten salt mixture has not been previously conducted. It is currently not well understood where frozen chemistry assumptions are valid. Expanding the state-of-knowledge in this regard is relevant to better assessing the range of chemical effects that should be incorporated as part of MSR safety assessments. This investigation used the Oak Ridge Isotope GENeration (ORIGEN) module of the Standardized Computer-Analysis for Licensing Evaluation (SCALE) code to generate simulated radionuclide inventories for the MSR Experiment (MSRE) and then modeled reactor chemical speciation using the Molten Salt Thermodynamic Database – Thermochemical (MSTDB-TC) coupled with Thermochimica. The effect of composition variation during decay of fission product inventory in a molten salt over a period of 500 days prolonged post- at multiple temperatures was studied. Mass fractions for fluorine and berilium were varied in order to probe the effects of free fluorine control. Finally, speciation of fluoride reactors were showed by comparing MSRE readionuclide inventories with a FLiBe based molten salt breeder reactor (MSBR). The results showed that fission product mass change has little effect on phase mass changes and vapor pressures for fluoride species, but differ with varying carrier and fuel salt compositions. However, iodine species were found to have a vapor pressure not only dependent on temperature, but also the free fluorine potential, releasing iodine when the free fluorine potential is equal to the iodine inventory. This observation, however, arose under free fluorine potentials that are very unlikely to be realized in typical molten salt mixtures. Despite this observation, temperature was found to be the dominant parameter that drove phase change and fission product species vapor pressure. The results indicate that the current frozen chemistry approach is adequate for MSR analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Californium-252 production at the High Flux Isotope Reactor - II: Comparison between the highly enriched uranium and a proposed low-enriched uranium core

This is the second paper on a 252 Cf production study performed in support of efforts to convert the High Flux Isotope Reactor (HFIR) from highly enriched uranium (HEU) to low-enriched uranium (LEU) fuel. The first paper primarily focuses on validating computational tools and nuclear data. This companion paper evaluates another critical aspect: the 252 Cf production capability with a proposed LEU core. HFIR must maintain its world-class performance and missions following conversion and because 252 Cf is a vital, multipurpose neutron-emitting radioisotope, the ability to efficiently produce 252 Cf must be preserved. In this study, the HFIRCON transport and depletion tool, several nuclear data libraries, and Campaign 78 data were used to compute 252 Cf production, sensitivity, and safety metrics. Further, results indicate the 252 Cf production and production rates are slightly higher with a 95MW th LEU core compared with those obtained with the 85MW th HEU core. Additionally, the target peak fission rate densities, discharge cumulative fission densities, and heat deposition rates with the LEU core are within a few percent of those calculated with the HEU core. The findings suggest HFIR’s 252 Cf production capability can be effectively maintained with an LEU core without adversely affecting the safety metrics.

07 ISOTOPE AND RADIATION SOURCES↗

Impact Fracture and Fragmentation of Glass via the 3D Combined Finite-Discrete Element Method

A driving technical concern for the automobile industry is their assurance that developed windshield products meet Federal safety standards. Besides conducting innumerable glass breakage experiments, product developers also have the option of utilizing numerical approaches that can provide further insight into glass impact breakage, fracture, and fragmentation. The combined finite-discrete element method (FDEM) is one such tool and was used in this study to investigate 3D impact glass fracture processes. To enable this analysis, a generalized traction-separation model, which defines the constitutive relationship between the traction and separation in FDEM cohesive zone models, was introduced. The mechanical responses of a laminated glass and a glass plate under impact were then analyzed. For laminated glass, an impact fracture process was investigated and results were compared against corresponding experiments. Correspondingly, two glass plate impact fracture patterns, i.e., concentric fractures and radial fractures, were simulated. The results show that for both cases, FDEM simulated fracture processes and fracture patterns are in good agreement with the experimental observations. The work demonstrates that FDEM is an effective tool for modeling of fracture and fragmentation in glass.

42 ENGINEERING↗

Hydrogen Safety Review for Gas Turbines, SOFC, and High Temperature Hydrogen Production

This report presents an introduction and summary on hydrogen safety issues, as they relate to hydrogen production, storage, and use in the energy sector, primarily as related to electricity generation by gas turbines, and solid oxide fuel cells (SOFC), and hydrogen production from gasification and steam methane reforming processes. The impetus behind this effort is the U.S. DOE goal for decarbonization of the power generation sector by the year 2035. In many cases, hydrogen is expected to replace natural gas as the primary fuel source (or form of energy storage) to achieve this goal. Advanced technologies for large-scale energy production using hydrogen as a fuel source which can be deployed over the next 5–10 years will be required. However, to develop and mature these hydrogen-based technologies, it will be critical to identify the safety issues related to widespread use of hydrogen as a fuel source, so that they may be addressed prior to widespread deployment.

08 HYDROGEN↗