3D Endoscope to Boost Safety, Cut Cost of Surgery

Researchers at the Jet Propulsion Laboratory worked with the brain surgeon who directs the Skull Base Institute in Los Angeles to create the first endoscope fit for brain surgery and capable of producing 3D video images. It is also the first to be able to steer its lens back and forth. These improvements to visibility are expected to improve safety, speeding patient recovery and reducing medical costs.

Source record↗

The Impact of Variability in Patient Exposure During Premarket Clinical Development on Postmarket Safety Outcomes

We characterized the size of the premarket safety population for 278 small-molecule new molecular entities (NMEs) and 61 new therapeutic biologics (NTBs) approved by the US Food and Drug Administration (FDA) between October 1, 2002, and December 31, 2014, evaluating the relationship of premarket safety population size to regulatory characteristics and postmarket safety outcomes. The median size of the safety population was 1,044, and was lower for NTBs than NMEs (median: 920 vs. 1,138, P = 0.04), orphan products than nonorphan products (393 vs. 1,606, P < 0.001), and for products with fast-track designation (617 vs. 1,455, P < 0.001), priority review (630 vs. 1,735, P < 0.001), and accelerated approval (475 vs. 1,164, P < 0.001), than products without that designation. The median number of postmarket safety label updates and issues added to the label were higher with larger premarket exposure among nonorphan products, but not among orphan products. Products with accelerated approval using a surrogate end point had a higher median number of safety issues added to the label than those with full approval, but this did not vary with the size of the safety population; fast-track and priority review were not associated with the number of safety issues added to the label. Here, a smaller safety population size was associated with a longer time to first safety outcome for nonorphan products but not orphan products. For orphan and nonorphan products combined, smaller premarket safety population size is not associated with the number or timing of postmarket safety outcomes, regardless of expedited program participation.

60 APPLIED LIFE SCIENCES↗

Hydrostatic Hyperbaric Chamber Ventilation System

The hydrostatic hyperbaric chamber (HHC) represents the merger of several technologies in development for NASA aerospace applications, harnessed to directly benefit global health. NASA has significant experience developing composite hyperbaric chambers for a variety of applications. NASA also has researched the application of water-filled vessels to increase tolerance of acceleration forces. The combination of these two applications has resulted in the hydrostatic chamber, which has been conceived as a safe, affordable means of making hyperbaric oxygen therapy (HBOT) available in the developing world for the treatment of a variety of medical conditions. Specifically, HBOT is highly-desired as a possibly curative treatment for Buruli Ulcer, an infectious condition that afflicts children in sub-Saharan Africa. HBOT is simply too expensive and too dangerous to implement in the developing world using standard equipment. The HHC technology changes the paradigm. The HHC differs from standard hyperbaric chambers in that the majority of its volume is filled with water which is pressurized by oxygen being supplied in the portion of the chamber containing the patient s head. This greatly reduces the amount of oxygen required to sustain a hyperbaric atmosphere, thereby making the system more safe and economical to operate. An effort was taken to develop an HHC system to apply HBOT to children that is simple and robust enough to support transport, assembly, maintenance and operation in developing countries. This paper details the concept for an HHC ventilation and pressurization system to provide controlled pressurization and adequate washout of carbon dioxide while the subject is enclosed in the confined space during the administration of the medical treatment. The concept took into consideration operational complexity, safety to the patient and operating personnel, and physiological considerations. The simple schematic, comprised of easily acquired commercial hardware, supports sustainability.

Sarguisingh, Miriam J.↗

Hydrostatic Hyperbaric Chamber Ventilation System

The hydrostatic hyperbaric chamber (HHC) represents the merger of several technologies in development for NASA aerospace applications, harnessed to directly benefit global health. NASA has significant experience developing composite hyperbaric chambers for a variety of applications, including the treatment of medical conditions. NASA also has researched the application of water-filled vessels to increase tolerance of acceleration forces. The combination of these two applications has resulted in the hydrostatic chamber, which has been conceived as a safe, affordable means of making hyperbaric oxygen therapy available in the developing world for the treatment of a variety of medical conditions. Specifically, hyperbaric oxygen therapy is highly-desired as a possibly curative treatment for Buruli Ulcer, an infectious condition that afflicts children in sub-Saharan Africa. Hyperbaric oxygen therapy is simply too expensive and too dangerous to implement in the developing world using standard equipment. The hydrostatic hyperbaric chamber technology changes the paradigm. The HHC differs from standard hyperbaric chambers in that the majority of its volume is filled with water which is pressurized by oxygen being supplied in the portion of the chamber containing the patient s head. This greatly reduces the amount of oxygen required to sustain a hyperbaric atmosphere, thereby making the system more safe and economical to operate. An effort was taken to develop an HHC system to apply HBOT to children that is simple and robust enough to support transport, assembly, maintenance and operation in developing countries. This paper details the concept for an HHC ventilation and pressurization system that will provide controlled pressurization of the system, and provide adequate washout of carbon dioxide while the subject is enclosed in the confined space during the administration of the medical treatment. The concept took into consideration operational complexity, safety to the patient and operating personnel, and physiological considerations. The simple schematic, comprised of easily acquired commercial hardware, supports sustainability.

