Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Peaker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

36 records · Page 2

Design of a Compact Dry Cooler With an Aluminum Heat Exchanger Core for a Supercritical CO2 Power Cycle Is Evaluated for a Concentrating Solar Power Application

Abstract As the supercritical CO2 power cycle develops and the component technologies mature, there is still a need to reduce the associated capital and operating costs to maintain a competitive levelized cost of electricity (LCOE) in order to enter the market. When considering concentrating solar power (CSP) coupled with an sCO2 power block and sensible thermal storage, the technology presents a clean source for utility-scale power generation to support baseload or peak-load electrical demand. However, the LCOE of the technology is still considered higher than the competing technologies and should be reduced to better compete in the market; 2030 targets for dispatchable solar plants are 5¢/kWh for baseload CSP and 10¢/kWh for peaker plants, as set by the United States Department of Energy. In response to this need, this study is targeting improvements in the power cycle precooler to reduce power block contribution to LCOE. This study considers a dry cooler, as CSP plants are sensitive to water consumption because many installations are slated for remote or arid locations where solar irradiance is very high, but water is scarce. Furthermore, the power block footprint for an sCO2 system is quite compact, especially as compared to a steam cycle. Therefore, there is interest in installing a more compact dry cooler that is proportional to the reduced footprint sCO2 power block, while conventional dry coolers are an order of magnitude larger. The competing goals of size, performance, and cost were considered in this study to develop a compact dry cooler that can easily be packaged with the power block, significantly reducing the installation and transport cost compared to the current state of the art, while maintaining or improving upon the heat transfer performance and impact on plant LCOE. This paper details the high-level findings of a large dry cooler sensitivity study for design point selection, design of the compact dry cooler, expected year-round performance for the dry cooler and the power cycle, and the predicted LCOE for a 30-year plant life. It was found that an aluminum heat exchanger core can be suitably designed to meet the pressure and temperature requirements for a precooler in an sCO2 recompression Brayton cycle. The dry cooler assembly was found to have improved heat transfer performance, allowing for increased cycle efficiencies and a reduced plant LCOE. When coupled with a centrifugal blower and compact transition duct, the dry cooler assembly was able to reduce the installation footprint by over 50%.

14 SOLAR ENERGY↗

Identifying and Overcoming Critical Barriers to Widespread Second Use of PEV Batteries

Both the market penetration of plug-in electric vehicles (PEVs) and deployment of grid-connected energy storage systems are presently restricted by the high cost of batteries. Battery second use (B2U) strategies--in which a single battery first serves an automotive application, then is redeployed into a secondary market--could help address both issues by reducing battery costs to the primary (automotive) and secondary (electricity grid) users. This study investigates the feasibility of and major barriers to the second use of lithium-ion PEV batteries by posing and answering the following critical B2U questions: 1. When will used automotive batteries become available, and how healthy will they be? 2. What is required to repurpose used automotive batteries, and how much will it cost? 3. How will repurposed automotive batteries be used, how long will they last, and what is their value? Advanced analysis techniques are employed that consider the electrical, thermal, and degradation response of batteries in both the primary (automotive) and secondary service periods. Second use applications are treated in detail, addressing operational requirements, economic value, and market potential. The study concludes that B2U is viable and could provide considerable societal benefits due to the large possible supply of repurposed automotive batteries and substantial remaining battery life following automotive service. However, the only identified secondary market large enough to consume the supply of these batteries (utility peaker plant replacement) is expected to be a low margin market, and thus B2U is not expected to affect the upfront cost of PEVs.

25 ENERGY STORAGE↗

ARRA Energy Storage Demonstration Projects: Lessons Learned and Recommendations

The American Recovery and Reinvestment Act (ARRA) of 2009 (Recovery Act) provided funding for 16 energy storage demonstration projects. The projects ranged in scope from feasibility studies and technology demonstrations to full-scale, operational energy storage plants. This investment had a significant positive impact on the grid-connected energy storage industry. The goal of this report is to summarize the lessons learned from the ARRA projects, and to make recommendations for future Department of Energy (DOE) investments. Information for this report primarily came from three sources: a questionnaire and interview with each project team; DOE energy storage program peer review presentations; and DOE reports required as part of the ARRA project. Some lessons learned were common to many projects. Development of standards, codes and protocols specific to energy storage systems will mitigate uncertainty over code compliance, streamline permitting, and should be a priority (especially related to safety). Removal of regulatory barriers that preclude optimal operation of an energy storage system with multiple applications would immediately enable further deployment (e.g., FERC standards preclude the marketing department from reliability activities). Maturity of the approach to monetization varies substantially between applications with frequency regulation as an ancillary service leading other applications. Finally, developers focused on ramp mitigation and time shifting envision a reference plant. This reference plant would scale up from the current demonstration systems and would lead to the deployment of 50 MW-scale peaker plants.

