Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle plasma measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Particle charge distributions in the effluent of a flow-through atmospheric pressure low temperature plasma

Atmospheric pressure low-temperature plasmas are often utilized to perform particle synthesis, treatment, and removal. It is well-known that dust particles are highly negatively charged in these plasmas; however, little is known about dust particle charging behavior as particles leave the plasma volume and pass through the spatial afterglow region. In this work, monodisperse particles of various sizes and work functions were introduced into an atmospheric pressure radiofrequency capacitively coupled flow-through plasma. Dust particle electrical mobility distributions downstream of the flow-through plasma were measured utilizing a differential mobility analyzer in conjunction with a condensation particle counter at various gas flow velocities. Charge distributions were determined from the measured electrical mobility distributions. Experiments confirm that particles become less negatively charged, and even net-positively charged after leaving the plasma volume, with a distribution that follows a shifted Boltzmann charge distribution. Additionally, particle charge in the effluent of the flow-through plasma is negligibly dependent on work function but highly size and flow velocity dependent. Larger particles were shown to have a higher magnitude of charge under all studied conditions; however, particle polarity was switchable by varying gas flow velocity. The charging dynamics were simulated utilizing a constant number Monte Carlo model that accounts for electron temperature decay and the transition from ambipolar to free diffusion of electrons and ions in the spatial afterglow. Simulation results also suggest that, at the same flow velocity, larger particles obtain a greater magnitude of charge, negative or positive. Furthermore, the decrease in electron mobility and the difference between ion and electron convective loss rates create an ion-rich region in the plasma effluent that promotes ion–particle collisions and drives particle charge removal and even reversal of polarity. Larger particles more favorably collide with energetic species in these environments, which results in higher charge states.

atmospheric pressure low temperature plasma↗

Neutral Atomic Beam Techniques for Diagnosis of Edge and Scrape-Off Layer Plasmas (2017-2019) [and subsequently titled] Neutral Atomic Beam Techniques for Diagnosis of Interior and Scrape-Off Layer Plasmas (2019-2022) (Final Report)

This is the Final Technical Report for the DOE Measurement Innovation grant DE-SC0017998 titled Neutral Atomic Beam Techniques for Diagnosis of Edge and Scrape-Off Layer Plasmas (2017-2019) and subsequently titled Neutral Atomic Beam Techniques for Diagnosis of Interior and Scrape-Off Layer Plasmas (2019-2022). The grant was funded by the Office of Fusion Energy Sciences (FES) for the period 1 September 2017 – 31 May 2022. Work performed through the grant has resulted in diagnostic innovations and new measurement capabilities that could improve understanding of magnetic equilibrium, edge localized modes in tokamaks, and bootstrap and Pfirsch-Schlüter currents in stellarators. We have performed simulations of a novel non-hydrogen beam-based diagnostic that would determine a local value (in the plasma) of the poloidal flux function by measuring the toroidal angle of the beam particles' velocity at a detector external to the plasma. The approach is similar to that of a Heavy Ion Beam Probe (HIBP), but would be able to operate with a smaller, more economical detection systems and, in doing so, may enable substantial extension of scenarios in which beam-based diagnostics are deployed. Key results include: Identification of the neutral and singly charged atoms that are most appropriate for use in the beam based diagnostic and the ionization cross-sections that are important for studying the plasma edge of a large device; Development of a promising geometry for operation in which the beam is injected horizontally near the torus midplane; Implementation of simulations using banana orbit trajectories of secondary beam ions to access plasma regions that are commonly in-accessible to an HIBP diagnostic, including sample volumes near the X-point of a diverted tokamak; Assessment of the ability of the diagnostic concept (originally developed under the assumption of, and reliant on, symmetry) to work in stellarators by performing simulations with both quasi-symmetric fields and non-quasi-symmetric fields; Measurement of noise levels with a prototype detector on a stellarator and exploration of techniques to minimize effects of noise on a diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Λ polarization from vortex rings as the medium response for jet thermalization

