Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Planar Laser Induced Fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Stereoscopic Planar Laser-Induced Fluorescence Imaging at 500 kHz

A new measurement technique for obtaining time- and spatially-resolved image sequences in hypersonic flows is developed. Nitric-oxide planar laser-induced fluorescence (NO PLIF) has previously been used to investigate transition from laminar to turbulent flow in hypersonic boundary layers using both planar and volumetric imaging capabilities. Low flow rates of NO were typically seeded into the flow, minimally perturbing the flow. The volumetric imaging was performed at a measurement rate of 10 Hz using a thick planar laser sheet that excited NO fluorescence. The fluorescence was captured by a pair of cameras having slightly different views of the flow. Subsequent stereoscopic reconstruction of these images allowed the three-dimensional flow structures to be viewed. In the current paper, this approach has been extended to 50,000 times higher repetition rates. A laser operating at 500 kHz excites the seeded NO molecules, and a camera, synchronized with the laser and fitted with a beam-splitting assembly, acquires two separate images of the flow. The resulting stereoscopic images provide three-dimensional flow visualizations at 500 kHz for the first time. The 200 ns exposure time in each frame is fast enough to freeze the flow while the 500 kHz repetition rate is fast enough to time-resolve changes in the flow being studied. This method is applied to visualize the evolving hypersonic flow structures that propagate downstream of a discrete protuberance attached to a flat plate. The technique was demonstrated in the NASA Langley Research Center s 31-Inch Mach 10 Air Tunnel facility. Different tunnel Reynolds number conditions, NO flow rates and two different cylindrical protuberance heights were investigated. The location of the onset of flow unsteadiness, an indicator of transition, was observed to move downstream during the tunnel runs, coinciding with an increase in the model temperature.

Medford, Taylor L.↗

Computer-controlled multi-parameter mapping of 3D compressible flowfields using planar laser-induced iodine fluorescence

A computer-controlled technique, using planar laser-induced iodine fluorescence, for measuring complex compressible flowfields is presented. A new laser permits the use of a planar two-line temperature technique so that all parameters can be measured with the laser operated narrowband. Pressure and temperature measurements in a step flowfield show agreement within 10 percent of a CFD model except in regions close to walls. Deviation of near wall temperature measurements from the model was decreased from 21 percent to 12 percent compared to broadband planar temperature measurements. Computer-control of the experiment has been implemented, except for the frequency tuning of the laser. Image data storage and processing has been improved by integrating a workstation into the experimental setup reducing the data reduction time by a factor of 50.

Donohue, James M.↗

Simultaneous 100-kHz Acetone Planar Laser-Induced Fluorescence and OH* Chemiluminescence in a Linear Non-Premixed Detonation Channel

Reactant mixing and combustion are investigated in an optically accessible, self-excited linear detonation combustor. The mixing field is captured using 100 kHz planar laser-induced fluorescence (PLIF) imaging of acetone as a tracer in the fuel supply, while 100 kHz chemiluminescence imaging of excited-state hydroxyl (OH*) radicals simultaneously resolves the evolution of the detonation wave. Time sequences are acquired over multiple detonation cycles in each test, with acetone-PLIF images collected along multiple orthogonal planes to reveal the complex three-dimensional topography of the fuel distribution. The instantaneous and phase averaged acetone-PLIF images enable measurement of key fuel injection characteristics, such as the injector recovery time, fuel jet velocity, and refill height for a range of operating conditions. Instantaneous and phase-averaged measurements of acetone-PLIF with the time-coincident OH* chemiluminescence images also reveal a number key features, such as fuel stratification and weak detonation in the injector near field, incomplete combustion and deflagration behind the detonation wave, vitiation and deflagration of reactants ahead of the detonation wave, and fuel and oxidizer recovery time mismatch leading to combustion inefficiency. These measurements significantly enhance the ability to obtain detailed information on the intracycle and intercycle spatiotemporal evolution of the reactant refill process and its coupled effects on the detonation wave structure and propagation.

Propulsion↗

Planar Laser-Induced Iodine Fluorescence Measurements in Rarefied Hypersonic Flow

A planar laser-induced fluorescence (PLIF) technique is discussed and applied to measurement of time-averaged values of velocity and temperature in an I(sub 2)-seeded N(sub 2) hypersonic free jet facility. Using this technique, a low temperature, non-reacting, hypersonic flow over a simplified model of a reaction control system (RCS) was investigated. Data are presented of rarefied Mach 12 flow over a sharp leading edge flat plate at zero incidence, both with and without an interacting jet issuing from a nozzle built into the plate. The velocity profile in the boundary layer on the plate was resolved. The slip velocity along the plate, extrapolated from the velocity profile data, varied from nearly 100% down to 10% of the freestream value. These measurements are compared with results of a DSMC solution. The velocity variation along the centerline of a jet issuing from the plate was measured and found to match closely with the correlation of Ashkenas and Sherman. The velocity variation in the oblique shock terminating the jet was resolved sufficiently to measure the shock wave thickness.

