Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Synthesis and analysis of jet fuel from shale oil and coal syncrudes

Thirty-two jet fuel samples of varying properties were produced from shale oil and coal syncrudes, and analyzed to assess their suitability for use. TOSCO II shale oil and H-COAL and COED syncrudes were used as starting materials. The processes used were among those commonly in use in petroleum processing-distillation, hydrogenation and catalytic hydrocracking. The processing conditions required to meet two levels of specifications regarding aromatic, hydrogen, sulfur and nitrogen contents at two yield levels were determined and found to be more demanding than normally required in petroleum processing. Analysis of the samples produced indicated that if the more stringent specifications of 13.5% hydrogen (min.) and 0.02% nitrogen (max.) were met, products similar in properties to conventional jet fuels were obtained. In general, shale oil was easier to process (catalyst deactivation was seen when processing coal syncrudes), consumed less hydrogen and yielded superior products. Based on these considerations, shale oil appears to be preferred to coal as a petroleum substitute for jet fuel production.

Gallagher, J. P.↗

High Temperature Life Testing of 80Ni-20Cr Wire in a Simulated Mars Atmosphere for the Sample Analysis at Mars (SAM) Instrument Suite Gas Processing System (GPS) Carbon Dioxide Scrubber

In support of the GPS for the SAM instrument suite built by NASA/GSFC, a life test facility was developed to test the suitability of 80Ni-20Cr alloy wire, 0.0142 cm diameter, for use as a heater element for the carbon dioxide scrubber. The element would be required to operate at 1000 C in order to attain the 800 C required for regeneration of the getter. The element also would need to operate in the Mars atmosphere, which consists mostly of CO2 at pressures between 4 and 12 torr. Data on the high temperature degradation mechanism of 80Ni- 20Cr in low pressure CO2, coupled with the effects of thermal cycling, were unknown. In addition, the influence of work hardening of the wire during assembly and the potential for catastrophic grain growth also were unknown. Verification of the element reliability as defined by the mission goals required the construction of a test facility that would accurately simulate the duty cycles in a simulated Mars atmosphere. The experimental set-up, along with the test protocol and results will be described.

Hoffman, Christopher↗

High Temperature Life Testing of 80Ni-20Cr Wire in a Simulated Mars Atmosphere for the Sample Analysis at Mars (SAM) Instrument Suit Gas Processing System (GPS) Carbon Dioxide Scrubber

In support of the GPS for the SAM instrument suite built by GSFC, a life test facility was developed to test the suitability of 80Ni-20Cr wire, 0.0056 inches in diameter, for use as a heater element for the carbon dioxide scrubber. The wire would be required to operate at 1000 C in order to attain the 800 C required for regeneration of the getter. The wire also would need to operate in the Mars atmosphere, which consists mostly of CO2 at pressures between 4 and 12 torr. Data on the high temperature degradation mechanism of 80Ni-20Cr in low pressure CO2, together with the effects of thermal cycling, were unknown. In addition, the influence of work hardening of the wire during assembly and the potential for catastrophic grain growth also were unknown. Verification of the wire reliability as defined by the mission goals required the construction of a test facility that would accurately simulate the duty cycles in a simulated Mars atmosphere. The experimental set-up, along with the test protocol and results will be described.

Gundersen, Cynthia↗

Novel End-to-End Molecular Biology Approach for Direct Nanopore 1D cDNA Sequencing of Reverse Transcribed mRNAs Purified from Cell Cultures by the NASA ISS WetLab2 SPM

Continued space bioscience research onboard the International Space Station (ISS) and future long-duration flight missions to the Moon or Mars will require the ability to conduct on-orbit molecular analysis of biological samples independently from Earth. In the last year two new molecular analytic technologies have been installed and the technologies demonstrated onboard the ISS: The Sample Prep Module (SPM) WetLab-2 (WL2) qRT-PCR toolbox and the Oxford Nanopore MinIon Biomolecule Sequencer. Here we describe protocol development and integration into existing ISS technology for end-to-end on-orbit biological sample processing and molecular analysis with real time results generated utilizing only field offline analytic software. For this experiment we isolated primary cells from bone marrow flushes of wild type B6129SF2 mice (Jackson Labs) long bones. The cell isolate was then processed using the SPM to produce total 147nanograms of RNA. The total RNA was purified to only messenger RNA (mRNA) and transferred to Smartcycler Thermocycle ISS kit consumable tube using Eppendorf gel loading pipette tips for further processing. Complementary first strand cDNA was synthesized using OLIGO dT priming followed by addition of SuperScript II Reverse Transcriptase and thermal cycling as per manufacturers instruction. All thermal cycling was conducted using the ISS WetLab-2 Cephid Smarcycler real time thermal cycler. Our protocol takes advantage of mRNAs native poly(A) tail, synthesized in vivo to protect the mRNA from degradation by endonucleases, to eliminate end-prep for adapter ligation. The adapted library is purified using MyOne C1 Streptavidin beads before elution in buffer. The pre-sequencing library is diluted in the loading buffer and injected into the MinIon sample port, drawn into the nanopore window by capillary action, and sequenced using the MinKnown software with local basecalling. The sequencing read produced 34.5 million events and local basecalling produced 117,301 successful reads. NCBI Blast of the data for the mouse genome resulted in 2,462 successful nucleotide collection matches (gene sequences) exceeding 70 homology. These results demonstrate the viability of this novel flight ready end-to-end sample analytic methodology and provide a real time homolog for flight experimentation utilizing supply kits and technologies that have already been demonstrated on ISS.

