Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Powered By”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Examining System-Wide Impacts of Solar PV Control Systems with a Power Hardware-in-the-Loop Platform

High penetration levels of distributed solar PV power generation can lead to adverse power quality impacts such as excessive voltage rise, voltage flicker, and reactive power values that result in unacceptable voltage levels. Advanced inverter control schemes have been proposed that have the potential to mitigate many power quality concerns. However, closed-loop control may lead to unintended behavior in deployed systems as complex interactions can occur between numerous operating devices. In order to enable the study of the performance of advanced control schemes in a detailed distribution system environment, a Hardware-in-the-Loop (HIL) platform has been developed. In the HIL system, GridLAB-D, a distribution system simulation tool, runs in real-time mode at the Pacific Northwest National Laboratory (PNNL) and supplies power system parameters at a point of common coupling to hardware located at the National Renewable Energy Laboratory (NREL). Hardware inverters interact with grid and PV simulators emulating an operational distribution system and power output from the inverters is measured and sent to PNNL to update the real-time distribution system simulation. The platform is described and initial test cases are presented. The platform is used to study the system-wide impacts and the interactions of controls applied to inverters that are integrated into a simulation of the IEEE 8500-node test feeder, with inverters in either constant power factor control or active volt/VAR control. We demonstrate that this HIL platform is well-suited to the study of advanced inverter controls and their impacts on the power quality of a distribution feeder. Additionally, the results from HIL are used to validate GridLAB-D simulations of advanced inverter controls.

14 SOLAR ENERGY↗

Quantitative Power System Resilience Metrics and Evaluation Approach

Power system resilience is an emerging topic and plays an essential role in helping the power industry understand and respond to the increasing threats of extreme weather events. The first step of power system resilience analysis is to introduce metrics to quantify the resilience reasonably. Existing resilience metrics are typically restrained by the limited data for extreme event modeling and fall short in terms of physical interpretation and comparability. This paper develops novel quantitative metrics to evaluate power system resilience in pre- and post-event contexts. The developed metrics illustrate clear physical meanings and can be effectively used to compare resilience across different systems under different extreme events. Moreover, the developed metrics can be applied to both transmission and distribution systems. Simulation on a distribution system is employed to validate the effectiveness of the proposed resilience metrics and resilience evaluation approach.

power system resilience↗

Thermoelectric power factor enhancement with gate-all-around silicon nanowires

The thermoelectric properties of gate-all-around silicon nanowires (Si NWs) are calculated to determine the potential for significant power factor enhancement. The Boltzmann transport equation and relaxation time approximation are employed to develop an electron transport model used to determine the field-effect mobility, electrical conductivity, Seebeck coefficient, and power factor for Si NWs with cross-sectional areas between 4 nm × 4 nm and 12 nm × 12 nm and a range of gate biases. Electrical conductivity for the gated Si NWs was much higher than that of doped Si due to the lack of ionized impurities and correspondingly greater carrier mobility. A significant increase in electrical conductivity with decreasing Si NW cross-sectional area was also observed due to a large increase in the average carrier density. For all Si NWs, the Seebeck coefficient was lower than that of doped bulk Si due to the different energy dependence between ionized impurity and phonon-mediated scattering processes. This decrease was also confirmed with Seebeck coefficient measurements of multigated Si NWs and n-type Si thin-films. Quantum confinement was also found to increase the Seebeck coefficient for <8 nm × 8 nm Si NWs and also at high charge densities. A maximum power factor of 6.8 × 10{sup −3} W m{sup −1} K{sup −2} was calculated for the 6 nm × 6 nm Si NWs with typical Si/SiO{sub 2} interface roughness, which is 2–3 × those obtained experimentally for bulk Si. The power factor was also found to greatly depend on surface roughness, with a root-mean-square roughness of <0.8 nm necessary for power factor enhancement. An increase in ZT may also be possible if a low thermal conductivity can be obtained with minimal surface roughness.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessment of the Time a Power System Remains in the Power Deficit Zone as a Function of the Scale Factor for Wind-Power Plants

The scale factor for the use of power plants of a certain type refers to the fraction of their use in the overall energy balance of the system. Energy production by wind power plants depends directly on the wind conditions in a particular location and is stochastic in character. Increasing the fraction of these installations in the overall balance of a system also requires an increase in the power reserve capacity. Here the time a power system remains in the power deficit zone is estimated as a function of the fraction of wind power plants in the system structure. Two approaches to the placement of wind power units within a power system are compared– individual components and a system of a set of components. It is concluded that even within a small power system, combining geographically distributed components with favorable and unfavorable wind conditions into a system can have a positive effect on all the components within certain ranges of the scale factor.