Sargusingh, Miriam M.↗

Extrapolation of Efficacy from Adults to Pediatric Patients of Drugs for Treatment of Partial Onset Seizures: A Regulatory Perspective

The US Food and Drug Administration (FDA) has concluded that the efficacy of drugs approved for the treatment of partial onset seizures (POS) in adults can be extrapolated to pediatric patients 1 month of age and above and that independent efficacy trials in this pediatric population are no longer needed. This paper focuses on the dosing, pharmacokinetic (PK), exposure‐response, and clinical information that were leveraged from the approved drugs for the treatment of POS to conduct analyses that supported extrapolation of efficacy in pediatric patients. Clinical data from trials for eight drugs (levetiracetam, oxcarbazepine, topiramate, lamotrigine, gabapentin, perampanel, tiagabine, and vigabatrin) approved in both adults and pediatric patients for the treatment of POS were analyzed. Comparisons of exposures at approved doses, placebo response, and model‐based exposure‐response relationships were performed. Based on disease similarity, similar response to intervention, and similar exposure‐response relationships in adults and pediatric patients, it was concluded that extrapolation of efficacy in pediatric patients aged 1 month and above is acceptable. PK analysis to determine pediatric dose and regimens that provide drug exposure similar to that known to be effective in adult patients with POS will be required, along with long‐term open‐label safety data in pediatric patients.

Pharmacology & Pharmacy↗

The MHC Associated Peptide Proteomics assay is a useful tool for the non-clinical assessment of immunogenicity

The propensity of therapeutic proteins to elicit an immune response, poses a significant challenge in clinical development and safety of the patients. Assessment of immunogenicity is crucial to predict potential adverse events and design safer biologics. In this study, we employed MHC Associated Peptide Proteomics (MAPPS) to comprehensively evaluate the immunogenic potential of re-engineered variants of immunogenic FVIIa analog (Vatreptacog Alfa). Our finding revealed the correlation between the protein sequence affinity for MHCII and the number of peptides identified in a MAPPS assay and this further correlates with the reduced T-cell responses. Moreover, MAPPS enable the identification of “relevant” T cell epitopes and may contribute to the development of biologics with lower immunogenic potential.

59 BASIC BIOLOGICAL SCIENCES↗

Safety Margins for the Delineation of the Left Anterior Descending Artery in Patients Treated for Breast Cancer

Cardiac toxicity after breast cancer (BC) radiation therapy is partly due to the large radiation doses to coronary arteries. The left anterior descending artery (LAD) is particularly exposed. A first step in achieving robust dose constraints to the LAD during treatment planning is homogeneous delineation based on guidelines. LAD delineation can be problematic due to heart movements. The aim of the study was to establish a safety margin for delineation of the LAD in patients with BC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Informing selection of drugs for COVID-19 treatment through adverse events analysis

Coronavirus disease 2019 (COVID-19) is an ongoing pandemic and there is an urgent need for safe and effective drugs for COVID-19 treatment. Since developing a new drug is time consuming, many approved or investigational drugs have been repurposed for COVID-19 treatment in clinical trials. Therefore, selection of safe drugs for COVID-19 patients is vital for combating this pandemic. Our goal was to evaluate the safety concerns of drugs by analyzing adverse events reported in post-market surveillance. We collected 296 drugs that have been evaluated in clinical trials for COVID-19 and identified 28,597,464 associated adverse events at the system organ classes (SOCs) level in the FDA adverse events report systems (FAERS). We calculated Z-scores of SOCs that statistically quantify the relative frequency of adverse events of drugs in FAERS to quantitatively measure safety concerns for the drugs. Analyzing the Z-scores revealed that these drugs are associated with different significantly frequent adverse events. Our results suggest that this safety concern metric may serve as a tool to inform selection of drugs with favorable safety profiles for COVID-19 patients in clinical practices. Caution is advised when administering drugs with high Z-scores to patients who are vulnerable to associated adverse events.

