Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pool boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Design and test of a compact optics system for the pool boiling experiment

The experiment described seeks to improve the understanding of the fundamental mechanisms that constitute nucleate pool boiling. The vehicle for accomplishing this is an investigation, including tests to be conducted in microgravity and coupled with appropriate analyses, of the heat transfer and vapor bubble dynamics associated with nucleation, bubble growth/collapse and subsequent motion, considering the interrelations between buoyancy, momentum and surface tension which will govern the motion of the vapor and surrounding liquid, as a function of the heating rate at the heat transfer surface and the temperature level and distribution in the bulk liquid. The experiment is designed to be contained within the confines of a Get-Away-Special Canister (GAS Can) installed in the bay of the space shuttle. When the shuttle reaches orbit, the experiment will be turned on and testing will proceed automatically. In the proposed Pool Boiling Experiment a pool of liquid, initially at a precisely defined pressure and temperature, will be subjected to a step imposed heat flux from a semitransparent thin-film heater forming part of one wall of the container such that boiling is initiated and maintained for a defined period of time at a constant pressure level. Transient measurements of the heater surface and fluid temperatures near the surface will be made, noting especially the conditions at the onset of boiling, along with motion photography of the boiling process in two simultaneous views, from beneath the heating surface and from the side. The conduct of the experiment and the data acquisition will be completely automated and self-contained. For the initial flight, a total of nine tests are proposed, with three levels of heat flux and three levels of subcooling. The design process used in the development and check-out of the compact photographic/optics system for the Pool Boiling Experiment is documented.

Ling, Jerri S.↗

A New Theory of Nucleate Pool Boiling in Arbitrary Gravity

Heat transfer rates specific to nucleate pool boiling under various conditions are determined by the dynamics of vapour bubbles that are originated and grow at nucleation sites of a superheated surface. A new dynamic theory of these bubbles has been recently developed on the basis of the thermodynamics of irreversible processes. In contrast to other existing models based on empirically postulated equations for bubble growth and motion, this theory does not contain unwarrantable assumptions, and both the equations are rigorously derived within the framework of a unified approach. The conclusions of the theory are drastically different from those of the conventional models. The bubbles are shown to detach themselves under combined action of buoyancy and a surface tension force that is proven to add to buoyancy in bubble detachment, but not the other way round as is commonly presumed. The theory ensures a sound understanding of a number of so far unexplained phenomena, such as effect caused by gravity level and surface tension on the bubble growth rate and dependence of the bubble characteristics at detachment on the liquid thermophysical parameters and relevant temperature differences. The theoretical predictions are shown to be in a satisfactory qualitative and quantitative agreement with observations. When being applied to heat transfer at nucleate pool boiling, this bubble dynamic theory offers an opportunity to considerably improve the main formulae that are generally used to correlate experimental findings and to design boiling heat removal in various industrial applications. Moreover, the theory makes possible to pose and study a great deal of new problems of essential impact in practice. Two such problems are considered in detail. One problem concerns the development of a principally novel physical model for the first crisis of boiling. This model allows for evaluating critical boiling heat fluxes under various conditions, and in particular at different gravity levels, with a good agreement with experimental evidence. The other problem bears upon equilibrium shapes of a detached bubble near a heated surface in exceedingly low gravity. In low gravity or in weightlessness, the bubble can remain in the close vicinity of the surface for a long time, and its shape is greatly affected by the Marangoni effect due to both temperature and possible surfactant concentration being nonuniform along the interface. The bubble performs at these conditions like a heat pipe, with evaporation at the bubble lower boundary and condensation at its upper boundary, and ultimately ensures a substantial increase in heat removal as compared with that in normal gravity. Some other problems relevant to nucleate pool and forced convection boiling heat transfer are also discussed.