We performed a systematic study on the formation of vorticity rings as the process for jet thermalization in the medium created in high-energy nuclear collisions. In this work, we expanded our previous analysis to a more realistic framework by considering noncentral events and fluctuations in the initial condition. We simulate the formation and evolution of the flow vortex structure in a relativistic viscous hydrodynamic model and study the sensitivity of the proposed “ring observable” (ℛ$^{𝑡}_{Λ}$) that can be measured experimentally through the polarization of Λ hyperons. We show that this observable is robust with respect to fluctuating initial conditions to capture the jet-induced vortex flow signal and further study its dependence on different model parameters, such as the jet's velocity, position, the fluid's shear viscosity, and the collision centrality. The proposed observable is associated with the formation of vorticity in a quark-gluon plasma, showing that the measurement of particle polarization can be a powerful tool to probe different properties of jet-medium interactions and to understand better the polarization induced by the transverse and longitudinal expansions of the medium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron emission from particles strongly affects the electron energy distribution in dusty plasmas

The electron energy distribution of a low-temperature dusty plasma has been measured via a Langmuir probe. An unexpected broad peak at energy in the 2–4 V range has been observed. This can be theoretically reproduced for a sufficiently large electron emission rate from the nanoparticles dispersed in the plasma. A careful analysis of the nanoparticle energy balance, using measured values of nanoparticle concentration and plasma density, confirms that particles are sufficiently hot under the conditions of this study to rapidly inject electrons into the plasma via field-assisted thermionic emission. This work suggests that the presence of dust affects the plasma ionization balance more deeply than previously thought.

36 MATERIALS SCIENCE↗

Spatiotemporal Plasma-Particle Characterization of Dry Aerosols Using Nanosecond, Femtosecond, and Filament Laser-Produced Plasmas

The ability to rapidly characterize dry aerosols in air using laser-induced breakdown spectroscopy (LIBS) with femtosecond laser pulses promises advancement towards real-time atmospheric sampling and standoff capabilities. Of particular interest is the ability to apply LIBS in the context of low-particle loaded environments where discrete particle interactions must be observed within the sampling volume of the laser-produced plasma (LPP). In this study, dry nanoparticles in suspension are generated from a standard solution and sampled in air using Q-switched nanosecond (ns-) pulses, short-focus (SF) femtosecond (fs-) pulses, and filaments. Short time-gated plasma images are captured to observe spatially and temporally varying discrete plasma-particle interactions, which is shown to influence early air breakdown behavior and subsequent plasma evolution. Along with images, photo-multiplier tube (PMT) measurements are conducted where strong spatiotemporal dependencies are exhibited by the collected emission signal on particle proximity and plasma expansion behavior. Finally, conditional analysis is performed on LIBS measurements to determine associated sampling probabilities and filter out spectra with poor or absent emission peaks with an adaptive threshold algorithm.

42 ENGINEERING↗

A flexible proton beam imaging energy spectrometer (PROBIES) for high repetition rate or single-shot high energy density (HED) experiments (invited)

The PROBIES diagnostic is a new, highly flexible, imaging and energy spectrometer designed for laser-accelerated protons. The diagnostic can detect low-mode spatial variations in the proton beam profile while resolving multiple energies on a single detector or more. When a radiochromic film stack is employed for “single-shot mode,” the energy resolution of the stack can be greatly increased while reducing the need for large numbers of films; for example, a recently deployed version allowed for 180 unique energy measurements spanning ~3 to 75 MeV with <0.4 MeV resolution using just 20 films vs 180 for a comparable traditional film and filter stack. When utilized with a scintillator, the diagnostic can be run in high-rep-rate (>Hz rate) mode to recover nine proton energy bins. Here, we also demonstrate a deep learning-based method to analyze data from synthetic PROBIES images with greater than 95% accuracy on sub-millisecond timescales and retrained with experimental data to analyze real-world images on sub-millisecond time-scales with comparable accuracy.

3D printing↗

Conceptual design of a heavy ion beam probe diagnostic for the Wendelstein 7-X Stellarator

This article describes the current state of the design of the heavy ion beam probe (HIBP) for Wendelstein 7-X (W7-X). It will be the first HIBP diagnostic on an optimized stellarator and is designed to study electric fields and ion scale turbulence in all W7-X reference magnetic configurations. The use of an existing 2 MV accelerator, located outside of the torus hall, results in the need for a circuitous primary beamline. This increases the complexity of the ion optics design to deliver a focused beam to the plasma. To access most of the magnetic configuration space of W7-X, the secondary beamline and an energy analyzer are designed to pivot, thereby redirecting a wider range of secondary beam trajectories. Signal level estimates indicate that the equilibrium potential can be measured at all radii and that the radial coverage for potential and density fluctuations measurements depends on the plasma density.

