Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Some rules for polydimensional squeezing

The review of the following results is presented: For mixed state light of N-mode electromagnetic field described by Wigner function which has generic Gaussian form, the photon distribution function is obtained and expressed explicitly in terms of Hermite polynomials of 2N-variables. The momenta of this distribution are calculated and expressed as functions of matrix invariants of the dispersion matrix. The role of new uncertainty relation depending on photon state mixing parameter is elucidated. New sum rules for Hermite polynomials of several variables are found. The photon statistics of polymode even and odd coherent light and squeezed polymode Schroedinger cat light is given explicitly. Photon distribution for polymode squeezed number states expressed in terms of multivariable Hermite polynomials is discussed.

Manko, Vladimir I.↗

Angular momentum of fission fragments from microscopic theory

During nuclear fission, a heavy nucleus splits into two rotating fragments. The associated angular momentum is large, yet the mechanism of its generation and its dependence on the mass of fragments remain poorly understood. In this Letter, we provide the first microscopic calculations of angular-momentum distributions in fission fragments for a wide range of fragment masses. For the benchmark case of 239 Pu(n th ,f), we find that the angular momentum of the fragments is largely determined by the nuclear shell structure and deformation, and that the heavy fragments therefore typically carry less angular momentum than their light partners. We use the fission model freya to simulate the emission of neutrons and photons from the fragments. The dependence of the angular momenta on fragment mass after the emission of neutrons and statistical photons is linear for the heavy fragments and either constant or weakly linear for the light fragments, consistent with the universal sawtooth pattern suggested by recent experimental data. Finally, we observe that using microscopic angular-momentum distributions modifies the number of emitted photons significantly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution detectors for imaging and spectroscopy at ultraviolet and soft X-ray wavelengths

The Multi-Anode Microchannel Arrays (MAMAs) are a family of pulse-counting imaging array detectors designed specifically for astrophysical investigations in space. The MAMAs have a number of unique performance characteristics which make them particularly suitable for imaging and spectroscopy at ultraviolet and soft X-ray wavelengths. First, they employ 'solar blind' photocathodes eliminating the 'red leak' problem associated with solid state arrays such as the CCDs. Second, they operate with zero readout noise, yielding photon-statistics limited signals. Third, they utilize a random readout technique and can determine both the location of a detected photon and also its arrival time to an accuracy of the order of 100 ns. This paper gives an overview of the construction, mode of operation, and performance characteristics of the MAMA detectors and describes the current status of the development program.

Timothy, J. G.↗

Proposed framework for applying squeezed light to multi-photon absorption plasma diagnostics

We propose a quantum-enhanced plasma diagnostic based on squeezed states of light. Squeezed light can exhibit super-Poissonian photon statistics, leading to enhanced multiphoton absorption cross-sections compared to classical light. This effect enables improved sensitivity for two-photon excitation of high-energy atomic transitions such as ground-state excitation, and results in increased absorbed power and fluorescence in a plasma. We consider two methods of generating squeezed states and evaluate their advantages and limitations in the context of plasma absorption diagnostics. By comparing with and extending previous theoretical work, we predict an enhancement of the absorption signal by up to seven orders of magnitude at low intensities (10 1 W/m 2 ), with diminishing enhancement persisting up to high intensities (10 10 W/m 2 ). These results suggest that squeezed-light sources offer a viable pathway toward quantum-enhanced plasma diagnostics.

imaging↗

Statistical error analysis in CCD time-resolved photometry with applications to variable stars and quasars

Differential photometric time series obtained from CCD frames are tested for intrinsic variability using a newly developed analysis of variance technique. In general, the objects used for differential photometry will not all be of equal magnitude, so the techniques derived here explicitly correct for differences in the measured variances due to photon statistics. Other random-noise terms are also considered. The technique tests for the presence of intrinsic variability without regard to its random or periodic nature. It is then applied to observations of the variable stars ZZ Ceti and US 943 and the active extragalactic objects OQ 530, US 211, US 844, LB 9743, and OJ 287.