17 WIND ENERGY↗

Thermal Management and Reliability of Power Electronics and Electric Machines

Increasing the number of electric-drive vehicles (EDVs) on America's roads has been identified as a strategy with near-term potential for dramatically decreasing the nation's dependence on oil - by the U.S. Department of Energy, the federal cross-agency EV-Everywhere Challenge, and the automotive industry. Mass-market deployment will rely on meeting aggressive technical targets, including improved efficiency and reduced size, weight, and cost. Many of these advances will depend on optimization of thermal management. Effective thermal management is critical to improving the performance and ensuring the reliability of EDVs. Efficient heat removal makes higher power densities and lower operating temperatures possible, and in turn enables cost and size reductions. The National Renewable Energy Laboratory (NREL), along with DOE and industry partners is working to develop cost-effective thermal management solutions to increase device and component power densities. In this presentation, the activities in recent years related to thermal management and reliability of automotive power electronics and electric machines are presented.

30 DIRECT ENERGY CONVERSION↗

Datasheet Driven Silicon Carbide Power MOSFET Model

A compact model for SiC Power MOSFETs is presented. The model features a physical description of the channel current and internal capacitances and has been validated for dc, CV, and switching characteristics with measured data from a 1200-V, 20-A SiC power MOSFET in a temperature range of 25 degrees C to 225 degrees C. The peculiar variation of on-state resistance with temperature for SiC power MOSFETs has also been demonstrated through measurements and accounted for in the developed model. In order to improve the user experience with the model, a new datasheet driven parameter extraction strategy has been presented which requires only data available in device datasheets, to enable quick parameter extraction for off-the-shelf devices. Excellent agreement is shown between measurement and simulation using the presented model over the entire temperature range.

Mudholkar, M↗

Preventive Power Outage Estimation Based on a Novel Scenario Clustering Strategy

The increasing occurrence of extreme weather events is challenging power grid operation. For extreme weather events, the system operator is responsible for estimating the power outages and scheduling the restoration resources. This paper proposes an outage evaluation framework to identify the possible unserved load profiles, vulnerable areas, and mobile energy adequacy. The outputs of an outage prediction model tool are used to generate numerous faulted line scenarios. Next, each scenario's nodal unserved load profile is obtained by solving a three-phase restoration model that considers repair crews and mobile energy resources (MERs). Then, a novel scenario clustering strategy is developed to cluster the unserved load profiles into multiple representative profiles which the system operator can focus on. Finally, case studies on a distribution system evaluate the damage caused by an extreme weather event and verify the effectiveness of the proposed scenario clustering strategy.

MATHEMATICS AND COMPUTING,POWER TRANSMISSION AND D↗

Efficiency, Power Loss, and Power Factor Measurement of Quadrupole Magnet Power Supplies at the Spallation Neutron Source

The linear accelerator (LINAC) quadrupole magnets are powered by 42 silicon-controlled rectifier (SCR) based power supplies at the Spallation Neutron Source (SNS) facility of Oak Ridge National Laboratory. These 35V, 525A power supplies are bulky, inefficient and require both air and water cooling. The reliability of the SNS facility is impacted due to water leaks internal to power supplies and current readback issues associated with their unique control system interface, resulting in multiple downtime events. Hence, an alternate solution is necessary for the continued reliable operation of the SNS. To mitigate the above-mentioned problems, this paper proposes the use of off-the-shelf Switch Mode Power Supplies (SMPS) rated for 20V, 500A with serial control interface. These SMPS are air-cooled, more efficient and more compact owing to their switching speeds of approximately 160 kHz. The performance enhancements of the SMPS in comparison with the existing SCR power supply are discussed in detail in this paper. The features of the SMPS, along with experimental results for both power supplies, like efficiency, power losses and stability, are presented. Ongoing work is also discussed.

Harave, Sudarshan↗

Hybridizing a geothermal power plant with concentrating solar power and thermal storage to increase power generation and dispatchability

Geothermal power plants often deploy less than their full power capacity due to declining geothermal resources. Integrating heat from a concentrating solar power (CSP) collector field increases the power output at low cost. This article considers five methods of solar heat addition in a double-flash geothermal plant. The most promising solution converts solar heat into electrical work with an efficiency of 24.3%. The economic feasibility and optimal sizing of the solar field and thermal stores are evaluated. A hybrid plant that increases power generation from 22 to 24 MWe has a Levelized Cost of Electricity (LCOE) of 0.07 +/- 0.01 $/kWhe. Adding three hours of storage increases the LCOE to 0.08 +/- 0.01 $/kWhe. Photovoltaic systems are considered to be a low-cost renewable technology, but an equivalent photovoltaic system with battery storage costs 0.15 +/- 0.07 $/kWhe due to the high cost and replacement rate of batteries compared to thermal storage. The hybrid plant also has a lower LCOE than a conventional CSP plant. If the dispatchability that thermal storage provides is rewarded with higher electricity prices, calculations indicate storage becomes an attractive investment when discharged power receives 1.75 times the typical price of electricity.