Buyevich, Y. A.↗

Electrical design of payload G-534: The Pool Boiling Experiment

Payload G-534, the Pool Boiling Experiment (PBE), is a Get Away Special that is scheduled to fly on the shuttle in 1992. This paper will give a brief overall description of the experiment with the main discussion being the electrical design with a detailed description of the power system and interface to the GAS electronics. The batteries used and their interface to the experiment Power Control Unit (PCU) and GAS electronics will be examined. The design philosophy for the PCU will be discussed in detail. The criteria for selection of fuses, relays, power semiconductors and other electrical components along with grounding and shielding policy for the entire experiment will be presented. The intent of this paper is to discuss the use of military tested parts and basic design guidelines to build a quality experiment for minimal additional cost.

Francisco, David R.↗

Electrical design of Space Shuttle payload G-534: The pool boiling experiment

Payload G-534, the Pool Boiling Experiment (PBE), is a Get Away Special (GAS) payload that flew on the Space Shuttle Spacelab Mission J (STS 47) on September 19-21, 1992. This paper will give a brief overall description of the experiment with the main discussion being the electrical design with a detailed description of the power system and interface to the GAS electronics. The batteries used and their interface to the experiment Power Control Unit (PCU) and GAS electronics will be examined. The design philosophy for the PCU will be discussed in detail. The criteria for selection of fuses, relays, power semiconductors, and other electrical components along with grounding and shielding policy for the entire experiment are presented. The intent of this paper is to discuss the use of military tested parts and basic design guidelines to build a quality experiment for minimal additional cost.

Francisco, David R.↗

Enhanced pool boiling heat transfer with metal foam tubes in inline tube bundle configuration

Flooded evaporators, commonly known as shell-and-tube heat exchangers, are widely used in large-scale industrial refrigeration and air-conditioning systems due to their high pool boiling heat transfer efficiency. However, their bulky configuration requires a large refrigerant inventory, which poses safety challenges—particularly when employing next-generation A2L refrigerants that are mildly flammable. Here, to address this issue, the development of compact heat exchangers with enhanced heat transfer performance is essential. In this study, a novel metal foam tube design is proposed to augment pool boiling heat transfer. Experiments were conducted at a saturation temperature of 20 °C and across a heat flux range of 7–60 kW m −2 . The tests were conducted for both smooth and metal foam tubes with an inline tube bundle configuration and for a pitch–to–diameter (P/D) ratios of 1.3 and 1.5. Pool boiling performance was evaluated for next-generation hydrofluoroolefin (HFO) refrigerants, R1234yf and R1234ze(E), with R134a serving as the baseline fluid. The results indicate that the heat transfer coefficient (HTC) of R1234yf is comparable to R134a, while R1234ze(E) shows slightly lower performance. Importantly, the metal foam tubes achieved up to a 217% enhancement in HTC compared to smooth tubes.

Metal foam tubes↗

Alteration of pool boiling heat transfer on metallic surfaces by in situ oxidation

The critical heat flux during pool boiling has been investigated for a range of applications including electrical power generation and thermal management. Reported experimental CHF values during pool boiling of water on flat metallic surfaces, however, show a large discrepancy across studies. Here, we address this discrepancy in CHF values by accounting for oxidation of metallic surfaces during boiling. We studied the effect of in situ oxidation on flat Cu and Ni surfaces by changing the duration that samples were held in saturated water before conducting boiling experiments. The morphology and chemical composition of surfaces after the boiling experiments were analyzed by atomic force microscopy and X-ray photoelectron spectroscopy, respectively. Cu surfaces showed gradually increasing CHF values as the duration in saturated water increased, which could be attributed to the increase in roughness due to the formation of Cu 2 O nanostructures. Conversely, Ni surfaces showed relatively stable CHF and morphology as a nearly flat layer of NiO formed, with one exception: formation of a highly wetting hydroxide, Ni(OH) 2 , on a Ni coupon held in saturated water for 24 h resulted in a uniquely high CHF value, signifying the importance of surface chemistry in addition to morphology. Finally, the fundamental mechanisms resulting in the wide spread of CHF values on metallic surfaces elucidated in this work will lead to more accurate estimation of CHF as well as a deeper mechanistic understanding of CHF values on engineered surfaces.