Howell, Steve B.↗

Amplitude squeezed light from a laser

Intensity squeezed light was successfully generated using semiconductor lasers with sub-Poissonian pumping. Control of the pumping statistics is crucial and is achieved by a large series resistor which regulates the pump current; its sub-Poissonian statistics are then transferred to the laser output. The sub-Poissonian pumping of other laser systems is not so simple, however, and their potential as squeezed states sources is apparently diminished. We consider a conventional laser incoherently pumped well above threshold, and allow for pump depletion of the ground state. In this regime, sub-Poissonian photon statistics and squeezed amplitude fluctuations are produced.

Hart, D. L.↗

Statistical Properties of Undulator Radiation

Two experiments were carried out to study the statistical properties of undulator radiation in the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The first experiment studied the turn-to-turn fluctuations in the power of the radiation generated by an electron bunch. The magnitude of these fluctuations depends on the 6D phase-space distribution of the electron bunch. In IOTA, we demonstrated that this effect can be used to measure some electron bunch parameters, small transverse emittances in particular. In the second experiment, a single electron was stored in the ring, emitting a photon only once per several hundred turns. In this regime, any classical interference-related collective effects were eliminated, and the quantum fluctuations could be studied in detail to search for possible deviations from the expected Poissonian photon statistics. In addition, the photocount arrival times were used to track the longitudinal motion of a single electron and to compare it with simulations. This allowed us to determine several dynamical parameters of the storage ring such as the rf cavity phase jitter and the dependence of the synchrotron motion period on amplitude.

43 PARTICLE ACCELERATORS↗

The XXL Survey I. Scientific Motivations - Xmm-Newton Observing Plan - Follow-up Observations and Simulation Programme

The quest for the cosmological parameters that describe our universe continues to motivate the scientific community to undertake very large survey initiatives across the electromagnetic spectrum. Over the past two decades, the Chandra and XMM-Newton observatories have supported numerous studies of X-ray-selected clusters of galaxies, active galactic nuclei (AGNs), and the X-ray background. The present paper is the first in a series reporting results of the XXL-XMM survey; it comes at a time when the Planck mission results are being finalized. Aims. We present the XXL Survey, the largest XMM programme totaling some 6.9 Ms to date and involving an international consortium of roughly 100 members. The XXL Survey covers two extragalactic areas of 25 deg2 each at a point-source sensitivity of approx. 5 x 10(exp 15) erg/s/sq cm in the [0.5-2] keV band (completeness limit). The surveys main goals are to provide constraints on the dark energy equation of state from the space-time-distribution of clusters of galaxies and to serve as a pathfinder for future, wide-area X-ray missions. We review science objectives, including cluster studies, AGN evolution, and large-scale structure, that are being conducted with the support of approximately 30 follow-up programs. Methods. We describe the 542 XMM observations along with the associated multi- and numerical simulation programmes. We give a detailed account of the X-ray processing steps and describe innovative tools being developed for the cosmological analysis. Results. The paper provides a thorough evaluation of the X-ray data, including quality controls, photon statistics, exposure and background maps, and sky coverage. Source catalogue construction and multi-associations are briefly described. This material will be the basis for the calculation of the cluster and AGN selection functions, critical elements of the cosmological and science analyses. Conclusions. The XXL multi- data set will have a unique lasting legacy value for cosmological and extragalactic studies and will serve asa calibration resource for future dark energy studies with clusters and other X-ray selected sources. With the present article, we release the XMM XXL photon and smoothed images along with the corresponding exposure maps.

X-rays: general – large-scale structure of Unive↗

Ancilla-free continuous-variable SWAP test

We propose a continuous-variable (CV) SWAP test that requires no ancilla register, thereby generalizing the ancilla-free SWAP test for qubits. In this ancilla-free CV SWAP test, the computational basis measurement is replaced by photon number-resolving measurement, and we calculate an upper bound on the error of the overlap estimate obtained from a finite Fock cutoff in the detector. As an example, we show that estimation of the overlap of pure, centered, single-mode Gaussian states of energy E and squeezed in opposite quadratures can be obtained to error ϵ using photon statistics below a Fock basis cutoff O(Elnϵ –1 ). This cutoff is greatly reduced to E + O(√ Elnϵ –1 ) when the states have rapidly decaying Fock tails, such as coherent states. We show how the ancilla-free CV SWAP test can be extended to many modes and applied to quantum algorithms such as variational compiling and entanglement spectroscopy in the CV setting. For the latter we also provide a new algorithm which does not have an analog in qubit systems. The ancilla-free CV SWAP test is implemented on Xanadu's 8-mode photonic processor in order to estimate the vacuum probability of a two-mode squeezed state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Entangled Photon Spectroscopy

