Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Pressure sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

404 records · Page 2

Glancing Angle Deposition in Gas Sensing: Bridging Morphological Innovations and Sensor Performances

Glancing Angle Deposition (GLAD) has emerged as a versatile and powerful nanofabrication technique for developing next-generation gas sensors by enabling precise control over nanostructure geometry, porosity, and material composition. Through dynamic substrate tilting and rotation, GLAD facilitates the fabrication of highly porous, anisotropic nanostructures, such as aligned, tilted, zigzag, helical, and multilayered nanorods, with tunable surface area and diffusion pathways optimized for gas detection. This review provides a comprehensive synthesis of recent advances in GLAD-based gas sensor design, focusing on how structural engineering and material integration converge to enhance sensor performance. Key materials strategies include the construction of heterojunctions and core–shell architectures, controlled doping, and nanoparticle decoration using noble metals or metal oxides to amplify charge transfer, catalytic activity, and redox responsiveness. GLAD-fabricated nanostructures have been effectively deployed across multiple gas sensing modalities, including resistive, capacitive, piezoelectric, and optical platforms, where their high aspect ratios, tailored porosity, and defect-rich surfaces facilitate enhanced gas adsorption kinetics and efficient signal transduction. These devices exhibit high sensitivity and selectivity toward a range of analytes, including NO2, CO, H2S, and volatile organic compounds (VOCs), with detection limits often reaching the parts-per-billion level. Emerging innovations, such as photo-assisted sensing and integration with artificial intelligence for data analysis and pattern recognition, further extend the capabilities of GLAD-based systems for multifunctional, real-time, and adaptive sensing. Finally, current challenges and future research directions are discussed, emphasizing the promise of GLAD as a scalable platform for next-generation gas sensing technologies.

Chemistry

Observing low-altitude features in ozone concentrations in a shoreline environment via uncrewed aerial systems

Abstract. Ozone is a pollutant formed in the atmosphere by photochemical processes involving nitrogen oxides (NOx) and volatile organic compounds (VOCs) when exposed to sunlight. Tropospheric boundary layer ozone is regularly measured at ground stations and sampled infrequently through balloon, lidar, and crewed aircraft platforms, which have demonstrated characteristic patterns with altitude. Here, to better resolve vertical profiles of ozone within the atmospheric boundary layer, we developed and evaluated an uncrewed aircraft system (UAS) platform for measuring ozone and meteorological parameters of temperature, pressure, and humidity. To evaluate this approach, a UAS was flown with a portable ozone monitor and a meteorological temperature and humidity sensor to compare to tall tower measurements in northern Wisconsin. In June 2020, as a part of the WiscoDISCO20 campaign, a DJI M600 hexacopter UAS was flown with the same sensors to measure Lake Michigan shoreline ozone concentrations. This latter UAS experiment revealed a low-altitude structure in ozone concentrations in a shoreline environment showing the highest ozone at altitudes from 20–100 m a.g.l. These first such measurements of low-altitude ozone via a UAS in the Great Lakes region revealed a very shallow layer of ozone-rich air lying above the surface.

Meteorology & Atmospheric Sciences

Multi-sensor Observations of a High-velocity Fireball over the South Atlantic on 2026 April 1

A high-velocity fireball was detected over the South Atlantic (41.9°S, 54.7°W) on 2026 April 1 at 02:13:14 UTC by U.S. Government (USG) sensors, with peak brightness at 90.5 km altitude. The event was well-observed from geostationary orbit by two civilian lightning imagers with near-orthogonal geometry, the Geostationary Operational Environmental Satellite-East Geostationary Lightning Mapper (GLM) and the Exploitation of Meteorological Satellites Meteosat Third Generation Imager 1 Lightning Imager, and it produced low-frequency acoustic signatures. The GLM measured a total radiated energy of 2.4 × 10 10 J, corresponding to a calculated impact energy of 0.086 kt TNT equivalent. Stereoscopic triangulation of the imager tracks yields an independent pre-atmospheric velocity of ~57 km s −1 , some 18% below the USG-reported value. Because orbital provenance is acutely sensitive to the entry velocity, whose reported uncertainty could be substantial, this discrepancy is notable. We document the multi-sensor record and identify the analysis required to assess provenance, which a subsequent study will present.

