Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Polymer phase”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

PVDF-based backsheet cracking: Mapping in situ phase evolution by X-ray scattering

One of the most common polymers used in commercial photovoltaic backsheets is polyvinylidene fluoride (PVDF). However, recent reports have shown the potential for PVDF-based backsheets to crack and fail prematurely. Previous work has suggested that polymer phase changes play a role in the failure mechanism. Here, in situ wide-angle X-ray scattering maps are used to show that α- to β-phase transformations occur at crack tips in aged PVDF-based backsheets under stretching. Substantial β-phase formation is shown to be associated with strain hardening. In addition, our work demonstrates that β-phase formation is not required for crack growth and only occurs at crack tips when plastic deformation of the PVDF polymer has occurred. In conclusion, the anisotropy in the strength of aged PVDF-based backsheets is linked to the lack of β-phase formation when strain is applied to aged backsheets in the transverse direction.

14 SOLAR ENERGY

Multiscale Modeling of PEEK Using Reactive Molecular Dynamics Modeling and Micromechanics

Polyether ether ketone (PEEK) is a high-performance, semi-crystalline thermoplastic that is used in a wide range of engineering applications, including some structural components of aircraft. The design of new PEEK-based materials requires a precise understanding of the multiscale structure and behavior of semi-crystalline PEEK. Molecular Dynamics (MD) modeling can efficiently predict bulk-level properties of single phase polymers, and micromechanics can be used to homogenize those phases based on the overall polymer microstructure. In this study, MD modeling was used to predict the mechanical properties of the amorphous and crystalline phases of PEEK. The hierarchical microstructure of PEEK, which combines the aforementioned phases, was modeled using a multiscale modeling approach facilitated by NASA's MSGMC. The bulk mechanical properties of semi-crystalline PEEK predicted using MD modeling and MSGMC agree well with vendor data, thus validating the multiscale modeling approach.

Pisani, William A.

Effect of Polymer Electrode Morphology on Performance of a Lithium/Polypyrrole Battery

A variety of conducting polymer batteries were described in the recent literature. In this work, a Li/Polypyrrole secondary battery is described. The effect of controlling the morphology of the polymer on enhancement of counterion diffusion in the polymer phase is explored. A method of preparing conducting polymers was developed which yields high surface area per unit volume of electrode material. A porous membrane is used as a template in which to electrochemically polymerize pyrrole, then the membrane is dissolved, leaving the polymer in a fibrillar form. Conventionally, the polymer is electrochemically polymerized as a dense polymer film on a smooth Pt disk electrode. Previous work has shown that when the polymer is electrochemically polymerized in fribrillar form, charge transport rates are faster and charge capacities are greater than for dense, conventionally grown films containing the same amount of polymer. The purpose is to expand previous work by further investigating the possibilities of the optimization of transport rates in polypyrrole films by controlling the morphology of the films. The utility of fibrillar polypyrrole as a cathode material in a lithium/polymer secondary battery is then assessed. The performance of the fibrillar battery is compared to the performance of an analogous battery which employed a conventionally grown polypyrrole film. The study includes a comparison of cyclic voltammetry, shape of charge/discharge curves, discharge time and voltage, cycle life, coulombic efficiencies, charge capacities, energy densities, and energy efficiencies.

Nicholson, Marjorie Anne

Confinement-induced chirality in phase-separated achiral polymer solutions

Self-organization of polymers in constrained geometries largely determines their applications in high-strength materials, photonics, and electronics. Chiral organization under confinement is well established for polymers with intrinsic molecular chirality; however, it has not been observed for achiral polymers. Here, we report the emergence of chirality in spatially confined solutions of achiral rigid-rod polymers. We show that kinetically arrested phase separation of polymer solutions confined to narrow capillaries resulted in alternating segments of isotropic and chiral nematic phases. The chiral structure of the nematic segments originated from the interplay between the constrained geometry, surface anchoring, orientational wetting, and elastic anisotropy of rigid-rod polymers. The catenoidal shape of the chiral structure recapitulated the morphology of biological chiral structures. These findings provide insight into the organization of soft matter under spatial confinement and offer a straightforward way to form chiral structures from achiral synthetic polymers.

Science & Technology - Other Topics

Phase partitioning in space and on earth

The influence of gravity on the efficiency and quality of the impressive separations achievable by bioparticle partitioning is investigated by demixing polymer phase systems in microgravity. The study involves the neutral polymers dextran and polyethylene glycol, which form a two-phase system in aqueous solution at low concentrations. It is found that demixing in low-gravity occurs primarily by coalescence, whereas on earth the demixing occurs because of density differences between the phases.

