Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phosphorous parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

34 records · Page 2

Study to determine and improve design for lithium-doped solar cells

Solar cell experiments show that a single lithium density parameter, the lithium density gradient, calculated from nondestructive capacitance measurements, provides the basis for accurate predictions of lithium cell behavior in a 1-MeV electron environment for fluences ranging between 3 X 10 to the 13th power e/sq cm and 3 X 10 to the 15th power/e sq cm. The oxygen-rich (quartz crucible) lithium cell with phosphorous starting dopant and lithium gradient between approximately 5 X 10 to the 18th power and 1.5 x 10 to the 19th power/cm to the 4th power was found superior in performance to the commercial 10 ohm-cm n/p control cells. Post-recovery stability of oxygen-rich cells was satisfactory. An average post-recovery current drop of approximately 1 mA was observed for 70 crucible cells after 1 year-equivalent storage time at 80 C. In contrast the oxygen-poor (float zone and Lopex) lithium cells displayed spotty initial performance and stability problems at room temperature.

Brucker, G.↗

DC Modeling of 4H-SiC JFET Gate Length Reduction at 500°C

The development of robust, high-performance integrated circuits (ICs) will enable numerous potential NASA missions of current interest, including long-duration robotic missions exploring the 460 °C surface of Venus. Currently, NASA is looking towards SiC-based devices to provide such a solution. However, the current NASA silicon carbide (SiC) JFET device with a channel length of 6μm (for recently fabricated Gen. 11 ICs) limits on mission relevant circuit capabilities [1]. In this study, we combined experiments with simulations to explore two straightforward fabrication strategies to reduce the SiC JFET channel length while maintaining turn-off behavior (Fig. 1a) needed to realize 500 °C circuit operation. The first fabrication strategy uses a shallow self-align nitrogen implant (Figure 1b) along the device's top surface but not below the gate combined with a high-dose phosphorous implant directly below the source and drain contacts. For the second fabrication strategy (Figure 1c), the high-dose phosphorous implants extended from below the contacts all the way up to the gate edges. Simulations guided gate length reductions without significant degradation in the turn-off performance. In total 12 SiC JFET variants implementing using the different fabrication strategies, gate lengths, and n-channel epilayer thickness were implemented in our simulation framework implemented in COMSOL. Since the COMSOL database does not have the material properties for 4H-SiC, these parameters were taken from the literature and implemented in COMSOL. The empirical models [2] for incomplete ionization, Auger recombination, low field mobility, and Shockley-Read-Hall recombination were implemented to account for material-specific device behavior.

4H-SiC JFET↗

The mechanism of erosion of metallic materials under cavitation attack

The mean depth of penetration rates (MDPRs) of eight polycrystalline metallic materials, Al 6061-T6, Cu, brass, phosphor bronze, Ni, Fe, Mo, and Ti-5Al-2.5Sn exposed to cavitation attack in a viscous mineral oil with a 20 kHz ultrasonic oscillator vibrating at 50 micron amplitude are reported. The titanium alloy followed by molybdenum have large incubation periods and small MDPRs. The incubation periods correlate linearly with the inverse of hardness and the average MDPRs correlate linearly with the inverse of tensile strength of materials. The linear relationships yield better statistical parameters than geometric and exponential relationships. The surface roughness and the ratio of pit depth to pit width (h/a) increase with the duration of cavitation attack. The ratio h/a varies from 0.1 to 0.8 for different materials. Recent investigations (20) using scanning electron microscopy to study deformation and pit formation features are briefly reviewed. Investigations with single crystals indicate that the geometry of pits and erosion are dependent on their orientation.

Rao, B. C. S.↗

Contact Whiskers for Millimeter Wave Diodes

Several techniques are investigated for making short conical tips on wires (whiskers) used for contacting millimeter-wave Schottky diodes. One procedure, using a phosphoric and chromic acid etching solution (PCE), is found to give good results on 12 microns phosphor-bronze wires. Full cone angles of 60 degrees-80 degrees are consistently obtained, compared with the 15 degrees-20 degrees angles obtained with the widely used sodium hydroxide etch. Methods are also described for cleaning, increasing the tip diameter (i.e. blunting), gold plating, and testing the contact resistance of the whiskers. The effects of the whisker tip shape on the electrical resistance, inductance, and capacitance of the whiskers are studied, and examples given for typical sets of parameters.

