Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

CoURAGE Stationary ELF PTR-MS Measurements at the Mt. Airy Site

Gas phase measurements of volatile organic compounds (VOC) taken at the DOE ARM S2 site for the CoURAGE campaign using a Vocus ELF PTR-ToF (Tofwerk) mass spectrometer. Measurements of several VOC's (e.g., acetaldehyde, acetone, benzene, etc.) were obtained at 1-minute resolution from 4/08 to 5/19.

acetaldehyde_concentration↗

A comparative study of solute trapping in Fe-(33–45 at%) Cu alloys manufactured by laser directed energy deposition

The high cooling rates in laser directed energy deposition (DED-LB) of alloys lead to substantial amounts of solute trapping as solute atoms cannot diffuse away from the solid/liquid interface before it advances. In some concentrated alloys, this results in supersaturated solid phases that form nanoscale hierarchical microstructures when the solute atoms precipitate out during reheating from subsequent laser passes. We choose the Iron-Copper (Fe-Cu) binary alloy as model system as it is chemically homogeneous in the liquid phase and has negligible solid solubility at room temperature. Two alloys with nominal compositions in atomic (at.) %, Fe67Cu33 and Fe55Cu45, were manufactured using DED-LB. Scanning transmission electron microscopy (STEM), energy dispersive spectroscopy (EDS) and wavelength dispersive spectroscopy (WDS) were used to characterize the nanostructures and heterogeneous chemical compositions. A non-equilibrium solute partitioning model was used to compute the supersaturated chemistries of the constituent phases and validated with experimentally measured compositions. The measured phase compositions of the two alloys were very similar, at roughly 12 at.% Cu and 4 at.% Fe in the α(bcc)-Fe and ε(fcc)-Cu phases respectively, despite having different processing parameters and mechanical behavior. This indicates that the total thermal history, that depends on both the processing parameters and laser scan pattern, plays a stronger role on the final microstructure evolution than just the initial quantity of trapped solute. In addition, we find that current non-equilibrium solute partitioning models applied on the continuum scale fall short of predicting accurate quantitative phase compositions in concentrated alloys, although the qualitative trends are captured correctly.

36 MATERIALS SCIENCE↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement of G-phase volume fraction and number density in duplex stainless steels using transmission electron microscopy

Duplex stainless steels (DSS) have a high toughness and strength due the presence of both austenitic and ferritic phases. These alloys have had limited use in power production applications due to thermal embrittlement caused by spinodal decomposition and development of G-phase precipitates in the ferrite. Lean grade DSS alloys (e.g., 2101, 2003) may offer improved thermal stability due to the reduction of Cr- and Ni-equivalent elements when compared to standard grade compositions (e.g., 2205, 2209). The abundance of the G-phase was measured in five duplex stainless steels, three wrought alloys (2101, 2003, 2205) and their matching filler metals (2101-w, 2209-w), after aging at 427 °C for 1000 h and 10,000 h. The G-phase volume fraction, number density, size, and precipitate spacing were found using quantitative analysis of transmission electron microscopy dark field images and the composition of G-phase precipitates on other clusters were characterized with atom probe tomography (APT). In the welded alloys, the G-phase was found to develop rapidly, relative to the wrought material. A positive correlation was found between the nickel equivalent composition of the alloy and the G-phase volume fraction. The alloys 2205, 2209, and 2101-w, which are higher in Cr and Ni, all showed significant G-phase precipitation, further strengthening the hypothesis that lean grade DSS alloys are more thermally stable against precipitation in the ferrite. Electron diffraction showed a secondary phase present in the 2101 wrought alloy at 10,000 h, but it was not crystallographically consistent with the G-phase; APT showed the presence of nanoclusters rich in both nickel and copper for this alloy. In conclusion, no secondary phases or clusters were found in 2003 after 10,000 h of aging, so it may be a candidate alloy for applications that require long-life times at high operating temperatures.