Van Alstine, James M.

Demixing of aqueous polymer two-phase systems in low gravity

When polymers such as dextran and poly(ethylene glycol) are mixed in aqueous solution biphasic systems often form. On Earth the emulsion formed by mixing the phases rapidly demixes because of phase density differences. Biological materials can be purified by selective partitioning between the phases. In the case of cells and other particulates the efficiency of these separations appears to be somewhat compromised by the demixing process. To modify this process and to evaluate the potential of two-phase partitioning in space, experiments on the effects of gravity on phase emulsion demixing were undertaken. The behavior of phase systems with essentially identical phase densities was studied at one-g and during low-g parabolic aircraft maneuvers. The results indicate the demixing can occur rather rapidly in space, although more slowly than on Earth. The demixing process was examined from a theoretical standpoint by applying the theory of Ostwald ripening. This theory predicts demizing rates many orders of magnitude lower than observed. Other possible demixing mechanisms are considered.

Bamberger, S.

Countercurrent distribution of biological cells

It is known that the addition of phosphate buffer to two polymer aqueous phase systems has a strong effect on the partition behavior of cells and other particles in such mixtures. The addition of sodium phosphate to aqueous poly(ethylene glycol) dextran phase systems causes a concentration-dependent shift in binodial on the phase diagram, progressively lowering the critical conditions for phase separation as the phosphate concentration is increased. Sodium chloride produces no significant shift in the critical point relative to the salt-free case. Accurate determinations of the phase diagram require measurements of the density of the phases; data is presented which allows this parameter to be calculated from polarimetric measurements of the dextran concentrations of both phases. Increasing polymer concentrations in the phase systems produce increasing preference of the phosphate for the dextran-rich bottom phase. Equilibrium dialysis experiments showed that poly(ethylene glycol) effectively rejected phosphate, and to a lesser extent chloride, but that dextran had little effect on the distribution of either salt. Increasing ionic strength via addition of 0.15 M NaCl to phase systems containing 0.01 M phosphate produces an increased concentration of phosphate ions in the bottom dextran-rich phase, the expected effect in this type of Donnan distribution.

Source record

Design of multisample, multistep phase partitioning apparatus for use on Space Shuttle Spacelab, and Spacelab missions

Traditional separation techniques are inadequate for many new bioprocessing challenges. Innovative separation methods such as aqueous two phase partitioning are needed to perpetuate bioprocess commercialization. Aqueous two phase polymer partitioning systems provide a process for separating biological materials when combined with microgravity. An innovative space qualified apparatus developed for carrying out separations by partitioning in immiscible polymer systems under mirogravity conditions is described. The apparatus offers an innovative approach to low gravity bioseparations in general and phase partitioning in particular. These capabilities support NASA's interest in serving the biotechnology research community and providing quantitative data in the gravity dependent components of separation processes.

Deuser, Mark S.

Hardware for studying the demixing of aqueous polymer two-phase systems in low gravity

The gravity-free demixing behavior of aqueous polymer two-phase systems (APTPS) has been studied on Earth, and onboard KC-135 aircraft and the Space Shuttle. Results suggest a good correlation between the demixing behavior of isopycnic systems on Earth and the low g behavior of systems exhibiting phase density differences. The short term (20 s) behavior of APTPS onboard KC-135 aircraft has been shown to mimic their initial demixing behavior in space. It appears that the few minutes of low g provided by parabolic rocket flight will be sufficient to study all but the later stages of demixing of APTPS. We are therefore turning our attention toward the design and use of hardware for studying the demixing of APTPS onboard sounding rockets. This seminar will discuss the evolution of hardware and research from hand-held KC-135 and Shuttle hardware through to automated hardware designed for utilization of KC-135, sounding rocket, and Space Shuttle Mid-deck Locker flight opportunities.

Vanalstine, J. M.