Kerr, A. R.↗

Evaluation of gas cooling for pressurized phosphoric acid fuel cell stacks

Gas cooling is a more reliable, less expensive and a more simple alternative to conventional liquid cooling for heat removal from the phosphoric acid fuel cell (PAFC). The feasibility of gas cooling has already been demonstrated in atmospheric pressure stacks. This paper presents theoretical and experimental investigation of gas cooling for pressurized PAFC. Two approaches to gas cooling, Distributed Gas Cooling (DIGAS) and Separated Gas Cooling (SGC) were considered, and a theoretical comparison on the basis of cell performance indicated SGC to be superior to DIGAS. The feasibility of SGC was experimentally demonstrated by operating a 45-cell stack for 700 hours at pressure, and determining thermal response and the effect of other related parameters.

Farooque, M.↗

A study of trends and techniques for space base electronics

A sputtering system was developed to deposit aluminum and aluminum alloys by the dc sputtering technique. This system is designed for a high level of cleanliness and for monitoring the deposition parameters during film preparation. This system is now ready for studying the deposition and annealing parameters upon double-level metal preparation. A technique recently applied for semiconductor analysis, the finite element method, was studied for use in the computer modeling of two dimensional MOS transistor structures. It was concluded that the method has not been sufficiently well developed for confident use at this time. An algorithm was developed for confident use at this time. An algorithm was developed for implementing a computer study which is based upon the finite difference method. The program which was developed was modified and used to calculate redistribution data for boron and phosphorous which had been predeposited by ion implantation with range and straggle conditions. Data were generated for 111 oriented SOS films with redistribution in N2, dry O2 and steam ambients.

Trotter, J. D.↗

Evaluation of Gas-Cooled Pressurized Phosphoric Acid Fuel Cells for Electric Utility Power Generation

Gas cooling is a more reliable, less expensive and a more simple alternative to conventional liquid cooling for heat removal from the phosphoric acid fuel cell (PAFC). The feasibility of gas-cooling was already demonstrated in atmospheric pressure stacks. Theoretical and experimental investigations of gas-cooling for pressurized PAFC are presented. Two approaches to gas cooling, Distributed Gas-Cooling (DIGAS) and Separated Gas-Cooling (SGC) were considered, and a theoretical comparison on the basis of cell performance indicated SGC to be superior to DIGAS. The feasibility of SGC was experimentally demonstrated by operating a 45-cell stack for 700 hours at pressure, and determining thermal response and the effect of other related parameters.

Faroque, M.↗

A computer controlled television detector for light, X-rays and particles

A versatile, high resolution, software configurable, two-dimensional intensified vidicon quantum detector system has been developed for multiple research applications. A thin phosphor convertor allows the detection of X-rays below 20 keV and non-relativistic particles in addition to visible light, and a thicker scintillator can be used to detect X-rays up to 100 keV and relativistic particles. Faceplates may be changed to allow any active area from 1 to 40 mm square, and active areas up to 200 mm square are possible. The image is integrated in a digital memory on any software specified array size up to 4000 x 4000. The array size is selected to match the spatial resolution, which ranges from 10 to 100 microns depending on the operating mode, the active area, and the photon or particle energy. All scan and data acquisition parameters are under software control to allow optimal data collection for each application.

Kalata, K.↗

Pressure Gradient Effects on Hypersonic Cavity Flow Heating

The effect of a pressure gradient on the local heating disturbance of rectangular cavities tested at hypersonic freestream conditions has been globally assessed using the two-color phosphor thermography method. These experiments were conducted in the Langley 31-Inch Mach 10 Tunnel and were initiated in support of the Space Shuttle Return-To-Flight Program. Two blunted-nose test surface geometries were developed, including an expansion plate test surface with nearly constant negative pressure gradient and a flat plate surface with nearly zero pressure gradient. The test surface designs and flow characterizations were performed using two-dimensional laminar computational methods, while the experimental boundary layer state conditions were inferred using the measured heating distributions. Three-dimensional computational predictions of the entire model geometry were used as a check on the design process. Both open-flow and closed-flow cavities were tested on each test surface. The cavity design parameters and the test condition matrix were established using the computational predictions. Preliminary conclusions based on an analysis of only the cavity centerline data indicate that the presence of the pressure gradient did not alter the open cavity heating for laminar-entry/laminar-exit flows, but did raise the average floor heating for closed cavities. The results of these risk-reduction studies will be used to formulate a heating assessment of potential damage scenarios occurring during future Space Shuttle flights.