47 OTHER INSTRUMENTATION↗

Nanosecond Repetitively Pulsed (NRP) Plasmas: Relationship Between Induced Flow and Plasma Characteristics at Atmospheric Pressure (Final Technical Report)

The local flow fields induced by plasma discharges at atmospheric pressure can play a critical role in aerodynamic flow and combustion control and have significant implications for plasma-based technologies in medicine and environmental engineering. However, the coupling between the plasma characteristics, the geometry and the induced flow field is not well understood. The primary goal of this work is to determine the relationship between the plasma characteristics and the induced flow field for nanosecond pulsed discharges at atmospheric pressure. A comprehensive experimental investigation of plasmas produced by nanosecond high-voltage pulses in a pin-to-pin electrode configuration was conducted, employing several measurement techniques including microwave and laser Rayleigh scattering, optical emission spectroscopy, and high-speed imaging. The flow field induced by the nanosecond plasma was measured and characterized using measurements of the velocity (particle image velocimetry) and density (background oriented schlieren) with unprecedented spatiotemporal resolution. The experimental measurements were complemented by development of a one-dimensional model of the plasma discharge and a high-fidelity computational fluid dynamics (CFD) simulation of the subsequent plasma-induced flow field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding the depletion of electrons in dusty plasmas at atmospheric pressure

The nucleation and growth of NPs in the gas phase using atmospheric-pressure plasma systems is an important approach to synthesizing novel dimensionally-controlled materials. In this paper, we investigated the effect of the NPs on a typical type of continuous-flow, substrate-free plasma at atmospheric pressure to understand their potential contribution to electron density changes. A tandem plasma system was set up consisting of one plasma reactor that produced carbonaceous NPs from mixtures of argon and hexane, and another identical plasma reactor where the as-grown particles were injected and non-intrusive electrical and optical measurements were performed. The electron densities obtained from conductivity measurements and a plasma fluid model were found to decrease in the presence of NPs. However, control experiments revealed that the main source of the electron depletion was residual vapor or reaction byproducts in the form of molecular species or nanoclusters and not the particles themselves. These results were validated by constant number Monte Carlo simulations which showed that at the experimentally-measured conditions, the NPs were not of sufficiently high enough concentration to reduce the electron density; however, if molecules or clusters are ionizable, they remain in sufficient concentration to deplete electron densities. Our study shows that at atmospheric pressure, because of their typically larger electron density values, particle-producing plasmas are distinct from those at low pressure, and nanoparticle formation does not have the same impact while molecular-scale species may be a more important consideration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New insights on divertor parallel flows,E × B drifts, and fluctuations from in situ, two-dimensional probe measurement in the Tokamak à Configuration Variable

Abstract In situ , two-dimensional (2D) Langmuir probe measurements across a large part of the TCV outer divertor are reported in L-mode discharges with and without divertor baffles. This provides detailed insights into time averaged profiles, particle fluxes, and fluctuation behavior in different divertor regimes. The presence of the baffles is shown to substantially increase the divertor neutral pressure for a given upstream density and to facilitate the access to detachment, an effect that increases with plasma current. The detailed, 2D probe measurements allow for a divertor particle balance, including ion flux contributions from parallel flows and E × B drifts. The poloidal flux contribution from the latter is often comparable or even larger than the former, and the divertor parallel flow direction reverses in some conditions, pointing away from the target. In most conditions, the integrated particle flux at the outer target can be predominantly ascribed to ionization along the outer divertor leg, consistent with a closed-box approximation of the divertor. The exception is a strongly detached divertor, achieved here only with baffles, where the total poloidal ion flux even decreases towards the outer target, indicative of significant plasma recombination. The most striking observation from relative density fluctuation measurements along the outer divertor leg is the transition from poloidally uniform fluctuation levels in attached conditions to fluctuations strongly peaking near the X-point when approaching detachment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pore connectivity influences mass transport in natural rocks: Pore structure, gas diffusion and batch sorption studies