Tool for Generation of MAC/GMC Representative Unit Cell for CMC/PMC Analysis

This document describes a recently developed analysis tool that enhances the resident capabilities of the Micromechanics Analysis Code with the Generalized Method of Cells (MAC/GMC) 4.0. This tool is especially useful in analyzing ceramic matrix composites (CMCs), where higher fidelity with improved accuracy of local response is needed. The tool, however, can be used for analyzing polymer matrix composites (PMCs) as well. MAC/GMC 4.0 is a composite material and laminate analysis software developed at NASA Glenn Research Center. The software package has been built around the concept of the generalized method of cells (GMC). The computer code is developed with a user friendly framework, along with a library of local inelastic, damage, and failure models. Further, application of simulated thermomechanical loading, generation of output results, and selection of architectures to represent the composite material have been automated to increase the user friendliness, as well as to make it more robust in terms of input preparation and code execution. Finally, classical lamination theory has been implemented within the software, wherein GMC is used to model the composite material response of each ply. Thus, the full range of GMC composite material capabilities is available for analysis of arbitrary laminate configurations as well. The primary focus of the current effort is to provide a graphical user interface (GUI) capability that generates a number of different user-defined repeating unit cells (RUCs). In addition, the code has provisions for generation of a MAC/GMC-compatible input text file that can be merged with any MAC/GMC input file tailored to analyze composite materials. Although the primary intention was to address the three different constituents and phases that are usually present in CMCs-namely, fibers, matrix, and interphase-it can be easily modified to address two-phase polymer matrix composite (PMC) materials where an interphase is absent. Currently, the tool capability includes generation of RUCs for square packing, hexagonal packing, and random fiber packing as well as RUCs based on actual composite micrographs. All these options have the fibers modeled as having a circular cross-sectional area. In addition, a simplified version of RUC is provided where the fibers are treated as having a square cross section and are distributed randomly. This RUC facilitates a speedy analysis using the higher fidelity version of GMC known as HFGMC. The first four mentioned options above support uniform subcell discretization. The last one has variable subcell sizes due to the primary intention of keeping the RUC size to a minimum to gain the speed ups using the higher fidelity version of MAC. The code is implemented within the MATLAB (The Mathworks, Inc., Natick, MA) developmental framework; however, a standalone application that does not need a priori MATLAB installation is also created with the aid of the MATLAB compiler.

Materials Engineering

Multiphasic droplet microfluidics platform for controlled bacteria and mammalian cell co-culture

Microfluidics has revolutionized high-throughput miniaturized biological assays. However, co-culture of mammalian cells and bacteria remains challenging in microfluidic systems due to incompatible growth requirements, limited spatial control, and the requirement for a mammalian cell adhesion matrix. Here, we present a microfluidic platform that generates multiphasic droplets which encapsulate mammalian and bacterial cells, enabling their direct and indirect co-culture. By combining photopolymerizable hydrogels with polymer phase separation, we generate core–shell droplets composed of a liquid and a hydrogel compartment. The hydrogel compartment supports mammalian cell adhesion and culture, while the liquid compartment sustains bacterial growth. We demonstrate two droplet architectures that allow physical bacteria–mammalian cell contacts or enforce complete physical separation, representing direct and indirect co-culture. Our multiphasic droplets are stable, customizable, able to sustain co-culture for over 24 hours, and compatible with fluorescence-based cell sorting technologies. Overall, our multiphasic droplet microfluidic platform provides a scalable and versatile tool for high-throughput co-culture and screening of host–microbe interactions.

59 BASIC BIOLOGICAL SCIENCES

Countercurrent distribution of biological cells

A neutral polymer phase system consisting of 7.5 percent dextran 40/4.5 percent PEG 6, 0.11 M Na phosphate, 5 percent fetal bovine serum (FBS), pH 7.5, was developed which has a high phase droplet electrophoretic mobility and retains cell viability over many hours. In this and related systems, the drop mobility was a linear function of drop size, at least in the range 4-30 micron diameter. Applications of and electric field of 4.5 v/cm to a system containing 10 percent v/v bottom phase cleared the system more than two orders of magnitude faster than in the absence of the field. At higher bottom phase concentrations a secondary phenomenon intervened in the field driven separations which resulted in an increase in turbidity after clearing had commenced. The increase was associated with a dilution of the phase system in the chamber. The effect depended on the presence of the electric field. It may be due to electroosmotic flow of buffer through the Amicon membranes into the sample chamber and flow of phase system out into the rinse stream. Strategies to eliminate this problem are proposed.

Brooks, D. E.

Separation of biological materials in microgravity

Partition in aqueous two phase polymer systems is a potentially useful procedure in downstream processing of both molecular and particulate biomaterials. The potential efficiency of the process for particle and cell isolations is much higher than the useful levels already achieved. Space provides a unique environment in which to test the hypothesis that convection and settling phenomena degrade the performance of the partition process. The initial space experiment in a series of tests of this hypothesis is described.