Silber, Elizabeth Allaryce [Sandia National Lab. (

Material Properties and Modeling of Room Temperature Vulcanizing Silicone

Room Temperature Vulcanizing silicone (RTV) is a high-temperature adhesive that has successfully been used as a gap-filler between Thermal Protection System (TPS) tiles for heatshields on numerous missions. It is also used to bond instrumentation plugs such as temperature and pressure sensors into the heatshields. While RTV has been traditionally assumed to be a non-porous and non-ablating material, numerous experiments have shown that RTV pyrolyzes and becomes highly porous as it is heated. Heating RTV has also shown swelling, or intumescence, which can pose unique problems that lead to roughness induced boundary-layer transition, surface oxide formation and contamination of heat shield sensors. Therefore, it is crucial to understand and model the intumescence phenomenon of RTV. As data for RTV material properties is limited, the first step in modeling RTV is to collect material properties such as pyrolysis mass-loss, microstructure change, virgin and char porosity, etc. which was performed in our initial study. Additionally, thermomechanical properties such as Young’s modulus and Poisson ratio are required for modeling the intumescence of RTV, which were taken from literature and the coefficient of thermal expansion was collected using in-situ heating and Micro Computed Tomography (µ-CT) in previous studies. Finally, numerous other properties such as pyrolysis gas properties, virgin and char thermal conductivity and specific heat were compiled from previous experiments and literature into a material database that can be used for simulations. In Porous Material Analysis Toolbox based on OpenFOAM (PATO) [4], structural mechanics coupled with material response was used for simulating the intumescence of RTV as it is heated. However, since the permeability of the material is very low, the pyrolysis gas creates an internal pressure build-up as the material is being heated, significantly contributing to the deformation of the material. To correctly characterize this phenomenon, additional physics models were implemented into PATO's stress analysis solver, and results were compared with RTV dilatometry test data as a preliminary verification case. Future work will include experiments of RTV at the Plasmatron X facility and the in-situ heating cell with µ-CT, and improvement of simulation tools to more accurately model RTV intumescence.

PATO

An Efficient Approach to Collect Inlet Characterization Data

This report considers a novel process to acquire performance data for supersonic mixed compression inlets that is faster, and therefore less costly, than the previous one. In the previous process, measurements were recorded in discrete increments. The backpressuring actuator was advanced, there was a pause to allow for airflow fluctuations to diminish, and then the measurements were recorded. While this process was methodical, reliable and accurate, it consumed significant wind-on time. In general, high-speed wind tunnels are expensive to operate considering maintenance, energy and human resource requirements. Furthermore, many facilities, such as blowdown wind tunnels, are limited in the duration that they can maintain the desired test condition. Consequently, a quick method to collect the measurements is desired. A favored approach has the actuator moving in a continuous fashion with measurements recorded as the actuator continuously progresses through the increment points. This approach, identified as the dynamic inlet characteristic data acquisition procedure, uses in situ dynamic high-speed pressure sensors to measure pressure signals. While faster, continuous movement adds dynamic effects to the data. To better understand these dynamic effects and other potential influences, a study was undertaken to compare wind tunnel measurements taken at discrete actuator position points with data gathered during continuous actuator movement. Specially, plots of inlet pressure recovery versus mass capture ratio, or total pressure characteristic curves, were examined. The data were measured during experiments in the NASA Glenn Research Center Abe Silverstein 10- by 10-Foot Supersonic Wind Tunnel (SWT) with an inlet propulsion test article. In this report, the wind tunnel experiment and the study objectives are described. The processes to reduce the data and for analysis are explained. A discussion of the results along with features noted in the data is given. Finally, conclusions from this study that may be used to guide future wind tunnel experiment planning are presented.

Inlet

An Efficient Approach to Collect Inlet Characterization Data

This report considers a novel process to acquire performance data for supersonic mixed compression inlets that is faster, and therefore less costly, than the previous one. In the previous process, measurements were recorded in discrete increments. The backpressuring actuator was advanced, there was a pause to allow for airflow fluctuations to diminish, and then the measurements were recorded. While this process was methodical, reliable and accurate, it consumed significant wind-on time. In general, high-speed wind tunnels are expensive to operate considering maintenance, energy and human resource requirements. Furthermore, many facilities, such as blowdown wind tunnels, are limited in the duration that they can maintain the desired test condition. Consequently, a quick method to collect the measurements is desired. A favored approach has the actuator moving in a continuous fashion with measurements recorded as the actuator continuously progresses through the increment points. This approach, identified as the dynamic inlet characteristic data acquisition procedure, uses in situ dynamic high-speed pressure sensors to measure pressure signals. While faster, continuous movement adds dynamic effects to the data. To better understand these dynamic effects and other potential influences, a study was undertaken to compare wind tunnel measurements taken at discrete actuator position points with data gathered during continuous actuator movement. Specially, plots of inlet pressure recovery versus mass capture ratio, or total pressure characteristic curves, were examined. The data were measured during experiments in the NASA Glenn Research Center Abe Silverstein 10- by 10-Foot Supersonic Wind Tunnel (SWT) with an inlet propulsion test article. In this report, the wind tunnel experiment and the study objectives are described. The processes to reduce the data and for analysis are explained. A discussion of the results along with features noted in the data is given. Finally, conclusions from this study that may be used to guide future wind tunnel experiment planning are presented.

