Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PrN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

31 records · Page 2

Catalytic Carbodiimide Guanylation by a Nucleophilic, High Spin Iron(II) Imido Complex

Reduction of the three-coordinate iron(III) imido [Ph 2 B( t BuIm) 2 Fe=NDipp] (1) affords [Ph 2 B( t BuIm) 2 Fe=NDipp][K(18-C-6)THF 2 ] (2), a rare example of a high-spin (S = 2) iron(II) imido complex. Unusually for a late metal imido complex, the imido ligand in 2 has nucleophilic character, as demonstrated by the reaction with DippNH 2 , which establishes an equilibrium with the bis(anilido) complex [Ph 2 B( t BuIm) 2 Fe(NHDipp) 2 ][K(18-C-6)THF 2 ] (3). In an unusual transformation, formal insertion of i PrN=C=N i Pr into the Fe=N(imido) bond yields the guanidinate [Ph 2 B( t BuIm) 2 Fe( i PrN) 2 CNDipp][K(18-C-6)THF 2 ] (4). Here, reaction of 4 with excess DippNH 2 provides 3, along with the guanidine ( i PrNH) 2 C=NDipp. As suggested by these stoichiometric reactions, 2 is an efficient catalyst for the guanylation of carbodiimides, converting a wide range of aniline substrates under mild conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generalized Measurable Ignition Criterion for Inertial Confinement Fusion

A multidimensional measurable criterion for central ignition of inertial-confinement-fusion capsules is derived. The criterion accounts for the effects of implosion nonuniformities and depends on three measurable parameters: the neutron-averaged total areal density (pRn^tot), the ion temperature (Tn), and the yield over clean (YOC = ratio of the measured neutron yield to the predicted one-dimensional yield). The YOC measures the implosion uniformity. The criterion can be approximated by chi = (pRn^tot)^0.8 x (Tn/4.7)^1.7 YOC^u > 1 (where pR is in g cm^-2, T in keV, and u ~~0.4–0.5) and can be used to assess the performance of cryogenic implosions on the NIF and OMEGA. Cryogenic implosions on OMEGA have achieved chi ~ 0.02–0.03.

Chang, P Y↗

Two way time transfer results at NRL and USNO

The Naval Research Laboratory (NRL) has developed a two way time transfer modem system for the United States Naval Observatory (USNO). Two modems in conjunction with a pair of Very Small Aperture Terminal (VSAT) and a communication satellite can achieve sub nanosecond time transfer. This performance is demonstrated by the results of testing at and between NRL and USNO. The modems use Code Division Multiple Access (CDMA) methods to separate their signals through a single path in the satellite. Each modem transmitted a different Pseudo Random Noise (PRN) code and received the others PRN code. High precision time transfer is possible with two way methods because of reciprocity of many of the terms of the path and hardware delay between the two modems. The hardware description was given in a previous paper.

Galysh, Ivan J.↗

Assessing the Metal–Metal Interactions in a Series of Heterobimetallic Nb/M Complexes (M = Fe, Co, Ni, Cu) and Their Effect on Multielectron Redox Properties

A one-pot synthetic procedure for a series of bimetallic Nb/M complexes, Cl–Nb( i PrNPPh 2 ) 3 M–X (M = Fe (2), Ni (4), Cu (5)), is introduced. A similar procedure aimed at synthesizing a Nb/Co analogue instead affords i PrN=Nb(iPrNPPh 2 ) 2 (μ-PPh 2 )Co–I (3) through cleavage of one phosphinoamide P–N bond under reducing conditions. Complexes 4 and 5 are found to have short Nb-M distances, corresponding to unusual metal–metal bonds between Nb and these first row transition metals. For comparison, a series of heterobimetallic O≡Nb( i PrNPPh 2 ) 3 M–X complexes (M = Fe (7), Co (8), Ni (9), Cu (10)) was synthesized. In these complexes, the Nb V center is engaged in sufficient π-bonding to the terminal oxo ligand to remove the driving force for direct metal–metal interactions. A comparison of the cyclic voltammograms of 2 and 4–10 shows that the presence of a second metal shifts the redox potentials of both Nb and the late metal center anodically, even when direct metal–metal interactions are not present.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective CO 2 Reduction by Bis(bipyridine)cobalt(II) Catalysts: The Role of Pendant Pyridine as a Proton Acceptor