36 MATERIALS SCIENCE↗

Measurement of Beam Energy in the Fermilab's Linac taken at the Transfer Line

Linac is the first machine in the accelerator chain at Fermilab where H$^{-}$ ions are accelerated from 35 keV to 401.5\,MeV and then injected into a synchronton known as Booster where they are stripped of their electrons to become protons. One of the tools used during tuning of the Linac extraction energy is two beam pickups known as Griffin Detectors. Our goal is to control the output energy using machine learning techniques to increase the reliability and quality of the beam delivered from Linac. The first step is to understand the data from the diagnostics to develop reliable and accurate energy measurement, and control methods before implementing machine learning techniques. Two methods of energy measurement were studied, and their results are compared. The first method was the time of flight measurement using Beam Position Monitors that provide beam phase measurement. The second method used the relation between beam transverse positions and dispersion values to calculate momentum variation. The results of these two measurement methods are found to be consistent.

43 PARTICLE ACCELERATORS↗

Sensitivity measurements for a 250 MHz quartz shear-horizontal surface acoustic wave biosensor under liquid viscous loading

Surface acoustic wave (SAW) devices have been used in biochemical assays due to their high sensitivity. The device sensitivity is a function of changes in the density and viscosity of the liquid. Here, we studied the effect of fluid viscosity using a 250 MHz quartz shear-horizontal (SH)-SAW biosensor by monitoring different concentrations of binary aqueous/glycerol solutions. In this study, the sensitivity of the biosensor was determined by fitting the data to models derived from perturbation theory. Measurements in water were used as the reference. For a 0% to 50% glycerol solution, an 87°–204° separation in the phase shift was observed. The slope of the plot of the phase shift vs (ηρ)0.5 was used to indicate the sensor’s sensitivity. The sensitivity for our 250 MHz quartz SH-SAW sensors was calculated to be 3.7×10−3m2sKg. The corresponding mass sensitivity was determined to be 9.25 × 105m2Kg. The limit of detection was calculated to be 36 picograms (pg), while the limit of quantification or LOQ was calculated to be 109 pg. Traditionally, liquid phase measurements have been challenging for SAW devices because liquids dampen the vibrating sensors severely. This problem has been largely solved using a transverse (shear) wave instead of the more popular longitudinal or Rayleigh waves. Liquid measurements are now possible using transverse waves, also known as shear waves, because transverse waves are only minimally attenuated by liquids. Shear-horizontal SAW sensors (SH-SAW) show great promise as label-free biosensors because of their ability to handle liquid samples. However, the viscosity of the liquid still induces loading effects and can be measured when the liquid is loaded onto the SH-SAW propagating surface (delay line). When the liquid above the delay line is perturbed by physical or chemical changes, such as binding to a receptor, it alters the propagating acoustic wave. The SH-SAW device can measure these changes in liquid properties as a change in the wave’s phase compared to the original wave. The device’s phase shift was recorded as a function of the changes in the density and viscosity of the binary glycerol solution and used to determine the sensitivity in the linear dynamic range of responses.

Materials Science↗

X-ray diffraction strains in laser-ablated aluminum, nickel, sodium, and invar: Pressures to 475 GPa

Dynamically compressed materials in longitudinal waves are described by two physical models: hydrostatic pressure, with equal, normal, principal stresses or material uniaxially strained in the wave propagation direction. These models are disparate, so experimental comparisons and evaluations are important. Polycrystalline material in a state of hydrostatic pressure will have no eccentricity of x-ray-diffracted Debye–Scherrer rings. A general three-dimensional solution of Bragg diffracted x rays based on principal crystallographic strains in the compression wave was found. The distortion of x-ray diffraction beams has been used for strain measurements; the analysis developed incorporates a strained reciprocal lattice and the incident x-ray beam. Strain-distorted Polanyi surfaces form an annulus of compression with an ellipsoid of revolution in reciprocal space, which is intersected by Ewald's sphere for Bragg diffraction. The in situ measurements for strain describe nanosecond diffraction evaluated using two planes, (hkl) and (h′k′l′), both in the same crystallographic phase. Diffraction from Al, Ni, Na, and Invar quantifies the compression axial strains in these materials: The compression axial ratios are 0.65, 1.05, 0.88, and 1.58 at pressures of 291, 402, 409, and 367 GPa for the respective materials. Crystal structure transformations with homogeneous pressurized stresses, mandating equal normal strains, should not be anticipated to agree with heterogeneous, uniaxially strained, and sheared crystalline phases. Measurements support in-plane strains increasing with pressure, p , in fcc and hcp aluminum as ε 22 = −0.21 p /TPa.