Data Acquisition

Effect of Biomass Water Dynamics in Cosmic-Ray Neutron Sensor Observations: A Long-Term Analysis of Maize–Soybean Rotation in Nebraska

Precise soil water content (SWC) measurement is crucial for effective water resource management. This study utilizes the Cosmic-Ray Neutron Sensor (CRNS) for area-averaged SWC measurements, emphasizing the need to consider all hydrogen sources, including time-variable plant biomass and water content. Near Mead, Nebraska, three field sites (CSP1, CSP2, and CSP3) growing a maize–soybean rotation were monitored for 5 (CSP1 and CSP2) and 13 (CSP3) years. Data collection included destructive biomass water equivalent (BWE) biweekly sampling, epithermal neutron counts, atmospheric meteorological variables, and point-scale SWC from a sparse time domain reflectometry (TDR) network (four locations and five depths). In 2023, dense gravimetric SWC surveys were collected eight (CSP1 and CSP2) and nine (CSP3) times over the growing season (April to October). The N0 parameter exhibited a linear relationship with BWE, suggesting that a straightforward vegetation correction factor may be suitable (fb). Results from the 2023 gravimetric surveys and long-term TDR data indicated a neutron count rate reduction of about 1% for every 1 kg m−2 (or mm of water) increase in BWE. This reduction factor aligns with existing shorter-term row crop studies but nearly doubles the value previously reported for forests. This long-term study contributes insights into the vegetation correction factor for CRNS, helping resolve a long-standing issue within the CRNS community.

Chemistry

Landsat Instrument Suite (LandIS) Sensor Design for the Landsat 10 Mission

Landsat 10 will be the upcoming mission in the 50+ year Landsat series of Earth observation platforms. The centerpiece of the observatory will be a super-spectral imager known as the Landsat Instrument Suite (LandIS). The sensor will feature 26 spectral channels from the visible through near-, short-wave, and thermal infrared wavelengths with spatial resolutions of 10, 20, and 60 meters on the ground, depending on the band. These enhancements over the legacy Landsat instruments will ensure data continuity with the existing archive and will expand upon the core Landsat capabilities to enable new applications in Earth science. After a competitive procurement, NASA selected the design submitted by the Raytheon Company for the LandIS instrument. The innovative Raytheon instrument concept utilizes an advanced whiskbroom architecture to fulfill the strict radiometric, spatial, and geometric image quality requirements demanded by the Landsat 10 mission and fits within restrictive mass, volume, and power constraints. The instrument will continue the Landsat directive to image all daylit land and near-shore water areas, along with select nighttime imaging. On-board calibration source data will ensure high radiometric and geometric accuracy and stability consistent with previous missions to enable continuity in data products available to users. This paper discusses the driving requirements for LandIS and provides a description of the chosen design and operations concept of the instrument.

Requirements

Community Resilience Through Rapid Restoration Leveraging Distributed Energy Resources (DERs) and Low-Cost Sensors

Equitable and automated bottoms-up power restoration following an extreme event will be demonstrated at a site in Puerto Rico. To do so, the team will develop enhanced grid situational awareness techniques integrating behind-the-meter (BTM) distributed energy resources (DER) discovery, impedance sweeping based outage boundary detection, and feasible restoration path identification algorithms. Resilience metric will be developed and incorporated along with situational awareness information in a distributed Model Predictive Control (MPC)-based restoration optimization algorithm to control and mobilize grid assets. These algorithms will be validated through power hardware-in-the-loop experiments and ultimately, a site demonstration to show that outage recovery time and total recovered load could be improved by >20% over the baseline.

24 POWER TRANSMISSION AND DISTRIBUTION

Implementation of A Self-Controlling Heater

Temperature control of radiation sensors, targets, and other critical components is a common requirement in modern scientific instruments. Conventional control systems use a heater and a temperature sensor mounted on the body to be controlled. For proportional control, the sensor provides feedback to circuitry which drives the heater with an amount of power proportional to the temperature error. It is impractical or undesirable to mount both a heater and a sensor on certain components such as ultra-small parts or thin filaments. In principle, a variable current through the element is used for heating, and the change in voltage drop due to the element's temperature coefficient is separated and used to monitor or control its own temperature. Since there are no thermal propagation delays between heater and sensor, such control systems are exceptionally stable.