Everhart, Joel L.↗

Pressure Gradient Effects on Hypersonic Cavity Flow Heating

The effect of a pressure gradient on the local heating disturbance of rectangular cavities tested at hypersonic freestream conditions has been globally assessed using the two-color phosphor thermography method. These experiments were conducted in the Langley 31-Inch Mach 10 Tunnel and were initiated in support of the Space Shuttle Return-To-Flight Program. Two blunted-nose test surface geometries were developed, including an expansion plate test surface with nearly constant negative pressure gradient and a flat plate surface with nearly zero pressure gradient. The test surface designs and flow characterizations were performed using two-dimensional laminar computational methods, while the experimental boundary layer state conditions were inferred using the measured heating distributions. Three-dimensional computational predictions of the entire model geometry were used as a check on the design process. Both open-flow and closed-flow cavities were tested on each test surface. The cavity design parameters and the test condition matrix were established using the computational predictions. Preliminary conclusions based on an analysis of only the cavity centerline data indicate that the presence of the pressure gradient did not alter the open cavity heating for laminar-entry/laminar-exit flows, but did raise the average floor heating for closed cavities. The results of these risk-reduction studies will be used to formulate a heating assessment of potential damage scenarios occurring during future Space Shuttle flights.

Everhart, Joel L.↗

Cavity Heating Experiments Supporting Shuttle Columbia Accident Investigation

The two-color thermographic phosphor method has been used to map the local heating augmentation of scaled idealized cavities at conditions simulating the windward surface of the Shuttle Orbiter Columbia during flight STS-107. Two experiments initiated in support of the Columbia Accident Investigation were conducted in the Langley 20-Inch Mach 6 Tunnel. Generally, the first test series evaluated open (length-to-depth less than 10) rectangular cavity geometries proposed as possible damage scenarios resulting from foam and ice impact during launch at several discrete locations on the vehicle windward surface, though some closed (length-to-depth greater than 13) geometries were briefly examined. The second test series was designed to parametrically evaluate heating augmentation in closed rectangular cavities. The tests were conducted under laminar cavity entry conditions over a range of local boundary layer edge-flow parameters typical of re-entry. Cavity design parameters were developed using laminar computational predictions, while the experimental boundary layer state conditions were inferred from the heating measurements. An analysis of the aeroheating caused by cavities allowed exclusion of non-breeching damage from the possible loss scenarios being considered during the investigation.

Everhart, Joel L.↗

Changes in nerve conduction and Pi/PCr ratio during denervation-reinnervation of the gastrocsoleus muscles of rats

The purpose of this investigation was to study the changes in nerve conduction and phosphate metabolites of the gastrocsoleus muscles of rats during denervation-reinnervation. Sixteen male Sprague-Dawley rats underwent unilateral crush-denervation of the left sciatic nerves at the sciatic notch. Six rats were used for measurement of motor conduction latency and action potential amplitude of the gastrocsoleus muscle by stimulating the sciatic nerve at one, two and eight weeks after nerve crush. The other ten rats were designated for evaluation of the ratio of inorganic phosphorous (Pi) to phosphocreatine (PCr) by a 31P-phosphoenergetic spectrometer at two weeks and eight weeks after nerve crush. None of the sciatic nerves showed conduction to the gastrocsoleus at one or two weeks after nerve crush. At eight weeks postcrush, the motor conduction latency returned to within normal limits, whereas the action potential amplitude was only 55% of the normal. For the eight-week period of study, the Pi/PCr ratio of the normal control muscles ranged between 0.09 +/- 0.02 and 0.11 +/- 0.02 (mean +/- SD). The denervated muscles showed an increase of Pi/PCr ratio by 54% at two weeks postcrush, compared to the respective contralateral control sides. The ratios returned to the normal value by eight weeks postcrush. In summary, these data suggested that the metabolic recovery of the crush-denervated muscle followed the same pattern as the parameters of nerve conduction.