Conspectus The enhanced interest in quantum-related phenomena has provided new opportunities for chemists to push the limits of detection and analysis of chemical processes. As some have called this the second quantum revolution, a time has come to apply the rules learned from previous research in quantum phenomena toward new methods and technologies important to chemists. While there has been great interest recently in quantum information science (QIS), the quest to understand how nonclassical states of light interact with matter has been ongoing for more than two decades. Our entry into this field started around this time with the use of materials to produce nonclassical states of light. Here, the process of multiphoton absorption led to photon-number squeezed states of light, where the photon statistics are sub-Poissonian. In addition to the great interest in generating squeezed states of light, there was also interest in the formation of entangled states of light. While much of the effort is still in foundational physics, there are numerous new avenues as to how quantum entanglement can be applied to spectroscopy, imaging, and sensing. These opportunities could have a large impact on the chemical community for a broad spectrum of applications. Here, we discuss the use of entangled (or quantum) light for spectroscopy as well as applications in microscopy and interferometry. The potential benefits of the use of quantum light are discussed in detail. From the first experiments in porphyrin dendrimer systems by Dr. Dong-Ik Lee in our group to the measurements of the entangled two photon absorption cross sections of biological systems such as flavoproteins, the usefulness of entangled light for spectroscopy has been illustrated. These early measurements led the way to more advanced measurements of the unique characteristics of both entangled light and the entangled photon absorption cross-section, which provides new control knobs for manipulating excited states in molecules. The first reports of fluorescence-induced entangled processes were in organic chromophores where the entangled photon cross-section was measured. These results would later have widespread impact in applications such as entangled two-photon microscopy. From our design, construction and implementation of a quantum entangled photon excited microscope, important imaging capabilities were achieved at an unprecedented low excitation intensity of 10 7 photons/s, which is 6 orders of magnitude lower than the excitation level for the classical two-photon image. New reports have also illustrated an advantage of nonclassical light in Raman imaging as well. From a standpoint of more precise measurements, the use of entangled photons in quantum interferometry may offer new opportunities for chemistry research. Experiments that combine molecular spectroscopy and quantum interferometry, by utilizing the correlations of entangled photons in a Hong–Ou–Mandel (HOM) interferometer, have been carried out. The initial experiment showed that the HOM signal is sensitive to the presence of a resonant organic sample placed in one arm of the interferometer. In addition, parameters such as the dephasing time have been obtained with the opportunity for even more advanced phenomenology in the future.

36 MATERIALS SCIENCE↗

Measurement of energy resolution with the NEXT-White silicon photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}$Kr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 ± 0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.[graphic not available: see fulltext]

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of borated scintillator screens for high-resolution neutron imaging

The most commonly used screens for neutron imaging consist of 6 LiF + ZnS. This type of screen yields the highest light output per detected neutron. For high resolution, gadolinium oxysulfide (GOS, Gadox) screens are employed, which have a much higher detection efficiency, but a light output so much lower than LiF + ZnS that measurements are often limited by photon statistics. Historically, screens using boron as a neutron-sensitive material have not been very successful. However, a new preparation method was introduced recently that produces light output higher than Gadox with detection efficiency greater than LiF + ZnS. Measurements of these new borated screens were performed at the NeXT facility at ILL, Grenoble, in comparison to a high resolution Gadox screen.