Alloys↗

Developing time-resolved x-ray diffraction diagnostics at the National Ignition Facility (invited)

As part of a program to measure phase transition timescales in materials under dynamic compression, we have designed new x-ray imaging diagnostics to record multiple x-ray diffraction measurements during a single laser-driven experiment. Our design places several ns-gated hybrid CMOS (hCMOS) sensors within a few cm of a laser-driven target. The sensors must be protected from an extremely harsh environment, including debris, electromagnetic pulses, and unconverted laser light. Another key challenge is reducing the x-ray background relative to the faint diffraction signal. Building on the success of our predecessor (Target Diffraction In Situ), we implemented a staged approach to platform development. First, we built a demonstration diagnostic (Gated Diffraction Development Diagnostic) with two hCMOS sensors to confirm we could adequately protect them from the harsh environment and also acquire acceptable diffraction data. This allowed the team to quickly assess the risks and address the most significant challenges. Here, we also collected scientifically useful data during development. Leveraging what we learned, we recently developed a much more ambitious instrument (Flexible Imaging Diffraction Diagnostic for Laser Experiments) that can field up to eight hCMOS sensors in a flexible geometry and participate in back-to-back shots at the National Ignition Facility (NIF). The design also allows for future iterations, such as faster hCMOS sensors and an embedded x-ray streak camera. The enhanced capabilities of the new instrument required a much more complex design, and the unexpected issues encountered on the first few shots at NIF remind us that complexity has consequences. Our progress in addressing these challenges is described herein, as is our current focus on improving data quality by reducing x-ray background and quantifying the uncertainties of our diffraction measurements.

36 MATERIALS SCIENCE↗

Simultaneous x-ray diffraction measurements of nine pressure calibrants to 140 GPa

Accurate pressure calibration is fundamental to quantitative high-pressure science, yet inconsistencies among widely used secondary pressure scales persist. In this work, we report simultaneous synchrotron x-ray diffraction meatogether in diamond anvil cells to 140 GPa. This simultaneous-measurement strategy minimizes transitive errors and run-to-run inconsistencies inherent to paired-measurement approaches, yielding direct experimental volume-volume (V-V) relations among the calibrants. These V-V relations link the compression state of each phase to that of every other phase measured in the same experiment. By anchoring these V-V relations to the reduced 300 K equation of state (EOS) of copper derived from ramp-compression measurements, we derive an internally consistent set of Cu-referenced pressure scales via Vinet EOS fits. Because the primary experimental result is the V-V dataset, it provides an EOS-independent constraint that can be rereferenced if primary standards are revised. The dataset further enables a direct experimental cross-check of consistency between the adopted reduced 300 K Cu EOS and the corresponding reduced 300 K ramp-derived EOSs for Pt, Au, Ta, and hcp-Fe under a fixed V-V constraint. The residuals quantify small, material-dependent mismatches between each phase EOS and the Cu reference EOS.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Field and Model Data Associated with the Manuscript “Drivers of Streamflow Intermittency in Humid Regions: 1. Evaluating Above- and Below-ground Controls of Flow Persistence in a Forested Catchment”