42 ENGINEERING↗

Gravity and Heater Size Effects on Pool Boiling Heat Transfer

The current work is based on observations of boiling heat transfer over a continuous range of gravity levels between 0g to 1.8g and varying heater sizes with a fluorinert as the test liquid (FC-72/n-perfluorohexane). Variable gravity pool boiling heat transfer measurements over a wide range of gravity levels were made during parabolic flight campaigns as well as onboard the International Space Station. For large heaters and-or higher gravity conditions, buoyancy dominated boiling and heat transfer results were heater size independent. The power law coefficient for gravity in the heat transfer equation was found to be a function of wall temperature under these conditions. Under low gravity conditions and-or for smaller heaters, surface tension forces dominated and heat transfer results were heater size dependent. A pool boiling regime map differentiating buoyancy and surface tension dominated regimes was developed along with a unified framework that allowed for scaling of pool boiling over a wide range of gravity levels and heater sizes. The scaling laws developed in this study are expected to allow performance quantification of phase change based technologies under variable gravity environments eventually leading to their implementation in space based applications.

Boiling↗

Heat transfer and visual observation of pool boiling of next-generation low-pressure refrigerant: R1336mzz(Z)

R1336mzz(Z) is a non-flammable and non-toxic hydrofluoroolefin (HFO), which is a potential alternative working fluid for multiple applications such as centrifugal chillers, industrial high temperature heat pumps, and Organic Rankine Cycles. Pool boiling is one of the primary heat transfer modes in shell-and-tube evaporators, and there is limited data for R1336mzz(Z) due to its recent introduction. This study investigated the pool boiling characteristics of R1336mzz(Z) using a closed-loop apparatus. Heat transfer coefficients on a smooth aluminum surface were measured at various heat fluxes with a heating block, and the results were compared to predictions from various correlations. Additionally, a high-speed camera was employed to visualize and analyze the pool boiling behavior of this next-generation low-pressure refrigerant.

Yang, Cheng-Min [ORNL]↗

Effects of vibration on pool boiling.

Sinusoidal surface vibration effect on nucleate pool boiling reveals lowered surface temperature for low heat flux, LF and high acceleration

HEAT-TRANSFER COEFFICIENT↗

Combined roles of buoyancy and orientation in nucleate pool boiling

The paper presents results obtained during pool boiling from flat surfaces over body force levels of a/g = -1 to 0 to 20 for LN2 and R-113 under steady and transient conditions. Pyrex and metal surfaces are used. Particular attention is given to the case where the effective gravity is perpendicular to the heating surface. At the lower levels of heat flux with nucleate boiling, the heater surface superheat first increases and then decreases as the body force increases above a/g = 1. This is due to the greater contribution of nonboiling convection.

Merte, H., Jr.↗

Environmental qualification testing of payload G-534, the Pool Boiling Experiment

Payload G-534, the prototype Pool Boiling Experiment (PBE), is scheduled to fly on the STS-47 mission in September 1992. This paper describes the purpose of the experiment and the environmental qualification testing program that was used to prove the integrity of the hardware. Component and box level vibration and thermal cycling tests were performed to give an early level of confidence in the hardware designs. At the system level, vibration, thermal extreme soaks, and thermal vacuum cycling tests were performed to qualify the complete design for the expected shuttle environment. The system level vibration testing included three axis sine sweeps and random inputs. The system level hot and cold soak tests demonstrated the hardware's capability to operate over a wide range of temperatures and gave wider latitude in determining which shuttle thermal attitudes were compatible with the experiment. The system level thermal vacuum cycling tests demonstrated the hardware's capability to operate in a convection free environment. A unique environmental chamber was designed and fabricated by the PBE team and allowed most of the environmental testing to be performed within the hardware build laboratory. The completion of the test program gave the project team high confidence in the hardware's ability to function as designed during flight.