Brooks, D. E.

New Secondary Batteries Using Electronically Conductive Polymer Cathodes

A Li/Polypyrrole secondary battery was designed and built, and the effect of controlling the morphology of the polymer on enhancement of counterion diffusion in the polymer phase was explored. The experimental work was done at Colorado State University, while the mathematical modeling of the battery was done at Texas A and M University. Manuscripts and publications resulting from the project are listed.

Martin, Charles R.

Optical Spectroscopy of New Materials

Composites are currently used for a rapidly expanding number of applications including aircraft structures, rocket nozzles, thermal protection of spacecraft, high performance ablative surfaces, sports equipment including skis, tennis rackets and bicycles, lightweight automobile components, cutting tools, and optical-grade mirrors. Composites are formed from two or more insoluble materials to produce a material with superior properties to either component. Composites range from dispersion-hardened alloys to advanced fiber-reinforced composites. UV/VIS and FTIR spectroscopy currently is used to evaluate the bonding between the matrix and the fibers, monitor the curing process of a polymer, measure surface contamination, characterize the interphase material, monitor anion transport in polymer phases, characterize the void formation (voids must be minimized because, like cracks in a bulk material, they lead to failure), characterize the surface of the fiber component, and measure the overall optical properties for energy balances.

White, Susan M.

Phase-Imaging with a Sharpened Multi-Walled Carbon Nanotube AFM Tip: Investigation of Low-k Dielectric Polymer Hybrids

Phase shift tapping mode scanning force microscopy (TMSFM) has evolved into a very powerful technique for the nanoscale surface characterization of compositional variations in heterogeneous samples. Phase shift signal measures the difference between the phase angle of the excitation signal and the phase angle of the cantilever response. The signal correlates to the tip-sample inelastic interactions, identifying the different chemical and/or physical property of surfaces. In general, the resolution and quality of scanning probe microscopic images are highly dependent on the size of the scanning probe tip. In improving AFM tip technology, we recently developed a technique for sharpening the tip of a multi-walled carbon nanotube (CNT) AFM tip, reducing the radius of curvature of the CNT tip to less than 5 nm while still maintaining the inherent stability of multi-walled CNT tips. Herein we report the use of sharpened (CNT) AFM tips for phase-imaging of polymer hybrids, a precursor for generating nanoporous low-k dielectrics for on-chip interconnect applications. Using sharpened CNT tips, we obtained phase-contrast images having domains less than 10 nm. In contrast, conventional Si tips and unsharpened CNT tips (radius greater than 15 nm) were not able to resolve the nanoscale domains in the polymer hybrid films. C1early, the size of the CNT tip contributes significantly to the resolution of phase-contrast imaging. In addition, a study on the nonlinear tapping dynamics of the multi-walled CNT tip indicates that the multi-walled CNT tip is immune to conventional imaging instabilities related to the coexistence of attractive and repulsive tapping regimes. This factor may also contribute to the phase-contrast image quality of multi-walled CNT AFM tips. This presentation will also offer data in support of the stability of the CNT tip for phase shift TMSFM.

Nguyen, Cattien V.

Superstructural phase transitions in polymer-grafted nanooctahedra

Superlattices of polyhedral nanocrystals exhibit emergent properties defined by their structural arrangements, but native nanocrystal ligands often limit their programmability. Polymeric ligands address this limitation by enabling tunable nanocrystal softness through modifications of polymer molecular weight and grafting density. Here, we investigate phase transitions in polymer-grafted nanooctahedra by varying polymer length, nanocrystal size, truncation, and ligand density. In two-dimensional superlattices, longer polymers or smaller nanooctahedra induce a transition from orientationally ordered to hexagonal rotator lattices. In three-dimensional superlattices, increasing polymer length drives transitions from Minkowski to body-centered cubic and plastic hexagonal close-packed phases, while higher grafting densities further enable transitions to simple hexagonal phases. Polymer brush and thermodynamic perturbation theories, supported by Monte Carlo simulations, uncover the entropic and enthalpic forces that govern these transitions. This work highlights the versatility of polymer-grafted anisotropic nanocrystals as building blocks for designing hierarchical superstructures and metamaterials with customizable properties.

36 MATERIALS SCIENCE