This package contains field data, modeling files, and scripts supporting the investigation of the drivers of streamflow intermittency in a forested catchment. It includes the field data collected from electrical resistivity tomography (ERT) surveys, ground penetrating radar (GPR), continuous self-potential (SP) monitoring, electromagnetic (EM) imaging, groundwater and stilling well. In addition, it contains the data and results of the coupled water- and electrical-flow model developed using the COMSOL Multiphysics and Advanced Terrestrial Simulator (ATS), as well as software files and Jupyter notebooks used to process the data and generate figures in the manuscript submitted for peer review. The data archive is organized in the following directories: 1) Climate Includes hourly precipitation and daily evapotranspiration time series (2024 – 2025) provided as CSV files, alongside a text file detailing dataset units. 2) Coupled_model Contains two subfolders: Synthetic and Field_Application subfolder. Synthetic subfolder contains the ATS XML input script (can be opened using any code editor) for the four synthetic hydrological cases tested (Connected and gaining, Connected and losing, Disconnected and losing, and dry stream). It also includes other experimental cases to test the influence of precipitation and concentration gradient. For each synthetic case, the flow model simulation is executed using the ATS XML scripts and the included Python script (generate_data_set.py) to convert ATS output to COMSOL-ready input. COMSOL Multiphysics template (.mph can be opened with the commercial software COMSOL and requires a license) is executed using the ATS output data to simulate the potential field. It also includes the Synthetic_model_plot.ipynb (can be opened using any code editor) to visualize the SP result and generate manuscript figures. The data subfolder contains mesh files to run both the ATS (.exo and .stl files can be viewed using Paraview; .h5 files can be opened using HDFView software and h5py Python package) and COMSOL models. Field_Application subfolder contains two subfolders: ES_MDA_inversion and Final_Model. ES_MDA_inversion contains the Python script (.py can be opened using any code editor) and SP observation data used to run the Ensemble Smoother with Multiple Data Assimilation (ES-MDA) inversion sequence to get the optimal model parameters. The Final_model subfolder contains the ATS XML input scripts, data files, output data for the two SP sites. The same workflow steps outlined for the Synthetic subfolder apply here. It also contains the Jupyter notebook (Plot_final_calib.ipynb) to visualize the results of the modeled SP, stream-groundwater exchange and moisture content. 3) Discharge Includes the electrical conductivity (EC) time series (provided as CSV files) from salt slug injections. It also includes the Jupyter notebook (Discharge_process.ipynyb) used to estimate discharge. All discharge measurements collated into rating_curve_processed.csv 4) EM Contains the CSV file of the EM data from the DUALEM-42, including spatial coordinates (x, y, z), apparent conductivity, and in-phase measurements at 2 m coil separations for horizontal coplanar (HCP) and perpendicular (PRP) geometries. 5) ERT Contains raw resistivity data (provided as CSV files), spatial location of each of the electrodes (provided as CSV files), and files used for the resistivity inversion (.resipy can be opened with the open-source ResIPy software). 6) GPR Includes GPR field datasets collected at 100 MHz and 250 MHz antenna frequencies, along with the processing/interpretation project file (GPR_process.gpz can be viewed using EKKO_Project 6, a commercial software by Sensors & Software that requires a license). 7) Slug_test Includes the slug test data at all the groundwater wells provided as CSV files, as well as the Jupyter notebook (Slug_test.ipynb) for calculating hydraulic conductivity. 8) SP Contains the SP data collected in field at the two SP sites (one in the perennial reach and the other in the intermittent reach), provided as DAT files. 9) Well_data Contains two subfolders: 1) Raw, which provides unprocessed pressure, electrical conductivity and temperature timeseries downloaded from the loggers in all the groundwater and stilling wells, and 2) Processed, which contains sorted, QA/QC timeseries data for each well. The data archive also contains data_process.ipynb, a Jupyter notebook used for field data analysis and generating figures (plotting well, SP, climate, and discharge data, as well as calculating head gradient at sites with nested groundwater wells). It also includes DTW.ipynb, a Jupyter notebook containing the code for the dynamic time warping (DTW) with sliding window to evaluate SP signal synchronicity.