10B↗

Single-Particle Spectroscopy as a Versatile Tool to Explore Lower-Dimensional Structures of Inorganic Perovskites

The remarkable defect tolerant nature of inorganic cesium halide perovskites leading to near unity photoluminescence (PL) quantum yield (QY) and narrow emission linewidth across the entire visible spectrum, have provided a tantalizing platform for a development of a plethora of light-emitting applications. Recently, lower dimensional (2D, 1D, and 0D) perovskites have attracted further attention due to the enhanced thermal, photo and chemical stability as compared to their three-dimensional (3D) analogues. Combination of the external size quantization and internal octahedral organization provides a unique opportunity to study and harness “multidimensional” electronic properties engineered both on atomic scale and the nanoscale. However, crucial research to understand the elementary charge carrier dynamics in lower dimensional perovskites lags far behind the enormous effort to incorporate them into optoelectronic devices. In this Perspective, we provide a review of recent developments that focus on studies of the dynamics of excitonic complexes in Cs-based perovskite nanocrystals using single-particle time-resolved PL spectroscopy and photon correlation measurements. Single photon statistical studies not only offer the unprecedented level of detail to directly assess various recombination pathways but also provide insights into specifics of carrier’s localization. Further, we discuss the underlying physicochemical processes that govern PL emission and draw attention to a number of attributes within this class of the materials, especially lower-dimensional perovskites that may indicate the common origin of the PL emission, as well as provide a route map for the vast unexplored territories where single particle spectroscopy can be a powerful tool to unravel crucial information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved motional Stark effect signal processing using fast Fourier transform spectral analysis

A Fast Fourier Transform (FFT) based method has been developed, which improves the frequency response of the Motional Stark Effect (MSE) system by about a factor of 10 over the conventional analog lock-in method. The method uses fits to rigorously derived analytic expressions for the FFT spectral components of the MSE signal to accurately obtain the amplitudes and phases of the 2f1 and 2f2 photo-elastic modulator (PEM) frequencies that encode the polarization angle. Since no frequency filtering is used in the FFT method, the frequency response is limited by fundamental measurement properties: the frequency response of the detector, photon statistics, sample rate, and the ability to resolve the spectral components. In contrast, the frequency response of the analog lock-in is limited by a low pass filter with a cutoff of around 500 Hz. In the case of the DIII-D MSE system, the output of the photo-multiplier tube detector was sampled at 500 kHz and FFTs with as few as 100 points were used to obtain the amplitudes of the 2f1 and 2f2 PEM frequency components. This corresponds to a frequency response of 5 kHz, about ten times faster than the analog lock-in amplifier system. Details of the FFT method will be presented and compared to those of the analog lock-in system.

Makowski, M. A.↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

Predicting the single-site and multi-site event discrimination power of dual-phase time projection chambers

Dual-phase xenon time projection chambers (TPCs) are widely used in searches for rare dark matter and neutrino interactions, in part because of their excellent position reconstruction capability in 3D. Despite their millimeter-scale resolution along the charge drift axis, xenon TPCs face challenges in resolving single-site (SS) and multi-site (MS) interactions in the transverse plane. In this paper, we build a generic TPC model with an idealized signal readout, and use Fisher Information (FI) to predict its theoretical capability of differentiating SS and MS events using the electroluminescence signal. We also demonstrate via simulation that, when only statistical photon noise is present, the theoretical limits can be approached with conventional reconstruction algorithms like maximum likelihood estimation, and with a convolutional neural network classifier. The implications of this study on future TPC experiments will be discussed.

Physics↗

Simulating quantum-classical interfaces via the Lindblad master equation

In hybrid quantum systems, the interface between quantum and classical domains is essential for the generation, control, and measurement of quantum states. Quantum-classical interfaces (QCIs) are ubiquitous in devices such as optical modulators, quantum sensors, and signal processors, where classical signals influence quantum dynamics. In this paper, we employ the Lindblad master equation to simulate the evolution of a quantum system interacting with a classical control system. Our model captures both linear and nonlinear interactions by incorporating first- and second-order susceptibilities, and it quantifies the influence of externally applied control parameters on decoherence and state evolution. As an illustrative example, we analyze an optical modulator and demonstrate how variations in material response and drive conditions affect photon statistics, coherence, and phase-space distributions. In conclusion, the findings offer a path to an all-encompassing model for understanding and optimizing QCIs, with wide-ranging implications for the performance, design, and robustness of next-generation quantum devices.

Quantum engineering↗