Maxwell G Strange

Scalable multiplexed machine learning gas sensor chips for food classification

Multiplexed gas sensor arrays combined with machine learning have unlocked previously inaccessible applications for scent-based sensing. Current platforms are limited by overlapping sensing materials with similar compositions, leading to highly correlated responses, or multistep deposition processes that hinder scalability. In this work, we developed a 16-element monolithic chip with fully distinct sensing layers, enabling a truly heterogeneous array. The system consists of highly sensitive carbon nanotube field effect transistors that are functionalized through a single-step microdispensing method compatible with automated pipetting systems. The resulting chip produces characteristic signal patterns in response to object-specific scent profiles and, when combined with machine learning algorithms, can perform automated object identification. We demonstrate the classification of 16 different objects, including food spoilage and nut allergens, with a 92.6% overall prediction accuracy.

Bassil, Carla [University of California, Berkeley,

Evaluation of 3D pixel silicon sensors for the CMS Phase-2 Inner Tracker

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R&D program, aiming at using 3D pixel silicon sensors in the innermost barrel layer of the detector, has been carried out by CMS in collaboration with the FBK (Trento, Italy) and CNM (Barcelona, Spain) foundries. The sensors will feature a pixel cell size of 25 × 100 µm 2 , with a centrally located electrode connected to the readout chip. The sensors are read out by the RD53A and CROCv1 chips, developed in 65 nm CMOS technology by the RD53 Collaboration, a joint effort between the ATLAS and CMS groups. This paper reports the results achieved in beam test experiments before and after irradiation, up to a fluence of approximately 2 . 6 × 1 0 16 n eq /cm 2 . Measurements of assemblies irradiated to a fluence of 1 × 10 16 n˙eq/cm 2 show a hit detection efficiency higher than 96% at normal incidence, with fewer than 2% of channels masked, across a bias voltage range greater than 50 V . Even after irradiation to a higher fluence of 1.6 × 10 16 n˙eq/cm 2 , similar performance is maintained over a bias voltage range of 30 V , remaining well within CMS requirements.

3D pixel

Cold Spray Cobalt Magnetostrictive Electromagnetic Acoustic Transducers for High Temperature Structure Monitoring

The Department of Energy’s Advanced Sensors and Instrumentation program seeks to develop and qualify advanced sensors for the nuclear industry. Reliable high temperature and high radiation sensors for detection and characterization of structural flaws in pipes, vessels, and structurally critical components is a weakness for both conventional light water reactors with coolant T-hot approaching 350oC, and for advanced reactors with T-hot temperatures in excess of 500 to 800oC. Magnetostrictive Electromagnetic Acoustic Transducers using a cold spray cobalt coating have been proposed as a sensor design that can withstand these kinds of temperatures and radiation levels to serve as online sensors to detect flaws before cracks, pits, or erosion/corrosion flaws progress to through-wall failures. This report tests cold spray cobalt as part of a magnetostrictive EMAT for high temperature service. Cobalt is known to have strong magnetostrictive properties however the effect of cold spray application is not well studied. This program was surprised to discover that cold sprayed cobalt exhibited little or no magnetostrictive behavior until it was thermally annealed. Following annealing to 650oC however, cold spray cobalt did exhibit a magnetostrictive response. Work to date prior to this milestone report publication showed that magnetostrictive EMAT was successfully tested to 400oC with an alnico permanent magnet. The program plans to extend testing with an electromagnet to higher temperatures. This follow-on work will be reported under subsequent publications or as a revision to this report.

Glass, Samuel W.

The Operational NASA Anomaly Gas Analyzer and Exploration Follow-Ons

The NASA Anomaly Gas Analyzer (AGA) is the culmination of nearly ten years of advancement of core technology originally developed by Vista Photonics through the Small Business Innovation Research (SBIR) program and expanded using NASA program funding. The AGA is a portable, battery operated, optical gas detection instrument for continuous monitoring of H 2 O, CO 2 , O 2 , CO, NH 3 , HCN, HF, HCl in the spacecraft environment. Real time, in-situ monitored, gas concentrations are communicated at 1 Hz through a built-in display on-orbit and additionally through a serial interface on the ground. The instruments function over the typical range of temperatures and pressures required for the spacecraft environment. A ten-year operational life is targeted. Seven AGA instruments are currently deployed on the International Space Station and two Orion-specific units are manifested for Artemis 2. A variation of the operational AGA is under development for lunar Human Landing Systems. A wider calibrated operating pressure envelope is required in this application. Otherwise, the instruments straightforwardly address lessons learned from the original AGA by improving aspects of thermal control, ruggedness, and ease-of-use. A subset of AGA-developed sensed gases (H 2 O, CO 2 , O 2 ) is the subject of the Primary Constituent Monitor (PCM) development for the Habitation and Logistics Outpost (HALO) destined for lunar orbit. Two PCMs will be installed in HALO as part of the environmental control loop where they will interface with vehicle power and communications. While the basic sensor techniques are unchanged from the AGA, these instruments have been radiation hardened to survive for many years in the harsh target environment. Current development status for these instruments will be presented along with recent developments of a naval submarine variant.