ATS↗

Cross-polarized common-path temporal interferometry for high-sensitivity strong-field ionization measurements

Absolute density measurements of low-ionization-degree or low-density plasmas ionized by lasers are very important for understanding strong-field physics, atmospheric propagation of intense laser pulses, Lidar etc. A cross-polarized common-path temporal interferometer using balanced detection was developed for measuring plasma density with a sensitivity of ∼0.6 mrad, equivalent to a plasma density-length product of ∼2.6 × 10 13 cm −2 if using an 800 nm probe laser. By using this interferometer, we have investigated strong-field ionization yield versus intensity for various noble gases (Ar, Kr, and Xe) using 800 nm, 55 fs laser pulses with both linear (LP) and circular (CP) polarization. The experimental results were compared to the theoretical models of Ammosov-Delone-Krainov (ADK) and Perelomov-Popov-Terent’ev (PPT). We find that the measured phase change induced by plasma formation can be explained by the ADK theory in the adiabatic tunneling ionization regime, while PPT model can be applied to all different regimes. We have also measured the photoionization and fractional photodissociation of molecular (MO) hydrogen. By comparing our experimental results with PPT and MO-PPT models, we have determined the likely ionization pathways when using three different pump laser wavelengths of 800 nm, 400 nm, and 267 nm.

47 OTHER INSTRUMENTATION↗

EPCAPE-PT-LANL Measurements: PM Modulair 1

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Quant-AQ MODULAIR. Mounted external to the instrument container, near the GCVI inlet. The MODULAIR™ air quality monitor uses the same patent-pending PM sensor found in the MODULAIR™-PM and adds four gas-phase measurements (CO, NO, NO2, and O3) to provide an all-in-one solution. Files data_10sec_Quant_Gas.csv, data_10min_Quant_Gas.csv Header: - CO[ppb]: Concentration of carbon monoxide (CO) measured at the time of sampling, expressed in parts per billion (ppb) - NO[ppb]: Concentration of nitric oxide (NO) measured at the time of sampling, expressed in parts per billion (ppb). - O3[ppb]: Concentration of ozone (O3) measured at the time of sampling, expressed in parts per billion (ppb). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage. Files data_10sec_Quant_PM.csv, data_10min_Quant_PM.csv Header: - PM1[ug/m3]: Concentration of particulate matter with a diameter of 1 micron or less, measured in micrograms per cubic meter (µg/m³). - PM2-5[ug/m3]: Concentration of particulate matter with a diameter of 2.5 microns or less measured in micrograms per cubic meter (µg/m³). - PM10[ug/m3]: Concentration of particulate matter with a diameter of 10 microns or less, measured in micrograms per cubic meter (µg/m³). - Temperature[C]: The ambient temperature at the time of the measurement, expressed in degrees Celsius. - RelativeHumidity[%]: The relative humidity at the time of the measurement, expressed as a percentage.

54 ENVIRONMENTAL SCIENCES↗

Analytically differentiable metrics for phase stability

Here, in this work, a long-established but sparsely documented method of obtaining semi-analytic derivatives of thermodynamic properties with respect to equilibrium conditions is briefly reviewed and rigorously derived. This procedure is then leveraged to construct general forms of derivatives of the residual driving force, a metric for measuring phase stability used in CALPHAD model optimization, with respect to overall system and individual phase compositions. Applied examples – calculating heat capacity in the Al-Fe system, thermodynamic factors in the Nb-V-W system, and residual driving force derivatives in the Ni-Ti system – demonstrate the versatility, accuracy, and extensibility of this method. Using the developed method, residual driving force gradients can be applied directly in CALPHAD model optimizers, as well as in materials design frameworks, to identify regions of phase stability with an efficient, gradient-based approach.