25 ENERGY STORAGE↗

Regulators’ Financial Toolbox: Virtual Power Plants Summary

On June 21, 2023, NARUC’s Center for Partnerships & Innovation (CPI) and the NASEO-NARUC GridInteractive Efficient Buildings (GEB) Working Group co-hosted a Regulators’ Financial Toolbox Webinar on the topic of virtual power plants (VPPs). The webinar featured opening remarks from moderator Commissioner Cecile Fraser of the Public Utilities Commission of Massachusetts and presentations from Ryan Hledik, Principal, The Brattle Group; Brenda Chew, Director of Product Management, Virtual Peaker; and Franco Albi, Director of Regional Integration, Portland General Electric.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Double-Peaked Profiles: Ubiquitous Signatures of Disks in the Broad Emission Lines of Active Galactic Nuclei

Broad (∼10,000 km s{sup −1}), double-peaked emission-line profiles of Balmer lines emitted by active galactic nuclei (AGN) are thought to originate in the outer parts of an accretion disk surrounding a nuclear supermassive black hole (SMBH), at ∼1000 gravitational radii, and are most frequently observed in the nuclear spectra of low-luminosity AGN (LLAGN) and radio galaxies. In the present paper we argue that broad double-peaked profiles are present also in the spectra of other type 1 AGN, such as Seyfert 1 galaxies, suggesting that the inner part of the broad-line region (BLR) is also the outer part of the accretion disk. We use the Palomar spectral survey of nearby galaxies to show that the only difference between Seyfert 1 BLR line profiles and “bona fide” double-peakers is that, in most cases, besides a disk component, we need an additional Gaussian component attributed to nondisk clouds. The recognition that the inner and most variable part of the BLR has a disk geometry suggests that the factor f in the expression to obtain the SMBH mass in type 1 AGN, M{sub BH}=f(R{sub BLR}ΔV{sup 2}/G), is f=1/sin{sup 2}i for the disk-dominated sources. Our median i = 27° implies f = 4.5, very close to the most recent value of f = 4.3 ± 1.05, obtained from independent studies. We derive a relation between f and the FWHM of the broad profile that may help to reduce the uncertainties in the SMBH mass determinations of AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-temperature fuel cell systems for commercial airplane auxiliary power.

This presentation briefly describes the ongoing study of fuel cell systems on-board a commercial airplane. Sandia's current project is focused on Proton Exchange Membrane (PEM) fuel cells applied to specific on-board electrical power needs. They are trying to understand how having a fuel cell on an airplane would affect overall performance. The fuel required to accomplish a mission is used to quantify the performance. Our analysis shows the differences between the base airplane and the airplane with the fuel cell. There are many ways of designing a system, depending on what you do with the waste heat. A system that requires ram air cooling has a large mass penalty due to increased drag. The bottom-line impact can be expressed as additional fuel required to complete the mission. Early results suggest PEM fuel cells can be used on airplanes with manageable performance impact if heat is rejected properly. For PEMs on aircraft, we are continuing to perform: (1) thermodynamic analysis (investigate configurations); (2) integrated electrical design (with dynamic modeling of the micro grid); (3) hardware assessment (performance, weight, and volume); and (4) galley and peaker application.

30 DIRECT ENERGY CONVERSION↗

Correlated Synthetic Time Series Generation using Fourier and ARMA

As the contribution of renewable energy grows in electricity markets, the complexity nuclear’s place within the energy mix increases, and likewise the need for robust simulation techniques. While decades of wind, solar, and demand pro- files can sometimes be obtained, this is too few samples to provide a statistically meaningful analysis of a system with baseload, peaker, and renewable generation. Synthetic time series generation presents itself as a suitable methodology to meet this need. One approach for synthetic series generation is training a model using Fourier series decomposition for seasonal patterns and Auto-Regressive Moving Average models (ARMA) to describe time-correlated statistical noise about the seasonal patterns. When combined, the Fourier plus ARMA (FARMA) model has been shown to provide an infinite set of independent, identically-distributed sample time series with the same statistical properties as the original data [1]. When considering an energy mix with renewable electricity production, several time series of energy, grid, and weather measurements are needed for each synthetic year modeled to statistically comprehend the efficiency of any given energy mix. These cannot be considered independent series in a given synthetic year. To capture and reproduce the correlations that might exist in the measured histories, the ARMA can further be extended as a Vector ARMA (VARMA). In the VARMA algorithm, covariance in statistical noise is captured both within a history as part of the autoregressive moving average, and with respect to the other variables in the time series. In this work the implementation of the Fourier VARMA in the RAVEN uncertainty quantification and risk analysis software framework [2] is presented, along with examples of correlated synthetic history generation.