For this work, six rocks (one granodiorite, one limestone, two chalks, one mudstone, and one dolostone) with different extents of heterogeneity at six different particle sizes (from 75 to 8000 μm) were studied to describe the effects of pore connectivity on mass transport. The methods applied were (i) porosity measurement of granular rocks, (ii) analyses of gas-phase diffusive transport in a bed of packed particles, along with a solid quartz method at these six particle sizes being developed to identify the contribution of intraparticle diffusion, and (iii) batch sorption tests of multiple ions (anions and cations) with subsequent analyses of inductively coupled plasma-mass spectrometry. Granular porosity measurement results reveal that with decreasing particle sizes, the effective porosities for the “heterogenous” group of rocks (Grimsel granodiorite and Edwards limestone) increase, whereas the porosities of another “homogeneous” group (two Israel chalk samples, Japan mudstone, and Wyoming dolostone) remain constant. Gas diffusion results show that the intraparticle gas diffusion coefficient among these two sample groups, varying in the magnitude of 10 -8 to 10 -6 m 2 /s, are not directly correlated to the porosity differences. Moreover, the batch sorption work displays a different affinity of rocks for various tracers. For Grimsel granodiorite, Japan mudstone, and Wyoming dolostone, the adsorption capacity of Sm 3+ and Eu 3+ increases as the particle size decreases. In general, this integrated research of grain size distribution, granular rock porosity, intraparticle diffusivity, and ionic sorption capacity gives insights into the pore connectivity effect on both physical and chemical transport behaviors for different lithologies and/or different particle sizes.

58 GEOSCIENCES↗

The Orbitron: A crossed-field device for co-confinement of high energy ions and electrons

To explore the confinement of high-energy ions above the space charge limit, we have developed a hybrid magnetic and electrostatic confinement device called an Orbitron. The Orbitron is a crossed-field device combining aspects of magnetic mirrors, magnetrons, and orbital ion traps. Ions are confined in orbits around a high-voltage cathode with co-rotating electrons confined by a relatively weak magnetic field. Experimental and computational investigations focus on reaching ion densities above the space charge limit through the co-confinement of electrons. The experimental apparatus and suite of diagnostics are being developed to measure the critical parameters, such as plasma density, particle energy, and fusion rate for high-energy, non-thermal plasma conditions in the Orbitron. Initial results from experimental and computational efforts have revealed the need for cathode voltages on the order of 100–300 kV, leading to the development of a custom high voltage, ultra-high vacuum bushing rated for 300 kV.

Materials Science↗

Visualization of fast ion phase-space flow in plasmas well-below, near and well-above Alfvén eigenmode stability threshold in tokamak

Abstract Transport of fast ions along certain local phase space paths, referred to as fast ion phase-space flow, has been systematically measured by an imaging neutral particle analyzer (INPA) in three plasma regimes, which are well-below, near, and well-above the Alfvén eigenmode stability threshold (Du et al 2021 Phys. Rev. Lett. 127 235002). (1) In plasmas well-below the Alfvén eignenmodes (AE) stability threshold, fast ions are well-confined on passing particle orbits without noticeable transport over the phase space. The observed INPA images agree well with the synthetic INPA images, using the fast ion distribution predicted by neoclassical theory. (2) In plasmas near the AE stability threshold, INPA images in the presence of AE activity moderately deviate from those without AE activity. The image difference can be well interpreted by AE-driven, phase-space fast ion flow. Paths of this flow over the velocity space (or streamlines) are reconstructed by the intersection lines of curved E ʹ and µ surfaces, referred to as E ʹ and µ line (where E ′ ≡ E − ( ω / n ) P ζ ; E , P ζ and µ are the energy, canonical toroidal momentum and magnetic moment of ions; ω and n are the angular frequency and toroidal mode number of AEs, respectively). Resonant fast ions move radially inward by gaining energy and move radially outward by losing energy and the trajectory well aligns with the E ʹ and µ lines that pass through the mode resonances near the injection energy of neutral beams. (3) In plasmas well-above the AE stability threshold, fast ion phase-space dynamics shows additional features. Fast ions are transported out of the birth positions so promptly along the streamlines that the slowing-down process from the injection energy is not observable, exhibiting strong critical gradient behavior at local phase space. As a result, the increase of electron temperature is very small, in spite of an increase of beam power by ∼ 45 % . It should be emphasized that the directions of phase-space transport, induced by AEs with different frequencies, structures and mode numbers, do not largely differ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion concentration ratio measurements of ion beams generated by a commercial microwave electron cyclotron resonance plasma source

A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.