15 GEOTHERMAL ENERGY↗

Intercell Power Transformer for Power Balancing of Polyphase Wireless Power Transfer Systems

Polyphase wireless power transfer (PWPT) systems experience receiver side imbalances in misaligned conditions. This paper proposes a method for power balancing in PWPT systems, specifically addressing the challenges caused by receivers coil unequal coupling. An intercell power transformer (IPT) is introduced at the receiver side to mitigate the effects of coil mismatch. Simulations of the PWPT system incorporating IPT demonstrate its effectiveness in enhancing power distribution. For voltage-fed rectifiers (VFR), the IPT increases the conduction angle, resulting in higher output power. In current- fed rectifiers (CFR), the IPT promotes uniform power sharing among rectifiers, thereby reducing electrical stress on semiconductor devices and passive components. Simulation results indicate that, under coil misalignment, the IPT improves output power by approximately 49% for VFRs and 44% for CFRs compared to conventional PWPT systems without IPT.

Wojda, Rafal [ORNL] (ORCID:0000000286609268)↗

Capacity value assessments of wind power

This article describes some of the recent research into the capacity value of wind power. With the worldwide increase in wind power during the past several years, there is increasing interest and significance regarding its capacity value because this has a direct influence on the amount of other (nonwind) capacity that is needed. We build on previous reviews from IEEE and IEA W ind T ask 25 a and examine recent work that evaluates the impact of multiple‐year data sets and the impact of interconnected systems on resource adequacy. We also provide examples that explore the use of alternative reliability metrics for wind capacity value calculations. We show how multiple‐year data sets significantly increase the robustness of results compared to single‐year assessments. Assumptions regarding the transmission interconnections play a significant role. To date, results regarding which reliability metric to use for probabilistic capacity valuation show little sensitivity to the metric. WIREs Energy Environ 2017, 6:e226. doi: 10.1002/wene.226 This article is categorized under: Wind Power > Economics and Policy Wind Power > Systems and Infrastructure Energy Infrastructure > Economics and Policy

Milligan, Michael↗

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems

With increased attention on grid-forming inverters as a power system stabilizing device during high shares of inverter-based resource operations, there is a present need for a transparent and methodical investigation of the inverted and direct power to frequency control capabilities and impacts of these devices on emerging power systems. Here, analysis of the frequency dynamics of the droop-controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, nonlinear frequency control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed dc-side system has a negligible impact on power transfer and will not impede frequency regulation, and confirm the primary frequency response improvement with nonlinear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in larger networks. Oscillatory mode analysis confirms the grid-forming benefit of increased damping; decreased damping is observed at shares above 80%, but not at 100%. Finally, simulations on a validated Maui power system model with a 96% of inverter-based resources model yield a trend toward a first-order response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A 4H Silicon Carbide Gate Buffer for Integrated Power Systems

A gate buffer fabricated in a 2-mu m 4H silicon carbide (SiC) process is presented. The circuit is composed of an input buffer stage with a push-pull output stage, and is fabricated using enhancement mode N-channel FETs in a process optimized for SiC power switching devices. Simulation and measurement results of the fabricated gate buffer are presented and compared for operation at various voltage supply levels, with a capacitive load of 2 nF. Details of the design including layout specifics, simulation results, and directions for future improvement of this buffer are presented. In addition, plans for its incorporation into an isolated high-side/low-side gate-driver architecture, fully integrated with power switching devices in a SiC process, are briefly discussed. This letter represents the first reported MOSFET-based gate buffer fabricated in 4H SiC.

Ericson, N↗

Phase diagram of power law and Lennard-Jones systems: Crystal phases

An extensive characterization of the low temperature phase diagram of particles interacting with power law or Lennard-Jones potentials is provided from Lattice Dynamical Theory. For power law systems, only two lattice structures are stable for certain values of the exponent (or softness) (A15, body centered cube (bcc)) and two more (face centered cubic (fcc), hexagonal close packed (hcp)) are always stable. Among them, only the fcc and bcc are equilibrium states. For Lennard-Jones systems, the equilibrium states are either hcp or fcc, with a coexistence curve in pressure and temperature that shows reentrant behavior. The hcp solid never coexists with the liquid. In all cases analyzed, for both power law and Lennard-Jones potentials, the fcc crystal has higher entropy than the hcp. The role of anharmonic terms is thoroughly analyzed and a general thermodynamic integration to account for them is proposed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