ECLSS

The Hyperspectral Microwave Photonic Instrument (HyMPI) and its NEDT Performance

This work presents an overview of a hyperspectral microwave-photonic spectrometer and demonstrates the system end-to-end noise equivalent delta temperature (NEDT) performance. The system aims at augmenting the remote sensing capability from space, with a focus on the Earth’s planetary boundary layer (PBL) thermal microwave (MW) spectral region (0-200 GHz). Combining a Photonic Integrated Circuit (PIC) channelizer and an application-specific integrated circuit (ASIC) spectrometer, the PIC & ASIC (PICASIC) module is capable of processing 40 GHz spectra at hyperspectral (4 MHz) resolution. The photonic technology is agnostic to the spectral region and multiple photonic modules can cover the entire 200 GHz spectrum. Measured results of the end-to-end system NEDT agree with predicted values confirming that the NEDT is primarily dominated by the noise figure of the MW front-end, with the optical link adding no significant noise. The data also demonstrate that a single module enables simultaneous super- and hyper-spectral resolution channel analysis across a 40 GHz range.

spectrometer

The Operational NASA Anomaly Gas Analyzer and Exploration Follow-Ons

The NASA Anomaly Gas Analyzer (AGA) is the culmination of nearly ten years of advancement of core technology originally developed by Vista Photonics through the Small Business Innovation Research (SBIR) program and expanded using NASA program funding. The AGA is a portable, battery operated, optical gas detection instrument for continuous monitoring of H 2 O, CO 2 , O 2 , CO, NH 3 , HCN, HF, HCl in the spacecraft environment. Real time, in-situ monitored, gas concentrations are communicated at 1 Hz through a built-in display on-orbit and additionally through a serial interface on the ground. The instruments function over the typical range of temperatures and pressures required for the spacecraft environment. A ten-year operational life is targeted. Seven AGA instruments are currently deployed on the International Space Station and two Orion-specific units are manifested for Artemis 2. A variation of the operational AGA is under development for lunar Human Landing Systems. A wider calibrated operating pressure envelope is required in this application. Otherwise, the instruments straightforwardly address lessons learned from the original AGA by improving aspects of thermal control, ruggedness, and ease-of-use. A subset of AGA-developed sensed gases (H 2 O, CO 2 , O 2 ) is the subject of the Primary Constituent Monitor (PCM) development for the Habitation and Logistics Outpost (HALO) destined for lunar orbit. Two PCMs will be installed in HALO as part of the environmental control loop where they will interface with vehicle power and communications. While the basic sensor techniques are unchanged from the AGA, these instruments have been radiation hardened to survive for many years in the harsh target environment. Current development status for these instruments will be presented along with recent developments of a naval submarine variant.

Air Monitoring

General Purpose Data-Driven System Monitoring for Space Operations

Modern space propulsion and exploration system designs are becoming increasingly sophisticated and complex. Determining the health state of these systems using traditional methods is becoming more difficult as the number of sensors and component interactions grows. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. The Inductive Monitoring System (IMS) is a data-driven system health monitoring software tool that has been successfully applied to several aerospace applications. IMS uses a data mining technique called clustering to analyze archived system data and characterize normal interactions between parameters. This characterization, or model, of nominal operation is stored in a knowledge base that can be used for real-time system monitoring or for analysis of archived events. Ongoing and developing IMS space operations applications include International Space Station flight control, spacecraft vehicle system health management, launch vehicle ground operations, and fleet supportability. As a common thread of discussion this paper will employ the evolution of the IMS data-driven technique as related to several Integrated Systems Health Management (ISHM) elements. Thematically, the projects listed will be used as case studies. The maturation of IMS via projects where it has been deployed or is currently being integrated to aid in fault detection will be described. The paper will also explain how IMS can be used to complement a suite of other ISHM tools, providing initial fault detection support for diagnosis and recovery

Space Propulsion