MinIon↗

Monitoring Astronaut Health with DNA Sequencing

In recent years microbe a plethora of microbe populations have been identified onboard the ISS (International Space Station). Approaches for real-time tracking of microbes for routine housekeeping and food/water safety monitoring will be critical for mission safety and crew health on future longer duration missions to the Moon or Mars. This work is a proof-of-concept study demonstrating an end-to-end phylogenetic identification and full genome sequencing effort of multiple microbial populations. Our methodology utilized the ISS flight-certified WetLab-2 molecular toolbox and the Biomolecule Sequencer projects for real-time end-to-end on-orbit microbial biological samples processing and molecular analysis with real time results generated utilizing only field "offline" analytic software. For this experiment we colony-cultured several ISS isolated microorganisms before generation of the pre-sequencing library via the automated VolTRAX device which enabled high library turnover with little wet-bench activity or potential future costly astronaut time. The pre-sequencing library is diluted in loading buffer and injected into the MinION sample port, drawn into the nanopore window by capillary action, and sequenced using the MinKnown. 16S and full genome alignment, nucleotide matching, gene identification, and phylogenetic sorting was accomplished utilizing the Epi2me software and the offline NCBI Blast viral, microbiome, and human somatic databases. In short, the methodologies developed herein replace the myriad of specific, often highly targeted microbiological tests used in the clinical laboratory, which would be difficult if not impossible to currently implement aboard the ISS or in deep space, with a single metagenomics test.

genomics↗

Composite structural materials

Progress is reported in studies of constituent materials composite materials, generic structural elements, processing science technology, and maintaining long-term structural integrity. Topics discussed include: mechanical properties of high performance carbon fibers; fatigue in composite materials; experimental and theoretical studies of moisture and temperature effects on the mechanical properties of graphite-epoxy laminates and neat resins; numerical investigations of the micromechanics of composite fracture; delamination failures of composite laminates; effect of notch size on composite laminates; improved beam theory for anisotropic materials; variation of resin properties through the thickness of cured samples; numerical analysis composite processing; heat treatment of metal matrix composites, and the RP-1 and RP2 gliders of the sailplane project.

Ansell, G. S.↗

A new approach to mass spectrometer measurements of thermospheric density

The gas sampling problem in satellite and high velocity probes was investigated by applying the theory of a drifting Maxwellian gas. A lens system using a free stream ion source was developed and experimentally evaluated over the pressure range of 0.00001 to 0.01 N/m sq (approx. 10 to the minus 7th power to 0.0001 torr). The source has high beam transparency, which minimizes gas-surface collisions within, or near, the ionization volume. It is shown that for high ion energy (60 eV), the extracted ion beam has an on-axis energy spread of less than 4 eV, and that 90 percent of the ions are within 2.5 deg of the beam axis. It is concluded that the molecular beam mass spectrometer concept, developed for gas density measurements in the upper atmosphere, substantially reduces gas-surface scattering and gas-surface reactions in the sample, and preserves the integrity of the gas sample during the analysis process. Studies show that both the Scout and Delta launch vehicles have adequate volume, control, velocity, and data acquisition capability necessary to obtain thermospheric number density in real time.

Melfi, L. T., Jr.↗

Process Research of Polycrystalline Silicon Material (PROPSM)

A passivation process (hydrogenation) that will improve the power generation of solar cells fabricated from presently produced, large grain, cast polycrystalline silicon (Semix), a potentially low cost material are developed. The first objective is to verify the operation of a DC plasma hydrogenation system and to investigate the effect of hydrogen on the electrical performance of a variety of polycrystalline silicon solar cells. The second objective is to parameterize and optimize a hydrogenation process for cast polycrystalline silicon, and will include a process sensitivity analysis. The sample preparation for the first phase is outlined. The hydrogenation system is described, and some early results that were obtained using the hydrogenation system without a plasma are summarized. Light beam induced current (LBIC) measurements of minicell samples, and their correlation to dark current voltage characteristics, are discussed.