Cecil, Eric↗

Flame Flashback Investigations in Hydrogen-Enriched Low Swirl Flames using High-Speed Hydroxyl (OH) Planar Laser-Induced Fluorescence

This study reports flashback mechanism observed in hydrogen-enriched flames stabilized in a low swirl burner (LSB) at atmospheric pressure and temperature conditions. The fundamentals of hydrogen-rich stable flames and spatiotemporal investigation of flashback phenomena were observed experimentally using a high-repetition-rate nanosecond (ns)-duration hydroxyl radical planar laser-induced fluorescence (OH-PLIF) diagnostic. Testing was conducted in an optically accessible pre-mixing section of LSB with inlet pre-mixing velocities from 5 to 10 m/s for methane and hydrogen (50 – 90% by mole) blends. Swirlers with two different turning angles, 26 and 33 degrees and three different perforated plate hole diameters, 1.08, 1.12 and 1.16 mm with measured swirl numbers varying from 0.43 to 0.49 were used. The flashback propensity showed dependence on the proximity of the lifted flame to the burner exit which was dependent on pre-mixer velocity, hydrogen content and equivalence ratio (ER). High-speed OH-PLIF images revealed lifted flames were first observed at low ER condition which is changed to M-shaped flame attached to burner rim with the increase in ER. Then, further increase in ER triggers flame flashback into the nozzle. Flashback occurred when burning occurs in the outer shear layer and the leading flame brush ingresses into the nozzle.

Parajuli, Pradeep↗

Flashback Studies of High-Hydrogen Flames using High-Speed OH Planar Laser-Induced Fluorescence

Flame flashback is a crucial challenge during the application of high-hydrogen fuels for the development of next-generation lean premixed combustors. The fundamentals of stable flame configuration, flashback phenomena, and spatiotemporal information of flame dynamics in a premixed, swirl-stabilized burner are investigated experimentally at atmospheric pressure conditions using high-repetition-rate nanosecond (ns)-duration hydroxyl radical planar laser-induced fluorescence (OH-PLIF) measurements. The inlet conditions are varied systematically with respect to equivalence ratio (ϕ), hydrogen percentage in a hydrogen-methane mixture (50%–90%) and pre-mixer velocities and the experiments are performed on the burner modified to provide optical access to the premixing section. Signal interferences such as saturation effects, background chemiluminescence, and laser non-uniformity issues were minimized or corrected during data acquisition and subsequent data processing steps. A stable flame characterization was performed at 20 kHz-repetition-rate for varied pre-mixer velocities, hydrogen content and ϕ in the reactant mixture and lift-off length (L) investigation showed dependence on each of these parameters. Flame dynamics such as flame flashback events, local ignition, local extinction, flame curvature as well as the main reaction zone of the combustion mechanism are well characterized. Flashback ϕ showed an expected linearly increasing trend with increasing pre-mixer velocity and decreasing hydrogen content and the conclusions drawn aligned well with detailed L investigation. Such spatially and temporally resolved kHz-rate OH-PLIF is a promising technique to observe rapidly occurring flashback dynamics and can further validate turbulence-chemistry interaction models of swirling flames.

Parajuli, Pradeep↗

Flame Flashback Investigations in Hydrogen-Enriched Low Swirl Burner using High-Speed Hydroxyl Planar Laser-Induced Fluorescence

Hydrogen/ Hydrogen-rich flame is a potential strategy to reduce carbon emissions for the development of next-generation lean premixed combustors. However, the higher flashback propensity with hydrogen-enrichment owing to faster chemical kinetics is one of the key challenges in existing natural gas turbine combustors. In this study, the fundamentals of stabilized flame dynamics and flashback events in a premixed low swirl burner (LSB) configuration are visualized experimentally using nanosecond (ns)-based high-speed hydroxyl radical planar laser-induced fluorescence (OH-PLIF). The LSB has an optically accessible pre-mixing tube allowing laser diagnostic investigation of flashback events. The inlet conditions are varied systematically with respect to pre-mixer velocities, flame equivalence ratio (ϕ), and hydrogen content and OH-PLIF characterization is performed in stable flame at 20 kHz repetition rate. An increase in flashback propensity is observed with increasing ϕ, hydrogen content, and decreasing V via detailed investigation of flame lift-off length (L) above the burner rim. Flashback ϕ investigations show an expected linearly increasing trend with decreasing hydrogen content and increasing V for each swirler studied and the results agree well with detailed L investigations in stable flame configuration. The propagating flame anchored likely on the back side of the perforated plate within 30-40 ms of the entrance forming the distorted conical flame front.