97 MATHEMATICS AND COMPUTING↗

Exceptional gettering response of epitaxially grown kerfless silicon

The bulk minority-carrier lifetime in p- and n-type kerfless epitaxial (epi) crystalline silicon wafers is shown to increase >500× during phosphorus gettering. We employ kinetic defect simulations and microstructural characterization techniques to elucidate the root cause of this exceptional gettering response. Simulations and deep-level transient spectroscopy (DLTS) indicate that a high concentration of point defects (likely Pt) is “locked in” during fast (60 °C/min) cooling during epi wafer growth. The fine dispersion of moderately fast-diffusing recombination-active point defects limits as-grown lifetime, but can also be removed during gettering, confirmed by DLTS measurements. Synchrotron-based X-ray fluorescence microscopy indicates metal agglomerates at structural defects, yet the structural defect density is sufficiently low to enable high lifetimes. Consequently, after phosphorus diffusion gettering, epi silicon exhibits a higher lifetime than materials with similar bulk impurity contents but higher densities of structural defects, including multicrystalline ingot and ribbon silicon materials. Device simulations suggest a solar-cell efficiency potential of this material >23%.

DLTS↗

Laplace-Transform Deep-Level Spectroscopy Characterization of the Intrinsic and Deep-Level States in Self-Assembled InAs Quantum-Dot Structures

The electron emission from the intrinsic and deep-level states in self-assembled InAs/GaAs quantum-dot structures is probed using the Laplace-transform deep-level transient spectroscopy. The technique shows sufficient resolution to resolve electron emission from the singly and doubly occupied QD s states. By applying an appropriate set of voltage pulses across the Schottky-diode structure, we identify the electron distribution profile in the quantum-dot intrinsic states.

36 MATERIALS SCIENCE↗

Donor levels of the divacancy-oxygen defect in silicon

The elimination of divacancies (V{sub 2}) upon isochronal and isothermal annealing has been studied in oxygen-rich p-type silicon by means of deep level transient spectroscopy (DLTS) and high resolution Laplace DLTS. Divacancies were introduced into the crystals by irradiation with 4 or 6 MeV electrons. The temperature range of the divacancy disappearance was found to be 225-300 °C upon 30 min isochronal annealing in the samples studied. A clear anti-correlation between the disappearance of V{sub 2} and the appearance of two hole traps with activation energies for hole emission of 0.23 eV and 0.08 eV was observed. It is argued that these traps are related to the first and second donor levels of the divacancy-oxygen (V{sub 2}O) complex, respectively. Significant electric field enhancement of the hole emission from the second donor level of the V{sub 2}O center occurred in the diodes studied. It is shown that in the range of electric field from 4 × 10{sup 3} to 1.2 × 10{sup 4} V/cm the emission enhancement is associated with phonon-assisted tunnelling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Titanium in silicon: Lattice positions and electronic properties

Secondary ion mass spectroscopy (SIMS) and deep level transient spectroscopy measurements were carried out on Czochralski (Cz)- and float-zone-grown (FZ) Si crystals, which were implanted with Ti ions and annealed in the temperature range 600–900 °C. The electrical behavior of Ti atoms is found to be different in Cz- and FZ-Si annealed at 650 °C, although the Ti SIMS profiles are similar. It is argued that interstitial Ti atoms (Ti{sub i}) in FZ-Si crystals interact with implantation-induced vacancies and take a substitutional position (Ti{sub s}). No energy levels which can be assigned to Ti{sub s} have been detected in this work or in previous experimental literature. However, previous calculations suggest that Ti{sub s} is a deep acceptor in Si. We show from density functional calculations that by taking proper account of interactions within the d-shell of the Ti impurity the electronic structure of Ti{sub s} has no levels in the band gap. The calculations show that Ti{sub i} is more energetically favorable than Ti{sub s} and that Ti{sub i} binds more strongly to the silicon vacancy than interstitial oxygen does, explaining the observed differences between FZ- and Cz-irradiated materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evidence for an iron-hydrogen complex in p-type silicon