Culik, J. S.↗

An overview of the Space Station Freedom environmental health system

The proposed environmental health system (EHS) designed for the closed environment of the Space Station is examined. The internal contamination control and environmental health considerations for the Space Station are discussed. The microbiology, toxicology, water quality, radiological health, vibroacoustics, and barothermal physiology subsystems of the EHS are described. Proposed capabilities of the EHS are: the environmental sample collection, processing, and analysis of the breathing atmosphere, potable and hygiene water, and internal surfaces.

Richard, Elizabeth E.↗

Development of the Space Station Freedom Environmental Health System

The Environmental Health System (EHS), a subsystem of the Space Station Freedom (SSF) Crew Health Care System, was established to ensure that crewmembers will have a safe and healthy environment in which to live and work. EHS is comprised of six subsystems: Microbiology, Toxicology, Water Quality, Radiological Health, Vibroacoustics, and Barothermal Physiology. Each subsystem contributes to the overall functions of the EHS including environmental planning, environmental monitoring, environmental monitoring, environmental health assessments, and operations support. The EHS will provide hardware for monitoring the air, water, and internal surfaces of Freedom, including capabilities for inflight sample collection, processing, and analysis. The closed environment of SSF, and its dependence on recycled air and water, will necessitate a reliable monitoring system to alert crewmembers if contamination levels exceed the maximum allowable limits established to ensure crew health and safety. This paper describes the functions and hardware design status of the EHS.

Richard, Elizabeth E.↗

STS-95 Day 08 Highlights

On this eighth day of the STS-95 mission, the flight crew, Cmdr. Curtis L. Brown, Pilot Steven W. Lindsey, Mission Specialists Scott E. Parazynski, Stephen K. Robinson, and Pedro Duque, and Payload Specialists Chiaki Mukai and John H. Glenn, continue to perform microgravity experiments. Specialist John Glenn completes a back-pain questionnaire as part of a study of how the muscle, intervertebral discs and bone marrow change due to microgravity. The results will then be compared with data provided by astronauts during previous missions. Glenn continues blood sample analysis and blood processing that are part of the Protein Turnover (PTO) experiment, which is studying the muscle loss that occurs during space flight.

Source record↗

Portable Device Analyzes Rocks and Minerals

inXitu Inc., of Mountain View, California, entered into a Phase II SBIR contract with Ames Research Center to develop technologies for the next generation of scientific instruments for materials analysis. The work resulted in a sample handling system that could find a wide range of applications in research and industrial laboratories as a means to load powdered samples for analysis or process control. Potential industries include chemical, cement, inks, pharmaceutical, ceramics, and forensics. Additional applications include characterizing materials that cannot be ground to a fine size, such as explosives and research pharmaceuticals.

Source record↗

Simulation of Radiation-Induced DNA Damage With the Code RITRACKS

INTRODUCTION DNA damage is one of the most physiologically important effects of ionizing radiation. Clustered DNA damage events, like double-strand breaks (DSBs), have the most notable biological consequences. DNA damage types depend on both the track structure of the radiation and the spatial organization of the DNA. High linear energy transfer (LET) charged nuclei, found in galactic cosmic rays (GCR), are known to produce large numbers of complex DNA damage events. The human genome is packaged into chromatin, which can take on locus-dependent and cell type-dependent spatial conformations that correspond to epigenetic states, such as more open, extended structures in transcriptionally active chromatin. These epigenetic differences can affect DNA break patterns in response to ionizing radiation, potentially creating distinct DNA repair and signaling outcomes across the genome in different cells. MATERIAL AND METHODS The code RITRACKS (Relativistic Ion Tracks), which simulates stochastic radiation track structures and radiation chemistry, was used to model damage on isolated and histone-bound DNA by various types of ions and photons. The changes made to the code to perform radiation-induced DNA damage, and simulation results on single nucleosomes are given in our recent paper. In this work, the DNA building capabilities of RITRACKS have been extended to simulate more complex DNA structures build on the coarse-grain simulation framework meso-WLCsim. This code can sample generic chromatin fiber conformation ensembles based on the geometry of nucleosomes and mechanical properties of DNA. Using RITRACKS, we simulated the fragment length distributions (FLD) of irradiated DNA structures built using the chromatin conformations of WLCsim and obtained results representative of those obtained with Radiation-Induced Correlated Cleavage with sequencing (RICC-Seq) experiments [6]. We have also performed Fe ion and photon irradiations of K562, IMR90, BJ and RPE-1 cells at NSRL to experimentally validate results. Sample processing and data analysis are in progress and any available preliminary results will be discussed. DISCUSSION The recent updates in the code RITRACKS allow the calculation of several quantities such as the DNA damage yield and the FLD. This approach can be used to model epigenetic state-specific chromatin structure parameters to leverage the epigenetic state data available for many human cell types to infer relative DNA damage sensitivity among genomic loci.