Parajuli, Pradeep↗

Self-Aligned Focusing Schlieren and OH Planar Laser-Induced Fluorescence Flow Visualization in a Dual-Mode Scramjet

Ahigh-speed self-aligned focusing schlieren (SAFS) system was used to visualize density gradients in and around the cavity flameholder of the combustor section of the University of Virginia Supersonic Combustion Facility (UVASCF). Images with this system were acquired at a framing rate of 110 kHz with no fuel injection, with fuel injection but no flame, and for fuel injection with combustion corresponding to a global equivalence ratio of 𝜙 = 0.18. Images with an air throttle in operation to modify the shock train location with fuel injection and with flame were also acquired. Simultaneous OH planar laser-induced fluorescence (PLIF) images were also acquired at a framing rate of 20 Hz. Results obtained with both visualization techniques are compared to one another to highlight how SAFS can complement more advanced flow visualization techniques and resolve dynamic behavior that may not otherwise be captured. Both proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD) analysis techniques are applied to the SAFS image sequences to identify coherent periodic structures for the runs with fuel injection and combustion.

Brett F Bathel↗

High-efficiency narrow-bandwidth KTP optical parametric oscillator for kHz–MHz planar laser-induced fluorescence

The electronic excitation of key combustion species or flow tagging of chemical species requires a narrowband tunable UV source. In this work, a potassium titanyl phosphate (KTP) burst-mode optical parametric oscillator (OPO) pumped by a 532 nm laser is developed to generate a spectrally narrow signal and an idler output with 1.48 ± 0.19 cm −1 bandwidth without the need for injection seeding. The idler (1410–1550 nm range) is further mixed with 355 or 266 nm to generate 284 or 226 nm for OH or NO planar laser-induced fluorescence (PLIF), respectively, with up to 1.9% conversion efficiency from 1064 nm to the UV. MHz-rate burst profiles are reported, and OH and NO PLIF are demonstrated in a rotating detonation combustor at rates up to 200 kHz.

Webb, Austin M. (ORCID:0000000155897474)↗

Stereoscopic Imaging in Hypersonics Boundary Layers using Planar Laser-Induced Fluorescence

Stereoscopic time-resolved visualization of three-dimensional structures in a hypersonic flow has been performed for the first time. Nitric Oxide (NO) was seeded into hypersonic boundary layer flows that were designed to transition from laminar to turbulent. A thick laser sheet illuminated and excited the NO, causing spatially-varying fluorescence. Two cameras in a stereoscopic configuration were used to image the fluorescence. The images were processed in a computer visualization environment to provide stereoscopic image pairs. Two methods were used to display these image pairs: a cross-eyed viewing method which can be viewed by naked eyes, and red/blue anaglyphs, which require viewing through red/blue glasses. The images visualized three-dimensional information that would be lost if conventional planar laser-induced fluorescence imaging had been used. Two model configurations were studied in NASA Langley Research Center's 31-Inch Mach 10 Air Wind tunnel. One model was a 10 degree half-angle wedge containing a small protuberance to force the flow to transition. The other model was a 1/3-scale, truncated Hyper-X forebody model with blowing through a series of holes to force the boundary layer flow to transition to turbulence. In the former case, low flowrates of pure NO seeded and marked the boundary layer fluid. In the latter, a trace concentration of NO was seeded into the injected N2 gas. The three-dimensional visualizations have an effective time resolution of about 500 ns, which is fast enough to freeze this hypersonic flow. The 512x512 resolution of the resulting images is much higher than high-speed laser-sheet scanning systems with similar time response, which typically measure 10-20 planes.

Danehy, Paul M.↗

Quantitative Measurements of Nitric Oxide Concentration in High-Pressure, Swirl-Stabilized Spray Flames