NASA Center JSC↗

Recent Langley Aerothermodynamic Laboratory Testing (2019-2022)

In support of flight programs, multiple wind tunnel entries were conducted on reentry vehicle configurations to investigate blunt body aeroheating environments. Blunt body block thermal protection system (TPS) roughness, the Low-Earth Orbit Flight Test of an Inflatable Decelerator aeroshell scalloping, and a woven TPS all were tested to determine the effects of those parameters on increased surface heating to the vehicle. Commercial Crew Program studies also utilized the speed and ease of testing in the LAL to analyze parametric databases of low-earth reentry configurations, like the Boeing CST-100, and vehicles designed to travel to the moon or Mars, such as the SpaceX Starship. LAL wind tunnel investigations also supported several DoD and AFRL flight projects, such as HIFiRE 6 and BOLT. External customers leveraged the LAL testing capability to advance their research programs, including UPSTAR, RocketLab, and Lawrence Livermore National Laboratory. Academia groups benefitted from the inexpensive cost to test in the tunnels for many university collaborations, such as studies conducted in partnership with the University of Maryland on a flat plate, using a pressure rake and investigating fluid structure interactions. Multiple studies in collaboration with Purdue considered boundary layer transition on various cone configurations. Another study was conducted using a cone with shaped roughness elements borrowed from the Arnold Engineering Development Complex. Internal testing included studies using a phosphor thermography system that can measure higher temperatures than the current LAL phosphor capability and a characterization study of the noise in the wind tunnel flow. The breadth of testing across research and commercial paradigms, both internal and external to NASA, different configurations, a variety of test techniques and aerodynamic and aerothermal environments will be discussed in this overview presentation of the recent work conducted in the LAL.

wind tunnel test↗

Aero-Heating of Shallow Cavities in Hypersonic Freestream Flow

The purpose of these experiments and analysis was to augment the heating database and tools used for assessment of impact-induced shallow-cavity damage to the thermal protection system of the Space Shuttle Orbiter. The effect of length and depth on the local heating disturbance of rectangular cavities tested at hypersonic freestream conditions has been globally assessed using the two-color phosphor thermography method. These rapid-response experiments were conducted in the Langley 31-Inch Mach 10 Tunnel and were initiated immediately prior to the launch of STS-114, the initial flight in the Space Shuttle Return-To-Flight Program, and continued during the first week of the mission. Previously-designed and numerically-characterized blunted-nose baseline flat plates were used as the test surfaces. Three-dimensional computational predictions of the entire model geometry were used as a check on the design process and the two-dimensional flow assumptions used for the data analysis. The experimental boundary layer state conditions were inferred using the measured heating distributions on a no-cavity test article. Two test plates were developed, each containing 4 equally-spaced spanwise-distributed cavities. The first test plate contained cavities with a constant length-to-depth ratio of 8 with design point depth-to-boundary-layer-thickness ratios of 0.1, 0.2, 0.35, and 0.5. The second test plate contained cavities with a constant design point depth-to-boundary-layer-thickness ratio of 0.35 with length-to-depth ratios of 8, 12, 16, and 20. Cavity design parameters and the test condition matrix were established using the computational predictions. Preliminary results indicate that the floor-averaged Bump Factor (local heating rate nondimensionalized by upstream reference) at the tested conditions is approximately 0.3 with a standard deviation of 0.04 for laminar-in/laminar-out conditions when the cavity length-to-boundary-layer thickness is between 2.5 and 10 and for cavities in the depth-to-boundary-layer-thickness range of 0.3 to 0.8. Over this same range of conditions and parameters, preliminary results also indicate that the maximum Bump Factor on the cavity centerline falls between 2.0 and 2.75, as long as the cavity-exit conditions remain laminar. Cavities with length-to-boundary-layer-thickness ratio less than 2.5 can not be easily classified with this approach and require further analysis.