I Plante↗

Design and Development of a Miniaturized Double Latching Solenoid Valve for the Sample Analysis at Mars Instrument Suite

The development of the in-house Miniaturized Double Latching Solenoid Valve, or Microvalve, for the Gas Processing System (GPS) of the Sample Analysis at Mars (SAM) instrument suite is described. The Microvalve is a double latching solenoid valve that actuates a pintle shaft axially to hermetically seal an orifice. The key requirements and the design innovations implemented to meet them are described.

Smith, James T.↗

Sample processor for chemical analysis

An apparatus is provided which can process numerous samples that must be chemically analyzed by the application of fluids such as liquid reagents, solvents and purge gases, as well as the application of dumps for receiving the applied fluid after they pass across the sample, in a manner that permits numerous samples to be processed in a relatively short time and with minimal manpower. The processor includes a rotor which can hold numerous cartridges containing inert or adsorbent material for holding samples, and a pair of stators on opposite sides of the rotor. The stators form stations spaced along the path of the cartridges which lie in the rotor, and each station can include an aperture in one stator through which a fluid can be applied to a cartridge resting at that station, and an aperture in the other stator which can receive the fluid which has passed through the cartridge. The stators are sealed to the ends of the cartridges lying on the rotor, to thereby isolate the stations from one another.

Boettger, Heinz G.↗

Materials processing in low gravity

Activities of the Materials Processing in Low Gravity Program in which the University of Alabama in Huntsville (UAH) designed, fabricated, and performed various low gravity experiments in materials processing between October 26, 1988 through October 25, 1989 are discussed. Details of low gravity experiments using the Drop Facilities at the Marshall Space Flight Center (MSFC) and the KC-135 aircraft at Ellington Field are discussed. This effort included the defining of experimental requirements and equipment, experiment-facility integration requirements, building/assembling the necessary experiment apparatus, and conducting experiments which will contribute to the knowledge base for commercialization of materials processing in low gravity. UAH also performed logistical support needed to execute the experimentation, the necessary sample preparation, metallography analysis, and physical properties measurements of the processed samples.

Workman, Gary L.↗

Investigating Amino Acid Heterogeneity in Milligram-Scale Samples of the Murchison CM2 Carbonaceous Chondrite

Analyses of different aliquots of the Tagish Lake meteorite have resulted in amino acid abundance variations of an order of magnitude or more, even when performed using the same techniques, by the same personnel, in the same laboratories (e.g., Simkus et al. 2019). Up to ~five-fold variations have been observed for specific amino acids in different samples of the same meteorite, such as α aminoisobutryic acid (AIB) in Murchison. These variations are often attributed differing sample composition or differing alteration history, neither of which is mutually exclusive. Distinguishing between these two explanations is challenging and time consuming, requiring detailed mineralogical analyses to be performed in conjunction with high precision organics analysis. The potential for innate sample-level heterogeneity presents a significant complication when parsing the effects of different processes or conditions during preparation of meteorite samples for analysis, as differences in organic yields or abundances could be due to differences in laboratory processing or differences among the samples themselves. In this work, we investigated the degree of innate organic heterogeneity present in a single ~250 mg chip of divided into 21 samples.

A. S. Burton↗

Towards a Theory of Sampled-Data Piecewise-Deterministic Markov Processes

The analysis and design of practical control systems requires that stochastic models be employed. Analysis and design tools have been developed, for example, for Markovian jump linear continuous and discrete-time systems, piecewise-deterministic processes (PDP's), and general stochastic hybrid systems (GSHS's). These model classes have been used in many applications, including fault tolerant control and networked control systems. This paper presents initial results on the analysis of a sampled-data PDP representation of a nonlinear sampled-data system with a jump linear controller. In particular, it is shown that the state of the sampled-data PDP satisfies the strong Markov property. In addition, a relation between the invariant measures of a sampled-data system driven by a stochastic process and its associated discrete-time representation are presented. As an application, when the plant is linear with no external input, a sufficient testable condition for the convergence in distribution to the invariant delta Dirac measure is given.

Herencia-Zapana, Heber↗