36 MATERIALS SCIENCE↗

Materials design, synthesis, and transport properties of disordered rare-earth Zintl bismuthides with the anti -Th 3 P 4 structure type

The synthesis, structural elucidation, and transport properties of the extended series Ca 4–x RE x Bi 3 (RE = Y, La–Nd, Sm, Gd–Tm, and Lu; x ≈ 1) and Ca 4–x RE x Bi 3–δ Sb δ (RE = La, Ho, Er, and Lu; x ≈ 1, δ ≈ 1.5) are presented. Structural elucidation is based on single-crystal X-ray diffraction data and confirms the chemical drive of Ca4Bi3 with the cubic anti-Th 3 P 4 structure type (space group I4 ¯3d, no. 220, Z = 4) into a Zintl phase by the introduction of trivalent rare-earth atoms. The structure features complex bonding, heavy elements, and electron count akin to that of valence-precise semiconductors, making it an ideal target for thermoelectrics development. Introducing crystallographic site disorders at the cation site for the Ca 4–x RE x Bi 3 phase and both the cation and anion sites for the Ca 4–x RE x Bi 3–δ Sb δ phase brings about additional desirable characteristics for thermoelectric materials in the context of tuning knobs for lowering thermal conductivity. Electronic structure calculations of idealized Ca 3 YBi 3 and Ca 3 LaBi 3 compounds indicate the opening of indirect bandgaps at the Fermi level with magnitudes Eg = 0.38 eV and 0.57 eV, respectively. The electrical resistivity ρ(T) of some of the investigated phases measured on single crystals evolve in a metallic manner with magnitudes of order 1.4 mΩ cm near 500 K, thus supporting the notion of a degenerate semiconducting state, with the temperature dependence of the Seebeck coefficient α(T) suggesting the p-type behavior. Furthermore, the low electrical resistivity and the realization of a degenerate semiconducting state in the title phases present a window of opportunity for optimizing their carrier concentrations for enhanced thermoelectric performance.

36 MATERIALS SCIENCE↗

Achieving a near-ideal silicon crystal neutron interferometer using submicrometer fabrication techniques

Perfect-crystal neutron interferometry, which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be nuclear, electromagnetic, gravitational, or topological in nature. For a perfect-crystal interferometer to preserve coherence, the crystal must possess a high degree of dimensional tolerance as well as being relatively defect-free with minimal internal stresses. In the past, perfect-crystal neutron interferometers have been produced by a two-step process. First, a resin diamond wheel would be used to remove excess material and shape the interferometer. Afterword, the crystal would be etched to remove surface defects and elevate strains. This process has had limitations in terms of repeatability and in maximizing the final contrast, or fringe visibility, of the interferometer. We have tested various fabrication and post-fabrication techniques on a single perfect-crystal neutron interferometer and measured the interferometer's performance at each step. Here we report a robust, nonetching fabrication process with high final contrast. For the interferometer used in this work, we achieved contrasts of greater than 90% several times and ultimately finished with an interferometer that has 92% contrast and a uniform phase distribution. Published by the American Physical Society 2024

Huber, M. G. (ORCID:0000000237958445)↗

Online detection of airborne nanoparticle composition with mass spectrometry: Recent advances, challenges, and opportunities

Airborne nanoparticles are receiving growing attention due to their impacts on human health, air quality, and climate. Additionally, there are increasing applications of aerosol-based nanotechnology. Real-time measurement of airborne nanoparticle composition is challenging due to their small masses and the difficulties in effectively separating them from larger particles. Custom-built instruments based on mass spectrometry have been developed for nanoparticle composition, including thermal desorption-based, laser-based, and solution-based techniques. They have significantly promoted the understanding of airborne nanoparticles in the last two decades. However, they are affected by molecular fragmentation, lack of mass-resolving power, incomplete species detection, and difficulties in directly comparing to gas-phase measurements. Recent developments in atmospheric mass spectrometry provide possible solutions. Here, this review presents the potential application of these new advances to real-time measurements of the molecular nanoparticle composition and discusses the associated challenges. Such measurements present opportunities for a more comprehensive view of airborne nanoparticles and their impacts.

47 OTHER INSTRUMENTATION↗