Electrochemical CO 2 reduction reaction (CO 2 RR) catalyzed by molecular earth-abundant metal catalysts is a promising strategy to convert CO 2 into value-added products. One recent trend in this field has been focusing on the rational design of catalysts by incorporating redox-active ligands and modifying the secondary coordination sphere (SCS) to achieve efficient and selective CO 2 RR. Herein, we report a series of Co bis­(bipyridine) catalysts featuring various dangling groups, such as pyridine, tertiary amine, or butyl, in the secondary coordination sphere (Co-PyMe, Co-Py, Co-PrN, and Co-Bu). Efficient, selective electrocatalytic CO 2 RR was achieved by the complexes after the generation of triply reduced intermediate consisting of a Co I center and a dianionic ligand, producing CO as the major product and trace amount of H 2 . Strong correlations with the identity of dangling groups and turnover frequency (TOF) have been observed, in which Co-PyMe displayed the highest TOF (1086 s –1 in MeCN/H 2 O). Mechanistic studies indicated that the acceleration of CO 2 RR with pyridine-functionalized catalysts were derived from the protonation of pyridine dangling groups which participated as weak acids in the H-bonding network with exogenous proton sources, stabilizing CO 2 -bound intermediates and facilitating proton transfer. In addition, precatalytic CO 2 binding and activation at the third reduction (−2.1 V) was revealed by CV and SEC-IR studies. The resultant doubly reduced CO-bound species acted as a trapping state which inhibited CO 2 RR electrocatalysis. Regeneration of active species was accessed via reductive dissociation of CO at a more negative potential. In conclusion, this study highlights the combined effects of redox-active ligands and pyridine/pyridinium as SCS groups on CO 2 RR catalysis and provides design principles for future development of CO 2 RR catalysts utilizing pyridine/pyridiniums as SCS functional groups to fine-tune the catalytic activity.

CO2 reduction↗

Serial Pixel Analog-to-Digital Converter

This method reduces the data path from the counter to the pixel register of the analog-to-digital converter (ADC) from as many as 10 bits to a single bit. The reduction in data path width is accomplished by using a coded serial data stream similar to a pseudo random number (PRN) generator. The resulting encoded pixel data is then decoded into a standard hexadecimal format before storage. The high-speed serial pixel ADC concept is based on the single-slope integrating pixel ADC architecture. Previous work has described a massively parallel pixel readout of a similar architecture. The serial ADC connection is similar to the state-of-the art method with the exception that the pixel ADC register is a shift register and the data path is a single bit. A state-of-the-art individual-pixel ADC uses a single-slope charge integration converter architecture with integral registers and “one-hot” counters. This implies that parallel data bits are routed among the counter and the individual on-chip pixel ADC registers. The data path bit-width to the pixel is therefore equivalent to the pixel ADC bit resolution.

42 ENGINEERING↗

A passive submicrosecond time dissemination system

A submicrosecond time dissemination system was developed. The system is composed of an experimental transit improvement satellite (TRIAD), TRANET Satellite Tracking System, and special satellite signal receivers each tied to separate cesium clocks. The 400 MHz signal from the satellite is phase modulated plus or minus 45 deg by a pseudo-random noise (PRN) digital code with a bit rate of 5/3 MHz. Evaluation of this system has shown that satellite oscillator frequency instabilities are the major source of error. Experiments indicate that Global time transfers can be made with errors less than 100 nanoseconds.