Lean direct-injection (LDI) spray flames offer the possibility of reducing NO(sub x) emissions from gas turbines by rapid mixing of the liquid fuel and air so as to drive the flame structure toward partially-premixed conditions. We consider the technical approaches required to utilize laser-induced fluorescence methods for quantitatively measuring NO concentrations in high-pressure LDI spray flames. In the progression from atmospheric to high-pressure measurements, the LIF method requires a shift from the saturated to the linear regime of fluorescence measurements. As such, we discuss quantitative, spatially resolved laser-saturated fluorescence (LSF), linear laser-induced fluorescence (LIF), and planar laser-induced fluorescence (PLIF) measurements of NO concentration in LDI spray flames. Spatially-resolved LIF measurements of NO concentration (ppm) are reported for preheated, LDI spray flames at pressures of two to five atmospheres. The spray is produced by a hollow-cone, pressure-atomized nozzle supplied with liquid heptane. NO is excited via the Q(sub 2)(26.5) transition of the gamma(0,0) band. Detection is performed in a two nanometer region centered on the gamma(0,1) band. A complete scheme is developed by which quantitative NO concentrations in high-pressure LDI spray flames can be measured by applying linear LIF. NO is doped into the reactants and convected through the flame with no apparent destruction, thus allowing a NO fluorescence calibration to be taken inside the flame environment. The in-situ calibration scheme is validated by comparisons to a reference flame. Quantitative NO profiles are presented and analyzed so as to better understand the operation of lean-direct injectors for gas turbine combustors. Moreover, parametric studies are provided for variations in pressure, air-preheat temperature, and equivalence ratio. Similar parametric studies are performed for lean, premixed-prevaporized flames to permit comparisons to those for LDI flames. Finally, PLIF is expanded to high pressure in an effort to quantify the detected fluorescence image for LDI flames. Success is achieved by correcting the PLIF calibration via a single-point LIF measurement. This procedure removes the influence of any preferential background that occurs in the PLIF detection window. In general, both the LIF and PLIF measurements verify that the LDI strategy could be used to reduce NO(sub x) emissions in future gas turbine combustors.

Cooper, Clayton S.↗

OH Planar Laser-Induced Fluorescence from Microgravity Droplet Combustion

Droplet combustion under microgravity conditions has been extensively studied, but laser diagnostics have just begun to be employed in microgravity droplet experiments. This is due in part to the level of difficulty associated with laser system size, power and economic availability. Hydroxyl radical (OH) is an important product of combustion, and laser-induced fluorescence (LIF) has proved to be an adequate and sensitive tool to measure OH. In this study, a frequency doubled Nd:YAG laser and a doubled dye laser, compact and reliable enough to perform OH PLIF experiments aboard a parabolic flight-path aircraft, has been developed and successfully demonstrated in a methanol droplet flame experiment. Application to microgravity conditions is planned aboard parabolic flight-path aircraft.

Winter, Michael↗

High repetition rate mapping of the interaction between a laser plasma and magnetized background plasma via laser induced fluorescence

In this work, the laminar coupling of energy between a laser-produced plasma and a background magnetized plasma was investigated via planar laser induced fluorescence diagnostic and magnetic flux probes. Experiments performed on the Large Plasma Device at the University of California, Los Angeles, mapped out the two-dimensional spatiotemporal evolution of the laser-plasma (debris) ion velocity distribution function (VDF) to assess debris-background coupling in a sub-Alfvénic regime. The acquisition of these data necessitates high repetition rate (1 Hz) as each dataset is the accumulation of thousands of laser shots, which would not be feasible in single-shot experiments. Fully kinetic, three-dimensional particle-in-cell simulations are compared to the measured VDFs to provide a framework in which we can understand the coupling of a sub-Alfvénic plasma flow through a preformed, magnetized plasma. The simulations display the same departure from the expected gyromotion of the debris plasma as observed in the experimental data, and in conjunction with the measured magnetic field traces, have led to the direct observation of the collisionless coupling via laminar fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of Hypersonic Nozzle Flow Uniformity Using NO Fluorescence

Planar laser-induced fluorescence visualisation is used to investigate nonuniformities in the flow of a hypersonic conical nozzle. Possible causes for the nonuniformity are outlined and investigated, and the problem is shown to be due to a small step at the nozzle throat. Entrainment of cold boundary layer gas is postulated as the cause of the signal nonuniformity.

O'Byrne, S.↗

Chemically sensitive fluorescence imaging of colliding microdroplets

Here, we present a simple optical capability for generating spatially resolved chemical concentration maps of mixing fluids using a chemically sensitive dye, 1-hydroxy-3,6,8-pyrenetrisulfonic acid, detected by planar laser induced fluorescence. To demonstrate an application of this capability, we investigate the collision and mixing of a pair of microdroplets in air. The two microdroplets are composed of different fluids, methanol and water, with the dye initially in the methanol droplet. When the droplets collide and mixing process develops, the fluorescence of the dye shifts from blue to green as the solvent environment changes. A series of spectral-temporal images of the collision and subsequent mixing are recorded, from which we extract the distribution of the two intermixing droplet species reflected in the spatially resolved dye spectra. Images reveal material transfer between droplets in both coalescing and non-coalescing droplet collisions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