47 OTHER INSTRUMENTATION↗

Dissipation of electron-beam-driven plasma wakes

Metre-scale plasma wakefield accelerators have imparted energy gain approaching 10 gigaelectronvolts to single nano-Coulomb electron bunches. To reach useful average currents, however, the enormous energy density that the driver deposits into the wake must be removed efficiently between shots. Yet mechanisms by which wakes dissipate their energy into surrounding plasma remain poorly understood. Here, we report picosecond-time-resolved, grazing-angle optical shadowgraphic measurements and large-scale particle-in-cell simulations of ion channels emerging from broken wakes that electron bunches from the SLAC linac generate in tenuous lithium plasma. Measurements show the channel boundary expands radially at 1 million metres-per-second for over a nanosecond. Simulations show that ions and electrons that the original wake propels outward, carrying 90 percent of its energy, drive this expansion by impact-ionizing surrounding neutral lithium. The results provide a basis for understanding global thermodynamics of multi-GeV plasma accelerators, which underlie their viability for applications demanding high average beam current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cold Plasma Measurements

We have continued the simulation campaign in support of our ongoing magnetospheric cold plasma research project. This project aims to develop the next-generation particle instruments to measure the properties of the cold particle populations in the Earth’s magnetosphere. For this purpose, simulations have been performed with a Particle-In-Cell (PIC) code called the Curvilinear PIC (CPIC). The code is formulated in curvilinear geometry and couples the standard PIC algorithm with algorithms for the generation and adaptation of the underlaying computational mesh. It conforms to complex objects like spacecraft and it can place more grid points in regions where higher resolution is needed. The code also features a scalable solver based on the multigrid algorithm and it is fully parallelized via domain decomposition and MPI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical diagnostics of laser-produced plasmas

Laser-produced plasmas (LPPs) engulf exotic and complex conditions ranging in temperature, density, pressure, magnetic and electric fields, charge states, charged particle kinetics, and gas-phase reactions, based on the irradiation conditions, target geometries, and the background cover gas. The application potential of the LPP is so diverse that it generates considerable interest for both basic and applied research areas. The fundamental research on LPPs can be traced back to the early 1960s, immediately after the invention of the laser. In the 1970s, the laser was identified as a tool to pursue inertial confinement fusion, and since then, several other technologies emerged out of LPPs. These applications prompted the development and adaptation of innovative diagnostic tools for understanding the fundamental nature and spatiotemporal properties of these complex systems. Although most of the traditional characterization techniques developed for other plasma sources can be used to characterize the LPPs, care must be taken to interpret the results because of their small size, transient nature, and inhomogeneities. The existence of the large spatiotemporal density and temperature gradients often necessitates non-uniform weighted averaging over distance and time. Among the various plasma characterization tools, optical-based diagnostic tools play a key role in the accurate measurements of LPP parameters. The optical toolbox contains optical spectroscopy (emission, absorption, and fluorescence), passive and active imaging and optical probing methods (shadowgraphy, Schlieren, interferometry, Thomson scattering, deflectometry, and velocimetry). Each technique is useful for measuring a specific property, and its use is limited to a certain time span during the LPP evolution because of the sensitivity issues related to the selected measuring tool. Therefore, multiple diagnostic tools are essential for a comprehensive insight into the entire plasma behavior. In recent times, the improvements in performance in the lasers and detector systems expanded the capability of the aforementioned passive and active diagnostics tools. Furthermore, this review provides an overview of optical diagnostic tools frequently employed for the characterization of the LPPs and emphasizes techniques, associated assumptions, and challenges. Considering most of the industrial and other applications of the LPP belong to low to moderate laser intensities (10 8 – 10 15 Wcm –2 ), this review focuses on diagnostic tools pertaining to this regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