Taylor, R. J.↗

SLR tracking of GPS-35

An experiment was designed to launch a corner cube retroreflector array on one of the Global Positioning Satellites (GPS). The launch on Aug. 31, 1993 ushered in the era of SLR tracking of GPS spacecraft. Once the space operations group finished the check-out procedures for the new satellite, the agreed upon SLR sites were allowed to track it. The first site to acquire GPS-35 was the Russian system at Maidanak and closely after the MLRS system at McDonald Observatory, Texas. The laser tracking network is currently tracking the GPS spacecraft known as GPS-35 or PRN 5 with great success. From the NASA side there are five stations that contribute data regularly and nearly as many from the international partners. Upcoming modifications to the ground receivers will allow for a further increase in the tracking capabilities of several additional sites and add some desperately needed southern hemisphere tracking. We are analyzing the data and are comparing SLR-derived orbits to those determined on the basis of GPS radiometric data.

Pavlis, Erricos C.↗

MOD: An Organic Detector for the Future Exploration of Mars

The Mars Organic Detector (MOD) is designed to assess whether organic compounds, possibly associated with life, are present in Martian rock and soil samples. MOD has a detection limit that is at least two orders of magnitude more sensitive than the Viking GCMS. MOD is focused on detecting amino acids, amines and PAH (polycyclic aromatic hydrocarbons). Amino acids play an essential role in biochemistry on Earth and PAH are widespread throughout the universe and can provide an indication of the delivery of meteoritic organic material to Mars. The advantage of MOD is the absence of wet chemistry and its simple and robust design. The sample will be extracted from the mineral matrix (0.1 - 1 g of rock-powder) using sublimation and analyzed with a fluorescence detector. The isolation method is based on the fact that amino acids and PAH are volatile at temperatures greater than 150C. The fluorescence detection scheme is based on UV excitation with LED's, optical filters, PrN diode photon detector and a sample calibration reservoir. Fluorescamine is used as a fluorescing reagent for amino acids and amines, while PAH are naturally fluorescent. There is no sample preparation required and the turnaround time for a single analysis is on the order of minutes.

Kminek, G.↗

The GPS Transmit Antenna Phase Center and Its Impact on Precise Geophysical Applications

The ionospheric-free (Lc) phase center of the GPS transmit antenna is modeled as a fixed constant in most geodetic software packages. We estimated a phase center offset for all GPS satellites and found large deviations from the nominal values. In particular, meter level deviation was observed for PRN 13 and somewhat smaller anomalies were observed for PRNs 6, 15, 19 and 31. We will present the estimation results for all GPS satellites and describe the estimation process as well as an error budget. We will present evidence that estimating the phase center offset improves the GPS orbits and discuss the impact of phase center mismodeling on various high-precision applications.

Bar-Sever, Y. E.↗

Real-time software receiver

A real-time software receiver that executes on a general purpose processor. The software receiver includes data acquisition and correlator modules that perform, in place of hardware correlation, baseband mixing and PRN code correlation using bit-wise parallelism.

Ledvina, Brent M.↗

Real-time software receiver

A real-time software receiver that executes on a general purpose processor. The software receiver includes data acquisition and correlator modules that perform, in place of hardware correlation, baseband mixing and PRN code correlation using bit-wise parallelism.

Ledvina, Brent M.↗

Moon-to-Earth: Eavesdropping on the GRAIL Inter-Spacecraft Time-Transfer Link Using a Large Antenna and a Software Receiver

NASA's twin GRAIL [1] spacecraft (Ebb and Flow) arrived at Earth's Moon on New Year's Day, 2012. GRAIL's primary mission is to create a high-resolution map of the Moon's gravitational field by measuring very precisely the change in distance between the two spacecraft [2]. Each spacecraft transmits two signals to the other spacecraft, a PRN code modulated on a 2 GHz carrier (S-band), as well as an unmodulated carrier at roughly 33 GHz (Ka-band). Since it's not feasible to synchronize the two GRAIL spacecraft's clocks via GPS (as was done with GRACE), the S-band signals are used as a time-transfer link to synchronize either Ebb's clock to Flow or vice versa. As an independent measure to determine the clock offset of the GRAIL ultra-stable oscillators to UTC(NIST), an experiment was conducted where our JPL team used a large antenna on Earth to eavesdrop on the inter-spacecraft time-transfer link.

time-transfer subsystem (TTS)↗