Interactions of hydrogen with iron have been studied in Fe contaminated p-type Czochralski silicon using capacitance-voltage profiling and deep level transient spectroscopy (DLTS). Hydrogen has been introduced into the samples from a silicon nitride layer grown by plasma enhanced chemical vapor deposition. After annealing of the Schottky diodes on Si:Fe + H samples under reverse bias in the temperature range of 90–120 °C, a trap has been observed in the DLTS spectra which we have assigned to a Fe-H complex. The trap is only observed when a high concentration of hydrogen is present in the near surface region. The trap concentration is higher in samples with a higher concentration of single interstitial Fe atoms. The defect has a deep donor level at E{sub v} + 0.31 eV. Direct measurements of capture cross section of holes have shown that the capture cross section is not temperature dependent and its value is 5.2 × 10{sup −17} cm{sup 2}. It is found from an isochronal annealing study that the Fe-H complex is not very stable and can be eliminated completely by annealing for 30 min at 125 °C.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Trivacancy and trivacancy-oxygen complexes in silicon: Experiments and ab initio modeling

A center from the family of 'fourfold coordinated (FFC) defects', previously predicted theoretically, has been experimentally identified in crystalline silicon. It is shown that the trivacancy (V{sub 3}) in Si is a bistable center in the neutral charge state, with a FFC configuration lower in energy than the (110) planar one. V{sub 3} in the planar configuration gives rise to two acceptor levels at 0.36 and 0.46 eV below the conduction band edge (E{sub c}) in the gap, while in the FFC configuration it has trigonal symmetry and an acceptor level at E{sub c}-0.075 eV. From annealing experiments in oxygen-rich samples, we also conclude that O atoms are efficient traps for mobile V{sub 3} centers. Their interaction results in the formation of V{sub 3}O complexes with the first and second acceptor levels at E{sub c}-0.46 eV and E{sub c}-0.34 eV. The overall picture, including structural details, relative stability, and electrical levels, is accompanied and supported by ab initio modeling studies.

36 MATERIALS SCIENCE↗

Controlling Air Conditioners for Frequency Regulation: A Real-World Example

Even though thermostatically controlled loads like air conditioners present a great potential for providing ancillary services to the electric power grid, the practical challenges associated with their real-time coordination have not received the necessary attention. In this work, we present a nondisruptive load control application, specifically, we demonstrate how real residential air conditioners can provide frequency regulation. Aggregate power adjustment is achieved by modifying the ON/OFF modes of the air conditioners. To account for both single and multi-zone houses, we extend the currently available techniques and develop an approach that can be used for controlling aggregations that include both types of houses. A discussion of the practical challenges encountered in our field experiments is provided, along with the hardware and software approaches we developed to circumvent them. Here, we argue that limitations of current thermostat APIs introduce significant challenges and are an impediment to widespread adoption of fast load control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Path to SunShot. Advancing Concentrating Solar Power Technology, Performance, and Dispatchability

This report examines the remaining challenges to achieving the competitive concentrating solar power (CSP) costs and large-scale deployment envisioned under the U.S. Department of Energy's SunShot Initiative. Although CSP costs continue to decline toward SunShot targets, CSP acceptance and deployment have been hindered by inexpensive photovoltaics (PV). However, a recent analysis found that thermal energy storage (TES) could increase CSP's value--based on combined operational and capacity benefits--by up to 6 cents/kWh compared to variable-generation PV, under a 40% renewable portfolio standard in California. Thus, the high grid value of CSP-TES must be considered when evaluating renewable energy options. An assessment of net system cost accounts for the difference between the costs of adding new generation and the avoided cost from displacing other resources providing the same level of energy and reliability. The net system costs of several CSP configurations are compared with the net system costs of conventional natural-gas-fired combustion-turbine (CT) and combined-cycle plants. At today's low natural gas prices and carbon emission costs, the economics suggest a peaking configuration for CSP. However, with high natural gas prices and emission costs, each of the CSP configurations compares favorably against the conventional alternatives, and systems with intermediate to high capacity factors become the preferred alternatives. Another analysis compares net system costs for three configurations of CSP versus PV with batteries and PV with CTs. Under current technology costs, the least-expensive option is a combination of PV and CTs. However, under future cost assumptions, the optimal configuration of CSP becomes the most cost-effective option.

14 SOLAR ENERGY↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Asheville, North Carolina: Reducing Electricity Demand through Building Programs & Policies (City Energy: From Data to Decisions)

This fact sheet "Asheville, North Carolina: Reducing Electricity Demand through Building Programs & Policies" explains how the City of Asheville used data from the U.S. Department of Energy's Cities Leading through Energy Analysis and Planning (Cities-LEAP) and the State and Local Energy Data (SLED) programs to inform its city energy planning. It is one of ten fact sheets in the "City Energy: From Data to Decisions" series.

buildings↗