59 BASIC BIOLOGICAL SCIENCES↗

Should All Low-risk Patients Now Be Considered for TAVR? Operative Risk, Clinical, and Anatomic Considerations

Purpose of Review: This article reviews the current data on TAVR in low-risk patients with severe, symptomatic aortic stenosis, highlights the results of the recently published Medtronic Low Risk Randomized Study and PARTNER 3 trials, and describes specific clinical, anatomic, and procedural considerations regarding the optimal treatment choice in this population. Recent Findings: In low-risk patients, the Medtronic Low Risk Randomized Study demonstrated TAVR to be non-inferior to surgery with respect to the composite endpoint of death or disabling stroke while PARTNER 3 trial proved TAVR to be superior to surgery with regard to the composite endpoint of death, stroke, or rehospitalization. Summary: Recent trials demonstrate the safety and efficacy of TAVR in low-risk patients and have led to an FDA indication for the use of TAVR in these patients. However, the lack of long-term data on the rate of transcatheter valve deterioration in the younger population, higher incidence of paravalvular leak and pacemaker implantation following TAVR, along with certain intrinsic anatomic factors remain potential challenges to generalize TAVR in all low surgical risk patients. We describe specific clinical, anatomic, and procedural considerations regarding the optimal treatment choice for low-risk patients with severe, symptomatic AS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A short hepatitis C virus NS5A peptide expression by AAV vector modulates human T cell activation and reduces vector immunogenicity

Viral vector-mediated gene therapies have the potential to treat many human diseases; however, host immune responses against the vector and/or the transgene pose a safety risk to the patients and can negatively impact product efficacy. Thus, novel strategies to reduce vector immunogenicity are critical for the advancement of these therapies. T cell activation (TCA) is required for the development of immune responses during gene therapy. We hypothesized that modulation of TCA by incorporating a novel viral immunomodulatory factor into a viral vector may reduce unwanted TCA and immune responses during gene therapy. To test this hypothesis, we identified an immunomodulatory domain of the hepatitis C virus (HCV) NS protein 5A (NS5A) protein and studied the effect of viral vectors expressing NS5A peptide on TCA. Lentiviral vector-mediated expression of a short 20-mer peptide derived from the NS5A protein in human T cells was sufficient to inhibit TCA. Synthetic 20-mer NS5A peptide also inhibited TCA in primary human T cells. Mechanistically, the NS5A protein interacted with Lck and inhibited proximal TCR signaling. Importantly, NS5A peptide expression did not cause global T cell signaling dysfunction as distal T cell signaling was not inhibited. Finally, recombinant adeno-associated virus (AAV) vector expressing the 20-mer NS5A peptide reduced both the recall antigen and the TCR-mediated activation of human T cells and did not cause global T cell signaling dysfunction. Together, these data suggest that expression of a 20-mer NS5A peptide by an AAV vector may reduce unwanted TCA and may contribute to lower vector immunogenicity during gene therapy.

59 BASIC BIOLOGICAL SCIENCES↗

Rotating shift work, sleep, and accidents related to sleepiness in hospital nurses

A hospital-based survey on shift work, sleep, and accidents was carried out among 635 Massachusetts nurses. In comparison to nurses who worked only day/evening shifts, rotators had more sleep/wake cycle disruption and nodded off more at work. Rotators had twice the odds of nodding off while driving to or from work and twice the odds of a reported accident or error related to sleepiness. Application of circadian principles to the design of hospital work schedules may result in improved health and safety for nurses and patients.

Non-NASA Center↗

Human behavioral research in space: quandaries for research subjects and researchers

With the advent of long-duration spaceflight on board the International Space Station (ISS) and possible future missions beyond low Earth orbit (LEO) such as Mars, it is critical that those at NASA have a realistic assessment of the challenges that will face individuals on long-duration missions so that they can develop preventive and real-time countermeasures to behavioral health issues. While space travellers are very interested in having countermeasures to the deleterious effects of space missions, they have a powerful disincentive to participate in this research if they feel it could in any way negatively affect their flight status. The behavioral issues of isolation and confinement for extended-duration space missions are reviewed. Areas of basic and clinical behavioral research are listed. And the classical clinical model for research is not considered appropriate for the current configuration of the space program. The use of analogue environments and advanced statistical analysis are suggested as ways to address the limited spaceflight research opportunities. The challenge of research subject or patient confidentiality vs. mission safety and issues of personal flight status are addressed.

Review, Tutorial↗

NASA: Biomedical applications team

The status of projects involving the adaptation of NASA technologies for medical purposes is reviewed. Devices for the measurement of joint deformation of arthritic hands, the development of an artificial pancreas, provision of an auditory signal to avert epileptic seizures, are described along with the control of medication levels, a compressed air tank to supply power for field dentistry, and an electroencephalogram monitor. The use of the Lixiscope as a portable fluoroscope, thermal laminates for hand and foot warmers for patients with Raynaud's syndrome, and the use of absorptive coatings for instruments for controlling medication levels are described. The applicability of occupation health and safety practices to industry, computerized patient scheduling, impregnation of the common facial tissue with an agent for killing respiratory viruses, commercial applications of anthropometric data, and multispectral image analysis of the skin as a diagnostic tool are reviewed.

Source record↗