Everhart, Joel L.↗

Molecular-Based Optical Measurement Techniques for Transition and Turbulence in High-Speed Flow

High-speed laminar-to-turbulent transition and turbulence affect the control of flight vehicles, the heat transfer rate to a flight vehicle's surface, the material selected to protect such vehicles from high heating loads, the ultimate weight of a flight vehicle due to the presence of thermal protection systems, the efficiency of fuel-air mixing processes in high-speed combustion applications, etc. Gaining a fundamental understanding of the physical mechanisms involved in the transition process will lead to the development of predictive capabilities that can identify transition location and its impact on parameters like surface heating. Currently, there is no general theory that can completely describe the transition-to-turbulence process. However, transition research has led to the identification of the predominant pathways by which this process occurs. For a truly physics-based model of transition to be developed, the individual stages in the paths leading to the onset of fully turbulent flow must be well understood. This requires that each pathway be computationally modeled and experimentally characterized and validated. This may also lead to the discovery of new physical pathways. This document is intended to describe molecular based measurement techniques that have been developed, addressing the needs of the high-speed transition-to-turbulence and high-speed turbulence research fields. In particular, we focus on techniques that have either been used to study high speed transition and turbulence or techniques that show promise for studying these flows. This review is not exhaustive. In addition to the probe-based techniques described in the previous paragraph, several other classes of measurement techniques that are, or could be, used to study high speed transition and turbulence are excluded from this manuscript. For example, surface measurement techniques such as pressure and temperature paint, phosphor thermography, skin friction measurements and photogrammetry (for model attitude and deformation measurement) are excluded to limit the scope of this report. Other physical probes such as heat flux gauges, total temperature probes are also excluded. We further exclude measurement techniques that require particle seeding though particle based methods may still be useful in many high speed flow applications. This manuscript details some of the more widely used molecular-based measurement techniques for studying transition and turbulence: laser-induced fluorescence (LIF), Rayleigh and Raman Scattering and coherent anti-Stokes Raman scattering (CARS). These techniques are emphasized, in part, because of the prior experience of the authors. Additional molecular based techniques are described, albeit in less detail. Where possible, an effort is made to compare the relative advantages and disadvantages of the various measurement techniques, although these comparisons can be subjective views of the authors. Finally, the manuscript concludes by evaluating the different measurement techniques in view of the precision requirements described in this chapter. Additional requirements and considerations are discussed to assist with choosing an optical measurement technique for a given application.

Bathel, Brett F.↗

Characterization of Magnetoacoustic Emission Related to Structural Properties of Ferromagnets

An extensive study of magnetoacoustic emission (MAE) properties has been performed over the past several years. As a result, the dependence of the spectral characteristics of MAE on certain microstructural variations and uniaxially applied stress in a particular type of low carbon steel are now well known. The embrittlement-causing concentration of certain atomic species, e. g., tin, sulphur, phosphorous etc., at the grain boundaries of this steel creates strong potential barriers resisting the motion of non-180 domain walls which is the source of MAE. (Since the only type of non-180 domain walls in this material are 90 domain walls, the term 90 domain wall will be used throughout this paper in place of non-180 domain wall.) An MAE burst produced during one-half cycle of a hysteresis loop at a low AC magnetic field frequency (e. g., 0.7 Hz) shows two sub-peaks; the leading peak is usually sharp and short-lived, while the trailing peak is usually smooth and long-lasting. It has been shown that the enhanced domain wall-defect interaction, due to the strengthened potential barriers, causes an increase in the asymmetry of the MAE signal by suppressing the leading sub-peak and amplifying the trailing sub-peak. This phenomena is due to the delayed motion of the 90 domain walls. The effect of a tensile stress applied parallel to the external AC magnetic field is to diminish the MAE. On the other hand, the amplitude of the MAE burst has been shown to be a non-monotonic function of the stress amplitude. Recently, our study has concentrated on obtaining quantitative values for parameters computed from the MAE spectra averaged over a sufficient number of cycles to achieve statistical stability. Nevertheless, certain fundamental elements of the MAE characteristics remain unexplained.

Namkung, M.↗