Sexton, J. Andrew↗

Electrohydrodynamic Pool Boiling in Reduced Gravity

This research is concerned with studying the effects of applied electric fields on pool boiling in a reduced-gravity environment. Experiments are conducted at the NASA Lewis 2.2 sec Drop tower using a drop rig constructed at UC Davis. In the experiments, a platinum wire is heated while immersed in saturated liquid refrigerants (FC-72 and FC-87), or water, causing vapor formation at the wire surface. Electric fields are applied between the wire surface and an outer screen electrode that surrounds the wire. Preliminary normal-gravity experiments with water have demonstrated that applied electric fields generated by the rig electronics can influence boiling characteristics. Reduced-gravity experiments will be performed in the summer of 1996. The experiments will provide fundamental data on electric field strengths required to disrupt film boiling (for various wire heat generation input rates) in reduced gravity for a cylindrical geometry. The experiments should also shed light on the roles of characteristic bubble generation times and charge relaxation times in determining the effects of electric fields on pool boiling. Normal-gravity comparison experiments will also be performed.

Shaw, Benjamin D.↗

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

Nucleate pool boiling in the long duration low gravity environment of the Space Shuttle

The results are presented of an experimental study of nucleate pool boiling performed in the low gravity environment of the space shuttle. Photographic observations of pool boiling in Freon 113 were obtained during the 'Tank Pressure Control Experiment,' flown on the Space Transportation System, STS-43 in August 1991. Nucleate boiling data from large (relative to bubble size) flat heating surfaces (0.1046 by 0.0742 m) was obtained at very low heat fluxes (0.22 to 1.19 kW/sq m). The system pressure and the bulk liquid subcooling varied in the range of 40 to 60 kPa and 3 to 5 C respectively. Thirty-eight boiling tests, each of 10-min duration for a given heat flux, were conducted. Measurements included the heater power, heater surface temperature, the liquid temperature and the system pressure as functions of heating time. Video data of the first 2 min of heating was recorded for each test. In some tests the video clearly shows the inception of boiling and the growth and departure of bubbles from the surface during the first 2 min of heating. In the absence of video data, the heater temperature variation during heating shows the inception of boiling and stable nucleate boiling. During the stable nucleate boiling, the wall superheat varied between 2.8 to 3.8 C for heat fluxes in the range of 0.95 to 1.19 kW/sq m. The wall superheat at the inception of boiling varied between 2 to 13 C.

Hasan, M. M.↗

Nucleate pool boiling in the long duration low gravity environment of the space shuttle

The results are presented of an experimental study of nucleate pool boiling performed in the low gravity environment of the space shuttle. Photographic observations of pool boiling in Freon 113 were obtained during the 'Tank Pressure Control Experiment', flown on the Space Transportation System STS-43 in August 1991. Nucleate boiling data from large (relative to bubble size) flat heating surfaces (0.1046 by 0.0742 m) was obtained at very low heat fluxes (0.22 to 1.19 kw/so m). The system pressure and the bulk liquid subcooling varied in the range of 40 to 60 kPa and 3 to 5 C respectively. Thirty-eight boiling tests, each of 10 min duration for a given heat flux, were conducted. Measurements included the heater power, heater surface temperature, the liquid temperature and the system pressure as functions of heating time. Video data of the first 2 min of heating was recorded for each test. In some tests the video clearly shows the inception of boiling and the growth and departure of bubbles from the surface during the first 2 min of heating. In the absence of video data, the heater temperature variation during heating shows the inception of boiling and stable nucleate boiling. During the stable nucleate boiling, the wall superheat varied between 2.8 to 3.8 C for heat fluxes in the range of 0.95 to 1.19 kw/so m. The wall superheat at the inception of boiling varied between 2 to 13 C.

Hasan, M. M.↗